Honeywell Pressure Transducers: Product Range Guide

An industrial plant with large spherical tanks and complex piping structures is shown against a sunset sky.

Introduction

Maximize up-time. Choose the right sensor the first time. Honeywell's pressure sensors are designed to meet a wide range of test and measurement application requirements, both broad and deep, in aerospace, transportation, oil and gas, and factory automation. Rugged, yet sensitive, these sensors provide accurate and dependable readings in challenging environments. Contact Honeywell for custom solutions.

Don't let the pressure get to you. Just get to us for all your pressure sensing needs.

General Process - Pressure

Honeywell offers silicon-based (FP5000 Series) and foil-based (LM, TJE, STJE, Z) pressure sensors for automotive, aerospace, chemical, semiconductor manufacturing, and industrial automation. The FP5000 Series provides high-frequency response, high sensitivity, and overload capability.

FP5000 Series

SeriesFP5000
TypeSilicon Based
Range10 in-H₂O [0.36 psi] up to 5000 psi
Accuracy0.2 %FSS BFSL (Standard); 0.1%FSS BFSL (High)
OutputSelectable: 0-5 Vdc, 0-10 Vdc, or 4-20 mA (2-wire)
Max Line PressureVarious, based on connector*
Temperature, OperatingVarious, based on connector*
Temperature, CompensatedSelectable*
Electrical TerminationHastelloy C276 and 316L stainless steel
Wetted PartsStainless steel
Case Material* See datasheet for options

LM Series

SeriesLM
TypeFoil Based
Range1 psig to 10,000 psig
Accuracy±0.50% FS BFSL
OutputmV/V
Max Line Pressure-
Temperature, Operating-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationCable, 0.91 m [3 ft]
Wetted PartsHastelloy C276/316 stainless steel for ranges ≤ 100 psi; 17-4 PH stainless steel for ranges > 100 psi to 1,500 psi; 15-5 PH stainless steel for ranges ≥ 2,000 psi
Case MaterialStainless steel

TJE Series

SeriesTJE
TypeFoil Based
Range1 psig to 60,000 psig; 1 psia to 60,000 psia
Accuracy±0.10% FS BFSL
OutputmV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc
Max Line Pressure-100 °F to 325 °F (up to 1,000 psi); -100 °F to 250 °F (1,500 psi and above)
Temperature, Operating15 °C to 71 °C [60 °F to 160 °F]
Temperature, CompensatedPTIH-10-6P or equiv. (hermetic stainless)
Electrical Termination17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (>2,000 psi)
Wetted Parts304 Stainless steel
Case MaterialStainless steel

STJE Series

SeriesSTJE
TypeFoil Based
Range10 psig to 7,500 psig; 10 psia to 7,500 psia
Accuracy±0.05% FS BFSL
OutputmV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc
Max Line Pressure-65 °F to 250 °F
Temperature, Operating15 °C to 71 °C [60 °F to 160 °F]
Temperature, CompensatedPTIH-10-6P or equiv. (hermetic stainless)
Electrical Termination17-4 PH stainless steel (< 2,000 psi); 15-5 PH stainless steel (> 2,000 psi)
Wetted PartsStainless steel
Case Material304 Stainless steel

Z Series

SeriesZ
TypeFoil Based
Range0.5 psig to 60,000 psig; 1 psia to 60,000 psia
Accuracy±0.25% FS
OutputmV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc
Max Line Pressure-100 °F to 325 °F (up to 1,000 psi); -100 °F to 250 °F (1,500 psi and above)
Temperature, Operating15 °C to 71 °C [60 °F to 160 °F]
Temperature, CompensatedPTIH-10-6P or equiv. (hermetic stainless)
Electrical Termination17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (> 2,000 psi)
Wetted Parts304 Stainless steel
Case MaterialStainless steel

Features

Typical Applications

General Process - Differential Pressure

Honeywell offers differential pressure sensors, including silicon-based (FP2000 Differential) and foil-based (KZ Low, Z Mid, Z High, HL-Z) models for various applications.

