Zoeller 912 Residential Sewage Ejector Systems
Trusted. Tested. Tough.®
Product Overview
Zoeller's 912 Residential Sewage Ejector Systems are designed for reliable sewage handling in residential and light commercial applications. These systems offer easier installation and save labor.
- 912-1161: Simplex system with a 24" x 24" Poly basin, 4 HP pump, integral float switch, and alarm.
- 912-0017: Simplex system with a 24" x 24" Poly basin, 0.5 HP pump, piggyback float switch, and no alarm.
Consult factory or factory representative for design build package systems.
System Components
Automatic Pump
- Integral Float Switch or Piggyback Switch
- 115 Volt
- 0.4 HP (9.4 FLA) or 0.5 HP (10.4 FLA)
- 2" PVC discharge
High Water Alarm (Optional)
- Simplex systems are available with or without a high water alarm. Systems including a high water alarm have the alarm float preinstalled.
- Duplex systems use an alternator with a built-in high water alarm.
Basin
- Poly Structural Foam (PSF) or polyethylene basin and cover.
- 10' Stack comes with a fiberglass basin, steel cover, 4" cast iron inlet hub, and qualifies as a L.A. code system.
- 2" PVC discharge (through the cover for indoor or side discharge for outdoor systems).
- 4" Inlet
- 3/16" vent hole pre-drilled
- Available sizes: 18" x 30" (30 gallon / 113 liter capacity) and 24" x 24" (41 gallon / 155 liter capacity).
Note: Check valve required. Sold separately.
Packing peanuts found in basins are corn starch based and will dissolve once water is added.
Optional Alarms and Alternator
Indoor APak® High Water Alarm
- Auto-reset solid state alarm
- Battery backup for power outage (2-AA batteries not included)
- NEMA 1 non-corrodible enclosure for indoor use
- Manual shut-off
- Horn rated at 86 decibels at 10′ (3 m)
Indoor Residential SmartPak® Alternator
- Alternates two automatic pumps up to 1/2 HP, 12 Amps each, 115 V single phase.
- Extends pump life.
- Compact design easily mounts in confined spaces.
- Universal connection for alarm switch replacement.
Outdoor APak® High Water Alarm
- NEMA 4X Outdoor use per UL 864 for US and Canada.
- High water will trigger horn and red alarm LEDs. Audible alarm horn can be silenced. If water level recedes, alarm will stop on its own, with LED alarm indicator remaining on until reset. Horn is rated 82 decibels at 10′ (3 m).
- Auxiliary dry contacts for high level alarm, 5 Amps.
Optional Extensions and Risers
18" x 30" PSF & Fiberglass Basin Extension Options
- Poly Structural Foam (PSF): 31-1473 - 12" tall for 18" diameter; 31-1476 - 6" tall for 18" diameter
- Fiberglass: 31-0558 - 12" tall for 18" diameter; 31-0566 - 6" tall for 18" diameter
24" X 24" Poly Basin Extension and Riser Options
- 31-3108 - 8″ extension for indoor applications
- 10-5157 - 18″ riser for outdoor applications
- 31-2950 - Replacement 24″ x 24″ basin only
Pump Performance Data
Total Dynamic Head Flow Per Minute
The following table and graph provide performance data for the 264 and 266 models.
Models | Feet | Meters | Gal. | Liters | ||||
---|---|---|---|---|---|---|---|---|
264 | 266 | 264 | 266 | |||||
5 | 1.5 | 90 | 341 | 115 | 435 | |||
10 | 3.0 | 60 | 227 | 85 | 322 | |||
15 | 4.6 | 23 | 87 | 45 | 170 |
912 Selection Guide
This guide helps in selecting the appropriate 912 system based on location, basin type, pump horsepower, and alarm features.
Location | 10' Stack | Simplex/Duplex | Basin | AFD | Vent | Basin Material | Float Switch (Integral/Piggyback) | Pump HP | Alarm | Part Number |
---|---|---|---|---|---|---|---|---|---|---|
Indoor | No | Simplex | 24" x 24" | Yes | 2" | Poly | Integral | .4 HP | Yes | 912-1147 |
Integral | .4 HP | No | 912-1141** | |||||||
Integral | .5 HP | Yes | 912-1149 | |||||||
Integral | .5 HP | No | 912-1143** | |||||||
Indoor | No | Simplex | 18" x 30" | No | 2" | PSF | Piggyback | .5 HP | Yes | 912-1017 |
Piggyback | .5 HP | No | 912-0017 | |||||||
Integral | .5 HP | Yes | 912-1010 | |||||||
Integral | .5 HP | No | 912-0010 | |||||||
Integral | .4 HP | Yes | 912-1007 | |||||||
Integral | .4 HP | No | 912-0007 | |||||||
Indoor | No | Simplex | 18" x 30" | No | 2" | Poly | Piggyback | .5 HP | No | 912-0056 |
Piggyback | .5 HP | Yes | 912-1056 | |||||||
Integral | .4 HP | No | 912-0055 | |||||||
Integral | .4 HP | Yes | 912-1055 | |||||||
Indoor | Yes | Simplex | 18" x 30" | No | 2" | PSF | Piggyback | .5 HP | No | 912-0089 |
Piggyback | .5 HP | Yes | 912-1089 | |||||||
Integral | .4 HP | No | 912-0088 | |||||||
Integral | .4 HP | Yes | 912-1088 | |||||||
Indoor | Yes | Simplex | 18" x 30" | No | 2" | PSF | Piggyback | .5 HP | No | 912-0087 |
Piggyback | .5 HP | Yes | 912-1087 | |||||||
Indoor | Yes | Duplex | 24" x 24" | Yes | 2" | Poly | Integral | .5 HP | Yes*** | 912-1161 |
L.A. Code | Yes | Simplex | 18" x 30" | No | 2" | Fiberglass | Piggyback | .5 HP | No | 912-0020 |
Piggyback | .4 HP | No | 912-0016 | |||||||
Outdoor | No | Simplex | 18" x 30" | No | NA | PSF | Integral | .4 HP | No | 912-0082 |
Integral | .4 HP | Yes | 912-1082 | |||||||
Integral | .5 HP | No | 912-0084 | |||||||
Integral | .5 HP | Yes | 912-1084 | |||||||
Outdoor | No | Simplex | 18" x 30" | No | NA | PSF | Piggyback | .4 HP | No | 912-0083 |
Piggyback | .4 HP | Yes | 912-1083 | |||||||
Piggyback | .5 HP | No | 912-0085 | |||||||
Piggyback | .5 HP | Yes | 912-1085 |
*2" Integral vent
**Can be used outdoor with 10-5157 riser
***Residential alternator
Important Safety Information