dormakaba RCI 909 Rocker Switches
Installation Guide
909 Surface Mount Instructions
- Remove decorative bezel around switch.
- Optional: To convert the momentary switch provided to maintained switch mode, carefully remove the spring located under the rocker switch with a small screwdriver or pliers.
- Mount switch base in desired location.
- Connect wires under appropriate terminals (See Figure 1).
- Replace decorative bezel.
909 Flush Mount Instructions
- Pry off decorative bezel around switch and remove toggle.
- Cut a 2-1/4” x 1-1/4” hole in the drywall.
- Connect wires under appropriate terminals (See Figure 2).
- Insert switch into hole. Tighten the two metal slot screws, until switch is secure.
- Replace toggle and decorative bezel.
Diagrams
Figure 1: Surface Mount Switch Wiring
The surface mount switch features a central rocker with an indicator resembling a key [key-symbol].
Terminals are labeled:
- "C - Power In" for the incoming power connection.
- "N/C Contact Power Out" for Normally Closed contact output.
- "N/O Contact Power Out" for Normally Open contact output.
The switch is rated 10A @ 250V.
Figure 2: Flush Mount Switch Wiring
The flush mount switch also features a central rocker with an indicator resembling a key [key-symbol].
Terminals are labeled:
- "C - Power In" for the incoming power connection.
- "L2" and "L3" for output connections.
- "N/C Contact - Power Out" for Normally Closed contact output.
- "N/O Contact - Power Out" for Normally Open contact output.
The switch is rated 10A @ 250V.
Specifications
Switch Mode | Switch Configuration | Switch Rating | Standard Finish |
---|---|---|---|
Momentary Action * | SPDT N/O or N/C | 10A @250V | Beige (plastic) |
NOTE: Specifications are subject to change without notice.
N/C - Normally Closed, N/O - Normally Open, C - Common
* Surface mounted switches only may be converted to Maintained Switch Mode.