Owner's Manual for Danfoss models including: Axispro Servo Performance Proportional Valve, Servo Performance Proportional Valve, Performance Proportional Valve, Proportional Valve, Valve
File Info : application/pdf, 12 Pages, 1.86MB
DocumentDocumentService Manual Danfoss Axispro Servo conversion instructions How to get servo valve-like performance from a servo-performance Proportional valve The AxisProTM proportional industrial valve is a cost-effective and reliable alternative to the traditional servo valve. AxisProTM four-way solenoid-operated proportional valves offer high dynamic performance which enables them to be used in closed loop motion control applications previously only possible using conventional servo valves. Compared to servo valves, AxisPro proportional valves offer excellent performance and better reliability at a significantly lower price point. Servo valves: expensive with limited availability Servo valves provide excellent accuracy and high repeatability. Servo valve technology has been in constant use for over 70 years. But servo valves are typically more expensive than other valves: they require elaborate production methods (involving machining and assembling two stages). And when placed into service, servo valves require sophisticated electronic control cards--adding additional costs. In addition, servo valves require use of a pilot-filter (typically) supplied by the manufacturer, which can become contaminated and require costly maintenance. The new AxisProTM line of proportional directional valves provide a cost-effective alternative to traditional nozzle-flapper servo valves. Proportional valves, like AxisPro, benefit from a simpler mechanical design that costs less to manufacture, while utilizing onboard integrated electronics and feedback to achieve servo-quality spool control performance. Plus, since the AxisPro power stage directly drives the spool, there is increased robustness to contamination (no need for pilot stage filtration to protect the fragile nozzle-flapper interface of a traditional servo valve). AX446274262325en-000102 Converting to AxisPro servo-performance Step 3: Define conditions, output and valves: step-by-step Electrical connections NNote:Thisconversion process applies to A xisPro Level 1 valves. Contact your 1. Danfoss representative for information about converting to AxisPro Level 2 and Level 3 valves. Converting to the AxisPro valve requires a simple six-step process: Sotp 1. Determine maximum flow rate of the servo valve Sotp 2. Choose the proper replacement AxisPro valve Sotp 3. Define parameters 2. Sotp 4. Determine where motion control is handled Sotp 5. Mount AxisPro Valve Sotp 6. W ire AxisPro Valve You will find model codes, installation dimensions and other useful information in the appendix. Define the AxisPro valve failsafe condition: Servo valves typically define the failsafe condition as all ports blocked in the neutral position. Because proportional valves are driven by a solenoid in only one direction, it is necessary to match the correct failsafe condition of the servo valve in the AxisPro valve. Choose the forced position as an all ports blocked position for the new AxisPro valve. Select the AxisPro valve spool and sleeve:Spool/sleeve settings will vary according to the flow rate of the valve. Choose the correct flow when setting the valve by determining these parameters: a. Symmetric vs. Asymmetric (valves are typically symmetric, but verify with your valve) b. Correct failsafe position Step 1: Determine maximum flow r ate o f t he servo valve Maximum flow and pressure rating is typically listed as part of the model code and appears on the on the model code/serial number label (Figure 1). Note:TheA xisPro valve is not recommended for pressure ratings higher than 350 bar. c. Select flow rate. Using the spool sleeve codes, choose the correct flow rate that allows for at least the desired flow 3. Select command signal a. Select 1: +/- 10V Voltage command signal b. Select 2: 4-20mA current command signal c. Select 3: +/-10mA current command signal d. Select 4: +/-15mA current command signal e. Select 5: +/-20mA current command signal 4. Select monitor output: Use monitor output to locate the position of the valve spool for the PLC. Typical monitor output involves using the +/- 10V voltage feedback signal. The spool position may or may not be used in the existing System ignore if not used/needed by the PLC. The AxisPro valve internally controls spool position, this external feedback is optional only for monitoring purposes. a. Select 1: +/- 10V voltage feedback signal b. Select 2: 4-20mA current feedback signal Figure 1. Locate serial numberto determine flow rating. Step 2: Choose the proper AxisPro Replacement valve Choose the proper AxisPro Level 1 replacement valve according to desired flow (note single-stage AxisPro valves have flows rated at 1000 psid pressure drop across the valve, i.e. 500 psi per metering edge): · Flow < 10 gpm: choose the Danfoss KBS1-3 proportionaldirectional valve Size D03 mounting pattern · Flow > 10 gpm: choose the Danfoss KBS1-5 proportionaldirectional valve Size D05 mounting pattern To assist in choosing the right AxisPro model configuration, please refer to the appropriate AxisPro product catalogs. 5. Select electrical connection:Typical use involves the 7 pin Connector with plug a. Select E: 7 pin connector with plug Step 4: Determine where motion control is handled: PLC or card Motion is typically controlled through the servo card or through the PLC. · If motion is controlled through the servo card, talk to your Danfoss representative about using an AxisPro level 2 valve as a replacement valve · If motion is controlled through the PLC: · Ensure the PLC parameter scaling is equivalent to the AxisPro valve parameters · Verify that the PLC PID parameters are performing well/as expected 2 S t e p 5 : M o u nt t h e A x i s Pro va l ve i n p l a ce o f 4. Mount the adapter plate where the servo valve had been the servo valve located (Figure 4) 1. Verify installation dimensions for desired AxisPro valve model code a. AxisPro valves may require a larger size envelope than servo valves b. Verify there is adequate space to accommodate the AxisPro valve by measuring space around the mounted servo valve (Figure 2) Figure 2. Verify adequate space to accommodate theAxisPro valve. 2. Determine required adapter plate a. An AxisPro KBS1-3 valve requires a D03-to-S04 manifold adapter plate 1. Order a D03-to-S04 manifold adapter plate 2. Order four mounting screws: a. UNC #10-24 x 1.00 long SHCS, or b. ISO 6H M5-0.8 x 25mm SHCS mounting screws 3. Order four O-rings (typically Viton 75 Durometer-012) b. An AxisPro KBS1-5 valve requires a D05-to-S04-manifold adapter plate is required 1. Order a D05-to-S04 manifold adapter plate 2. Order four mounting screws, either: a. UNC #10-24 x 1.00 long SHCS, or b. ISO 6H M5-0.8 x 25mm SHCS c. Order four O-rings (typically Viton 75 Durometer-014) Figure 4. Mount adaptorplate to servo valve location. 5. Mount the AxisPro valve to the adapter plate (Figure 5) 3. Remove servo valve by removing the 4 mounting bolts (Figure 3) Figure 5. Mount the AxisPro valve to the adaptorplate. Figure 3. Remove the four mountingbolts to remove the servo valve. 3 Step 6. Wire the AxisPro valve Note:While no external amplifier card is needed, the AxisPro valve does require a 24VDC power supply. 1. Supply 24V volts (DC) and rated to 3.5 Amps to AxisPro valve (Figure 6 and Figure 7). a. Recommended power cable sizes for 24V are 0.75 mm2 (18 AWG) up to 20m (65 ft.) and 1.00 mm2 (16 AWG) up to 40 m (130 ft.). +24v Power Supply GND EEA-PAM-591 SM4-20 Amplifier 2. Connect input command signal from PLC to AxisPro valve. a. Command signal goes to pin D with a ground reference at pin E (Figure 8 and Figure 9). PLC +V or current in V or current GND Voltage input pins: B6, B8 or Z6 Current input pins: Z6 and Z8 EEA-PAM-591 SM4-20 Amplifier Figure 8. Before mountingthe AxisPro valve, with no external feedback. Figure 6. Wiring prior to mountingthe AxisPro valve. +24v Power Supply GND Current Amplifier No Longer Needed with AxisPro Onboard Electronics EEA-PAM-591 SM4-20 Amplifier A G F B C PLC +V or current in V or current GND Voltage input pins: B6, B8 or Z6 Current input pins: Z6 and Z8 EEA-PAM-591 SM4-20 Amplifier A G F B C E D 7-pin Amphenol AxisPro Connector Figure 9. After mountingthe Level 1 AxisPro valve. E D 7-pin Amphenol AxisPro Connector Figure 7. Wiring after mountingthe AxisPro valve. 