Eaton Normadix (without Locknut) Cable Gland - Product Environmental Profile
This document provides a detailed Product Environmental Profile for the Eaton Normadix (without Locknut) Cable Gland.
Representative Product
Normadix PG11 N°06 N (CAP601104) Without Locknut Cable Gland
Product Description
The Eaton's Capri NORMADIX is a versatile nickel-plated brass cable gland designed for industrial and residential applications with non-armored cables. It operates within a temperature range of -5°C to +70°C and is rated IP66 for protection against dust and water. The cable gland features a Pg thread and conforms to EN 62444. It is available as a standalone product or as part of a kit with accessories.
Homogeneous Environmental Families Covered
- CAP601104-NORMADIX PG11 N°06 N (Reference)
- CAP600704-NORMADIX PG07 N°04 N
- CAP600964-NORMADIX PG09 N°5 N SANS OPERCULE
- CAP600904-NORMADIX PG09 N°05 N
- CAP610904-NORMADIX QL PG09 N°05 N
- CAP601304-NORMADIX PG13 N°07 N
- CAP601604-NORMADIX PG16 N°08 N
- CAP611104-NORMADIX QL PG11 N°06 N
- CAP611304-NORMADIX QL PG13 N°07 N
- CAP611604-NORMADIX QL PG16 N°08 N
- CAP612104-NORMADIX QL PG21 N°09 N
- CAP602104-NORMADIX PG21 N°09 N
- CAP602904-NORMADIX PG29 N°10 N
- CAP612904-NORMADIX QL PG29 N°10 N
- CAP603604-NORMADIX PG36 N°11 N
- CAP604204-NORMADIX PG42 N°12 N
- CAP613604-NORMADIX QL PG36 N°11 N
- CAP614204-NORMADIX QL PG42 N°12 N
- CAP604884-NORMADIX PG48 N°13 N
- CAP604804-NORMADIX N°48 N°13 N
- CAP614884-NORMADIX QL PG48 N°13 N
- CAP614804-NORMADIX QL N°48 N°13 N
Functional Unit
To protect the cable entry in electrical enclosures and equipment from ingression of water and dust for a lifetime of 20 years. Product shall conform to EN 62444 standard.
Company Information
Eaton Cooper Capri SAS
36 - 40 rue des Fontenils 41600, Nouan-le-Fuzelier, France
Email: productstewardship-es@eaton.com
Constituent Materials
Reference product mass (With packaging): 1.83E-02 Kg
Category PEP Material | Materials | Mass (kg) | Percentage (%) |
---|---|---|---|
Metal | Brass | 1.45E-02 | 79.3% |
Plastic | PVC | 1.06E-03 | 5.8% |
Plastic | PVC Sheet | 9.63E-04 | 5.3% |
Others | Wood | 6.19E-04 | 3.4% |
Other | Cardboard | 4.82E-04 | 2.6% |
Plastic | PE-LD film | 2.47E-04 | 1.4% |
Plastic | PE-LD | 1.85E-04 | 1.0% |
Other | Paper | 1.67E-04 | 0.9% |
Other | Glue | 2.05E-05 | 0.1% |
Metal | Nickel | 1.41E-05 | <0.1% |
Metal | Silicon | 1.28E-05 | <0.1% |
Total | 1.83E-02 | 100.0% |
Substance Assessment
The representative product is compliant with the EU-RoHS Directive (2011/65/EU) with an exemption. The product contains Lead as a Substance-of-Very-High-Concern (SVHC) on the Candidate List of the EU-REACH Regulation (1907/2006/EC).
Additional Environmental Information
- Manufacturing
- The reference product is assembled at an Eaton plant holding management system certifications according to ISO 14001 standards.
- Distribution
- Eaton is committed to minimizing product and packaging weight and volume to optimize transport efficiency.
- Installation
- The installation process requires no energy consumption, and the only waste generated is the obsolete product packaging.
- Use
- The product does not require energy consumption or maintenance during its operation.
- End of life
- The recyclability rate of the overall product is 66.08% if properly dismantled before shredding. This rate is calculated based on the “ECO’DEEE recyclability and recoverability calculation method" (version V1, 20 Sep. 2008, presented to the French Agency for Environment and Energy Management: ADEME).
Environmental Impacts
The calculation of environmental impacts is based on a Product's Life Cycle Analysis in accordance with ISO 14040/44, covering the entire lifecycle from production to end of life. System modeling was performed using the LCA software EIME v6.1.2 with database version CODDE-2023-02. Indicators Set: PEF EF 3.0 (Compliance: PEP ed.4, EN15804+A2) v2.0.
