Key Features
- Flat sensor with excellent space efficiency.
- Model with built-in amplifier is only 10 mm thick.
- Direct mounting onto a metallic surface is possible.
Please read Safety Precautions on page 3.
For the most recent information on models certified for safety standards, refer to the OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 4.]
Appearance | Sensing distance (Adjustable range) | Output configuration | Model/Operation mode | NO | NC |
---|---|---|---|---|---|
Flat Unshielded | 10 mm (4 to 10 mm) |
DC 3-wire NPN | E2K-F10MC1 2M | E2K-F10MC2 2M | |
E2K-F10MC1-A 2M | E2K-F10MC2-A 2M |
Ratings and Specifications
Item | Model | E2K-F10MC@-A | E2K-F10MC@ |
---|---|---|---|
Sensing distance | 10 mm (Sensing distance adjustable range: 4 to 10 mm) | 10 mm ±10% | |
Set distance | 0 to 7.5 mm * | ||
Differential travel | 15% max. of sensing distance | ||
Detectable object | Conductors and dielectrics | ||
Standard sensing object | Grounded metal plate: 50 × 50 × 1 mm | ||
Response frequency | 100 Hz | ||
Power supply voltage (operating voltage range) | 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | ||
Current consumption | 10 mA max. at 24 VDC | ||
Control output | Load current | NPN open collector, 100 mA max. (at 30 VDC) | |
Residual voltage | 1.5 V max. (Load current: 100 mA, Cable length: 2 m) | ||
Indicators | Detection indicator (red) | ||
Number of turns of sensitivity adjustment | 11 turns | ||
Operation mode (with sensing object approaching) | NO (Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.) | ||
Protection circuits | Reverse polarity protection, Surge suppressor | ||
Ambient temperature range | Operating/Storage: -10 to 55°C (with no icing or condensation) | ||
Ambient humidity range | Operating/Storage: 35% to 95% | ||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -10 to 55°C | ||
Voltage influence | ±2.5% max. of sensing distance at rated voltage at rated voltage ±10% | ||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||
Shock resistance | Destruction: 500 m/s² 3 times each in X, Y, and Z directions | ||
Degree of protection | IP64 (IEC) | IP66 (IEC) | |
Connection method | Pre-wired Models (Standard cable length: 2 m) | ||
Weight (packed state) | Approx. 35 g | ||
Case Materials | Sensing surface | Heat-resistant ABS | |
Accessories | Adjustment screwdriver, Instruction manual |
* The value for the E2K-F10MC@-A is when it is adjusted to 10 mm.
Engineering Data (Reference Value)
Sensing Area (Grounded Metal Plate)
This section presents graphs illustrating the sensing area. Graph 1 shows sensing distance (Y-axis) versus distance from the sensing head (X-axis) for detecting a grounded metal plate, indicating the detection range. Graph 2 illustrates the same for detection from the 'Up and down' perspective.
Influence of Sensing Object Size and Material
This graph demonstrates how the sensing distance is affected by the side length of the sensing object (X-axis) and the material of the object. It compares performance with grounded metal plate (t=1), non-grounded metal plate (t=10), glass (t=10), and phenol (t=10).
I/O Circuit Diagrams
Timing Chart
The timing chart illustrates the sensor's output behavior (ON/OFF) based on object presence or absence for both NO (Normally Open) and NC (Normally Closed) models. It also shows the state of the red detection indicator.
Output Circuit
The output circuit diagram shows the internal connections for the proximity sensor's output, including +V, Load, and 0V. It notes a maximum load current of 100 mA.
Safety Precautions
WARNING
⚠️ This product is not designed or rated for ensuring the safety of persons either directly or indirectly. Do not use it for such purposes.
Precautions for Correct Use
- Do not use this product under ambient conditions that exceed the ratings.
- Sensing Object Material: The E2K-F can detect almost any type of object. However, the sensing distance varies with the object's electrical characteristics (conductance, inductance, water content, capacity). Maximum sensing distance is achieved with grounded metal. Test the E2K-F with specific objects before actual application.
- Influence of Surrounding Metal: Separate the E2K-F from surrounding metal. Diagrams show recommended separation distances: 30 mm for metal objects, 60 mm and 45 mm for other configurations.
- Mutual Interference: When mounting multiple E2K-F sensors face-to-face or side-by-side, maintain separation. Diagrams show recommended distances: 40 mm for face-to-face, 50 mm for side-by-side.
- Effects of a High-frequency Electromagnetic Field: The E2K-F may malfunction near ultrasonic washers, high-frequency generators, transceivers, or portable telephones. Refer to OMRON's Noise of Warranty and Limitations of Liability for Photoelectric Sensors for measures.
- Wiring: Extending the cable does not change sensor characteristics but can cause voltage drop. Do not extend the cable length past 200 m.
- Mounting - Sensitivity Adjustment: Use the included screwdriver to adjust sensitivity. Using a different screwdriver may damage the adjuster. Refer to the Technical Guide for Operation for details.
Dimensions
All dimensions are in millimeters (mm). Tolerance class IT16 applies unless otherwise specified.
Main Unit Dimensions: The diagrams show the physical dimensions of the E2K-F sensor, including the sensing head, indicator location, and cable exit point.
Mounting Hole Dimensions: Features two holes for mounting, each M3 or 3.5 mm in diameter, with a center-to-center distance of 42±0.2 mm.
Note 1: The sensitivity adjuster is only present on the E2K-F10MC@-A models.
Note 2: The standard cable is a 2.9 mm diameter vinyl-insulated round cable with a 0.14 mm² conductor cross-section and 0.9 mm insulator diameter, with a standard length of 2 meters.
Terms and Conditions Agreement
Please read and understand this catalog before purchasing products. Consult your OMRON representative for any questions or comments.
Warranties
(a) Exclusive Warranty: OMRON warrants products to be free from defects in materials and workmanship for twelve months from the date of sale. OMRON disclaims all other warranties, express or implied.
(b) Limitations: OMRON makes no warranty or representation regarding non-infringement, merchantability, or fitness for a particular purpose. The buyer acknowledges they have determined the products' suitability for their intended use.
(c) Buyer Remedy: OMRON's sole obligation is to replace, repair, or refund the purchase price of non-complying products, provided they were handled, stored, installed, and maintained correctly. Buyer must obtain written approval for returns.
OMRON Companies are not liable for product suitability in combination with other electrical/electronic components, circuits, systems, or environments. Oral or written advice does not amend the warranty.
For published information, see http://www.omron.com/global/ or contact an OMRON representative.
Limitation on Liability; Etc.
OMRON COMPANIES ARE NOT LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, PRODUCTION, OR COMMERCIAL LOSS. Liability is limited to the individual product price.
Suitability of Use
OMRON Companies are not responsible for product conformity with standards, codes, or regulations in the buyer's application. Buyers are solely responsible for determining product appropriateness for their specific application and ensuring systems are designed to address risks, with OMRON products properly rated and installed.
Programmable Products
OMRON Companies are not responsible for user programming of programmable products or its consequences.
Performance Data
Data provided in OMRON materials is for guidance and does not constitute a warranty. Actual performance is subject to OMRON's Warranty and Limitations of Liability.
Change in Specifications
Product specifications and accessories may change due to improvements. Part numbers may be changed when ratings or features are updated. Consult OMRON representatives for confirmation of specifications.
Errors and Omissions
Information is believed to be accurate but OMRON assumes no responsibility for clerical, typographical, or proofreading errors.
OMRON Corporation, Industrial Automation Company
http://www.ia.omron.com/