4 Model Code KBS1 - 03 - ** - NS - ** - * - NS - 004 - 11 12 3 4 5 67 8 13 14 15 1 Valve Type KBS Servo performance proportional valve with integral amplifier and electronic feedback 2 Control Level Level 1 3 Interface 03 ISO 4401, size 03-02-0-94 ANSI/B93.7M-D03 4 Spool/Sleeve 1 Symmetric -40min - At Failsafe -all ports blocked (legacy 92L40) 2 Symmetric -24min - At Failsafe -all ports blocked (legacy 92L24) 3 Symmetric -12min - At Failsafe -all ports blocked (legacy 92L12) 4 Symmetric -05min - At Failsafe -all ports blocked (legacy 92L05) 5 Symmetric -40min - At Failsafe -P port blocked, A,B,T connected (legacy 96L40) 6 Symmetric -24min - At Failsafe -P port blocked, A,B,T connected (legacy 96L24) 7 Symmetric -12min - At Failsafe -P port blocked, A,B,T connected (legacy 96L12) 8 Symmetric -05min - At Failsafe -P port blocked, A,B,T connected (legacy 96L05) 9 Symmetric -40min - At Failsafe reduced flow A connected to T and B connected to P(legacy 94L40) 13 Symmetric -40min reduced pressure at null At Failsafe -P port blocked, A,B,T connected (legacy 86L40) 17 Asymmetric -40min A; 20min B - At Failsafe -all ports blocked (legacy 92L40N20) 18 Asymmetric -40min A; 10min B - At Failsafe -all ports blocked (legacy 92L40N10) 19 Asymmetric -24min A; 12min B - At Failsafe -all ports blocked (legacy 92L24N12) 20 Asymmetric -40min A; 20min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L40N20) 21 Asymmetric -40min A; 10min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L40N10) 22 Asymmetric -24min A; 12min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L24N12) 23 2-gain Symmetric 4min @ 40% - 40min @100% - At Failsafe -all ports blocked (legacy 92L04T40) 24 2-gain Symmetric 2.4min @ 60% -24min @100% - At Failsafe -all ports blocked (legacy 92L02T24) 25 2-gain Symmetric 1.5min @ 60% -15min To find available product configurations go to www.danfoss.com @100% - At Failsafe -all ports blocked (legacy 92L01T15) 26 2-gain Symmetric 4.0min @ 40% -40min @100% - @Failsafe -P port blocked, A,B,T connected (legacy 96L04T40) 27 2-gain Symmetric 2.4min @ 60% -24min @100% - @Failsafe -P port blocked, A,B,T connected (legacy 96L02T24) 28 2-gain Symmetric 1.5min @ 60% -15min @100% - @Failsafe -P port blocked, A,B,T connected (legacy 96L01T15) 29 2-gain Symmetric 2.4min @ 40% -24min @100% - @Failsafe -P port blocked, A,B,T connected 30 2-gain Symmetric 1.5min @ 40% -15min @100% - @Failsafe -P port blocked, A,B,T connected 31- symmetric 40 lpm 8% overlap failsafe P, A, B, blocked 32- symmetric 20 lpm 8% overlap failsafe P, A, B, blocked 33 - symmetric 10 lpm 8% overlap failsafe P, A, B, blocked 34- symmetric 05 lpm 8% overlap failsafe P, A, B, blocked 35 - symmetric 40 lpm 8% overlap failsafe P, blocked A, B, T connected 36 - symmetric 20 lpm 8% overlap failsafe P, blocked A, B, T connected 37- symmetric 10 lpm 8% overlap failsafe P, blocked A, B, T connected 38- symmetric 05 lpm 8% overlap failsafe P, blocked A, B, T connected 39- symmetric 14 lpm 8% overlap failsafe P, A, B, blocked 40 - symmetric 14 lpm 8% overlap failsafe P, P, blocked A, B, T connected 5 Valve Special Feature NS Not Selected 6 Command Signal 1 +/- 10V voltage command signal 2 +/- 4-20mA current command signal 3 +/- 10mA current command signal 4 +/- 15mA current command signal 5 +/- 20mA current command signal 7 Monitor Output 1 ±10V voltage feedback signal 2 4-20mA current feedback signal 8 Electrical Connection C 7 pin connector without plug E 7 pin connector with plug H As E but with pin "C" used for enable signal R As C but with pin "C" used for enable signal 13 Electrical Special Feature NS Not Selected 