Abestorm Hurricane 160P User's Manual
Brand: Abestorm Solutions INC.
Model: Hurricane 160P
Safety Instructions
- Do not adjust or alter the unit in any way.
- Use of unauthorized parts voids warranty. Contact approved distributor.
- Always unplug the unit before removing the cover.
- Inspect power cord before use; do not use if damaged.
- Use only with a 115V/60Hz circuit protected by a GFCI outlet.
Identification
Record serial number and date of purchase for future assistance. Data label on unit side has necessary information.
Model Number: Hurricane 160P
Serial Number: [Space for input]
Date of Purchase: [Space for input]
For questions: Contact installing contractor or Abestorm Solutions at sales@abestorm.com.
Electrical Supply
Power Supply: 110-120V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong
Circuit Protector: 15 Amp
WARNING: Using a 240V outlet may cause serious injury from electric shock.
To reduce risk of injury:
- Always disconnect machine from electrical power before servicing.
- Only plug unit into a grounded electrical circuit.
- Do not use an extension cord.
- Do not use a plug adapter.
How the Hurricane 160P Works
The dehumidifier uses its integral humidistat to monitor conditioned space. When conditions exceed the setpoint, the compressor activates. Air is drawn across an evaporator coil, where moisture condenses. The air is then reheated by the condenser coil and returned to the room.
Guidelines
Operation Notes
- Operate, transport, and store the unit on a stable surface.
- For maximum efficiency, keep windows and doors closed.
- Do not block the unit's inlet or outlet airflow.
Drain Hose Notes
- The unit has an external drain line connection.
- The drain line can be directed outside or into a sink/drain.
- Uncoil the entire hose for effective draining.
- Ensure the drain hose end is not higher than 15 feet.
- Always ensure the drain hose is not blocked.
Transportation Notes
- Secure the dehumidifier during transportation.
- If transported vertically, return to horizontal position and let it sit for 30 minutes before use.
Parts Diagram
The diagram shows two views of the Abestorm Hurricane 160P dehumidifier.
The top view highlights the 'Power Line', 'Control Panel', and 'Condensate Drain Line Quick Connect'.
The bottom view points out the 'Air Filter', 'Temp/RH Sensor', 'Air Inlet', 'Handle', and 'Air Outlet'.
Control Panel Guide
The control panel features several buttons and a display.
- Power Button: [Power Button] (Turns the unit on/off; returns to main screen from sub-menu).
- Confirm Button: [Confirm Button] (Confirms settings; increases humidity level by 5% per press, between 35% and 90%). Default humidity is 50%.
- Manual Drain Button: [Manual Drain Button] (Drains water from the integral pump reservoir before moving or storing).
- Mode Button: [Mode Button] (Switches between standard dehumidifier mode and duct mode).
Using the Display-Main Screen
1. Power On and Off
To power on: Press the power button. Display shows "POWER ON".
To power off: Press the power button on the main display screen. Display shows "UNIT OFF".
2. Setting Up the Unit
Upon powering on, the display shows:
UNIT ON 00.0 HRS
INLET 00°C 00%
- UNIT ON: Indicates the unit is powered on.
- 00.0 HRS: Displays running time from power on to power off, including defrosting time. Resettable via sub-menu. Max accumulation is 99.9 hours, then resets to zero.
- INLET 00°C 00%: Shows inlet air temperature and humidity. Temperature can be switched between °F/°C in sub-menu.
- To return to main menu from sub-menu: Press the power key.
3. Defrosting Screen
When defrosting, display shows "Defrost 000" (countdown). After completion, it returns to the main interface. Note: Sub-menu use may require returning to main interface to see countdown.
If powering off during defrosting, display shows "Wait for Defrost", indicating power off after defrost completes.
4. Compressor
Screen indicates time until the compressor starts running.
PLEASE WAIT COMP DELAY 000
5. Pump
Screen indicates remaining pump working time. Countdown starts at 14 seconds.
PUMP PURGING 00
Using the Display- Sub-Menus
1. Job hours
Allows clearing job hours. Select ">" to clear. "RESET" appears on sub-menu once hours accumulate.
2. Life Hours
"Life Hours" describes total working time and cannot be cleared.
LIFE HOURS 00000 0 HRS
3. Inlet/Outlet Temperatures
Displays inlet and outlet air temperatures and humidity.
INLET 00° 00% OUTLET 00° 00%
- "INLET00.00%": Inlet air temperature.
- "OUTLET00°00%": Outlet air temperature.
4. Humidistat Mode
Switches between humidity set point and continuous mode.
HUMIDISTAT ON> MODE
When display shows "ON", humidity can be set.
HUMIDISTAT OFF> MODE
When humidistat mode shows "OFF", the unit is in continuous mode.
5. Humidity Setpoint
Select humidity setpoint between 35% and 90%. Press ">" to increase by 5% per press.
