RISCO Group DigiSense PIR & QUAD Detectors

Models: Digi RK415PR, Digi RK415PQ

Contact Information: RISCO Group is committed to customer service and product support. Contact them via their website (www.riscogroup.com) or through regional telephone and fax numbers listed in the original document.

Certification: EN 50131-2-2 Grade 2 Environmental Class II

Product Overview and Lens Options

The DigiSense series includes PIR and QUAD detectors designed for security applications. Available models are RK415PR and RK415PQ. These detectors support various lens types:

Both RK415PR and RK415PQ models typically use a Wide Angle lens with a range of 2m-3m (6'7"-8'10").

Detection Pattern Descriptions

RK415PR/RK415PQ Wide Angle Lens: The detection pattern shows a wide horizontal coverage (up to 90 degrees) and a detection range extending up to 10 meters. The side view illustrates detection coverage from ground level up to approximately 15 meters in height.

RK415PR Corridor Lens (LLPL02): This lens provides a focused, long-range detection pattern suitable for corridors. The top view indicates a narrow horizontal coverage, and the side view shows detection up to 15 meters in range.

RK415PR Curtain Lens (LLPL03): This lens creates a narrow, curtain-like detection beam. The top view shows a focused horizontal coverage, and the side view illustrates detection up to 15 meters in range.

Mounting

The detectors can be mounted using various methods:

Swivel Mounting Procedure:

  1. Remove the knockout plugs for the swivel mount and cable entry from the detector's base.
  2. If necessary, remove knockout plugs for cable entry from the swivel itself.
  3. Attach the swivel to the desired location on the wall or ceiling.
  4. Secure the detector base to the swivel using the provided plastic washer and screw.
  5. Feed the cables into the detector base.

Terminal Wiring

The detector features a terminal block for connections:

Note: EOL (End-of-Line) resistors can be configured for ALARM and TAMPER circuits using jumpers, with options for 1K, 2.2K, 4.7K, 5.6K, or 6.8K Ohm resistors, or no resistor.

Jumper Settings

Jumper settings configure the detector's pulse count and LED behavior:

Pulse Settings:

Important Note: For corridor (LLPL02) and curtain (LLPL03) lenses, only use the 1-pulse setting.

LED Enable/Disable:

A dedicated jumper controls the LED indicator's functionality.

LED Display

The RED LED on the detector indicates an ALARM event.

Walk Test

Perform a walk test to ensure proper operation:

  1. After applying power and allowing a 2-3 minute warm-up period, walk through the entire protected area.
  2. Verify that the detector activates correctly throughout the coverage zone.

Replacing Lenses

The detector's lens is secured by four clips on the front cover.

  1. From the inside of the cover, push each of the four clips.
  2. Lift the lens off the cover from the outside.
  3. Select the new lens, ensuring the longest pin points upwards.
  4. Align two clips on one side of the lens with the corresponding holes in the cover and push until they click into place.
  5. Repeat step 4 for the remaining two clips on the other side.
  6. Confirm all four clips are securely holding the lens and cover.

Technical Specifications

Specification RK415PR / RK415PQ
Coverage 15m x 15m (49' x 49')
Installation Height 2-3m (6'7" - 9'10")
Operating Voltage 9 to 16 VDC
Current Consumption 12mA at 12V, max 23.5 mA at 16V
Alarm and Tamper Contacts 0.1A, 24V, NC
Optical Filtering White light protection, pigmented lens
Operating Temperature -20° to +55°C (-4°F to 131°F)
Storage Temperature -20° to +60°C (-4°F to 140°F)
Dimensions 106 x 60 x 47mm (4" x 2.3" x 1.8")

RISCO Group Limited Warranty

RISCO Group warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. This warranty is limited to repairing or replacing defective products. RISCO Group is not liable for consequential or incidental damages, installation costs, or any other liabilities beyond the purchase price of the product. The product does not guarantee prevention of personal injury or property loss and is intended to reduce risk. Buyer acknowledges that a properly installed and maintained alarm system may only reduce risk, not eliminate it. RISCO Group's maximum liability is limited to the product's purchase price.

Warning: This product should be tested at least once a week.

Models: Digi RK415PR, Digi RK415PQ, DigiSense PIR QUAD Detectors

File Info : application/pdf, 2 Pages, 190.03KB

PDF preview unavailable. Download the PDF instead.

DIGI-SENSE PIR Installation Instructions

References

Acrobat Distiller 10.0.0 (Windows)

Related Documents

Preview WatchIN RK325DT Industrial Grade 3 Detector Installation Guide
Installation instructions for the RISCO Group WatchIN RK325DT Dual Technology Industrial Grade 3 Detector, covering Relay and BUS modes, mounting, wiring, DIP settings, and system parameters.
Preview DigiSense PET Digital Detector Digi 412PT Installation and Specifications
Installation guide and technical specifications for the RISCO Group DigiSense PET Digital Detector (Model: Digi 412PT), covering mounting, wiring, jumper settings, walk testing, and warranty information.
Preview RISCO Group ProSYS Plus and LightSYS 2 Security Systems Product Guide
A comprehensive product guide detailing RISCO Group's ProSYS Plus and LightSYS 2 integrated security systems, including panels, expanders, detectors, and accessories. Features and specifications for various models are provided.
Preview RISCO iWAVE RWX95P Wireless PIR Pet-Friendly Detector Installation Guide
Installation instructions and technical specifications for the RISCO iWAVE RWX95P Wireless PIR Pet-Friendly Detector. Learn about setup, mounting, battery replacement, LED indications, and warranty.
Preview Beyond Wireless DT Camera Installation Instructions
Installation instructions for the RISCO Group Beyond Wireless DT Detector and Camera, covering features, setup, configuration, and specifications.
Preview RISCO RK66S Seismic Detector Installation and Operation Manual
This document provides installation instructions, features, and specifications for the RISCO RK66S Seismic Detector, a device designed for detecting break-in attempts through vibrations and temperature monitoring.
Preview LightSYS™2 Installation and Programming Manual
Comprehensive guide for installing and programming the RISCO Group LightSYS™2 hybrid security system, covering features, communication methods, wiring, and advanced configuration.
Preview RISCO WL RWS401 External Wireless Sounder: Installation and Programming Guide
Comprehensive installation and programming instructions for the RISCO WL RWS401 External Wireless Sounder. Learn about its features, mounting, setup, and technical specifications for security systems.