GE Load Centers and Circuit Breakers
Section 1: PowerMark Gold and Plus Load Centers & Circuit Breakers
Table of Contents Overview
This document provides a detailed overview of GE's PowerMark Gold and Plus load centers and circuit breakers. It covers product features, benefits, and specifications for various single-phase and three-phase models, including main lug convertible to main breaker configurations. The catalog also details special purpose circuit breakers, HID lighting breakers, high magnetic breakers, and field-installed accessories such as equipment ground kits and isolated ground bar kits. Wiring diagrams are included for various load center models.
Q-Line Circuit Breakers
Product Features and Benefits:
- Q-Line circuit breakers offer reliable protection and performance.
PowerMark Gold Load Centers
Product Features and Benefits:
- PowerMark Gold load centers provide robust solutions for electrical distribution.
- Product Number Guides: Detailed guides for selecting the correct product numbers.
- Q-Line Plug-in Circuit Breakers: Easy-to-install breakers compatible with PowerMark Gold load centers.
- Special Purpose Circuit Breakers: Breakers designed for specific applications.
- Quick-Make, Quick-Break: Ensures rapid and safe switching operations.
- Multi-pole Breakers: Incorporate internal common trip for coordinated tripping of multiple poles.
PowerMark Gold and Plus Single-Phase Load Centers:
- Main Lug Convertible to Main Breaker: Flexibility in configuration.
- Main Breaker Factory Installed: Ready for immediate installation.
PowerMark Plus™ Three-Phase Load Centers:
- Main Circuit Breakers or Main Lugs Factory Installed: Options for main connection.
- PowerMark Gold Load Centers - Specialty Panels: Panels designed for specialized applications.
- PowerMark Gold Meter Socket Load Centers: Integrated meter socket solutions.
Field Installed Accessories:
- Various accessories available to enhance functionality.
Wiring Diagrams:
- Detailed diagrams illustrating wiring configurations for load centers and meter socket load centers.
- Knockouts: Information on knockout sizes and locations.
Special Purpose Circuit Breakers
60°C / 75°F Conductor Rating
Box Type Terminals
Quick-Make, Quick-Break
Multi-pole Breakers Incorporate Internal Common Trip
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description | Product Number |
Main Circuit Breaker Kit - Order appropriate THQL 10kAIC or THHQL 22kAIC breakers separately | TQMH0001 |
Note: Review footnotes for proper parts needed to convert to a main circuit breaker. This main breaker base is applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
Equipment Ground Fault
UL Listed Ground Fault Circuit Interrupters No. 943 30 milliampere ground fault trip level.
Ampere Rating | 10,000 AIC | Std. Pkg. | Product Number |
15 | 10,000 AIC | 10 Cartons of 1 | THQL1115GFEP |
20 | 10,000 AIC | 10 Cartons of 1 | THQL1120GFEP |
30 | 10,000 AIC | 10 Cartons of 1 | THQL1130GFEP |
Switching Neutral
UL Listed. 10kAIC RMS symmetrical. Standard 1- or 2-pole automatic breaker plus one fully-rated, non-automatic pole.
1-Pole Plus Switching Neutral 120/240 Volts ac | 2-Pole Plus Switching Neutral 120/240 Volts ac | |
Ampere Rating | Product Number | Product Number |
15 | THQL21WY15 | THQL31WY15 |
20 | THQL21WY20 | THQL31WY20 |
25 | THQL21WY25 | THQL31WY25 |
30 | THQL21WY30 | THQL31WY30 |
Std. Pkg. | 5 cartons of 5 | 5 cartons of 3 |
"HID" Lighting
UL Listed as HID. HID breakers are designed to handle current and voltage spikes from gaseous discharge lamps.
Ampere Rating | 1-Pole, 120/240 Volts ac | 2-Pole, 120/240 Volts ac | |
Product Number | Product Number | ||
10,000 AIC | 15 | THQL1115HID2 | THQL2115HID |
20 | THQL1120HID2 | THQL2120HID | |
30 | THQL1130HID | THQL2130HID | |
22,000 AIC | 15 | THHQL1115HID2 | THHQL2115HID |
20 | THHQL1120HID2 | THHQL2120HID | |
30 | THHQL1130HID | THHQL2130HID | |
Std. Pkg. | 5 cartons of 10 | 5 cartons of 5 |
UL Listed as SWD (switching duty). Suitable for 120 volts ac fluorescent lighting loads.
