Solax X1-Micro 4 in 1 Microinverter
High-efficiency, intelligent, and adaptable microinverter for solar energy systems.
Key Features
High Efficiency
- Max. 2400VA output power
- Max. 19.5A DC input current
- Four MPPT channels
Assured Safety
- Rapid Shutdown function
- Safety protection relay integrated
- IP67 ingress protection
Intelligent Design
- Reactive power control
- Built-in industrial grade WiFi module
- Easy to install and maintain
Flexible Adaptability
- Easy and flexible expansion of system capacity
- Support AC coupling solution
- Support 1-phase microinverter integration into 3-phase power grid
Technical Specifications
Specification | X1-Micro 1300 | X1-Micro 1500 | X1-Micro 1600 | X1-Micro 1800 | X1-Micro 2000 | X1-Micro 2200 | X1-Micro 2400 |
---|---|---|---|---|---|---|---|
PV INPUT | |||||||
Commonly used module power per input | 300~505+ W | 320~540+ W | 360~600+ W | 400~600+ W | 400~670+ W | 450~700+ W | 500~750+ W |
Max. PV input voltage | 60 V | ||||||
MPPT voltage range | 22~60 V | ||||||
Start up voltage | 20 V | ||||||
Max. PV input current | 4 x 12 A | 4 x 14 A | 4 x 15 A | 4 x 16 A | 4 x 18 A | 4 x 19.5 A | 4 x 19.5 A |
Max. input short circuit current | 4 x 20 A | 4 x 20 A | 4 x 20 A | 4 x 25 A | 4 x 25 A | 4 x 25 A | 4 x 25 A |
No. of MPP trackers | 4 | ||||||
Strings per MPP tracker | 1 | ||||||
AC OUTPUT | |||||||
Rated AC output power | 1300 VA | 1500 VA | 1600 VA | 1800 VA | 2000 VA | 2200 VA | 2400 VA |
Max. continuous output power | 1300 VA | 1500 VA | 1600 VA | 1800 VA | 2000 VA | 2200 VA | 2400 VA |
Max. continuous output current | 5.66 A @230 V 5.42 A @240 V |
6.53 A @230 V 6.25 A @240 V |
6.96 A @230 V 6.67 A @240 V |
7.83 A @230 V 7.50 A @240 V |
8.70 A @230 V 8.34 A @240 V |
9.57 A @230 V 9.17 A @240 V |
10.43 A @230 V 10.00 A @240 V |
Rated grid voltage | 220/230/240 V | ||||||
Rated AC voltage range | 180~264 V | ||||||
Rated AC frequency | 50 Hz / 60 Hz | ||||||
AC frequency / range | 50 ± 5 Hz/60 ± 5 Hz | ||||||
Max. units per 10AWG branch* | 4@220 V 4@230 V 5@240 V |
4@220 V 4@230 V 4@240 V |
4@220 V 4@230 V 4@240 V |
3@220 V 3@230 V 3@240 V |
3@220 V 3@230 V 3@240 V |
3@220 V 3@230 V 3@240 V |
2@220 V 2@230 V 2@240 V |
Max. units per 12AWG branch* | 3@220 V 3@230 V 4@240 V |
3@220 V 3@230 V 3@240 V |
3@220 V 3@230 V 3@240 V |
2@220 V 2@230 V 3@240 V |
2@220 V 2@230 V 2@240 V |
2@220 V 2@230 V 2@240 V |
2@220 V 2@230 V 2@240 V |
Power factor range | ~ 1 (0.8 leading...0.8 lagging) | ||||||
THDi (rated power) | < 3% | ||||||
EFFICIENCY | |||||||
Max. efficiency | 96.50% | ||||||
MPPT efficiency | 99.90% | ||||||
Power consumption (night) | < 40 mW | ||||||
STANDARD | |||||||
Safety | IEC62109 | ||||||
EMC | IEC 61000, EN 62920, EN 301489, EN 55011 | ||||||
Certifications | IEC 61727, IEC 62116, EN 50549, VDE 4105, UNE217001, UNE217002, RD244/647, NTS Version 2.1 TYPE A, INMETRO, PEA/MEA | ||||||
ENVIRONMENT LIMIT | |||||||
Ingress protection | IP67 | ||||||
Operation temperature range | -40~75°C | ||||||
Relative humidity | 100% RH (condensing) | ||||||
Storage temperature | -40~75°C | ||||||
GENERAL | |||||||
Dimensions (W x H x D) | 322 x 242 x 48.5 mm | ||||||
Weight | 6.2 kg | ||||||
Cooling concept | Natural cooling | ||||||
Communication | Built-in WiFi | ||||||
Monitoring | SolaXCloud |
* Refer to local requirements for exact number of microinverters per branch.
Communication Diagram
Method One
Involves a direct connection from the microinverter to an APP via WiFi.
Method Two
Involves a connection from the microinverter to a Router, then to a Server/Phone via WiFi.