Featured Highlights
- Outdoor Coil Fan
- High Capacity Liquid Line Drier
- High Pressure Switch
- Low Pressure Switch
- Scroll Compressor
- Heavy Gauge Steel Cabinet
- Refrigerant Line Connections and Access
SPLIT AIR CONDITIONER SYSTEM
Minimum Efficiency: 13.8 SEER2
Applications
- 1.5 through 5 tons
- Sound levels as low as 73 dBA
- Single-phase power supply
- Vertical air discharge
- Applicable to indoor air handlers or gas furnaces with indoor add-on coils
- Shipped completely factory assembled, piped and wired
Approvals
- AHRI Standard 210/240-2023 certified
- AHRI Certified system match-ups and expanded ratings, visit www.marsdeliversratings.com
- ENERGY STAR® Certified
- Sound rated to AHRI Standard 270-2008 test conditions
- Rated According to U.S. Department of Energy (DOE) test procedures
- Region specific models meet the minimum efficiency requirements for U.S. DOE Federal Regional Standards in that area
- Unit and components ETL, NEC and CEC bonded for grounding to meet safety standards for servicing
- ETL certified (U.S. and Canada)
- ISO 9001 Registered Manufacturing Quality System
For the latest AHRI system matches, please visit www.marsdeliversratings.com or AHRIdirectory.org.
For system matches, visit www.comfort-aire.com.
REFRIGERATION SYSTEM
R-454B Refrigerant
- Low GWP (Global Warming Potential)
- Zero ODP (Ozone Depletion Potential)
- Unit is factory pre-charged
Outdoor Coil Fan
- Direct drive fan
- Vertical air discharge
- Totally enclosed fan motor
- Sleeve bearings (018 through 048 and 060 models)
- Inherently protected
- Motor rain shield
- Louvered steel fan guard
Condenser Coil
- Proprietary coil design
- Enhanced aluminum alloy tube/enhanced fin coil
- Superior corrosion resistance
- Ripple-edged aluminum fins
- Aluminum tube construction
- Lanced fins for maximum fin surface exposure
- Fin collars grip tubing for maximum contact area
- Flared shoulder tubing connections
- Factory tested under high pressure
- Entire coil is accessible for cleaning
High Capacity Liquid Line Drier
- Furnished with unit for field installation
- Drier traps moisture or dirt that could contaminate the system
- 100% molecular-sieve, bead type, drier
High Pressure Switch
- Protects the system from high pressure conditions that can be a result of fan failure or a blocked/dirty coil
- Manual reset
Low Pressure Switch
- Shuts off unit if suction pressure falls below setting
- Provides loss of charge and freeze-up protection
- Automatic reset
Optional Accessories
Expansion Valve Kits
- Factory installed with R-454B on all indoor units
- Chatleff-style fitting
Freezestat
- Senses suction line temperature
- Cycles compressor off when suction line temperature falls below freezestat setpoint
- Opens at 29°F and closes at 58°F
- Installs on or near the discharge line of the evaporator or on the suction line
Loss of Charge Switch Kit
- Protects compressor from damage from low refrigerant charge conditions
- SPST, normally-closed
- Automatic reset
INDOOR REFRIGERANT DETECTION SYSTEM (RDS)
- Complies with UL 60335-2-40 approved standard
- Required for all systems using R-454B refrigerant
- Factory or field installed on all indoor units
- Consists of a RDS refrigerant detection sensor and an independent RDS control
- If refrigerant is detected the refrigerant detection system will prevent compressor and heating operation until refrigerant is no longer detected
- Refrigeration detection system also energizes the blower if refrigerant is detected to dissipate any concentrations of refrigerant from the space
COMPRESSOR
Single-Stage Scroll Compressor
- High volumetric efficiency
- Uniform suction flow
- Constant discharge flow
- High efficiency
- Quiet operation
- Low gas pulses during compression reduces operational sound levels.
