KEM-BS SERIES
Three Phase Superior Performance EMI Filter – Bookshelf Type Single Stage Delta Configuration
DATASHEET
Bookshelf design for motor drive applications requiring minimum space and convenient installation with superior performance at significant interference levels.
Image: Two EMI filter units shown. One labeled 'STANDARD' and the other 'NEW-DIN RAIL'.
Typical Circuit Diagram
Diagram: A schematic showing a three-phase input (L1, L2, L3) connected through a filter circuit to an output. The circuit includes inductors and capacitors, with a ground connection (E).
Features
- 3 Phase filters for Drives/invertors
- Bookshelf Design
- Chassis mounting
Applications
- Industrial Automation
- HVAC
- CNC Machines
Specifications
Electrical Characteristics
Characteristic | Value |
---|---|
Maximum Continuous Operating Voltage | 440/520VAC |
Current Ratings | 7A to 150A @40°C, Din Mount 7A to 100A @40°C |
Operating Frequency | 50/60Hz |
High Potential Test Voltage -440VAC | Line to Ground 2632VDC for 1 Minute; Line to Line 1892VDC for 1 Minute |
High Potential Test Voltage -520VAC | Line to Ground 2856VDC for 1 Minute; Line to Line 2236VDC for 1 Minute |
Overload Capability | 135% of Rated current for 15 minutes |
Functional Characteristics
Characteristic | Value |
---|---|
Operating Temperature Range | -25°C to +85°C |
Climatic Category | 25/85/21 |
Termination | Shock Proof |
Flammability corresponding to | UL 94 V-0 |
Reference Standards
Design Corresponding to | Standard |
---|---|
UL 60939-3 and CSA 22.2 No.8-13 |
Selection Table – Standard Version
TE Ordering Number | Catalog Number | Rated Current @40°C | Rated Voltage @40°C | Leakage Current (mA) | Termination | Weight (Kgs) |
---|---|---|---|---|---|---|
2-1609967-7 | 7KEMS10ABSD | 7A | 440 VAC | 5 | 41 | 0.7 |
3-1609967-0 | 16KEMS10ABSD | 16A | 440 VAC | 5 | 41 | 0.8 |
3-1609967-1 | 30KEMS10ABSD | 30A | 440 VAC | 5 | 41 | 0.8 |
3-1609967-2 | 42KEMS10ABSD | 42A | 440 VAC | 10 | 10 | 1.2 |
3-1609967-3 | 55KEMS10ABSD | 55A | 440 VAC | 10 | 10 | 2 |
3-1609967-4 | 75KEMS10ABSD | 75A | 440 VAC | 10 | 16 | 2 |
3-1609967-5 | 100KEMS10ABSD | 100A | 440 VAC | 10 | 25 | 3 |
3-1609967-6 | 120KEMS10ABSD | 120A | 440 VAC | 10 | 50 | 4 |
3-1609967-7 | 150KEMS10ABSD | 150A | 440 VAC | 10 | 50 | 4 |
5-1609967-7 | 7KEMS10BBSD | 7A | 520 VAC | 5 | 41 | 0.7 |
6-1609967-0 | 16KEMS10BBSD | 16A | 520 VAC | 5 | 41 | 0.8 |
6-1609967-1 | 30KEMS10BBSD | 30A | 520 VAC | 5 | 41 | 0.8 |
6-1609967-2 | 42KEMS10BBSD | 42A | 520 VAC | 10 | 10 | 1.2 |
6-1609967-3 | 55KEMS10BBSD | 55A | 520 VAC | 10 | 10 | 2 |
6-1609967-4 | 75KEMS10BBSD | 75A | 520 VAC | 10 | 16 | 2 |
6-1609967-5 | 100KEMS10BBSD | 100A | 520 VAC | 10 | 25 | 3 |
6-1609967-6 | 120KEMS10BBSD | 120A | 520 VAC | 1 | 50 | 4 |
6-1609967-7 | 150KEMS10BBSD | 150A | 520 VAC | 10 | 50 | 4 |
Selection Table – Din Rail Mount
Image: Three mounting options shown: 'NEW' (Din Rail Mount), 'VERTICAL MOUNT', and 'HORIZONTAL MOUNT'.
