DataMan® 8700 Quick Reference Guide

February 24, 2021
Revision: 6.2.1.1

The Cognex logo is a stylized representation of the company name.

An image shows the DataMan 8700 handheld barcode reader.

Precautions

To reduce the risk of injury or equipment damage, observe the following precautions when installing the Cognex product:

Product Overview

An image displays three views of the DataMan 8700 DX Reader with numbered callouts.

Callout Component
1 LED aimer
2 Trigger (press and hold to read)
3 Cable insertion point
4 360° ring light indicator
5 Lanyard hook
6 OLED display
7 OLED input and configuration buttons
8 Diffused light
9 Polarized light
10 Direct light

DataMan 8700 Accessories

Accessory Name Product ID Illustration
Power Supply for reader DM8700-PWR-00 [Illustration]
POE adapter CPS-24V-POE1 [Illustration]
POE adapter CPS-24V-POE4 [Illustration]
POE adapter CPS-AC-POE1A-xx* [Illustration]
Wall Mount Bracket DMA-WALL-8700 [Illustration]
Presentation Stand, can be used with wall mount bracket (DMA-WALL-8700) DM-STAND-00 [Illustration]

*xx can be US, EN, UK, or JP.

Cables

Accessory Name Product ID Illustration
RS-232 coiled cable for Reader, 2.5 m with Dsub-9 connector, power over pin 9 DMC-HH-RS232P-02C [Illustration]
RS-232 coiled cable for Reader, 2.5 m with Dsub-9 connector DMC-HH-RS232-02C [Illustration]
RS-232 coiled cable for Reader, 4 m with Dsub-9 connector DMC-HH-RS232-05C [Illustration]
RS-232 Firmware update cable, RS-232 to USB converter DMC-HH-RS232-USB [Illustration]
USB straight cable, 2.5 m with USB type-A connector DMC-HH-USBA-02 [Illustration]
USB coiled cable, 2.5 m with USB type-A connector DMC-HH-USBA-02C [Illustration]
USB cable, type C connector, straight, 2.5 m DMC-HH-USBC-02 [Illustration]
USB cable, type C connector, coiled, 2.5 m DMC-HH-USBC-02C [Illustration]
Ethernet coiled cable with RJ45 connector, 5 m DMC-HH-ENET-05C* [Illustration]
Ethernet straight cable with RJ45 connector, 2.5 m DMC-HH-ENET-02* [Illustration]
Ethernet straight cable with RJ45 connector, 5 m DMC-HH-ENET-05 [Illustration]
Ethernet straight cable with RJ45 connector, 30 m DMC-HH-ENET-30 [Illustration]
Ethernet coiled cable, 5 m with M12 X-coded connector DMC-HH-ENETM12-05C [Illustration]

*Collimated cable length including DM8700-ECABLE-X should not exceed 50 m.

Field of View and Reading Distances

An illustration shows a pyramid representing the field of view of the DataMan 8700 reader, with working distances Z1, Z2, Z3 and corresponding horizontal (X) and vertical (Y) values at each level.

Working Distance Horizontal Values Vertical Values
Z₁ = 40 mm (1.5 in) X₁ = 63 mm (2.5 in) Y₁ = 47 mm (1.8 in)
Z₂ = 140 mm (5.5 in) X₂ = 126 mm (5 in) Y₂ = 95 mm (3.7 in)
Z₃ = 300 mm (11.8 in) X₃ = 288 mm (11.3 in) Y₃ = 171 mm (6.7 in)

Depth of Field values

Distances in mm / 1D min code Distances in mm / 2D min code
18-58 3 MIL 10-71 5 MIL
10-175 10 MIL 10-155 10 MIL
0-650 50 MIL 0-650 50 MIL
0-1000 100 MIL 0-1000 100 MIL

Note: All values beginning with 0 denote the minimum distance where the Field of View is able to see the entire code.

Connecting the Reader

  1. Use a small screwdriver or a pencil to press in the gray tab by the cable insertion.
  2. Turn the cable insertion mechanism to an open position.
  3. Insert the cable.
  4. Lock the cable.

An image illustrates the four steps for connecting a cable to the DataMan 8700 reader.

Note: Disconnect the DataMan 8700 from power before inserting the communication modules.

Installation

Installation procedures are detailed in the DataMan DM8700 Reference Manual, which is installed with the DataMan Setup Tool. From the Windows Start menu, select the following to access the manual: All Programs > Cognex > DataMan Software vX > Documentation.

Note:

CAUTION: All cable connectors are "keyed" to fit the connectors on the DataMan system; do not force the connectors or damage may occur.

Install Software, Documentation and Connect the Reader

To configure a DataMan 8700 reader, the DataMan Setup Tool software must be installed on a PC on the network. The DataMan Setup Tool is available from the DataMan support site: cognex.com/support/dataman.

  1. After installing the software, connect the DataMan 8700 to your PC.
  2. Launch the DataMan Setup Tool and click Refresh.
  3. Select your DataMan 8700 reader from the list and click Connect.

