Solax X1-Micro 2 in 1 Microinverter
High-efficiency and intelligent microinverters designed for flexible solar energy systems.
Product Overview
The Solax X1-Micro 2 in 1 is a series of microinverters available in 750 W, 800 W, 900 W, 1000 W, and 1200 W models. These units offer high efficiency, assured safety, intelligent design, and flexible adaptability for various solar power installations.
Key Features
- High Efficiency: Max. 1200VA output power, Max. 20A DC input current, and Two MPPT channels.
- Assured Safety: Features Rapid Shutdown function, integrated safety protection relay, and IP67 ingress protection.
- Intelligent Design: Includes reactive power control, a built-in industrial-grade WiFi module, and is designed for easy installation and maintenance.
- Flexible Adaptability: Allows for easy and flexible expansion of system capacity, supports AC coupling solutions, and enables 1-phase microinverter integration into 3-phase power grids.
Technical Specifications
Parameter | X1-Micro 750 | X1-Micro 800 | X1-Micro 900 | X1-Micro 1000 | X1-Micro 1200 |
---|---|---|---|---|---|
PV INPUT | |||||
Commonly used module power per input | 240~470+ W | 320~540+ W | 360~600+ W | 360~600+ W | 400~670+ W |
Max. PV input voltage | 60 V | ||||
MPPT voltage range | 22~60 V | ||||
Start up voltage | 22 V | ||||
Max. PV input current | 2 x 15 A | 2 x 16 A | 2 x 20 A | ||
Max. input short circuit current Isc | 2 x 20 A | 2 x 25 A | 2 x 25 A | ||
No. of MPP trackers | 2 | ||||
Strings per MPP tracker | 1 | ||||
AC OUTPUT | |||||
Rated AC output power | 750 VA | 800 VA | 900 VA | 1000 VA | 1200 VA |
Max. continuous output power | 750 VA | 800 VA | 900 VA | 1000 VA | 1200 VA |
Max. continuous output current | 3.26 A @230 V | 3.48 A @230 V | 3.92 A @230 V | 4.35 A @230 V | 5.22 A @230 V |
Rated grid voltage | 220/230/240 V | ||||
Rated AC voltage range | 180~264 V | ||||
Rated AC frequency | 50 Hz/60 Hz | ||||
AC frequency / range | 50 ± 5 Hz/60 ± 5 Hz | ||||
Max. units per 10AWG branch* | 8 @220 V 8 @230 V 8 @240 V |
7 @220 V 8 @230 V 8 @240 V |
6 @220 V 7 @230 V 7 @240 V |
5 @220 V 6 @230 V 6 @240 V |
5 @220 V 5 @230 V 5 @240 V |
Max. units per 12AWG branch* | 6 @220 V 6 @230 V 6 @240 V |
5 @220 V 6 @230 V 6 @240 V |
5 @220 V 5 @230 V 5 @240 V |
4 @220 V 5 @230 V 5 @240 V |
4 @220 V 4 @230 V 4 @240 V |
Power factor range | ~1 (0.8 leading...0.8 lagging) | ||||
THDi (rated power) | < 3% | ||||
EFFICIENCY | |||||
Max. efficiency | 96.50% | ||||
MPPT efficiency | 99.90% | ||||
Power consumption (night) | < 40 mW | ||||
STANDARD | |||||
Safety | IEC62109-1/-2, IEC63027 | ||||
EMC | IEC62920:2017, IEC61000-6-1-2-3-4, IEC61000-3-2, IEC61000-3-3, EN 301489, EN 55011 | ||||
Certifications | IEC 61727, IEC 62116, EN 50549-1:2019, ORDINANCE No. 140, ORDINANCE NO. 515, G98, VDE4105, C10/11 | ||||
ENVIRONMENT LIMIT | |||||
Ingress protection | IP67 | ||||
Operation temperature range | -40 ~ 65°C | ||||
Relative humidity | 0~100% RH (condensing) | ||||
Storage temperature | -40 ~ 65°C | ||||
GENERAL | |||||
Dimensions (W x H x D) | 260 x 212 x 40 mm | ||||
Weight | 4.1 kg | ||||
Cooling concept | Natrual cooling | ||||
Communication | Built-in WiFi | ||||
Monitoring | SolaXCloud |
*Refer to local requirements for exact number of microinverters per branch.
Communication Diagram
The microinverters can be monitored and managed through the SolaXCloud platform using two primary methods:
Method One: Direct Connection
This method involves a direct connection from the microinverter to a mobile application via WiFi.
[Mobile Phone Icon] APP <--- WiFi ---> [Microinverter Icon] Microinverter
Method Two: Router Connection
This method utilizes a router to connect the microinverter to the SolaXCloud platform, allowing for web-based monitoring and control.
[Mobile Phone Icon] APP <--- WiFi ---> [Router Icon] Router <--- Internet ---> [Web Server Icon] SolaXCloud