Manufacturing Phase: The product is assembled and packed at the Eaton facility in Nouan-Le-Fuzelier, France. Energy model used: France.
Distribution Phase: Product distribution within Europe is based on Eaton's logistics platform and PCR rules.
Installation Phase: Product is installed in Europe. Installation and packaging waste treatment are considered. No energy consumption for the reference product.
Use Phase: Reference lifetime: 20 years. Usage profile: No energy consumption or maintenance required during the product's useful life.
End of life Phase: Product is disposed of according to WEEE guidelines. Module D is calculated according to PCR-ed4-EN-2021 09 06, considering recycled materials and end-of-life scenarios. It expresses net benefits and loads beyond the system boundaries.
Mandatory Environmental Impact Indicators:
Environmental impact indicators | Unit | Sum | Manufacturing | Distribution | Installation | Use | End of life | Module-D |
---|---|---|---|---|---|---|---|---|
Resource use, minerals and metals (PEF-ADPe) | kg Sb eq. | 2.64E-05 | 2.38E-05 | 1.71E-10 | 4.05E-11 | 0.00E+00 | 2.59E-06 | -1.25E-05 |
Resource use, fossils (PEF-ADPf) | MJ | 1.82E+00 | 1.71E+00 | 6.07E-02 | 7.83E-03 | 0.00E+00 | 3.58E-02 | -7.00E-01 |
Acidification (PEF-AP) | mol H+ eq. | 3.49E-03 | 3.11E-03 | 2.76E-05 | 2.57E-06 | 0.00E+00 | 3.43E-04 | -1.52E-03 |
Eutrophication, freshwater (PEF-Epf) | kg P eq. | 1.32E-04 | 4.64E-05 | 1.63E-09 | 5.26E-08 | 0.00E+00 | 8.57E-05 | -2.45E-07 |
Eutrophication marine (PEF-Epm) | kg N eq. | 1.69E-04 | 1.15E-04 | 1.29E-05 | 1.42E-06 | 0.00E+00 | 3.92E-05 | -4.42E-05 |
Eutrophication, terrestrial (PEF-Ept) | mol N eq. | 1.97E-03 | 1.31E-03 | 1.42E-04 | 8.21E-06 | 0.00E+00 | 5.03E-04 | -4.98E-04 |
Climate change (PEF-GWP) | kg CO2 eq. | 1.38E-01 | 1.02E-01 | 4.36E-03 | 1.98E-03 | 0.00E+00 | 3.03E-02 | -4.02E-02 |
Climate change-Biogenic (PEF-GWPb) | kg CO2 eq. | 4.84E-03 | 3.35E-03 | 0.00E+00 | 2.54E-05 | 0.00E+00 | 1.47E-03 | -1.59E-03 |
Climate change-Fossil (PEF-GWPf) | kg CO2 eq. | 1.33E-01 | 9.82E-02 | 4.36E-03 | 1.96E-03 | 0.00E+00 | 2.88E-02 | -3.86E-02 |
Climate change-Land use and land use change (PEF-GWPlu) | kg CO2 eq. | 1.18E-07 | 4.11E-08 | 0.00E+00 | -5.64E-11 | 0.00E+00 | 7.67E-08 | 0.00E+00 |
Ozone depletion (PEF-ODP) | kg CFC-11 eq. | 2.44E-08 | 2.33E-08 | 6.67E-12 | 1.72E-11 | 0.00E+00 | 1.14E-09 | -1.23E-08 |
Photochemical ozone formation - human health (PEF-POCP) | kg NMVOC eq. | 6.98E-04 | 5.36E-04 | 3.58E-05 | 2.27E-06 | 0.00E+00 | 1.23E-04 | -2.34E-04 |
Water use (PEF-WU) | m³ eq. | 1.31E-01 | 9.21E-02 | 1.65E-05 | 2.54E-04 | 0.00E+00 | 3.86E-02 | -3.71E-02 |
Optional Environmental Impact Indicators:
Environmental impact indicators | Unit | Sum | Manufacturing | Distribution | Installation | Use | End of life | Module-D |
---|---|---|---|---|---|---|---|---|
Ecotoxicity, freshwater (PEF-CTUE) | CTUE | 1.61E+01 | 9.23E+00 | 2.93E-03 | 1.36E-02 | 0.00E+00 | 6.89E+00 | -3.04E+00 |
Human toxicity, cancer (PEF-CTUh-c) | CTUh | 2.63E-07 | 2.63E-07 | 7.65E-14 | 6.18E-11 | 0.00E+00 | 7.63E-11 | -1.46E-07 |
Human toxicity, non-cancer (PEF-CTUh-nc) | CTUh | 7.98E-08 | 7.39E-08 | 8.28E-12 | 5.62E-12 | 0.00E+00 | 5.83E-09 | -3.96E-08 |
Ionising radiation, human health (PEF-IR) | kg U235 eq. | 4.25E+00 | 4.24E+00 | 1.06E-05 | 1.15E-04 | 0.00E+00 | 1.72E-03 | -2.20E+00 |
Land use (PEF-LU) | 2.78E-01 | 9.67E-02 | 0.00E+00 | 7.35E-04 | 0.00E+00 | 1.80E-01 | -2.65E-05 | |
PF-particulate Matter (PEF-PM) | Disease occurrence | 2.19E-08 | 1.89E-08 | 2.24E-10 | 1.62E-11 | 0.00E+00 | 2.77E-09 | -8.98E-09 |
Total Primary Energy | MJ | 1.96E+00 | 1.84E+00 | 6.08E-02 | 8.59E-03 | 0.00E+00 | 5.51E-02 | -7.39E-01 |
Environmental Impact Comparison Table
The following table provides a comparison of environmental impacts for various Normadix products across different life cycle phases.
