Zoeller 912 Residential Sewage Ejector Systems

Trusted. Tested. Tough.®

Product Overview

Zoeller's 912 Residential Sewage Ejector Systems are designed for reliable sewage handling in residential and light commercial applications. These systems offer easier installation and save labor.

System Configurations:
  • 912-1161: Simplex system with a 24" x 24" Poly basin, 4 HP pump, integral float switch, and alarm.
  • 912-0017: Simplex system with a 24" x 24" Poly basin, 0.5 HP pump, piggyback float switch, and no alarm.

Consult factory or factory representative for design build package systems.

System Components

Automatic Pump

High Water Alarm (Optional)

Basin

Note: Check valve required. Sold separately.

Packing peanuts found in basins are corn starch based and will dissolve once water is added.

Optional Alarms and Alternator

Indoor APak® High Water Alarm

Indoor Residential SmartPak® Alternator

Outdoor APak® High Water Alarm

Optional Extensions and Risers

18" x 30" PSF & Fiberglass Basin Extension Options

24" X 24" Poly Basin Extension and Riser Options

System Diagram: A cross-section view illustrates the sewage ejector system installed in a residential setting, showing the basin, pump, float switch, discharge pipe, and connection to the sewer line.

Pump Performance Data

Total Dynamic Head Flow Per Minute

The following table and graph provide performance data for the 264 and 266 models.

Performance Data (Models 264 & 266)
Models Feet Meters Gal. Liters
264 266 264 266
5 1.5 90 341 115 435
10 3.0 60 227 85 322
15 4.6 23 87 45 170
Pump Performance Curve: A graph showing Total Dynamic Head (in feet) versus Flow Rate (in gallons per minute) for the 264 and 266 models. The curves illustrate the head and flow capabilities of each pump model.

912 Selection Guide

This guide helps in selecting the appropriate 912 system based on location, basin type, pump horsepower, and alarm features.

Location 10' Stack Simplex/Duplex Basin AFD Vent Basin Material Float Switch (Integral/Piggyback) Pump HP Alarm Part Number
Indoor No Simplex 24" x 24" Yes 2" Poly Integral .4 HP Yes 912-1147
Integral .4 HP No 912-1141**
Integral .5 HP Yes 912-1149
Integral .5 HP No 912-1143**
Indoor No Simplex 18" x 30" No 2" PSF Piggyback .5 HP Yes 912-1017
Piggyback .5 HP No 912-0017
Integral .5 HP Yes 912-1010
Integral .5 HP No 912-0010
Integral .4 HP Yes 912-1007
Integral .4 HP No 912-0007
Indoor No Simplex 18" x 30" No 2" Poly Piggyback .5 HP No 912-0056
Piggyback .5 HP Yes 912-1056
Integral .4 HP No 912-0055
Integral .4 HP Yes 912-1055
Indoor Yes Simplex 18" x 30" No 2" PSF Piggyback .5 HP No 912-0089
Piggyback .5 HP Yes 912-1089
Integral .4 HP No 912-0088
Integral .4 HP Yes 912-1088
Indoor Yes Simplex 18" x 30" No 2" PSF Piggyback .5 HP No 912-0087
Piggyback .5 HP Yes 912-1087
Indoor Yes Duplex 24" x 24" Yes 2" Poly Integral .5 HP Yes*** 912-1161
L.A. Code Yes Simplex 18" x 30" No 2" Fiberglass Piggyback .5 HP No 912-0020
Piggyback .4 HP No 912-0016
Outdoor No Simplex 18" x 30" No NA PSF Integral .4 HP No 912-0082
Integral .4 HP Yes 912-1082
Integral .5 HP No 912-0084
Integral .5 HP Yes 912-1084
Outdoor No Simplex 18" x 30" No NA PSF Piggyback .4 HP No 912-0083
Piggyback .4 HP Yes 912-1083
Piggyback .5 HP No 912-0085
Piggyback .5 HP Yes 912-1085

*2" Integral vent

**Can be used outdoor with 10-5157 riser

***Residential alternator

Important Safety Information

CAUTION: All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed, including the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).

Models: 912-1161, 912-0017, 912-1141, 912-1147, 912-1143, 912-1149, 912-1142, 912-1148, 912-1144, 912-1150, 912 Residential Sewage Ejector Systems, 912, 912 Sewage Ejector Systems, Residential Sewage Ejector Systems, Sewage Ejector Systems, Residential Ejector Systems, Ejector Systems, Ejector

PDF preview unavailable. Download the PDF instead.

Adobe InDesign 19.5 (Windows) Adobe PDF Library 17.0

Related Documents

Preview Zoeller Shark 803, 805, 807 Fractional HP Grinder Pumps - Residential Series
Explore the Zoeller Shark Series fractional horsepower grinder pumps (models 803, 805, 807) designed for difficult residential sewage applications. Features include cast iron construction, Tri Slice® Cutter Technology, and automatic/non-automatic options. View performance data and model comparisons.
Preview Zoeller Shark Grinder Pumps 803/805/807: Technical Data and Specifications
Detailed technical specifications, performance curves, and model comparison for Zoeller's Shark Grinder residential grinder pumps (Models 803, 805, 807).
Preview Zoeller Drain Pump Series Technical Data Sheet
Technical data sheet for Zoeller Drain Pump Series, including models 104, 105, 106, 110, 115, 120, 131, and 132. Provides specifications, performance curves, and model comparisons for various drain pump applications.
Preview Zoeller 922 Prepackage Systems: Model 820/840 Shark Series Grinder Pumps - Specifications and Selection Guide
Detailed specifications, features, and selection guide for Zoeller's 922 Prepackage Systems, including Model 820 and 840 Shark Series Grinder Pumps. Covers basin types, control panels, and performance curves.
Preview Zoeller 810 & 815 Progressing Cavity Grinder Pumps: Owner's Manual, Installation, and Operation Guide
Comprehensive owner's manual for Zoeller 810 and 815 Progressing Cavity Grinder Pumps, covering installation, operation, maintenance, safety, and troubleshooting. Includes detailed instructions and specifications.
Preview Zoeller Pump Replacement Parts List and Wiring Diagrams
Comprehensive replacement parts list and wiring diagrams for Zoeller M267, N267, D267, E267, H267, I267, J267, F267, G267, and WM267 pump models. Includes part numbers, descriptions, and electrical schematics for permanent split capacitor and split phase motor designs.
Preview Zoeller 803/805/807 Residential Grinder Pumps: Specifications and Features
Detailed specifications, features, and performance data for Zoeller's 803, 805, and 807 series residential grinder pumps. Includes motor and pump characteristics, materials, and model comparison.
Preview Zoeller 810 & 815 Progressing Cavity Grinder Pump Owner's Manual
Comprehensive owner's manual for Zoeller 810 and 815 Progressing Cavity Grinder Pumps, covering installation, operation, maintenance, safety, and troubleshooting. Includes warranty information, technical specifications, and system diagrams.