Sungrow Energy Meter Selection Guide

The Sungrow Energy Meter presents a clear overview of energy consumption in combination with Sungrow iSolarCloud. The Sungrow Energy Meter is ideally suited for use with the Sungrow single-phase inverters and three-phase string inverters.

Compatibility and CT Requirements

TypeInverter type of applicationCT requirement
S100SG2/2.5/3K-S, SG3/5/8K-D, SH5K-20, SH5K-30No, S100 itself owns CT.
DTSU666SG2/2.5/3K-S, SG3/5/8K-D, SH5K-20, SH5K-30, SG5/10KTL-MT, SG15/20KTL-M, SG30CX, SH5.0/8.0/10RTNo, this meter integrated CT inside.
T65SH5.0/8.0/10RTNo, this meter integrated CT inside.
DTSD1352-C/1(6)ASG30CX*, SG50CX, SG110CX.
* only applicable for the phase current>80A
Yes, Sungrow meters are compatible with CTs as below:

IPD CTME-3 Series for Single Turn Primary
a. 150A, CTME3150
b. 200A, CTME3200
c. 300A, CTME3300
d. 400A, CTME3400
e. 500A, CTME3500

SOCOMEC TCA 21/TCA14 SERIES
a. 75A, TCA21-75/5
b. 80A, TCA21-80/5
c. 100A, TCA21-100/5
d. 125A, TCA21-125/5
e. 150A, TCA21-150/5
f. 200A, TCA21-200/5

SOCOMEC TCB 18 - 20 SERIES
a. 100A, 192T3310
b. 150A, 192T3315
c. 200A, 192T3320
d. 250A, 192T3325

CT Selection Criteria

Above CTs are only recommended for customers. Customers also can select the CTs by themselves.

Primary current

The CT's primary current should be equal to or greater than the maximum expected AC current from the grid, per phase. The closer the expected AC current is to the chosen primary current value, the more precise the measurement will be.

Secondary current

5 A

Accuracy class

Class 0.5 or better (Class 0.2, etc.) is recommended. Class 0.5 is equivalent to a deviation of ± 0.5% of the secondary current at maximum power.

Sungrow Energy Meter Specifications

S100 Single-phase Smart Energy Meter

A compact, DIN-rail mountable single-phase energy meter with a display screen and connection terminals.

Electrical ParameterValue
Type designationS100
Nominal voltage240 Vac
Input voltage range180 Vac - 286 Vac
Power consumption<2W (10 VA)
Max. operating current100 A
Grid frequency50 Hz
Measurement accuracyClass 1
Interface and communicationRS485
Ingress protection ratingIP20
Operating ambient temperature-25 to 75 °C
Relative humidity0 - 95 %
Dimensions (W * H * D)181 * 117 * 65 mm
Weight0.2 kg
Installation35 mm DIN-rail

T65 Three-phase Smart Energy Meter

A three-phase energy meter designed for DIN-rail mounting, featuring a display and multiple input/output terminals labeled L1, L2, L3, N.

Electrical ParameterValue
Type designationT65
Nominal voltage230 Vac / 400 Vac
Input voltage range180 Vac - 286 Vac
Power consumption<2W (10 VA)
Max. operating current65 A
Grid frequency50 Hz
Measurement accuracyClass 1
Interface and communicationRS485
Ingress protection ratingIP20
Operating ambient temperature-25 to 70 °C
Relative humidity0 - 95 %
Dimensions (W * H * D)85 * 72 * 72 mm
Weight0.4 kg
Installation35 mm DIN-rail

DTSU666 Three-phase Smart Energy Meter

A three-phase smart meter with a digital display, multiple indicator LEDs, and connection terminals. It is designed for DIN-rail mounting.

