TEST REPORT

Shenzhen Huatongwei International Inspection Co., Ltd.

Report No.CHTEW20120158
Project No.SHT2012028501EW
FCC ID2AQV7E360
ApplicantCALTTA TECHNOLOGIES CO., LTD.
AddressFloor 12, Building G2, international E-City, Nanshan District, Shenzhen, China, 518055
ManufacturerCALTTA TECHNOLOGIES CO., LTD.
AddressFloor 12, Building G2, international E-City, Nanshan District, Shenzhen, China, 518055
Test item descriptionBroadband Portable Radio
Trade MarkeChat
Model/Type referencee360
StandardFCC CFR Title 47 Part 15 Subpart C Section 15.247
Date of receipt of test sampleDec. 10, 2020
Date of testingDec. 11, 2020- Dec. 28, 2020
Date of issueDec. 29, 2020
ResultPASS

Compiled by

Silvia Li (File administrator)

Supervised by

Xiao Cheng (Project Engineer)

Approved by

Hans Hu (RF Manager)

Testing Laboratory

Shenzhen Huatongwei International Inspection Co., Ltd.

1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China

1. TEST STANDARDS AND REPORT VERSION

1.1. Test Standards

Tests were performed according to: FCC Rules Part 15.247 (Frequency Hopping, Direct Spread Spectrum and Hybrid Systems), ANSI C63.10:2013 (American National Standard for Testing Unlicensed Wireless Devices), and KDB 558074 D01 15.247 Meas Guidance v05r02.

1.2. Report version

Revision No.Date of issueDescription
N/A2020-12-29Original

2. TEST DESCRIPTION

Report ClauseTest ItemsStandard RequirementResult
5.1Antenna Requirement15.203/15.247(c)PASS
5.2AC Conducted Emission15.207PASS
5.3Peak Output Power15.247(b)(3)PASS
5.4Power Spectral Density15.247(e)PASS
5.56dB Bandwidth15.247(a)(2)PASS
5.699% Occupied Bandwidth-PASS*1
5.7Duty cycle-PASS*1
5.8Conducted Band Edge and Spurious Emission15.247(d)/15.205PASS
5.9Radiated Band Edge Emission15.205/15.209PASS
5.10Radiated Spurious Emission15.247(d)/15.205/15.209PASS

Note: Measurement uncertainty is not included. *1: No requirement on standard, only test data reported.

3. SUMMARY

3.1. Client Information

Applicant: CALTTA TECHNOLOGIES CO., LTD.

Address: Floor 12, Building G2, international E-City, Nanshan District, Shenzhen, China, 518055

Manufacturer: CALTTA TECHNOLOGIES CO., LTD.

Address: Floor 12, Building G2, international E-City, Nanshan District, Shenzhen, China, 518055

3.2. Product Description

Name of EUT: Broadband Portable Radio

Trade Mark: eChat

Model No.: e360

Power supply: DC 3.7V

Battery Information: DC 3.7V; 5100mAh

Adapter Information: Model: ES085H-X120100XYF, Input: 100-240Va.c. 50/60Hz 0.5A, Output: 12.0Vd.c. 1.0A

Hardware version: e320MB_B

Software version: e360V1.0

3.3. Radio Specification Description

Support type: 802.11b, 802.11g, 802.11n(HT20), 802.11n(HT40)

Modulation: DSSS for 802.11b; OFDM for 802.11g/802.11n(HT20)/802.11n(HT40)

Operation frequency: 2412MHz~2462MHz (802.11b/g/n HT20), 2422MHz~2452MHz (802.11n HT40)

Channel number: 11 (802.11b/g/n HT20), 7 (802.11n HT40)

Channel separation: 5MHz

Antenna type: PIFA antenna

Antenna gain: 1.9dBi

3.4. Testing Laboratory Information

Laboratory Name: Shenzhen Huatongwei International Inspection Co., Ltd.

Laboratory Location: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China

Qualifications: CNAS (L1225), A2LA (3902.01), FCC (762235), Canada (5377A)

4. TEST CONFIGURATION

4.1. Test frequency list

Selected channels for testing: Lowest, middle, and highest frequencies within the operating range.

4.2. Descriptions of Test mode

Tests were performed using different data rates, with final modes based on modulation and worst-case data rates: 802.11b (1Mbps), 802.11g (6Mbps), 802.11n(HT20) (MCS0), 802.11n(HT40) (MCS0).

4.3. Test mode

For RF test items: EUT was set to continuous transmit.

For AC power line conducted emissions: EUT connected to WLAN AP under large package transmission.

For Radiated spurious emissions: EUT was set to continuous transmit; tested in three orthogonal axes, worst case (X axis) reported.

4.4. Support unit used in test configuration and system

No support units were used.