TE Part Number | Catalog Number | Din Type | Rated Current @40°C | Rated Voltage @40°C | Leakage Current (mA) | Termination | Weight (Kgs) |
---|---|---|---|---|---|---|---|
8-1609967-1 | 7KEMS10ABSDDM | DUAL | 7A | 440 VAC | 5 | 41 | 0.8 |
8-1609967-2 | 16KEMS10ABSDDM | DUAL | 16A | 440 VAC | 5 | 41 | 0.9 |
8-1609967-3 | 30KEMS10ABSDHM | HORIZONTAL | 30A | 440 VAC | 5 | 41 | 0.9 |
8-1609967-4 | 42KEMS10ABSDHM | HORIZONTAL | 42A | 440 VAC | 10 | 10 | 1.3 |
8-1609967-5 | 55KEMS10ABSDHM | HORIZONTAL | 55A | 440 VAC | 10 | 10 | 2.1 |
8-1609967-6 | 30KEMS10ABSDVM | VERTICAL | 30A | 440 VAC | 5 | 41 | 1 |
8-1609967-7 | 42KEMS10ABSDVM | VERTICAL | 42A | 440 VAC | 10 | 10 | 1.4 |
8-1609967-8 | 55KEMS10ABSDVM | VERTICAL | 55A | 440 VAC | 10 | 10 | 2.2 |
8-1609967-9 | 75KEMS10ABSDDM | DUAL | 75A | 440 VAC | 10 | 16 | 2.2 |
9-1609967-0 | 100KEMS10ABSDDM | DUAL | 100A | 440 VAC | 10 | 25 | 3.2 |
7-1609968-2 | 7KEMS10BBSDDM | DUAL | 7A | 520 VAC | 5 | 41 | 0.8 |
7-1609968-3 | 16KEMS10BBSDDM | DUAL | 16A | 520 VAC | 5 | 41 | 0.9 |
7-1609968-4 | 30KEMS10BBSDHM | HORIZONTAL | 30A | 520 VAC | 5 | 41 | 0.9 |
7-1609968-5 | 42KEMS10BBSDHM | HORIZONTAL | 42A | 520 VAC | 10 | 10 | 1.3 |
7-1609968-6 | 55KEMS10BBSDHM | HORIZONTAL | 55A | 520 VAC | 10 | 10 | 2.1 |
7-1609968-7 | 30KEMS10BBSDVM | VERTICAL | 30A | 520 VAC | 5 | 41 | 1 |
7-1609968-8 | 42KEMS10BBSDVM | VERTICAL | 42A | 520 VAC | 10 | 10 | 1.4 |
7-1609968-9 | 55KEMS10BBSDVM | VERTICAL | 55A | 520 VAC | 10 | 10 | 2.2 |
8-1609968-0 | 75KEMS10BBSDHM | DUAL | 75A | 520 VAC | 10 | 16 | 2.2 |
8-1609968-1 | 100KEMS10BBSDHM | DUAL | 100A | 520 VAC | 10 | 25 | 3.2 |
Connectors Cross Section
41 | 10 | 16 | 25 | 50 | |
---|---|---|---|---|---|
Wire Section (mm²) | 4mm² | 10 mm² | 16 mm² | 25 mm² | 50 mm² |
Wire Section (AWG) | 12AWG | 8 AWG | 6 AWG | 4 AWG | 1/0 AWG |
Wire Stripping | Max 10mm | max 13.5 mm | max 17 mm | max 17 mm | max 20 mm |
Max Recommended Torque | 0.5 Nm / 4.5 in.lbs | 1.2 Nm / 10.8 in.lbs | 2÷2.2 Nm / 18÷19.8 in.lbs | 2 Nm / 18 in.lbs | 6 Nm / 54 in.lbs |
Insertion Loss (Typical) – Measured in Closed 50Ω System
Common Mode 50Ω / 50Ω
Current Rating | 0.01 | 0.05 | 0.15 | 0.5 | 1 | 3 | 5 | 10 | 30 |
---|---|---|---|---|---|---|---|---|---|
7A | 54 | 56 | 48 | 71 | 82 | 70 | 65 | 40 | 16 |
16A | 42 | 34 | 46 | 80 | 73 | 48 | 40 | 29 | 13 |
30A | 40 | 26 | 47 | 70 | 73 | 51 | 44 | 34 | 13 |
42A | 20 | 13 | 46 | 78 | 69 | 50 | 42 | 32 | 12 |
55A | 24 | 28 | 32 | 73 | 66 | 56 | 48 | 36 | 19 |
75A | 23 | 32 | 36 | 71 | 67 | 60 | 54 | 30 | 17 |
100A | 21 | 32 | 36 | 69 | 58 | 56 | 50 | 30 | 17 |
120A | 19 | 28 | 33 | 70 | 60 | 56 | 49 | 26 | 18 |
150A | 20 | 20 | 31 | 65 | 40 | 28 | 24 | 19 | 11 |
Differential Mode 50Ω / 50Ω
Current Rating | 0.01 | 0.05 | 0.15 | 0.5 | 1 | 3 | 5 | 10 | 30 |
---|---|---|---|---|---|---|---|---|---|
7A | 30 | 32 | 40 | 69 | 54 | 50 | 48 | 34 | 25 |
16A | 28 | 30 | 42 | 79 | 81 | 58 | 43 | 8 | 22 |
30A | 28 | 21 | 37 | 76 | 82 | 67 | 49 | 20 | 28 |
42A | 18 | 21 | 35 | 83 | 74 | 64 | 45 | 13 | 27 |
55A | 22 | 30 | 34 | 69 | 70 | 58 | 40 | 49 | 22 |
75A | 38 | 40 | 45 | 86 | 81 | 68 | 50 | 49 | 35 |
100A | 36 | 40 | 47 | 80 | 75 | 62 | 54 | 50 | 35 |
120A | 32 | 35 | 45 | 78 | 72 | 60 | 54 | 47 | 31 |
150A | 31 | 30 | 34 | 48 | 39 | 28 | 23 | 17 | 15 |
Graph: Common Mode Insertion Loss (Typical in dB) for 7A and 16A current ratings, showing insertion loss across frequency from 0.01 MHz to 30 MHz.