- Compressor motor is internally protected from excessive current and temperature
- Muffler in discharge line reduces operating sound levels
- Compressor is installed in the unit on resilient rubber mounts for vibration free operation
Scroll Compressor Operation
- Two involute spiral scrolls matched together generate a series of crescent-shaped gas pockets between them
- During compression, one scroll remains stationary while the other scroll orbits around it
- Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates
- As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced
- When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls
- During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle
- Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency
- Compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged
Compressor Crankcase Heater
(048, 060 Models)
- Prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication
Optional Accessories
Compressor Crankcase Heater (018, 024, 030, 036, 042 Models)
- Prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication
Compressor Sound Cover
- Polymer outer shell
- 1/2 inch thick polyester fiber insulation
- All open edges are sealed with a one-inch wide hook and loop fastening tape
Compressor Hard Start Kit
- Single-phase units are equipped with a PSC compressor motor
- This type of motor normally does not need a potential relay and start capacitor
- For conditions such as low voltage, kit may be required to increase the compressor starting torque
Compressor Low Ambient Cut-Off Switch
- Non-adjustable switch (low ambient cut-out)
- Prevents compressor operation when outdoor temperature is below 35°F
Compressor Time-Off Control
- Kit prevents compressor short-cycling
- Allows time for suction and discharge pressure to equalize
- Permits compressor start-up in an unloaded condition.
- Automatic reset with 5 minute delay between compressor shut-off and start-up
Indoor Blower Off Delay Relay
- Delays the indoor blower-off time during the cooling cycle
Low Ambient Kit
- Air conditioners can operate down to 45°F outdoor air temperature without additional controls
- Allows unit to operate properly down to 30°F
- NOTE - Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit.
- NOTE - A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions.
CABINET
- Heavy gauge steel construction
- Louvered heavy gauge steel panels surround unit on all four sides
- Pre-painted cabinet finish
- Control box is conveniently located with all controls factory wired
- Corner patch plate allows access to compressor components
- Drainage holes are provided in base section for moisture removal
Refrigerant Line Connections, Electrical Inlets, Service Valves
- Sweat connection suction and liquid lines
- Located on corner of unit cabinet
- Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system
- Refrigerant line connections and field wiring inlets are located in one central area of the cabinet
- See dimension drawing
Braze-Free/Press Fitting Flexibility
- Units can accommodate braze-free or press fittings for installation versatility.
MODEL NUMBER GUIDE
Explains the structure of the model number, e.g., ASA14**S1:
- A: Air Conditioner
- S: Residential Split
- A: R-454B
- 14: Minimum SEER2
- 36: Capacity (BTUH x 1000)
- S: Single Stage
- 1: Power (1 = 208/230-1-60)
- A: Revision Level
Diagram Description: A diagram illustrates the top view of the outdoor unit, showing inlet air flow, suction line connection, and liquid line connection. It also indicates an optional unit stand-off kit and coil drain outlets. A second diagram shows the top view base section, highlighting the compressor and coil drain outlets.
UNIT DIMENSIONS
Model | A - Width (inch) | B - Depth (inch) | C - Height (inch) | Shipping Weight (Lbs.) |
---|---|---|---|---|
ASA1418S1 | 28-1/4 | 28-1/4 | 29-1/4 | 155 |
ASA1424S1 | 28-1/4 | 28-1/4 | 37-1/4 | 170 |
ASA1430S1 | 28-1/4 | 28-1/4 | 29-1/4 | 180 |
ASA1436S1 | 28-1/4 | 28-1/4 | 37-1/4 | 200 |
ASA1442S1 | 32-1/4 | 32-1/4 | 33-1/4 | 225 |
ASA1448S1 | 32-1/4 | 32-1/4 | 33-1/4 | 235 |
ASA1460S1 | 28-1/4 | 28-1/4 | 43-1/4 | 260 |
Note: Dimensions listed are unit sizes w/o packaging.
