This guide provides essential information for the installation, operation, and maintenance of your Quest 100 dehumidifier. Proper installation and understanding of the equipment are key to successful operation and satisfaction. The dehumidifier is built using tested engineering principles and has passed thorough quality inspections.
For a complete manual, visit: QuestClimate.com/manuals
Contact: QuestClimate.com / (877) 420-1330
Assembly & Installation
Follow these steps to successfully assemble and install your new dehumidifier.
- Unpack Box: Remove all components from the packaging.
- Register Warranty: Visit ThermaStor.com/registration to register your product.
- Check Parts: Verify you have all the following parts:
- Dehumidifier (1)
- Leveling Feet (4)
- Drain Hose (1)
- Drain Adapter (1) (3/4" NPT PVC to 5/8" Hose Barb)
- Filter (1) (1" x 12" x 14")
Note: Quest dehumidifiers can operate without additional accessories, but depending on installation, extra parts might be required. Refer to Step 13 for details.
Step 4: Read all remaining steps and warnings before continuing.
Step 5: Decide Where to Place Unit in the Room
⚠️ WARNING: Do not block the airflow inlet. The outlet must be at least 61 cm (2 feet) from walls and obstructions to ensure proper airflow and performance.
⚠️ WARNING: The unit uses flammable A2L refrigerant. Refer to the manual for handling instructions and comply with national regulations.
Step 6: Choose Placement: Floor or Hanging
⚠️ WARNING: Internal stops limit leveling feet height. Do not overtighten.
A. If placing on floor: Attach leveling feet to the bottom of the dehumidifier. A height of approximately 10.16 cm (4 inches) off the ground is recommended. See manual for details.
B. If hanging dehumidifier: Use 2 brackets per unit. Brackets are sold separately. (Diagram shows an example hanging option with brackets attached to the unit.)
Setup & Connection
Step 7: Drain Setup
Insert the drain adapter and attach the drain hose to the primary drain port, located lower and nearest to the power cord. You can use the provided hose or install PVC piping to route water.
Step 8: Install Overflow Protection (Optional)
Install a normally-closed float switch to the secondary drain port for overflow protection. See manual for details.
Step 9: Output to Drain or Bucket
Route the drain hose to a suitable drain or collection bucket. See manual for more details.
Step 10: Verify Electrical Outlet
Ensure the wall outlet provides the correct voltage and amperage for the unit.
Step 11: Plug In Unit
Connect the unit to a dedicated 15 Amp circuit.
Specifications (at 26.6°C / 60% RH)
Specification | Value |
---|---|
Model | QUEST 100 (4046590-XX) |
Capacity (Liters/Day) | 44 |
Efficiency (Liters/kWh) | 3.2 |
Supply Voltage (VAC) | 230V, 50Hz |
Current Draw (Amps) | 2.5 |
Blower | 280 CFM @ 0.0'WG |
Operating Temperature | 26.6°C Min - 35°C Max |
Air Filter (MERV-13) | 30.5cm x 35.6cm x 2.5cm |
Weight (kg) | 27.2 |
Power Cord | 9', FEM IEC 60320-C13 |
Plug types supported: EU (CEE 7/7 - Type E & F), UK (BS 1363 - Type G), AUS (AS 3112 - Type I).
Operation
Step 12: Adjust Humidity
A. Setting Humidity: Use the up and down arrows on the control board to set the desired relative humidity. 50% is recommended.
B. Terminal Control: Press and release the terminal control button. The light will turn off when terminal control is active, disabling the internal RH sensor for external control use.
Control Board Functions:
- Defrost Light: Illuminates when ice is detected on coils, indicating defrosting is occurring due to cold temperatures or dry conditions.
- Terminal Control: Activates when an external control is used to manage RH. The internal RH sensor is disabled.
- Filter Reset: The button illuminates after 2,000 hours of fan operation, signaling that the filter needs changing.
- Fan: Pressing the Fan button cycles between two modes: 'Auto' (fan runs during dehumidifying) and 'On' (fan runs continuously for air circulation).
- Dark Mode: Pressing this button turns off all control lighting. The lighting remains off until any button is pressed, then stays lit for 10 seconds after the last button push. Pressing Dark Mode again while lights are on turns off Dark Mode.
C. External Controls: For external control, you can use any 24v controller or order compatible accessories as listed in Step 13.
Accessories
Purchase additional accessories at: QuestClimate.com/Product-Category/Accessories/All-Accessories/
- A. Replacement Filter: Change every 6 months or per grow cycle.
- B. Brackets: Recommended for overhead hanging installation.
- C. External Control: Ideal for overhead installation or duct work integration.
- D. Intake Duct Kit: Allows dehumidified air to be drawn from a remote area.
- E. Exhaust Duct Kit: Provides dehumidified air to a remote area.
Important Safety Instructions
Read and save these instructions.
- Install indoors in a space protected from rain and flooding.
- Ensure access to back or side panels for maintenance and service. Do not install with service panels inaccessible.
- Avoid directing discharge air at people or over water in pool areas.
- If used near water (pool, spa), ensure the unit cannot fall in, be splashed, and is plugged into a Ground Fault Interrupt (GFI) protected circuit.
- Do not use the device as a bench or table.
- Do not place the device directly on structural members; use vibration isolation to minimize noise and vibration.
- A drain pan is required under the unit if installed above a living area or where water leakage could cause damage.
- Never operate a unit with a damaged power cord. Replacement must be done by the manufacturer or qualified personnel.
- All electrical connections must comply with NEC ANSI/NFPA 70 and applicable national/local codes.
- Maintain 1 meter (3 ft) clearance around air intake and exhaust.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience/knowledge, unless supervised by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
- This appliance is not intended for use at elevations over 2000 m (6,562 ft).
⚠️ WARNING: Do not use methods to accelerate defrosting or cleaning other than those recommended by the manufacturer.
Store the appliance in a room without continuously operating ignition sources (e.g., open flames, operating gas/electric appliances).
Do not pierce or burn the unit. Be aware that refrigerants may be odorless.
Limited Warranty
Warrantor: Therma-Stor LLC, 4201 Lien Rd, Madison, WI 53704. Telephone: 1-877-420-1330.
Coverage: Extends to the original end-user of the Quest 100 dehumidifier.
First Year: Therma-Stor LLC warrants the dehumidifier to be free from defects in materials and workmanship. Therma-Stor LLC will repair or replace defective parts free of charge.
Second Through Third Year: Therma-Stor LLC warrants the condenser, evaporator, and compressor to be free from defects in material or workmanship. Therma-Stor LLC will repair or replace defective parts, but the end-user is responsible for labor and transportation charges.
End-User Responsibilities: Warranty service must be performed by an authorized Servicer. Contact Therma-Stor LLC if an authorized servicer cannot be located. Proof of purchase is required. Normal care is the end-user's responsibility. Warranty does not cover defects from misuse, abuse, lack of care, corrosion, freezing, tampering, unauthorized repairs, accidents, or acts of nature.
Limitations & Exclusions: New parts are warranted for the remainder of the original warranty period. All implied warranties (merchantability, fitness for a particular purpose) expire upon the expiration of the written warranty. Therma-Stor LLC is not liable for oral warranties. Therma-Stor LLC is not liable for special, indirect, or consequential damages, including water damage, lost profits, or loss of use.
Legal Rights: This warranty grants specific legal rights that may vary by state.
Registration: Register your new dehumidifier using the serial and part number at thermastor.com/registration or by scanning the provided code.