FP2000 Differential Series

SeriesFP2000 Differential
TypeSilicon Based
Range0.5 psid to 1,000 psid (FDW, FDD)
Accuracy±0.10% BFSL; ±0.25% BFSL
MediaGases, liquids compatible with wetted parts
OutputmV/V; 0-5 Vdc; 0-10 Vdc; 4-20 mA
Max Line Pressure500 psi (FDW, FDD)
Temperature, Operating-40 °C to 116 °C [-40 °F to 240 °F]
Temperature, CompensatedFor ranges < 30 psi: 10 °C to 44 °C [50 °F to 110 °F]; For ranges ≥ 30 psi: 4 °C to 60 °C [40 °F to 140 °F]
Electrical TerminationSelectable *
Wetted PartsHA C276/316L stainless steel
Case MaterialStainless steel

KZ Low Series

SeriesKZ Low
TypeFoil Based
Range±0.5 psid to 30 psid
Accuracy±0.25% FS BFSL
MediaAll fluid and gases compatible with 316 stainless steel
Output1.0 mV/V; 1.5 mV/V; 2.0 mV/V (range dependent); 4-20 mA; 0-5 Vdc and 0-10 Vdc
Max Line Pressure1,500 psi
Temperature, Operating-1 °C to 88 °C [30 °F to 190 °F]
Temperature, Compensated-1 °C to 54 °C [30 °F to 130 °F]
Electrical TerminationBendix PTIH-10-6P or equiv.
Wetted Parts316 stainless steel
Case MaterialStainless steel

Z Mid Series

SeriesZ Mid
TypeFoil Based
Range50 psid to 750 psid
Accuracy±0.25% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc
Max Line Pressure1,500 psi
Temperature, Operating-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, Compensated15 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationPTIH-10-6P or equiv. (hermetic stainless)
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

Z High Series

SeriesZ High
TypeFoil Based
Range2,000 psid to 10,000 psid
Accuracy±0.25% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc
Max Line Pressure2,000 psi
Temperature, Operating-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, Compensated15 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationPTIH-10-6P or equiv. (hermetic stainless)
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

HL-Z Series

SeriesHL-Z
TypeFoil Based
Range50 psid to 7,500 psid
Accuracy±0.25% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc
Max Line Pressure2500 psi
Temperature, Operating-54 °C to 121 °C [-65 °F to 250 °F]
Temperature, Compensated15 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationPTIH-10-6P or equiv. (hermetic stainless)
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

Digital Output

Honeywell's Model DS digital output pressure sensors and Model DPS with CANopen® offer microprocessor-based signal conditioning. DPS with CANopen® allows for longer cable distances and simplified system wiring.

DS Series

SeriesDS
Range5 psig to 2,500 psig (AP611; AP613); 5 psia to 2,500 psia (AP612; AP614)
Accuracy0.1% typ. (TEB)
OutputDigital and Analog; RS-485 or RS-232, plus 0-5 Vdc (non-isolated). Baud rate: 1200-115200. Data framing: 1 start bit, 8 data bits, 1 stop bit. Output response: >300 readings/sec at 115k baud. Analog output: Max. 2500 updates/sec with <1 ms step response.
Temperature, Operating-40 °C to 82 °C [-40 °F to 180 °F]
Temperature, Compensated4 °C to 60 °C [40 °F to 140 °F]
Electrical TerminationBendix PT02-12-8P or equivalent mates with PT06A-12-8S
Wetted PartsHastelloy C276/316 stainless steel
Case MaterialStainless steel

DPS with CANopen® Series

SeriesDPS with CANopen®
Range10 psi to 10K psi; 1 bar to 700 bar; 70 kPa to 70,000 kPa
Accuracy< 30 psi: ±0.25%FS; >30 psi: ±0.1%FS or ±0.25%FS
OutputStandard CANopen® protocol
Temperature, Operating-25 °C to 85 °C [-13 °F to 185 °F]
Temperature, Compensated4 °C to 60 °C [40 °F to 140 °F]
Electrical TerminationBendix 6-pin; 5-pin M12 connector
Wetted PartsHastelloy C276/316L stainless steel
Case MaterialStainless steel

Features

Typical Applications

Compact/Miniature/Subminiature

Honeywell offers lightweight, subminiature pressure transducers (Series S, G) for extremely small spaces with tight clearances. They feature a compact, flush mount, low-profile design and are rugged yet thin enough to measure low pressures.