SOUND DATA
Size | Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ | Sound Rating Number (dBA) | 2 Estimated Sound Pressure Level at Distance From Unit (dBA at distance in ft.) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | 3 | 5 | 10 | 15 | 50 | ||
018 | 55.5 | 64.5 | 69 | 67.5 | 65 | 61 | 56 | 73 | 66 | 61 | 55 | 52 | 41 |
024 | 61.5 | 64 | 70 | 69.5 | 66 | 62.5 | 54.5 | 75 | 68 | 63 | 57 | 54 | 43 |
030 | 60 | 67 | 72 | 70.5 | 67.5 | 62.5 | 56 | 76 | 69 | 64 | 58 | 55 | 44 |
036 | 58 | 67.5 | 72.5 | 71.5 | 66.5 | 62 | 54.5 | 76 | 69 | 64 | 58 | 55 | 44 |
042 | 59.5 | 67.5 | 71.5 | 70 | 69 | 63.5 | 57.5 | 76 | 69 | 64 | 58 | 55 | 44 |
048 | 60 | 70.5 | 73.5 | 72.5 | 70.5 | 67 | 60.5 | 78 | 71 | 66 | 60 | 57 | 46 |
060 | 63.5 | 69.5 | 75 | 75 | 73 | 68 | 62.5 | 80 | 73 | 68 | 62 | 59 | 48 |
NOTE - The octave sound power data does not include tonal correction.
1 Tested according to AHRI Standard 270-2008 test conditions.
2 Estimated sound pressure level at distance based on AHRI Standard 275-2010 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275.
SPECIFICATIONS
Size | Nominal Tonnage | Sound Rating Number dBA | Connections (Sweat) | Liquid line (OD) - in. | Suction line (OD) - in. | Compressor Type | Refrigerant 1R-454B charge furnished | Indoor Unit Expansion Valve (TXV) | Outdoor Coil Net face area - ft.² Outer Coil | Inner Coil | Tube diameter - in. | Rows | Fins - in. | Outdoor Fan HP | Diameter - in. | Blades | Cfm | Rpm | Watts | Shipping Data - lbs. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ASA1418S1 | 1.5 | 76 | 3/8 | 3/4 | 1-Stage Scroll | 4 lbs. 14 oz. | 26Z70 | 16.33 | - | 5/16 | 1 | 26 | 1/8 | 22 | 2 | 2610 | 825 | 160 | 155 | |
ASA1424S1 | 2 | 75 | 3/8 | 3/4 | 1-Stage Scroll | 4 lbs. 14 oz. | 26Z70 | 21.00 | 15.75 | 5/16 | 1 | 26 | 1/8 | 22 | 3 | 2990 | 825 | 160 | 170 | |
ASA1430S1 | 2.5 | 72 | 3/8 | 3/4 | 1-Stage Scroll | 5 lbs. 10 oz. | 26Z70 | 16.33 | 15.75 | 5/16 | 2 | 22 | 1/8 | 22 | 3 | 2820 | 825 | 160 | 180 | |
ASA1436S1 | 3 | 73 | 3/8 | 7/8 | 1-Stage Scroll | 6 lbs. 13 oz. | 26Z70 | 21.00 | 20.25 | 5/16 | 2 | 22 | 1/6 | 22 | 3 | 3040 | 825 | 190 | 200 | |
ASA1442S1 | 3.5 | 76 | 3/8 | 7/8 | 1-Stage Scroll | 7 lbs. 2 oz. | 26Z71 | 22.17 | 21.33 | 5/16 | 2 | 22 | 1/4 | 26 | 3 | 4060 | 825 | 260 | 225 | |
ASA1448S1 | 4 | 75 | 3/8 | 7/8 | 1-Stage Scroll | 8 lbs. 14 oz. | 26Z71 | 24.93 | 24.13 | 5/16 | 2 | 22 | 1/4 | 22 | 4 | 3700 | 825 | 290 | 235 | |
ASA1460S1 | 5 | 75 | 3/8 | 1-1/8 | 1-Stage Scroll | 8 lbs. 14 oz. | 26Z72 | 29.09 | 28.16 | 5/16 | 2 | 22 | 1/4 | 26 | 4 | 4180 | 825 | 290 | 260 |
ELECTRICAL DATA
ASA1418S1 | ASA1424S1 | ASA1430S1 | ASA1436S1 | ASA1442S1 | ASA1448S1 | ASA1460S1 | |
---|---|---|---|---|---|---|---|