4.5. Testing environmental condition

TypeRequirementActual
Temperature15~35°C25°C
Relative Humidity25~75%50%
Air Pressure860~1060mbar1000mbar

4.6. Measurement uncertainty

Test ItemMeasurement Uncertainty
AC Conducted Emission (150kHz~30MHz)3.02 dB
Radiated Emission (30MHz~1000MHz)4.90 dB
Radiated Emissions (1GHz~25GHz)4.96 dB
Peak Output Power0.51 dB
Power Spectral Density0.51 dB
Conducted Spurious Emission0.51 dB
6dB Bandwidth70 Hz

Uncertainty is expanded at 95% confidence level with k=1.96.

4.7. Equipment Used during the Test

Various test equipment was used for conducted and radiated emissions testing, including shielded rooms, EMI test receivers, spectrum analyzers, antennas, and power meters. Specific calibration dates and serial numbers are detailed in the original report.

5. TEST CONDITIONS AND RESULTS

5.1. Antenna Requirement

The EUT uses a PIFA antenna with a gain less than 6 dBi, complying with FCC CFR Title 47 Part 15 Subpart C Section 15.203 and 15.247(c)(1)(i). Result: Passed

5.2. AC Conducted Emission

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.207. Emissions were investigated from 0.15MHz to 30MHz. Result: Passed

5.3. Peak Output Power

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.247(b)(3). Limit is 30dBm. Detailed data in Appendix A. Result: Passed

5.4. Power Spectral Density

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.247(e). Limit is 8dBm in any 3 kHz band. Detailed data in Appendix B. Result: Passed

5.5. 6dB bandwidth

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.247(a)(2). Minimum bandwidth is 500 kHz. Detailed data in Appendix C. Result: Passed

5.6. 99% Occupied Bandwidth

Tested according to relevant standards. Detailed data in Appendix D. Result: Passed

5.7. Duty Cycle

Tested according to relevant standards. Detailed data in Appendix E. Result: Passed

5.8. Conducted Band edge and Spurious Emission

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.247(d). Emissions outside the band must be at least 20 dB below the in-band power. Detailed data in Appendix F. Result: Passed

5.9. Radiated Band edge Emission

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.247(d) and 15.209. Emissions falling in restricted bands were measured. Result: Passed

5.10. Radiated Spurious Emission

Tested according to FCC CFR Title 47 Part 15 Subpart C Section 15.209. Limits were applied for frequencies from 9 kHz up to 25 GHz. Detailed data tables are extensive; overall Result: Passed.

6. TEST SETUP PHOTOS

Photographs of the test setup for radiated emissions are available in the original document.

7. EXTERANAL AND INTERNAL PHOTOS

External and internal photos are referenced in test report No. CHTEW20120155.

8. APPENDIX REPORT

Additional detailed data is available in the Appendix Report.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5068704 Microsoft Word 2010 Microsoft Word 2010

Related Documents

Preview External Photos and Specifications of CALTTA E360 Broadband Portable Radio
Detailed external photographs and technical specifications for the CALTTA E360 Broadband Portable Radio, including its associated AC320 battery charger and ES085H-X120100XYF power adapter. This document provides visual evidence and key details of the equipment under test.
Preview Caltta PH660 Radio Maintenance Manual - Level 1 Guide
Detailed maintenance manual for the Caltta PH660 Radio (Level 1, V1.0). Includes specifications, function tests, software upgrades, disassembly, troubleshooting, and component information for service professionals.
Preview Caltta DH590 Digital Portable Radio Quick Start Guide
Get started with the Caltta DH590 Digital Portable Radio. This guide covers basic operations, key features, calling functions, technical specifications, and safety information for efficient use.
Preview Caltta PH600 Digital Portable Radio Quick Start Guide
A quick start guide for the Caltta PH600 Digital Portable Radio, covering basic operations, component descriptions, safety information, and compliance standards.
Preview Caltta PH690Ex: Explosion-Proof Digital Two-Way Radio | Features & Specifications
Explore the Caltta PH690Ex, a robust explosion-proof digital two-way radio designed for safety and performance in hazardous environments. Details on features, specifications, applications, and accessories.
Preview Caltta PD200 Dispatch System: Comprehensive Communication Solution
Explore the features and capabilities of the Caltta PD200 Dispatch System, a robust solution for voice, message, location, and patrol management. Designed for stability, reliability, and multi-service integration, it enhances communication efficiency in various sectors.
Preview Caltta PR900 Digital Repeater Quick Reference Guide
This guide provides essential information for the Caltta PR900 Digital Repeater, covering its overview, operations, settings, and technical specifications. Learn about unpacking, radio components, power management, voice and data transfer, IP connectivity, and detailed configuration options for digital and analog modes.
Preview Caltta PR900 Digital Repeater: Super Coverage, Flexible Networking
Explore the Caltta PR900 Digital Repeater, a robust communication solution offering super coverage and flexible networking. Key features include DMR compliance, enhanced security, superior audio quality, and compatibility with both digital and analog systems for diverse applications like public safety and forestry.