⚠️ WARNING

  • Read entire manual before operation. For additional questions or concerns, contact Global Industrial Customer Service at 1-800-645-2986 or visit www.globalindustrial.com.
  • Product to be used in ambient temperatures between 60°-95°F (16°-35°C).
  • DO NOT use this product in an environment with a relative humidity greater than 93%.
  • DO NOT place this product too close to the electromagnetic range, (examples: radio, mobile phone, etc.).
  • DO NOT expose to excessive heat or water.
  • DO NOT use if product is damaged.
  • Sweat, hair, hats, or other foreign matter on the forehead can affect the accuracy of the measurement.
  • Ensure the measurement distance is within 1 to 2 inches.
  • Contact Global Industrial if there are any problems with the thermometer, DO NOT attempt to do any repairs yourself.
  • Keep this manual for future use.

Specifications

Temperature Range: 91.4°-109.4°F (33°-43°C)
Power Supply: DC 3V - 2 AAA batteries (not included)
Measuring Distance Range: 1-1/6 - 2 in.
Response Time: 1 Second
Memory Data: 20 Records
High-Fever Warning: 5 Beeps
Display: Blue LCD
Low Battery Alarm: Yes
Product Weight: 1/4 lb. (excluding batteries)
Product Dimensions: 6.1"L x 3.5"W x 1.7"H
Certification: FDA
Ambient Temp. Working Range: 60°-95°F (16°-35°C)

Component Identification

  • [1] LCD Display
  • [2] Function Button
  • [3] [+] Button
  • [4] [-] Button
  • [5] Infrared Sensor
  • [6] Measurement Trigger
  • [7] Handle
  • [8] Battery Cover

Operation Instructions

  1. Insert batteries - Open the battery cover and insert (2) AAA batteries (not included) into the bottom of the thermometer. Close the battery cover.
  2. The thermometer will beep.
  3. Tap the [Function Button] to switch between “body” and “surface” temperature modes.
  4. Press the [Measurement Trigger] to measure forehead temperature. In order to get an accurate measurement, ensure the thermometer is 1 to 2 inches away from the forehead.
  5. Press [+] or [-] buttons to review the last 20 measurement results.
  6. Press and hold the [Function Button] for 3 seconds to access the different function modes below. Tap the [Function Button] again to scroll through the following modes:
    • [F1]: °F or °C unit mode - Press [+] or [-] button to select.
    • [F2]: Max. temperature alarm mode; press [+] or [-] button to select.
    • [F3]: Display data offsetting mode; press [+] or [-] button to select.
    • [F4]: Buzzer sound activate/deactivate mode; press [+] or [-] button to select.
    Note: Pressing the [Measurement Trigger] button will exit during any set up mode.
  7. The thermometer will automatically shut-off when idle and will turn back on by pressing any button.

Product Maintenance

  • Do not use abrasive cleaners to clean this product.
  • Do not submerge the product into water or other liquids.
  • Keep the product in a dry place to avoid dust, pollution and direct sunlight.
  • Clean regularly using a dry soft cloth. If needed, use a damp cloth with water or a neutral detergent to clean, then wipe dry with a clean cloth.
Models: Non-Contact Digital Infrared Forehead Thermometer

PDF preview unavailable. Download the PDF instead.

695746 c Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview Global Industrial Non-Contact Infrared Forehead Thermometer User Manual (Model B2355238)
Comprehensive user manual for the Global Industrial Non-Contact Infrared Forehead Thermometer with Digital LED Display (Model B2355238). Learn about operation, maintenance, specifications, and troubleshooting.
Preview Global Industrial 246719 Patio Heater User Manual
User manual for the Global Industrial 246719 Patio Heater. Provides detailed safety information, installation instructions, mounting positions, remote control functions, and maintenance guidelines for this wall-mount infrared heater.
Preview Global Industrial Pharmaceutical Refrigerator Operation Manual
Operation manual for Global Industrial pharmaceutical refrigerators, covering features, installation, operation, maintenance, and safety for models 2453700, 2453701, 2453702, and 2453703.
Preview W-9 Form: Request for Taxpayer Identification Number and Certification
Official IRS Form W-9 for requesting taxpayer identification numbers and certifications from individuals and entities. Includes sections for name, address, tax classification, TIN, and certification.
Preview Global Industrial 4-Tier 12 Door Clear View Charging Locker, Digital Lock, Assembled - Assembly and Operation Manual
Comprehensive assembly and operation guide for the Global Industrial 4-Tier 12 Door Clear View Charging Locker with Digital Lock (Model 413249). Includes setup, mode selection, and functional details.
Preview Global Industrial Electric Belt Conveyor 100 lb Capacity User Manual and Specifications
User manual, specifications, assembly instructions, operating information, and warranty details for the Global Industrial Electric Belt Conveyor, models 293289 and 293290. Includes safety guidelines and troubleshooting tips.
Preview Global Industrial Red Scrub Safety Data Sheet (SDS)
Safety Data Sheet for Global Industrial Red Scrub, providing comprehensive information on product identification, hazards, composition, first aid measures, fire-fighting, accidental release, handling, storage, exposure controls, physical and chemical properties, stability, reactivity, toxicological information, ecological information, disposal considerations, transport information, and regulatory compliance.
Preview Global Industrial 412585 Indicator Instruction Manual - Setup and Calibration Guide
Comprehensive instruction manual for the Global Industrial 412585 indicator, covering installation, parameter setup, and calibration procedures for models 244241 and 244242 scales.