The Eaton Series DA 636 is a pressure filter designed for changeover applications, compliant with ASME-Code. It offers a working pressure up to 40 bar and can absorb pressure peaks with a sufficient safety margin. A key feature is the changeover ball valve, allowing seamless switching between two filter housings from the dirty to the clean filter side without interrupting operation. The filter element is constructed with star-shaped, pleated filter material supported by a perforated core tube and bonded with high-quality adhesive, with flow direction from outside to inside. Eaton filter elements are recognized for their high intrinsic stability, excellent filtration capability, high dirt-retaining capacity, and long service life, suitable for various hydraulic fluids and oils.

Type Index and Ordering Information

The following index details the configuration options for the DA 636 series filter. An example ordering code is DA. 636. 10VG. 30. E. P. -. FS. A. -. -. IS21. AB. OE.

Complete Filter Configuration
IndexParameterDescription
1SeriesDA = Pressure filter, changeover, acc. to ASME-Code
2Nominal Size636
3Filter Material
  • 80G, 40G, 25G, 10G: Stainless steel wire mesh
  • 25VG, 16VG, 10VG, 6VG, 3VG: Microglass
  • 25API, 10API: Microglass according to API
4Filter Element Collapse Rating30 = Δp 30 bar
5Filter Element DesignE = Single-end open
6Sealing Material
  • P = Nitrile (NBR)
  • V = Viton (FPM)
7Filter Element Specification
  • - = Standard
  • VA = Stainless steel
8Process Connection
  • FS = Flange SAE 3000 PSI
  • FA1 = Flange ANSI CLASS 300 PSI 1)
  • FA2 = Flange ANSI CLASS 300 PSI 2)
  • FA11 = Flange ANSI CLASS 150 PSI 1)
  • FA12 = Flange ANSI CLASS 150 PSI 2)
9Process Connection SizeA = 3"
10Air Bleeding/Drain Dirt Side
  • - = Standard (NPT ½")
  • FA1 = Flange ANSI ¾" CLASS 300 PSI 1)
  • FA2 = Flange ANSI ¾" CLASS 300 PSI 2)
  • FA11 = Flange ANSI ¾" CLASS 150 PSI 1)
  • FA12 = Flange ANSI ¾" CLASS 150 PSI 2)
11Filter Housing Specification
  • - = Standard
  • IS12 = Internal parts of changeover armature stainless steel (see sheet-no. 41028)
12Specification Pressure Vessel
  • IS21 = ASME VIII Div.1 with U-stamp (see sheet-no. 43415)
  • IS23 = ASME VIII Div.1 without U-stamp (see sheet-no. 55218)
13Shut-off
  • - = Without
  • AB = With shut-off block
14Clogging Indicator or Clogging Sensor
  • - = Without
  • AOR = Visual (see sheet-no. 1606)
  • AOC = Visual (see sheet-no. 1606)
  • AE = Visual-electric (see sheet-no. 1609)
  • OP = Visual (see sheet-no. 1628)
  • OE = Visual-electric (see sheet-no. 1628)
  • VS5 = Electronic (see sheet-no. 1641)

1) Sealing surface Rz = 160 µm (not finer than 40 µm)
2) Sealing surface Rz = 16 µm

Filter Element Ordering Example: 01NLM. 636. 10VG. 30. E. P. -

Filter Element Configuration
IndexParameterDescription
1Series01NLM = Standard filter element according to DIN 24550, T3 with hex nut
2Nominal Size636
3-7See Type Index - Complete Filter

Accessories:

Technical Data

ParameterValue
Operating Temperature-10°C to +100°C
Operating MediumMineral oil, other media on request
Max. Operating Pressure (Pressure Vessel)40 bar
Test Pressure (ASME VIII Div. 1)1.3 x operating pressure = 52 bar
Test Pressure (API 614, Chapter 1)1.5 x operating pressure = 60 bar
Process Connection SystemSAE-flange 3000 PSI or ANSI-flange B16.5 CLASS 150/300 PSI
Housing MaterialCarbon steel (ASTM) (see sheet-no. 69578)
Sealing MaterialNitrile (NBR) or Viton (FPM), other materials on request
Installation PositionVertical
Bleeder ConnectionNPT ½" or ANSI ¾" CLASS 150/300 PSI
Drain Connection Dirt SideNPT ½" or ANSI ¾" CLASS 150/300 PSI
Drain Connection Clean SideNPT ½"
Volume Tank2 x 6.0 l
Operating Pressure Adapter FlangesAccording to B16.5 CLASS 150 PSI (FA11/FA12 max. 16 bar)
According to B16.5 CLASS 300 PSI (FA1/FA2 max. 40 bar)

Classified under the Pressure Equipment Directive 2014/68/EU for mineral oil (fluid group 2), Article 4, Para. 3. Classified under ATEX Directive 2014/34/EU according to specific application (see questionnaire sheet-no. 34279-4).

Diagram Description

The main diagram illustrates the Series DA 636 Pressure Filter assembly. It shows two filter housings connected by a changeover valve. Key connections are labeled:

The filter operates in two positions: Position I for Filter 1 and Position II for Filter 2. A note indicates that connection for potential equalization is available for explosive areas. The switch lever can be optionally moved to the backside of the changeover valve.

Weight: Approximately 170 kg.

Dimensions: Provided in mm. Designs and performance values are subject to change.