Line voltage data (Volts-Phase-Hz) | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 | 208/230-1-60 |
2Maximum overcurrent protection (MOCP) amps | 15 | 20 | 25 | 30 | 35 | 45 | 50 |
3Minimum circuit ampacity (MCA) | 11.2 | 13.6 | 16.6 | 21.8 | 23 | 29.7 | 31 |
Compressor Rated load amps | 8.3 | 10.3 | 12.7 | 16.7 | 17.3 | 22.4 | 23.7 |
Locked rotor amps | 45 | 60.2 | 75.6 | 93.5 | 123 | 126 | 157 |
Fan Motor full load amps | 0.74 | 0.74 | 0.74 | 1 | 1.4 | 1.7 | 1.4 |
Locked rotor amps | 1.65 | 1.65 | 1.65 | 1.9 | 3.2 | 3.2 | - |
OPTIONAL ACCESSORIES - ORDER SEPARATELY
Accessory | Model | ASA1418S1 | ASA1424S1 | ASA1430S1 | ASA1436S1 | ASA1442S1 | ASA1448S1 | ASA1460S1 |
---|---|---|---|---|---|---|---|---|
Compressor Hard Start Kit | Copeland 27V63 | • | • | • | • | • | • | • |
Crankcase Heater | LG 27U16 | • | • | • | • | • | • | • |
Compressor Hard Start Kit | Copeland 63W22 | |||||||
10J42 | • | • | • | • | • | • | • | |
LG 10J42 | • | • | • | • | • | • | • | |
LG 88M91 | • | • | • | • | • | • | • | |
Compressor Low Ambient Cut-Off Switch | 47J27 | • | • | • | • | • | • | • |
Compressor Timed-Off Control | 47J35 | • | • | • | • | • | • | • |
Freezestat | 93G35 | • | • | • | • | • | • | • |
Indoor Blower Off Delay Relay | 58M81 | • | • | • | • | • | • | • |
Loss of Charge Switch Kit | 84M23 | • | • | • | • | • | • | • |
4Low Ambient Kit (Fan Cycling) | 34M72 | • | • | • | • | • | • | • |
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1 Refrigerant charge is sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required.
2 HACR type breaker or fuse.
3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.
FIELD WIRING
Diagram Description: The field wiring diagram illustrates the connections between the Air Conditioner unit and the Heating Unit or Air Handler Unit. It shows two disconnect switches (by others), an optional thermostat, and power/low voltage wiring labeled A, B, C, and D. The descriptions for A, B, C, and D indicate the type of wiring (Two Wire Power, Four Wire Low Voltage, Five Wire Low Voltage) and gauge requirements. All wiring must conform to NEC or CEC and local electrical codes.
INSTALLATION CLEARANCES
Diagram Description: A diagram shows the top view of the outdoor unit with callouts for installation clearances. It specifies that service clearance of 30 inches (762 mm) must be maintained on one side adjacent to the control box. Clearances to other sides are specified as 36 inches (914 mm), 12 inches (305 mm), and 6 inches (152 mm). A clearance of 24 inches (610 mm) is required between two units.
TXV SUBSTITUTION - R-454B
A general guide for replacing the factory installed R-454B TXV if the indoor unit (coil/air handler) is larger or smaller than the outdoor unit.