Electrical ParameterValue
Type designationDTSU666
Nominal voltage230 Vac / 400 Vac
Input voltage range57.7 / 100 Vac - 265 / 460 Vac
Power consumption< 1.5W (6 VA)
Max. operating current80 A
Grid frequency50/60 Hz
Measurement accuracyClass 1
Interface and communicationRS485
Ingress protection ratingIP20
Operating ambient temperature-30 °C - +60 °C
Relative humidity75 %
Dimensions (W * H * D)72 * 65* 100 mm
Weight0.4 kg
Installation35 mm DIN-rail

DTSD1352-C/1 (6)A Three-phase Smart Energy Meter

* DTSD1352-C/1 (6)A needs to be used with CT externally.

A three-phase smart energy meter with a digital display and connection terminals, requiring external CTs. It is designed for DIN-rail mounting.

Electrical ParameterValue
Type designationDTSD1352-C/1 (6)A
Nominal voltage230 Vac / 400 Vac
Input voltage range57.7 / 100 Vac - 268 / 464 Vac
Power consumption<2W (10 VA)
Max. operating current3×1 (6) A (via CTs)
Grid frequency50 Hz / 60 Hz
Measurement accuracyClass 0.5 (Active)
Interface and communicationRS485
Ingress protection ratingIP20
Operating ambient temperature-25 to 55 °C
Relative humidity0 - 95 %
Dimensions (W * H * D)126 * 91 * 74 mm
Weight0.35 kg
Installation35 mm DIN-rail

PDF preview unavailable. Download the PDF instead.

c32ad1fdd36c1233c649e9a20522ec47effcdb97bc5dc945fff3a6046bfc56f3 ? x tr sl=en& x tr tl=es& x tr hl=es& x tr pto=sc Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)

Related Documents

Preview Sungrow Smart Energy Meter Application Guide: S100 and DTSD1352 Models
This guide provides application details for Sungrow Smart Energy Meters, including the S100 single-phase and DTSD1352-C three-phase models. It covers inverter compatibility, current transformer (CT) requirements, and technical specifications for energy monitoring systems.
Preview Sungrow EyeM4 (WiFi) Commissioning Quick Guide for SG30/50/110CX Inverters
This quick guide provides instructions for installers on commissioning Sungrow EyeM4 (WiFi) dongles with SG30/50/110CX solar inverters, covering RS485 connections, energy meter integration, and iSolarCloud setup.
Preview Sungrow Energy Meter Selection Guide | DTSU666, DTSD1352-C/1(6)A
Comprehensive selection guide for Sungrow Energy Meters, including models DTSU666 and DTSD1352-C/1(6)A, detailing inverter compatibility and CT requirements for solar energy systems.
Preview DTSD1352-C Three-phase Energy Meter Quick Installation Guide
A quick installation guide for the DTSD1352-C three-phase energy meter, detailing its applicability, target group, intended use, technical data, delivery contents, and installation steps.
Preview Sungrow SH5K-30 Hybrid Inverter Installation and Commissioning Guide
A comprehensive guide to the installation and commissioning of the Sungrow SH5K-30 single-phase hybrid inverter, covering system components, wiring, and setup procedures for solar energy systems.
Preview Sungrow SG30/50/110CX Inverters Commissioning Quick Guide with Logger1000 and EyeM4
This guide provides step-by-step instructions for commissioning Sungrow SG30/50/110CX three-phase inverters. It covers RS485 connections, energy meter integration (DTSD1352, DTSU666), Logger1000 and EyeM4 setup, web portal access, internet connectivity (Ethernet, WiFi, 4G), remote control configuration, export control, and iSolarCloud plant creation and firmware updates.
Preview SUNGROW SH8.0RS / SH10RS 1-phase Hybrid Inverter Commissioning Guide | Setup and Configuration
Comprehensive commissioning guide for SUNGROW SH8.0RS and SH10RS 1-phase hybrid inverters, detailing system introduction, inspection, commissioning procedures, configuration via the iSolarCloud App, common parameter settings, PV plant information, FAQs, quality assurance, and contact information.
Preview Sungrow Logger1000 Quick Guide: Commissioning 3-Phase PV Inverters (5-20kW)
A quick guide for commissioning Sungrow 3-Phase PV Inverters (5-20kW) using the Logger1000. Learn about RS485 connections, web portal setup, internet connectivity, CT ratio configuration, export control, and iSolarCloud integration.