S Series

SeriesS
TypePressure
Range100 psig to 15,000 psig
Accuracy1.0% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2 mV/V
Max Line PressureN/A
Temperature, Operating-54 °C to 149 °C [-65 °F to 300 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationFour twisted leads (1.83 m [5 ft]) with external balance board
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

G Series

SeriesG
TypePressure
Range150 psig to 20,000 psig
Accuracy1.0% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2 mV/V
Max Line PressureN/A
Temperature, Operating-54 °C to 149 °C [-65 °F to 300 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationFour twisted leads (1.83 m [5 ft]) with external balance board
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

Features

Typical Applications

Flush

Honeywell's flush pressure sensors (Series A-105, A-205, 355) are designed with a miniature footprint for very small spaces. They feature a thin diaphragm and heavy sidewalls, constructed from one piece of stainless steel, making them rugged and suitable for measuring low pressures. The all-welded electrical connectors are integral to the transducer body, ideal for applications involving rough handling or corrosive fluid environments. The flush diaphragm design is also suitable for spraying or application of sealants, paints, and coatings.

A-105 Series

SeriesA-105
Range100 psi to 10,000 psi; 100 psi to 15,000 psig
Accuracy±0.50% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2 mV/V nominal; 4-20 mA @ 9-28 Vdc; 1-5 Vdc @ 16-28 Vdc; 1-10 Vdc @ 16-28 Vdc
Temperature, Operating-54 °C to 149 °C [-65 °F to 300 °F]
Temperature, Compensated-29 °C to 85 °C [-20 °F to 185 °F]
Electrical Termination16 °C to 71 °C [60 °F to 160 °F]
Wetted PartsPTIH-10-6P or equiv. (hermetic stainless)
Case Material17-4 PH stainless steel; Stainless steel

A-205 Series

SeriesA-205
Range100 psi to 10,000 psi; 100 psig to 10,000 psig
Accuracy±0.50% FS BFSL
MediaGases, liquids compatible with wetted parts
Output2 mV/V; 4-20 mA @ 9-28 Vdc; 1-5 Vdc @ 16-28 Vdc; 1-10 Vdc @ 16-28 Vdc
Temperature, Operating-54 °C to 149 °C [-65 °F to 300 °F]
Temperature, Compensated-29 °C to 149 °C [-20 °F to 300 °F]
Electrical Termination-1 °C to 71 °C [30 °F to 160 °F]
Wetted Parts16 °C to 71 °C [60 °F to 160 °F]
Case MaterialPTIH-10-6P or equivalent; Stainless steel

355 Series

Series355
Range0 psi to 500 psi to 0 psi to 5,000 psi
Accuracy±0.25% FS BFSL
MediaGases, liquids compatible with wetted parts
Output4 mA to 20 mA; 0 Vdc to 5 Vdc
Temperature, Operating-29 °C to 85 °C [-20 °F to 185 °F]
Temperature, Compensated15 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationPTIH-10-6P
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

Features

Typical Applications

High Pressure

Honeywell's high-pressure transducers (HP Series) are designed for extreme pressure ranges of 50,000 to 100,000 psi. They feature a safety blow-out plug that allows gradual pressure release if the element ruptures. These stainless steel devices operate over a wide temperature range.

HP Series

SeriesHP
Range50,000 psi to 100,000 psi
Accuracy±0.50% FS BFSL
MediaGases, liquids compatible with wetted parts
Output1 mV/V
Temperature, Operating-65 °F to 250 °F
Temperature, Compensated15 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationPTIH-10-6P or equiv. (hermetic stainless)
Wetted PartsCustom 465° stainless steel
Case Material304 stainless steel

Features

Typical Applications

Don't see what you need? Contact Honeywell for modifications or a complete custom design.

For more information, visit measurementsensors.honeywell.com or call 800-848-6564 or +1 614-850-5000.

Hazardous Location: Pressure & Diff. Pressure

Honeywell offers rugged, hermetically-sealed stainless steel sensors (811FM, 911FMD Mid, 911FMD High) for operation in hazardous locations. All-welded stainless steel diaphragms allow use with liquid, gas, or corrosive vapors.