HUMIDISTAT SETPOINT 00%
6. Temperature Measurement
Switch between °C and °F. Press ">" to switch.
TEMP UNITS C>
7. Language
Choose preferred language. Press ">" to switch between German, Spanish, and English.
LANGUAGE ENGLISH
8. Coil Temperature
Shows current coil temperature. Displays "-" if below zero.
COIL TEMP -00.0 °C
9. Compressor Current
Shows working current of the compressor.
COMPRSS CURRENT 0.00A
10. Grains Per Pound
Used to show moisture content in the air.
GRAIN DPR 0.0 GPP
Maintenance Instructions
Before Use
- Check power cord for damage (e.g., fraying). Replace if damaged.
- Check filter for dirt/obstructions. Clean or replace as necessary.
- Check coils for buildup. Clean if needed.
Cleaning the Machine Body
Use a soft, damp cloth. Do not use soap or solvents.
Filter Maintenance
- Unplug the unit.
- Slide out the filter.
- Check filter for dirt and build-up.
- For Pre-Filter or MERV-8: Clean mesh by vacuuming or washing with warm water (no soap/cleaners). Shake dry and reinsert.
- For Carbon or HEPA Filter: Replace if dirty or built-up.
Diagrams show filter removal and cleaning.
Removing the Housing
- Remove screws on housing.
- Extract screen.
- Open shell.
Diagram shows housing removal.
Coil Maintenance
- Once per year, clean coils with approved coil cleaner (e.g., WEB® Coil Cleaner).
Pump Maintenance
Pump Access:
Remove housing screws, lift off. Unplug drain line, remove pump screws.
Cleaning the Pump Reservoir:
Remove screws, lift off top of pump, set aside. Wipe base with paper towel.
Error Codes
If an issue occurs, one of the following error codes may appear:
E1 LO HI E5 E4
- E1 Error: Humidity sensor error. Unit will not work, but manual pump is available.
- LO Error: Inlet air temperature below operating range (2°F). Unit will not work, but manual pump is available. If actual temp is much higher than 33°F, replace sensor.
- HI Error: Inlet air temperature above operating range (45°F). Unit will not work, but manual pump is available. If actual temp is much lower than 113°F, replace sensor.
- E5 Error Code: Refrigerant leak. Unit runs for 30 minutes to verify, then powers off.
- E4 Error Code: Pump issue, typically high water level detected.
Troubleshooting
Symptom | Cause | Solution |
---|---|---|
Display is Blank | Poor Connection / Power Outage | Verify power cord connections. Reset power. |
No Airflow | Filter is Dirty / Air Inlet or Outlet is Blocked | Clean the filter. Clear the blockage. |
Error Code:E1 | Humidity Sensor or Communication Error | Check sensor wire connections. If no visible issues, sensor may be faulty. |
Error Code:E4 | Problem with Pump | Verify pump installation/function. Unplug unit for 2 minutes, then restart. |
Error Code:LO | Room Temperature is below 33°F | Increase room temperature to operating range (above 33°F). If error persists, check sensor. |
Error Code:HI | Room Temperature is above 105°F | Decrease room temperature to operating range (below 105°F). If error persists, check sensor. |
E5 Error Code | Refrigerant Leak | Contact your installer for assistance. |
Dehumidifier Storage
For extended storage:
- Turn off the unit and allow it to dry.
- Clean out the pump reservoir.
- Wrap and secure the power cord.
- Cover filter mesh.
- Store in a clean, dry space.
Limited Warranty
This limited warranty begins on the date of purchase. Abestorm Solutions Inc. warrants the product against manufacturing defects in material or workmanship for the following periods:
- Six (6) Month: Parts and labor (includes shipment charges for replacement parts or unit).
- One (1) year: Parts and labor (does not include shipment charge for defective product return).
- Three (3) years: Parts and labor on Refrigeration System ONLY (Compressor, Condenser, evaporator). Transportation cost not included.
- Five (5) years: Parts on Refrigeration System ONLY (Compressor, Condenser, evaporator). Transportation cost not included.
Warranty is valid for products purchased from the manufacturer or authorized dealer, operated, installed, and maintained per instructions. Abestorm Solutions Inc. does not provide in-home service. Shipping charges for service are the purchaser's responsibility.
To receive warranty service, contact Abestorm at (888)276-9833 or sales@abestorm.com. Proof of purchase or order number is required. Abestorm will repair or replace the product at its sole option.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in normal household, commercial, or noncommercial use and excludes:
- Damage from uses for which the product was not intended.
- Damage from unauthorized modification or alteration.
- Cosmetic damage (scratches, dents, chips, damage to finishes).
- Damage from abuse, misuse, pest infestation, accident, fire, floods, or acts of nature.
- Damage from incorrect electrical line current, voltage fluctuations, and surges.
- Damage from failure to perform proper maintenance.
Using the product in a SPA or a room with an OUTDOOR POOL invalidates the limited warranty.