Product | Description | Phases | ADPe (kg Sb eq.) | AP (mol H+ eq.) | Ept (kg N eq.) | Epf (kg P eq.) | Epm (kg N eq.) | GWP (kg CO2 eq.) | GWPb (kg CO2 eq.) | GWPf (kg CO2 eq.) | GWPlu (kg CO2 eq.) | ODP (kg CFC-11 eq.) | POCP (kg NMVOC eq.) | WU (m³ eq.) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CAP601104 (Reference) | NORMADIX PG11 N°06 N | All Phases | 0.47 | 0.49 | 0.48 | 0.47 | 0.50 | 0.49 | 0.50 | 0.53 | 0.50 | 0.47 | 0.48 | 0.49 | 0.48 |
Manufacturing | 0.47 | 0.49 | 0.48 | 0.47 | 0.50 | 0.49 | 0.50 | 0.53 | 0.50 | 0.47 | 0.48 | 0.49 | 0.48 | ||
Distribution | 0.50 | ||||||||||||||
Installation | 0.70 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 0.47 | 0.46 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | 0.47 | ||
Module D | 0.48 | ||||||||||||||
CAP600704 | NORMADIX PG07 N°04 N | Manufacturing | 0.66 | 0.67 | 0.66 | 0.66 | 0.68 | 0.67 | 0.68 | 0.70 | 0.68 | 0.66 | 0.66 | 0.67 | 0.67 |
Distribution | 0.68 | ||||||||||||||
Installation | 0.93 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 0.64 | 0.63 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | 0.64 | ||
Module D | 0.66 | ||||||||||||||
CAP600964 | NORMADIX PG09 N°5 N SANS OPERCULE | Manufacturing | 0.67 | 0.69 | 0.68 | 0.67 | 0.69 | 0.69 | 0.69 | 0.72 | 0.69 | 0.67 | 0.68 | 0.69 | 0.68 |
Distribution | 0.70 | ||||||||||||||
Installation | 0.93 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 0.65 | 0.64 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | 0.65 | ||
Module D | 0.66 | ||||||||||||||
CAP600904 | NORMADIX PG09 N°05 N | Manufacturing | 0.94 | 0.94 | 0.94 | 0.94 | 0.94 | 0.94 | 0.94 | 0.95 | 0.94 | 0.94 | 0.94 | 0.94 | 0.94 |
Distribution | 0.94 | ||||||||||||||
Installation | 1.28 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 0.89 | 0.89 | 0.89 | 0.89 | 0.89 | 0.94 | 0.89 | 0.89 | 0.89 | 0.89 | 0.89 | 0.89 | 0.89 | ||
Module D | 0.66 | ||||||||||||||
CAP610904 | NORMADIX QL PG09 N°05 N | Manufacturing | 1.17 | 1.16 | 1.17 | 1.17 | 1.16 | 1.16 | 1.16 | 1.14 | 1.16 | 1.17 | 1.17 | 1.16 | 1.17 |
Distribution | 1.16 | ||||||||||||||
Installation | 1.21 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.14 | 1.15 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | 1.14 | ||
Module D | 1.14 | ||||||||||||||
CAP601304 | NORMADIX PG13 N°07 N | Manufacturing | 1.38 | 1.35 | 1.37 | 1.38 | 1.35 | 1.35 | 1.35 | 1.30 | 1.35 | 1.38 | 1.37 | 1.36 | 1.37 |
Distribution | 1.34 | ||||||||||||||
Installation | 1.21 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.36 | 1.37 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | 1.36 | ||
Module D | 1.35 | ||||||||||||||
CAP611104 | NORMADIX QL PG11 N°06 N | Manufacturing | 1.54 | 1.50 | 1.52 | 1.54 | 1.48 | 1.50 | 1.48 | 1.42 | 1.49 | 1.54 | 1.52 | 1.51 | 1.52 |
Distribution | 1.48 | ||||||||||||||
Installation | 2.35 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.32 | 1.33 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | 1.32 | ||
Module D | 1.37 | ||||||||||||||
CAP611304 | NORMADIX QL PG13 N°07 N | Manufacturing | 1.84 | 1.77 | 1.80 | 1.84 | 1.75 | 1.77 | 1.75 | 1.63 | 1.75 | 1.84 | 1.81 | 1.78 | 1.80 |