Pressure Drop Flow Curves

Filter Calculation/Sizing: The total pressure drop (Δp assembly) is the sum of the housing pressure drop (Δp housing) and the element pressure drop (Δp element). The formula for element pressure drop is:

Δp element (mbar) = Q (l/min) × (MSK value) × (Density / 0.876 kg/dm³) × (Viscosity / 30 mm²/s)

Eaton provides a Filter Selection tool online at www.eaton.com/hydraulic-filter-evaluation for ease of calculation.

Material Gradient Coefficients (MSK) for Filter Elements: These coefficients (in mbar/(l/min)) are based on mineral oil (HLP) with a density of 0.876 kg/dm³ and a kinematic viscosity of 30 mm²/s. Pressure drop is proportional to changes in viscosity and density.

MSK Values for DA 636 Filter Elements
DA 6363VG6VG10VG16VG25VG10G25G40G80G10 API25 API
0.4360.3030.1940.1690.1150.01910.01420.01320.00910.0990.045

Δp=f(Q) – Characteristic according ISO 3968: The graph illustrates the pressure drop characteristics for the DA 636 Housing with mineral oil (HLP) at a density of 0.876 kg/dm³. Pressure drop is proportional to density. The graph shows pressure drop (Ap in bar) on the y-axis versus flow rate (Q in l/min) on the x-axis, with curves for 30 mm²/s and 100 mm²/s kinematic viscosity.

Symbols

The following symbols are used to denote filter configurations:

Spare Parts

ItemQty.DesignationDimensionArticle-No.
21Gaskets kit filter housing--
2.12O-ring120 x 3.5305146 (NBR) / 305202 (FPM)
2.22O-ring120 x 3.5305146 (NBR) / 305202 (FPM)
2.32O-ring85 x 4305685 (NBR) / 310285 (FPM)
2.44O-ring24.99 x 3.53304381 (NBR) / 305784 (FPM)
31Gasket kit of switching over consisting of:DN80 (3")354246 (NBR) / 354249 (FPM)
3.14O-ring98 x 4-
3.24O-ring110.72 x 3.53-
3.34Gasket ringDN80-
3.44O-ring34 x 3.5-
3.52Support ring40 x 34.4 x 5-
3.64O-ring74 x 3.5-
3.74O-ring10 x 2-

Test Methods

Filter elements are tested according to the following ISO standards:

Contact Information

For more information, please email us at filtration@eaton.com or visit www.eaton.com/filtration.

Eaton Global Contact Information:

© 2024 Eaton. All rights reserved. All trademarks and registered trademarks are the property of their respective owners. Information provided is based on tests believed to be reliable, but Eaton assumes no liability for its use.

Models: DA.636.10VG, DA.636.30, DA.636.E, DA.636.P, DA.636.FS, DA.636.A, Series DA 636 Pressure Filter, Series DA 636, Pressure Filter, Filter

File Info : application/pdf, 4 Pages, 428.80KB

PDF preview unavailable. Download the PDF instead.

eaton-da-636-technical-data-sheet-2258-en

References

Acrobat Distiller 25.0 (Windows)

Related Documents

Preview Eaton Series DA 106 Pressure Filter, Changeover - Technical Specifications
Detailed technical specifications, type index, and performance data for the Eaton Series DA 106 NPS 1" CLASS 150-300 PSI pressure filter, including ordering information and spare parts.
Preview Eaton BECODISC BX1 Depth Filter Modules Technical Data
Technical data sheet for Eaton BECODISC BX1 double-layer premium depth filter modules featuring BECOPAD P filter media. Details specifications, applications, selection, and handling.
Preview Eaton DA 1006 Series 3" NPS Pressure Filter Technical Data Sheet
Comprehensive technical specifications, ordering guide, and performance characteristics for the Eaton DA 1006 Series changeover pressure filter, designed for ASME applications with 3" NPS connections.
Preview Eaton DUA 2005-4005 Series Pressure Filter: Technical Specifications and Ordering Guide
Comprehensive technical data, specifications, and ordering information for the Eaton DUA 2005-4005 series of 320 PSI pressure filters, designed for hydraulic systems.
Preview BECODISC® BS Range Stacked Disc Cartridges Technical Data Sheet
Technical data sheet for Eaton's BECODISC® BS stacked disc cartridges, detailing specifications, applications, ordering information, and handling guidelines for depth filtration, sterilizing filtration, and clarifying filtration.
Preview Eaton Xiria 24 kV Ring Main Unit: The Smart Solution for Electrical Distribution
Discover Eaton's Xiria 24 kV Ring Main Unit, a compact, safe, and maintenance-free solution for substation automation and energy distribution. Learn about its vacuum technology, environmental benefits, and compliance with international standards.
Preview Eaton DUA 2005-4005 Series Pressure Filter Technical Data
Detailed technical specifications, ordering information, and performance data for the Eaton DUA 2005-4005 series pressure filters, designed for hydraulic systems with high flow rates and demanding applications.
Preview Eaton PKZM0 Circuit Breaker: Product Environmental Profile & Life Cycle Analysis
Explore the comprehensive Product Environmental Profile (PEP) for Eaton Moeller PKZM0 Motor-protective circuit breakers. This document details constituent materials, substance assessments, and detailed life cycle environmental impact indicators, including manufacturing, distribution, installation, use, and end-of-life phases.