14 Software Revision XXX Software Revision 15 Design Number 11 series 4 AxisPro Proportional Directional Valves with Feedback KBS*-03 E-VLPO-MC002- Model Code KBS1 - 05 - ** - NS - ** - * - NS - 004 - 11 12 3 4 5 67 8 13 14 15 1 Valve Type KBS Servo performance proportional valve with integral amplifier and electronic feedback 2 1 Level 1 3 Interface 05 ISO 4401, size 05-04-0-05 ANSI/B93.7M-D05 4 Spool/Sleeve 1 Symmetric -100min - At Failsafe -all ports blocked (legacy 92L100) 2 Symmetric - 80min - At Failsafe -all ports blocked (legacy 92L80) 3 Symmetric - 50min - At Failsafe -all ports blocked (legacy 92L50) 4 Symmetric - 25min - At Failsafe -all ports blocked (legacy 92L25) 5 Symmetric -100min - At Failsafe -P port blocked, A,B,T connected (legacy 96L100) 6 Symmetric - 80min - At Failsafe -P port blocked, A,B,T connected (legacy 96L80) 7 Symmetric - 50min - At Failsafe -P port blocked, A,B,T connected (legacy 96L50) 8 Symmetric - 25min - At Failsafe -P port blocked, A,B,T connected (legacy 96L25) 17 Asymmetric -100min A; 70min B - At Failsafe -all ports blocked (legacy 92L100N70) 18 Asymmetric -100min A; 50min B - At Failsafe -all ports blocked (legacy 92L100N50) 19 Asymmetric -100min A; 25min B - At Failsafe -all ports blocked (legacy 92L100N25) 20 Asymmetric - 50min A; 25min B - At Failsafe -all ports blocked (legacy 92L50N25) 21 Asymmetric -100min A; 70min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L100N70) 22 Asymmetric -100min A; 50min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L100N50) 23 Asymmetric -100min A; 25min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L100N25) 24 Asymmetric - 50min A; 25min B - At Failsafe -P port blocked, A,B,T connected (legacy 96L50N25) 25 2-gain Symmetric 10min @ 40% -100min @100%@Failsafe -all ports blocked (legacy 92L10T100) 26 2-gain Symmetric 5min @ 40% - 50min @100%@Failsafe -all ports blocked (legacy 92L05T50) 27 2-gain Symmetric 10min @ 40% -100min @100%@Failsafe -P port blocked, A,B,T connected (legacy 96L10T100) 28 2-gain Symmetric 5min @ 40% - 50min @100%@Failsafe -P port blocked, A,B,T connected (legacy 96L05T50) 5 Valve Special Feature NS Not Selected 6 Command Signal 1 +/- 10V voltage command signal 2 +/- 4-20mA current command signal 3 +/- 10mA current command signal 4 +/- 15mA current command signal 5 +/- 20mA current command signal 7 Monitor Output 1 ±10V voltage feedback signal 2 4-20mA current feedback signal 8 Electrical Connection C 7 pin connector without plug E 7 pin connector with plug H As E but with pin "C" used for enable signal R As C but with pin "C" used for enable signal 13 Electrical Special Feature NS Not Selected 14 Software Revision XXX Software Revision 15 Design Number 11 series To find available product configurations go to www.danfos s .com 4 AxisPro Proportional Directional Valves with Feedback KBS*05 E-VLPO-MC003-E3 Installation dimensions KBS1-03 7 - Pin connector 126.9 [5.00] 46.0 [1.81] 21.75 [0.86] KBS1-05 144.82 [5.7] 69.6 [2.74] 29.75 [1.2] 13.75 [0.54] 236.83 [9.32] 214.8 [8.46] 146.53 [5.8] 7 - Pin Connector 238.40 [9.4] 21.50 [0.85] 70.48 [6.71] 266.33 [10.49] 7 Mountingsurfaces KBS1-03 Mounting Surfaces to ISO 4401 (Size 03) This interface conforms to: ISO 4401-03-02-0-94 plus location pin hole ANSI/B93.7M (and NFPA) size 03 CETOP R35H4.2-4-03, plus location pin hole DIN 24340 Form A6 plus location pin hole 4 holes, M5-6H x 12 (0.47) min.full threaddepth 5,1 (0.20) 15,5 (0.61) 25,9 (1.01) 31,0 0,1 (1.22 0.004) 4portsØ6,3 (0.25 dia). Forall Danfosssize 03valves this diametermaybeincreased toØ7,5 (0.29) Ø4,0 x4,3 min.depth(0.16dia x0.17) for locatingpin 30,2 (1.18) 21,5 (0.85) 12,7 (0.5) T A B P 0,75 0,1 (0.03 0.004) 31,75 0,1 (1.25 0.004) 7,5 (0.29) 40,5 0,1 (1.59 0.004) 48 (1.89) min. 70 (2.75) min. #10-24 UNC-2B optional. KBS1-05 Mounting Surface Interface to ISO 4401 (Size 05) This interface conforms to: ISO 4401-05-04-0-05 ANSI/B93.7M (and NFPA) size 05 CETOP R35H4.2-05 DIN 24340 Form A10 32,5 (1.28) 21,4 (0.84) 50,8 (2.0) 37,3 (1.47) 6,3 (0.25) 27,0 (1.06) 16,7 (0.66) 