DataMan 8700 DX Specifications

Specification DataMan 8700 DX Reader
Weight 450 g (15.90 oz) + ~130 g (4.59 oz) cables
Operating Temperature 0°C - 40°C (32°F - 104°F)
Storage Temperature -40°C - 60°C (-40°F - 140°F)
Maximum Humidity <95 % (non-condensing)
Environmental ISO 16750-5 Compliant with latest EU RoHS and China RoHS. For indoor use only.
Symbologies 1-D barcodes: Codabar, Code 39, Code 128, Code 93, Interleaved 2 of 5, Postal, UPC/JAN, POSTNET, PLANET Code, GS1 IMB
2-D barcodes: MaxiCode, Aztec Code, Data Matrix™, QR Code and microQR Code, PDF 417
Power Supply Requirements Serial/USB: 5.5 V DC, 6.0 W maximum LPS or NEC Class 2 power supply
Ethernet: PoE Class 2 power supply
Inrush current peak In DC and USB mode: 3 A maximum
Maximum capacity: 10 μF
Maximum inrush: 50 μC
Ethernet 10/100 Base-T FULL/HALF DUPLEX, IEEE 802.3
Protection ISO 16750-5
IP67
Endures multiple drops from 2.5 m height on concrete

LED Wavelengths for DataMan 8700DX Reader

The following table shows LED types and their related wavelengths:

LED λ[nm]
RED 660

Regulations and Conformity

The corded DataMan 8700 DX has Regulatory Model R00083 that meets or exceeds the requirements of all applicable standards organizations for safe operation. Please read the following guidelines carefully before using your device.

Note: For the most current CE declaration and regulatory conformity information, see the Cognex support site: cognex.com/support.

The following specifications apply to the corded DataMan 8700 DX readers:

Regulator Specification
USA FCC Part 15B, Class A
Canada ICES-003
European Community EN 61326-1
Safety and Regulatory Manufacturer: Cognex Corporation, One Vision Drive, Natick, MA 01760 USA
Corded DataMan 8700 DX: Regulatory Model R00083. This is a class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take immediate measures. This equipment complies with the essential requirements of the EU Directive 2014/30/EU. Declarations are available from your local representative.
EU RoHS Compliant to the most recent applicable directive.
Safety and Regulatory FCC Part 15, Class A. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Canadian Compliance This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
TÜV Corded DataMan 8700: Regulatory Model R00083. NRTL: TÜV SÜD SCC/NRTL OSHA Scheme for UL/CAN 61010-1. CB report available upon request. TÜV SÜD IEC/EN 61010-1.

For European Community Users

Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE).

This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment if not properly disposed.

In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. These systems will reuse or recycle most of the materials of the product you are disposing of in a sound way.

The crossed out wheeled bin symbol [symbol of a crossed-out trash bin on wheels] informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal.

If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performance of this product.

中国大陆RoHS (Information for China RoHS Compliance)

根据中国大陆《电子信息产品污染控制管理办法》(也称为中国大陆RoHS),以下部份列出了本产品中可能包含的有毒有害物质或元素的名称和含量。

Table of toxic and hazardous substances/elements and their content, as required by China's management methods for controlling pollution by electronic information products.

Part Name 部件名称 Lead (Pb) 铅 Mercury (Hg) 汞 Cadmium (Cd) 镉 Hexavalent Chromium (Cr(VI)) 六价铬 Polybrominated biphenyls (PBB) 多溴联苯 Polybrominated diphenyl ethers (PBDE) 多溴二苯醚
Regulatory Model R00083 X 0 0 0 0 0

O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB / T26572 - 2011. 表示本部件所有均质材料中含有的有害物质低于GB/T26572 - 2011 的限量要求。
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB / T26572 - 2011. 表示用于本部件的至少一种均质材料中所含的危害物质超过GB/T26572 - 2011 的限制要求。

PDF preview unavailable. Download the PDF instead.

DMC-HH-ENET-05 madbuild

Related Documents

Preview DataMan 8700 Quick Reference Guide - Cognex
Quick reference guide for Cognex DataMan 8700 series barcode readers. Covers product overview, specifications, installation, accessories, and regulatory information for industrial data capture.
Preview Cognex DataMan 8700 DX Reference Manual: Setup, Operation, and Maintenance
This comprehensive reference manual details the Cognex DataMan 8700 DX barcode reader, covering its industrial applications, advanced reading technologies like 1DMax+ and PowerGrid, setup procedures, connection options (Ethernet, USB, RS-232), maintenance, and regulatory compliance. It serves as a guide for users involved in automated manufacturing and data capture.
Preview Cognex DataMan 150 Series Quick Reference Guide - Specifications, Accessories, and Usage
A comprehensive quick reference guide for the Cognex DataMan 150 Series barcode readers, covering product overview, specifications, accessories, installation, and safety precautions.
Preview DataMan Communications and Programming Guide
Comprehensive guide from Cognex detailing how to connect, configure, and program DataMan industrial barcode readers using various communication methods and software development kits.
Preview Cognex Multi-Battery Charger Quick Start Guide
A quick start guide for the Cognex Multi-Battery Charger, detailing its features, specifications, connection, charging, and mounting instructions for the DataMan 8700 reader.
Preview Cognex DataMan 80 Series Reference Manual: Industrial Barcode Reader Guide
Explore the Cognex DataMan 80 Series Reference Manual for industrial barcode reading solutions. This guide details the DataMan 80-USB and 80-PoE readers, covering setup, specifications, accessories, and maintenance for automated manufacturing applications.
Preview Cognex DataMan 370 Series Reference Manual
A comprehensive reference manual detailing the setup, configuration, accessories, specifications, and operation of the Cognex DataMan 370 series fixed-mount industrial ID readers. It covers installation, optics, lighting, maintenance, and compliance information.
Preview Cognex DataMan 380 Series Reference Manual
Comprehensive reference manual for the Cognex DataMan 380 Series of high-performance barcode readers, detailing setup, specifications, accessories, and maintenance.