Distribution | 1.74 | ||||||||||||||
Installation | 3.25 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.47 | 1.49 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | 1.47 | ||
Module D | 1.54 | ||||||||||||||
CAP611604 | NORMADIX QL PG16 N°08 N | Manufacturing | 2.12 | 2.01 | 2.06 | 2.11 | 1.98 | 2.02 | 1.99 | 1.83 | 1.99 | 2.12 | 2.08 | 2.04 | 2.06 |
Distribution | 1.98 | ||||||||||||||
Installation | 3.26 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.74 | 1.77 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | ||
Module D | 1.81 | ||||||||||||||
CAP612104 | NORMADIX QL PG21 N°09 N | Manufacturing | 3.12 | 2.93 | 3.02 | 3.12 | 2.87 | 2.93 | 2.88 | 2.56 | 2.89 | 3.12 | 3.05 | 2.97 | 3.02 |
Distribution | 2.89 | ||||||||||||||
Installation | 3.26 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 1.74 | 1.77 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | 1.74 | ||
Module D | 2.82 | ||||||||||||||
CAP602104 | NORMADIX PG21 N°09 N | Manufacturing | 2.77 | 2.84 | 2.77 | 2.77 | 2.77 | 2.77 | 2.77 | 2.77 | 2.78 | 2.77 | 2.78 | 2.77 | 2.77 |
Distribution | 2.82 | ||||||||||||||
Installation | 3.60 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 3.50 | 3.58 | 3.50 | 3.50 | 3.51 | 3.50 | 3.51 | 3.50 | 3.51 | 3.50 | 3.51 | 3.51 | 3.50 | ||
Module D | 3.60 | ||||||||||||||
CAP602904 | NORMADIX PG29 N°10 N | Manufacturing | 4.61 | 4.47 | 4.49 | 4.60 | 4.36 | 4.43 | 4.39 | 4.04 | 4.40 | 4.61 | 4.52 | 4.45 | 4.49 |
Distribution | 4.53 | ||||||||||||||
Installation | 3.93 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 4.61 | 4.64 | 4.61 | 4.61 | 4.62 | 4.61 | 4.62 | 4.61 | 4.62 | 4.61 | 4.62 | 4.62 | 4.61 | ||
Module D | 4.61 | ||||||||||||||
CAP612904 | NORMADIX QL PG29 N°10 N | Manufacturing | 5.04 | 5.06 | 4.98 | 5.04 | 4.95 | 4.99 | 4.99 | 4.81 | 5.00 | 5.04 | 4.99 | 4.99 | 4.98 |
Distribution | 5.04 | ||||||||||||||
Installation | 5.24 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | 5.04 | ||
Module D | 5.02 | ||||||||||||||
CAP603604 | NORMADIX PG36 N°11 N | Manufacturing | 5.49 | 6.46 | 5.72 | 5.50 | 6.29 | 6.14 | 6.39 | 7.19 | 6.36 | 5.48 | 5.65 | 5.97 | 5.74 |
Distribution | 7.04 | ||||||||||||||
Installation | 3.98 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 8.00 | 7.47 | 7.98 | 8.00 | 7.96 | 7.97 | 7.94 | 8.00 | 7.94 | 8.00 | 7.93 | 7.96 | 7.99 | ||
Module D | 7.10 | ||||||||||||||
CAP604204 | NORMADIX PG42 N°12 N | Manufacturing | 4.39 | 8.20 | 5.71 | 4.48 | 8.37 | 7.52 | 8.59 | 12.87 | 8.44 | 4.39 | 5.33 | 6.80 | 5.79 |
Distribution | 10.46 | ||||||||||||||
Installation | 7.67 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 11.92 | 10.71 | 11.88 | 11.91 | 11.83 | 11.84 | 11.78 | 11.92 | 11.77 | 11.92 | 11.76 | 11.83 | 11.91 | ||
Module D | 10.59 | ||||||||||||||
CAP613604 | NORMADIX QL PG36 N°11 N | Manufacturing | 4.39 | 8.20 | 5.71 | 4.48 | 8.37 | 7.52 | 8.59 | 12.87 | 8.44 | 4.39 | 5.33 | 6.80 | 5.79 |
Distribution | 10.46 | ||||||||||||||
Installation | 24.16 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 8.62 | 7.96 | 8.60 | 8.62 | 8.57 | 8.58 | 8.55 | 8.62 | 8.54 | 8.62 | 8.53 | 8.57 | 8.61 | ||