High Magnetic
UL Listed. 10kAIC RMS symmetrical. High short circuit setting suitable for circuits with inherent high-inrush load currents.
Ampere Rating | 1-Pole, 120/240 Volts ac Product Number |
15 | THQL1115HM |
20 | THQL1120HM |
25 | THQL1125HM |
30 | THQL1130HM |
40 | THQL1140HM |
50 | THQL1150HM |
Std. Pkg. | 5 cartons of 10 |
PowerMark Gold and Plus Load Centers - Single-Phase, Three-Wire, 120/240 Vac
Main Lugs Convertible to Main Breaker
Main Lugs Factory Installed (TLM units convertible to main breaker)
Ampere Rating | Main Lug | 1" Spaces | 1" Spaces | 1/2" Spaces | 1/2" Spaces | Total Spaces | Main Wire Size (AWG/kcmil) Cu | Main Wire Size (AWG/kcmil) Al | Feed Type | Box Type | Equipment Ground Kit | Product Number |
1 Pole | 2 Pole | 1 Pole | 2 Pole | 1-pole Front | ||||||||
40 | 2 | 1 | 4 | 1 | 4 | 14-4 | 6-3 | Top | R1A | TGK4 (order separately) | TL240RCU | |
70 | 2 | 1 | 4 | 1 | 4 | 14-4 | 6-3 | Top | R1A | TGK4 (order separately) | TL270RCU | |
100 | 5 | 0 | 0 | 0 | 5 | 14-4 | 6-3 | Flush Top | R41 | TGL1 installed | TL510RT2,8 | |
125 | 4 | 2 | 8 | 3 | 8 | 1-2/0 | 1-2/0 | Top | R1A | TGL1 (order separately) | TL412R12 | |
125 | 4 | 2 | 8 | 3 | 8 | 1-2/0 | 1-2/0 | Top | R1A | TGL1 installed | TL412RT12 | |
125 | 4 | 2 | 8 | 3 | 8 | 1-2/0 | 1-2/0 | Top | R41 | TGL1 (order separately) | TL412R22 | |
125 | 4 | 2 | 8 | 3 | 8 | 1-2/0 | 1-2/0 | Thermoplastic Top Front | R1 | TGL1 (order separately) | TPL412R2,3 | |
125 | 4 | 2 | 8 | 3 | 8 | 1-2/0 | 1-2/0 | Thermoplastic Top Front | R1 | TGL1 installed | TPL412RT2,3 | |
125 | 4 | 3 | 12 | 4 | 12 | 6-1 | 6-1 | Top | R2A | TGK12 (order separately) | TLM612RCU4 | |
125 | 8 | 4 | 16 | 8 | 16 | 6-1 | 6-1 | Top | R2A | TGK12 (order separately) | TLM812RCU4 | |
125 | 8 | 4 | 16 | 8 | 16 | 6-1 | 6-1 | Top | R3A | TGK12 (order separately) | TLM812RCU25 | |
125 | 14 | 6 | 20 | 8 | 24 | 6-2/0 | 6-2/0 | Top | R3A | TGK12 (order separately) | TLM1212RCU7,9 | |
125 | 24 | 12 | 0 | 0 | 24 | 6-2/0 | 6-2/0 | Top | R4A | TGK24 (order separately) | TLM2412RCU5 | |
150 | 24 | 12 | 12 | 4 | 30 | 1-3/0 (Cu), 2/0-3/0 (Al) | 2/0-3/0 (Al) | Top Bottom | R6A | TGK24 (order separately), TGK32 (order separately) | TLM2415RCU6 | |
200 | 12 | 6 | 24 | 10 | 24 | 6-250 | 6-250 | Top | R5A | TGK24 (order separately) | TLM1220RCU6 | |
200 | 16 | 8 | 32 | 14 | 32 | 6-250 | 6-250 | Top | R5A | TGK32 (order separately) | TLM1620RCU6 | |
200 | 20 | 10 | 40 | 18 | 40 | 6-250 | 6-250 | Top | R6A | TGK24 (order separately), TGK42 (order separately) | TLM2020RCU6 | |
200 | 24 | 12 | 36 | 18 | 42 | 1-250 (Cu), 2/0-250 (Al) | 2/0-250 (Al) | Top Bottom | R39 | TGK24 (order separately) | TLM2420R42 | |
200 | 32 | 16 | 16 | 6 | 40 | 1-250 (Cu), 2/0-250 (Al) | 1-250 (Cu), 2/0-250 (Al) | Top Bottom | R7A | TGK32 (order separately) | TLM3220RCU6 | |
200 | 40 | 20 | 0 | 0 | 40 | 6-250 | 6-250 | Top Bottom | R8A | TGK42 (order separately) | TLM4020RCU6 | |