Outdoor Unit Size | Tons | Indoor Unit | Indoor TXV Furnished | Indoor TXV Replacement | |
---|---|---|---|---|---|
Size | Tons | ||||
018 | 1.5 | 42 | 3.5 | 26Z71 | 26Z70 |
018 | 1.5 | 48 | 4 | 26Z71 | 26Z70 |
018 | 1.5 | 49 | 4 | 26Z71 | 26Z70 |
018 | 1.5 | 50/60 | 4/5 | 26Z71 | 26Z70 |
018 | 1.5 | 51/61 | 4/5 | 26Z71 | 26Z70 |
018 | 1.5 | 60 | 5 | 26Z72 | 26Z70 |
024 | 2 | 42 | 3.5 | 26Z71 | 26Z70 |
024 | 2 | 48 | 4 | 26Z71 | 26Z70 |
024 | 2 | 49 | 4 | 26Z71 | 26Z70 |
024 | 2 | 50/60 | 4/5 | 26Z71 | 26Z70 |
024 | 2 | 51/61 | 4/5 | 26Z71 | 26Z70 |
024 | 2 | 60 | 5 | 26Z72 | 26Z70 |
030 | 2.5 | 42 | 3.5 | 26Z71 | 26Z70 |
030 | 2.5 | 48 | 4 | 26Z71 | 26Z70 |
030 | 2.5 | 49 | 4 | 26Z71 | 26Z70 |
030 | 2.5 | 50/60 | 4/5 | 26Z71 | 26Z70 |
030 | 2.5 | 51/61 | 4/5 | 26Z71 | 26Z70 |
030 | 2.5 | 60 | 5 | 26Z71 | 26Z70 |
036 | 3 | 42 | 3.5 | 26Z71 | 26Z70 |
036 | 3 | 48 | 4 | 26Z71 | 26Z70 |
036 | 3 | 49 | 4 | 26Z71 | 26Z70 |
036 | 3 | 50/60 | 4/5 | 26Z71 | 26Z70 |
036 | 3 | 51/61 | 4/5 | 26Z71 | 26Z70 |
036 | 3 | 60 | 5 | 26Z72 | 26Z70 |
042 | 3.5 | 24 | 2 | 26Z70 | 26Z71 |
042 | 3.5 | 30 | 2.5 | 26Z70 | 26Z71 |
042 | 3.5 | 30/36 | 2.5/3 | 26Z70 | 26Z71 |
042 | 3.5 | 36 | 3 | 26Z70 | 26Z71 |
042 | 3.5 | 60 | 5 | 26Z72 | 26Z71 |
048 | 4 | 30/36 | 2.5/3 | 26Z70 | 26Z71 |
048 | 4 | 36 | 3 | 26Z70 | 26Z71 |
048 | 4 | 60 | 5 | 26Z72 | 26Z71 |
060 | 5 | 50/60 | 4/5 | 26Z71 | 26Z72 |
060 | 5 | 51/61 | 4/5 | 26Z71 | 26Z72 |
TXV Ranges:
- 26Z70 - 1.5 to 3 ton systems - Use on 3 ton (036) and lower systems.
- 26Z71 - 3.5-4 ton systems - Use down to 3.5 ton (042) systems.
- 26Z72 - 5 ton systems - Use on 5 ton (060) systems only.
Notes and Disclaimers
Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice or incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer. Additionally, the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations. Third party incentive and rebate programs have precise requirements as to product performance and certification. All products meet applicable regulations in effect on date of manufacture; however, certifications are not necessarily granted for the life of a product. Therefore, it is the responsibility of the applicant to determine whether a specific model qualifies for these incentive/rebate programs.
"This product complies with all California product labeling laws including, but not limited to, the Safe Drinking Water and Toxic Enforcement Act of 1986, more commonly known as Proposition 65.”
2025 MOTORS & ARMATURES, Inc. MARS is a registered trademark of Motors & Armatures, Inc. Comfort-Aire is a registered trademark of Motors & Armatures, Inc.
SP-1M 4/25 CA-ASA14S1_SPEC