Module D | 8.32 | ||||||||||||||
CAP614204 | NORMADIX QL PG42 N°12 N | Manufacturing | 5.18 | 10.71 | 6.99 | 5.30 | 10.82 | 9.64 | 11.14 | 16.91 | 10.95 | 5.17 | 6.47 | 8.59 | 7.13 |
Distribution | 14.01 | ||||||||||||||
Installation | 31.98 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 11.87 | 10.66 | 11.83 | 11.86 | 11.78 | 11.79 | 11.73 | 11.87 | 11.73 | 11.87 | 11.71 | 11.78 | 11.86 | ||
Module D | 11.17 | ||||||||||||||
CAP604884 | NORMADIX PG48 N°13 N | Manufacturing | 6.28 | 11.47 | 7.90 | 6.39 | 11.45 | 10.38 | 11.78 | 16.87 | 11.60 | 6.27 | 7.43 | 9.40 | 8.04 |
Distribution | 14.66 | ||||||||||||||
Installation | 22.83 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 13.69 | 13.14 | 13.68 | 13.69 | 13.65 | 13.66 | 13.63 | 13.69 | 13.63 | 13.69 | 13.62 | 13.65 | 13.69 | ||
Module D | 13.27 | ||||||||||||||
CAP604804 | NORMADIX N°48 N°13 N | Manufacturing | 9.74 | 13.33 | 10.57 | 9.80 | 12.89 | 12.31 | 13.21 | 15.68 | 13.13 | 9.73 | 10.32 | 11.62 | 10.70 |
Distribution | 15.87 | ||||||||||||||
Installation | 31.98 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 13.62 | 12.95 | 13.60 | 13.57 | 13.57 | 13.54 | 13.62 | 13.54 | 13.62 | 13.53 | 13.57 | 13.61 | |||
Module D | 13.31 | ||||||||||||||
CAP614884 | NORMADIX QL PG48 N°13 N | Manufacturing | 13.06 | 14.85 | 13.06 | 13.07 | 14.02 | 13.95 | 14.32 | 14.02 | 14.33 | 13.06 | 13.04 | 13.60 | 13.17 |
Distribution | 16.63 | ||||||||||||||
Installation | 33.19 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 13.88 | 13.74 | 13.87 | 13.88 | 13.87 | 13.86 | 13.88 | 13.86 | 13.88 | 13.86 | 13.87 | 13.88 | 13.87 | ||
Module D | 14.17 | ||||||||||||||
CAP614804 | NORMADIX QL N°48 N°13 N | Manufacturing | 13.92 | 15.22 | 13.70 | 13.92 | 14.29 | 14.36 | 14.58 | 13.54 | 14.62 | 13.92 | 13.75 | 14.10 | 13.81 |
Distribution | 16.80 | ||||||||||||||
Installation | 33.19 | ||||||||||||||
Use | 1.00 | ||||||||||||||
End of Life | 13.92 | 13.97 | 13.92 | 13.92 | 13.92 | 13.92 | 13.93 | 13.92 | 13.93 | 13.92 | 13.93 | 13.92 | 13.92 | ||
Module D | 14.37 |
Disclaimer
This Product Environmental Profile and its content are based on information available to Eaton. It refers to the product at the date of issue. Eaton makes no express or implied representations or warranties with respect to the information contained herein.
Registration Number: EATO-00150-V01.01-EN
Verifier accreditation Number: VH54
Date of issue: 05-2024
Drafting rules: PCR-ed4-EN-2021 0906
Supplemented by: NA
Information and reference documents: www.pep-ecopassport.org
Validity period: 5 years
Independent verification of the declaration and data, in compliance with ISO 14025: 2006: Internal [X], External [ ]
The PCR review was conducted by a panel of experts chaired by Julie Orgelet (DDomain).
PEPs are compliant with XP C08-100-1:2016 and EN 50693:2019.
The components of the present PEP may not be compared with components from any other program.
Document complies with ISO 14025: 2006 « Environmental labels and declarations. Type III environmental declarations ».