225 | 42 | 20 | 0 | 0 | 42 | 1-300 (Cu), 2/0-300 (Al) | 2/0-300 (Al) | Top Bottom | R8A | TGK42 (order separately) | TLM4222RCU6 |
1: 140-225 amp single-phase devices have removable closing caps. Larger ampere devices require field-cut openings. Order hubs separately. See page 1-27.
2: 10 KAIC.
3: 125 amp maximum branch capacity.
4: For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-28, 100 amp maximum due to wire bending requirements.
5: For main breaker, order TQMH000. See page 1-24. Also order 2-pole THQL or THHQL circuit breaker. See page 1-5.
6: For main breaker, order THQMVXXXD circuit breaker from page 1-6.
7: For main breaker applications, use reverse feed THQL or THHQL circuit breaker (see page 1-5) and THQLRK3 breaker retainer (see page 1-28).
8: Main and branch breakers are limited to 70 amps.
9: Load center includes a factory installed ground bar and add-a-lug. See wiring diagram on page 1-30. A separate TGL2 can be added in the unlikely event that another ground bar is required.
Note: See page 11-4, AL Series Lighting Panelboards as replacements for 300-600A load centers.
Field Installed Accessories
PowerMark Gold Main Circuit Breaker Kit
For use with 125A PowerMark Gold load Centers; 22kAIC RMS symmetrical.
Description | Product Number |
Main Circuit Breaker Kit - Order appropriate THQL 10kAIC or THHQL 22kAIC breakers separately | TQMH0001 |
Note: Review footnotes for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, 12 circuit load centers with A C24 suffix, and the TLM812RCU2.
PowerMark Plus™ Equipment Ground Kits
Description | Standard Package Quantity | Product Number |
(4) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL | 20 | TGL1 |
(8) 14-8Cu/12-8AL, (6) 14-4Cu/6-4AL | 20 | TGL2 |
(7) 14-8Cu/12-8AL, (3) 14-4Cu/6-4AL, (2) 14-4Cu/12-4AL, (1) 14-2Cu/AL | 20 | TGL21 |
(1) 6-2/0Cu/Al Number of Terminals, (3) 10-1/0 Cu/Al Number of Terminals for 400 and 600 Amp | 20 | TGL81 |
(6) 10-1/0 Cu/Al Number of Terminals for 400 and 600 Amp | 20 | TGL202 |
Equipment Ground Kits | 1 | TNG33 |
Add-on Equipment Ground Lug (for use on any TGL Kit) | 1 | TNG64 |
Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole |
1TGL2, TGL4 and TGL8 mount interchangeably
2Add-on Equipment Ground Lug (for use on any TGL Kit)
3Suitable for use with up to six TPLUG108 lugs or six crimp lugs per pole
PowerMark Gold Equipment Ground and Isolated Ground Bar Kits4,5
Description | Standard Package Quantity | Product Number |
4-hole Ground | 1 | TGK4 |
12-hole Ground | 1 | TGK12 |
24-hole Ground | 1 | TGK24 |
32-hole Ground | 1 | TGK32 |
42-hole Ground | 1 | TGK42 |
4 46-12 circuit indoor load centers use PowerMark Plus style neutrals and grounds
5 Add TGKIS for isolated ground and mount to ground kit.
Wiring Diagrams
This section provides wiring diagrams for various GE load centers and circuit breakers, including:
- Breaker Symbol Key: Illustrates symbols for 1" THQL and 1/2" THQP breakers.