3,2 (0.12) P A B 5 ports Ø 11,2 (0.44 dia) including opt. tank port 1/4"-20 UNC-2Boptional. TA TB 54,0 ±0,1 (2.12 ±0.004) 90,0 (3.54) min. 4 holes, M6-6H x 16 (0.63) min. full thread depth 69,0 (2.72) min. 46,0 ±0,1 (1.81 ±0.004) Optional port(TB) 0,5 (0.02) Ø3,0 (0.12 dia) 11,0 (0.433) P LA B TA TB 8 Operating Data Connector Details 7-pin plug connector A F E Pin Description G A Power supply positive (+) B Power supply 0V and current command return BC Not connected (Field 8 = C,E) C Valve enable (Field 8 = H,R) D Command signal (+V or current in) C E F Command signal (-V or current GND) Output monitor D G Protective earth M12 5-pin CAN Connector (Male) 4 5 1 3 Pin Description 1 CAN shield 2 Not Connected 3 Power supply 0V 4 CAN High 5 CAN Low 2 M12 5-pin CAN Connector (Female) 2 5 1 3 Pin Description 1 CAN shield 2 Not Connected 3 Power supply 0V 4 CAN High 5 CAN Low 4 M12 8-pin External Digital Sensor 6 7 5 8 4 1 3 2 M12 8-pin External Analog Sensor Port 6 7 5 8 4 1 3 2 Pin Description 1 Power supply 0V 2 +24V Supply 3 CLK- 4 DATA- 5 DATA+ 6 Not Connected 7 CLK+ 8 Not Connected Pin Description 1 Speed Sensor Input1 2 Speed Sensor Input2 3 4-20mA External Sensor Signal1 4 +15V Supply 5 4-20mA External Sensor Signal2 6 Power supply 0V 7 4-20mA External Sensor Signal3 8 4-20mA External Sensor Signal4 M12 4-pin Ethernet Connector (Female) 2 1 3 Pin Description 1 TxD+ 2 RxD+ 3 TxD- 4 RxD- 4 Note: Present at location 1 of the electronics enclosure (see figure 1 below). To ensure EMI protection use only metal shielded mating connectors. Mating 7-pin (connector) is Danfoss part number 934939 Note: Present at location 2 and 4 of the electronics enclosure (see figure 1 below). Selection based on model code field number 9, present when CO option enabled. To ensure EMI protection use only metal shielded mating connectors Use only shielded twisted pair (STP) cables for mating connection. Note: Present at location 5 of the electronics enclosure (see figure 1 below). Selection based on model code field number 9, present when CO option enabled. To ensure EMI protection use only metal shielded mating connectors Use only shielded twisted pair (STP) cables for mating connection. Note: Present at location 3 of the electronics enclosure (see figure 1 below). Selection based on model code field number 10, present when D option enabled. To ensure EMI protection use only metal shielded mating connectors 24V to Power supply 0V (pin 2, 1) short circuit protected (max current 1.5 A). Use only shielded twisted pair (STP) cables for mating connection. Note: Present at location 3 of the electronics enclosure (see figure 1 below). Selection based on model code field number 10, present when A option enabled. To ensure EMI protection use only metal shielded mating connectors 15V to Power supply 0V (pin 4, 6) short circuit protected (max current 500 mA). Note: Present at location 4 and 5 of the electronics enclosure (see figure 1 below). Selection based on model code field number 9, present when PN,EC or E T option enabled. Location 4 is Ethernet Channel 0 Location 5 is Ethernet Channel 1 M12 connector is D-Coded To ensure EMI protection use only pre made CAT5 or CAT 6 cable 12 AxisPro Proportional Directional Valves with Feedback KBS*-03 E-VLPO-MC002- Operating Data Data is typical, with fluid at 32 cST (150 SUS) and 40°C (104°F) Diagnostic Color A [Green] B [Red] C [Green] D [Red] E [Green] Electromagnetic compatibility (EMC): Monitor Points Signal: Voltage mode Current mode Output impedance Power stage PWM frequency Reproducibility, valve-to-valve (at factory settings): Flow gain at 100% command signal Protection: Electrical Ambient air temperature range for full performance Oil temperature range for full performance Minimum temperature at which valves will work at reduced performance Storage temperature range Power supply Command Signal: Voltage mode Input impedance Voltage between Pin D and B Voltage between Pin E and B Current mode Max differential voltage to pin E to pin B Valve enable signal for model code field 