Case Dimensions - Standard Version
Diagrams: Detailed dimension drawings for 7A, 16A, 30A, 42A, 55A, and 75A Shock Proof Type EMI filters, showing front, side, and top views with measurements in millimeters.
Case Dimensions – Din Rail Mount
Diagrams: Detailed dimension drawings for Din Rail Mount configurations: 7A Shock Proof Type - Dual Mount, 16A Shock Proof Type - Dual Mount, 30A Shock Proof Type - Horizontal Mount, 30A Shock Proof Type - Vertical Mount, 42A Shock Proof Type - Horizontal Mount, 42A Shock Proof Type - Vertical Mount, 55A Shock Proof Type - Horizontal Mount, 55A Shock Proof Type - Vertical Mount, 75A Shock Proof Type - Dual Mount, and 100A Shock Proof Type - Dual Mount. These diagrams illustrate mounting brackets and dimensions.
How to Order
The ordering code is structured as follows:
[Current Rating] KEM S [Series Type] [Filter Stage] [Termination] [Voltage] [Mounting/Type]
- Current Rating: e.g., 30A
- Series Type: KEM
- Filter Stage: S (Single), D (Dual)
- Termination: 1 (Quick Connect), 6 (Nut & Bolt), 10 (Shock Proof)
- Voltage: A (440VAC), B (520VAC)
- Mounting/Type: DM (Dual Mount), HM (Horizontal Mount), VM (Vertical Mount)
- Additional Type: STAR - D, WYE - W, Fully Potted - FP, Book Shelf - BS
Example: 30KEMS10ABSDHM indicates a 30A filter, KEM series, Single Stage, Shock Proof termination, 440VAC, Dual Mount, Horizontal Mount.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Related Documents
![]() |
TE Connectivity EJT Series High Performance Power Inlet Filters TE Connectivity's EJT Series offers high-performance power inlet filters with superior EMI filtering up to 1GHz. This guide details specifications, ordering information, performance data, and electrical schematics for the EJT Series filters. |
![]() |
TE Connectivity FASTIN-FASTON Product Line: Insulated and Uninsulated Terminals Explore the comprehensive FASTIN-FASTON product line from TE Connectivity, featuring a wide range of insulated and uninsulated terminals, receptacles, and housings. This document details specifications, part numbers, and applications for various series, including 250, 187, and 110, as well as RAST 5 tab housings. Ideal for automotive, appliance, and industrial applications. |
![]() |
TE Connectivity Heavy Duty Connectors Catalog Explore TE Connectivity's comprehensive catalog of Heavy Duty Connectors (HDC), designed for demanding industrial applications. Discover product overviews, hoods, housings, inserts, and accessories for robust power, signal, and data transmission. |
![]() |
TE Connectivity FWFU Series Fusible Wire Wound Fixed Resistors Detailed technical specifications, features, applications, construction, performance characteristics, and packaging information for TE Connectivity's FWFU Series Fusible Wire Wound Fixed Resistors. |
![]() |
TE Connectivity INS SOC ASSY 0104-202-2402 Product Information Product details for TE Connectivity's INS SOC ASSY, part number 0104-202-2402. Includes compliance information and links to available documentation. |
![]() |
TE Connectivity 1551524-2 WiFi Antenna with 210mm Cable Product details for the TE Connectivity 1551524-2 WiFi Antenna, featuring a 210mm cable. Information includes product drawings and compliance details. |
![]() |
TE Connectivity JJF Series Detector Switches - Technical Specifications and Applications Detailed information on TE Connectivity's JJF Series Detector Switches, including applications in automotive, instrumentation, white goods, and telecommunications. Features, specifications, and ordering information are provided. |
![]() |
TE Connectivity Corcom EP/VP Series Dual Stage RFI Power Line Filters TE Connectivity's Corcom EP/VP Series offers dual-stage RFI power line filters designed for switching mode power supplies. These filters provide high insertion loss and are well-suited for meeting CISPR 22 A and FCC Part 15J, Class B standards. The EP models offer very low leakage current requirements, while the 7A and 12A versions provide an optimum package size. The series includes various input/output styles and current ratings from 3A to 20A. |