- Terminal Symbol Key: Shows terminal configurations and corresponding wire ranges (Cu/Al).
- Diagrams for specific models such as TL240SCU, RCU; TL270SCU, RCU; TL510RT; TPL412C, TL412C, TPL412R, TL412R1, TPL412CT, TL412CT; TL412R2, TL412R250GF, TL412R260GF; TPL412RT, TL412RT1; TLM612FCU, SCU, FCUD, SCUD, RCU; TLM812FCU, SCU, FCUD, SCUD, RCU; TM815RCUFL, TM820RCUFL; TM860FCUGEN, TLM830FCUGEN, TM860SCUGEN, TLM830SCUGEN, TM860RCUGEN, TLM830RCUGEN; TM1210CCU, TM1212CCU, TLM1212CCU; TM1210RCU, TM1212RCU, TLM1212RCU; TM1615CCU, TM1615RCU, TM1620CCU, TLM1612CCU, TM1612CCU, TM1612RCU; TLM1620CCU, TLM1620RCU; TLM812RCU2; TLM2012CCURP; TM2420R42B.
- Diagrams illustrating Main Lugs and Main Breaker configurations.
- Dimensional information for various components.
Related Documents
![]() |
Load Centers and Circuit Breakers: PowerMark Gold and Plus Load Centers Product Number Guides This document provides comprehensive product number guides for GE's PowerMark Gold and Plus Load Centers and Circuit Breakers. It details identification codes, types, enclosure options, bus ampere ratings, and wiring diagrams for various models, aiding in product selection and specification. |
![]() |
GE PowerMark Gold and Plus Load Center Accessories Catalog This catalog details GE PowerMark Gold and Plus load center accessories, including neutral kits, ground lug kits, subfeed lug kits, and feed-thru lugs. It provides descriptions, wire ranges, package quantities, and product numbers for each item. |
![]() |
PowerMark Gold Load Centers Installation Instructions Comprehensive installation guide for GE PowerMark Gold™ Load Centers (100-225 Ampere, Single-Phase, 12-42 Circuit, Indoor Type), covering general information, safety warnings, and step-by-step installation procedures. |
![]() |
General Electric AKR-75/100 and AKS-50 Low Voltage Power Circuit Breakers Maintenance Manual This maintenance manual provides detailed procedures and operational information for General Electric's AKR-75/100 and AKS-50 series low voltage power circuit breakers, covering inspection, maintenance, troubleshooting, and accessory installation. |
![]() |
GE GFC1001F-01 Food Waste Disposer Owner's Manual and Installation Guide Comprehensive owner's manual and installation guide for the GE GFC1001F-01 food waste disposer, covering safety, installation, operation, troubleshooting, and warranty information. Includes model series and dimensions. |
![]() |
GE 2015 27-Inch Top Load Washer Service Manual Comprehensive service manual for GE's 2015 27-inch top load washers, detailing model nomenclature, features, safety, disassembly, component replacement, and troubleshooting. |
![]() |
GE GTW485BMM*** ENERGY STAR Certified Residential Clothes Washer Specifications ENERGY STAR certification details (v8.0) for the GE GTW485BMM*** residential clothes washer. Provides key specifications including energy efficiency, water usage, dimensions, load configuration, and ENERGY STAR Product ID: 2306361. |
![]() |
GE 7.8 cu. ft. Front Load Electric Dryer with Steam (GFD65ESSVWW/GFD65ESPVDS) - Dimensions, Specs, and Features Detailed specifications, dimensions, installation requirements, and features for the GE 7.8 cu. ft. front load electric dryer with steam, models GFD65ESSVWW and GFD65ESPVDS. Includes electrical ratings, venting guidelines, and warranty information. |