8 = H or R Enable Disable Input impedance Sensor Resolution: External Sensor Port Integrated Pressure and Temperature Sensors Amplifier Temperature Sensing Power Supply Detect Description CO Power CAN Error CAN Run Diagnostic Status PN ET Power Power PN Diagnostic (SF) ET Module Status Valve Diagnostic PN Network Status (BF) Valve Status Valve Diagnostic ET Network Status Valve Status EC Power EC Error EC Run Valve Diagnostic Valve Status Note: 1. Figure to the left references the clear plastic window on the top of the valve. LED status depends on Network option choosen (CO/PN/ET/EC. IEC61326-1 2021 ±10V DC 4 to 20 mA 10 k 20 kHz nominal 5% Reverse polarity protected between pin A and B of the 7 pin plug connector 25°C to +85°C (13°F to +185°F) CN version -25°C to 70°C PN version 0°C to +60°C (32°F to +140°F) 20°C (4°F) 25°C to +85°C (13°F to +185°F) 24V DC (18V to 36V including 10% peak-to-peak max ripple) max current 3,7A 10V to +10V DC 13 bit resolution, ± 1% Field 6 = 1: 47k, Field 6 = 2,3,4,5: 100 Field 6 = 1:18v (max) Field 6 = 1:18v (max) Field 6 = 2,3,4,5: 13 bit resolution based on ±20mA, ±1%Field 6 = 2,3,4,5: 100 mV Disable <6.5V Enable Signal >8.5V (max 36V) 10 k 4-20 mA: 0-20mA 12 bit resolution ± 1%, 3mA cable break detect, 22mA overcurrent detect. Speed, independent frequency mode: 10Hz to 100 kHz. Speed, incremental count and direction + frequency mode: signed 32bit count, 0 to 100 kHz. Speed, quadrature phase A&B + frequency mode: signed 32 bit count, 0 to 100 kHz. SSI: binary or gray code, 32bits max, adjustable resolution and zero offset. Integrated PCB temperature sensor accuracy: ± 2°C For Level 3 valves: Integrated Pressure sensors on all ports Pressure sensors rated to 400bar Integrated Pressure sensors accuracy: ± 0.5% of full scale Bandwidth: >100 Hz Integrated temperature sensor on tank port Accuracy: ± 5°C Bandwidth: ~1 Hz 1°C (1.8°F) resolution, -25°C (-13°F) undertempdetect, 125°C (257°F) overtemp detect 18-36Vdc, 0.01 V resolution ± 1%, 19V under voltage detect, 36V overvoltage AxisPro Proportional Directional Valves with Feedback KBS*-03 E-VLPO-MC002- 13 Operating Data KBS*-03 Valves (all valves) Relative duty factor Hysteresis Mass Environmental Step response: Step, % Flow 0% to 100%, 100% to 0% 10% to 90%, 90% to 10% -10% to 10%, 10% to -10% 25% to 75%, 75% to 25% Parts Information: Interface Seal Kits Mating Electrical 7-pin Connector Location 1 Location 2 Continuous rating (ED = 100%) <0.1% 2.49 kg (5.5 Ib) approx. IP65 and IP67 rated when using a similarly rated connector Location 2, 3, 4 and 5 connectors have IP65 and IP67 rated shipping covers ms 8.0 8.0 7.0 7.0 02-147573 934939 Location 3 Location 4 Location 5 Figure 1 Note: See above for connector plugs specifications. 14 AxisPro Proportional Directional Valves with Feedback KBS*-03 E-VLPO-MC002- Products we offer: · Cartridge valves · DCV directional control valves · Electric converters · Electric machines · Electric motors · Gear motors · Gear pumps · Hydraulic integrated circuits (HICs) · Hydrostatic motors · Hydrostatic pumps · Orbital motors · PLUS+1® controllers · PLUS+1® displays · PLUS+1® joysticks and pedals · PLUS+1® operator interfaces · PLUS+1® sensors · PLUS+1® software · PLUS+1® software services, support and training · Position controls and sensors · PVG proportional valves · Steering components and systems · Telematics Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electric components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster. Danfoss Power Solutions your strongest partner in mobile hydraulics and mobile electrification. Go to www.danfoss.com for further product information. We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components. Local address: Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com Danfoss Power Solutions (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions Trading (Shanghai) Co., Ltd. Building #22, No. 1000 Jin Hai Rd Jin Qiao, Pudong New District Shanghai, China 201206 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.