811FM Series

Series811FM
TypePressure
Range2 psig to 10,000 psig; 2 psia to 10,000 psia
Accuracy±0.25% FS
MediaGases, liquids compatible with wetted parts
Output4 mA to 20 mA
Max Line PressureN/A
Temperature, Operating-18 °C to 82 °C [0 °F to 180 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical Termination1/2-14 NPT male with 7/8 in wrench flat. 20 GA 0.61 m [2 ft] cable with case ground
Wetted Parts17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (>2,000 psi)
Case MaterialStainless steel

911FMD Mid Series

Series911FMD Mid
TypeDifferential Pressure
Range50 psid to 750 psid
Accuracy±0.25% FS BFSL
MediaGases, liquids compatible with wetted parts
Output4 mA to 20 mA
Max Line Pressure1,500 psi
Temperature, Operating18 °C to 82 °C [0 °F to 180 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical Termination22 GA cable with case ground [2 ft], 1/2 NPT to 14 NPT
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

911FMD High Series

Series911FMD High
TypeDifferential Pressure
Range1,000 psid to 10,000 psid
Accuracy±0.25% FS BFSL
MediaLiquids compatible with wetted parts
Output4 mA to 20 mA
Max Line PressureFull scale capacity +2,000 psi max.
Temperature, Operating18 °C to 82 °C [0 °F to 180 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical Termination22 GA cable with case ground 609.6 mm [2 ft], 1/2 NPT to 14 NPT
Wetted Parts17-4 PH stainless steel
Case MaterialStainless steel

Features

Typical Applications

Oil and Gas

Honeywell's Wing Union (Hammer Union) pressure sensors (Series 434, 435, 437) are designed for demanding oil and gas applications. These all-welded, hermetically sealed, stainless steel sensors with Inconel® 718 construction and WECO® fittings withstand rigors of mud pumping, cementing, well stimulation, and coiled-tubing applications.

Series 434

Series434
Range0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar²
Accuracy¹±0.2 %FSS BFSL
Output4 mA to 20 mA, 2-wire
Temperature, Operating-40 °C to 125 °C [-40 °F to 257 °F]
Temperature, Compensated-40 °C to 85 °C [-40 °F to 185 °F]
Aperturestandard
Protective Cage Optionyes
Calibrationstandard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available
Electrical TerminationMS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin
Pressure PortWeco 2002, 2202
Wetted PartsInconel 718 (NACE compliant)

Series 435

Series435
Range0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar²
Accuracy¹±0.1 %FSS BFSL (high accuracy); ±0.2 %FSS BFSL (standard)
Output4 mA to 20 mA, 2-wire
Temperature, Operating-40 °C to 125 °C [-40 °F to 257 °F]
Temperature, Compensated-40 °C to 85 °C [-40 °F to 185 °F]
Aperturestandard
Protective Cage Optionyes
Calibrationstandard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available
Electrical TerminationMS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin
Pressure PortWeco 1502
Wetted PartsInconel 718 (NACE compliant)

Series 437

Series437
Range0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar²
Accuracy¹±0.2%FSS BFSL
Output4 mA to 20 mA, 2-wire
Temperature, Operating-40 °C to 125 °C [-40 °F to 257 °F]
Temperature, Compensated-40 °C to 85 °C [-40 °F to 185 °F]
Aperturefree flow pressure port with wide aperture
Protective Cage Optionyes
Calibrationstandard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available
Electrical TerminationMS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin
Pressure PortWeco 1502
Wetted PartsInconel 718 (NACE compliant)

Features

Typical Applications

Sanitary

Honeywell's CIP (Clean-In-Place) stainless steel sanitary process transmitters (CIP Series) are designed to meet strict environmental and cleanliness requirements for food, beverage, cosmetic, and pharmaceutical manufacturing processes. They are available with various flanges, electrical connections, and operating temperatures.

CIP Series

SeriesCIP
Range10 psig to 600 psig (CP100; CP200; CP300); 10 psia to 600 psia (CP101; CP201; CP301)
Accuracy0.1% BFSL (CP100; CP101); 0.25% BFSL (CP200; CP201); 0.5% BFSL (CP300; CP301)
Output4 mA to 20 mA, 2-wire
Temperature, Operating-1°C to +82°C (30°F to 180°F) - see datasheet
Temperature, Compensated40°F to 140°F
Electrical Termination1/2-14 NPT conduit exit with 1.5 m [5 ft] cable
Wetted PartsHA C276/316 stainless steel
Case Material316-L stainless steel

Features

Typical Applications

Liquid Level

Honeywell's liquid level sensors (LL-V Series) are designed for complete fluid submersion via vertical entry into a tank or stilling well. The all-welded stainless steel housing and pressure sensing diaphragm is resistant to most corrosive fluids. The four-conductor electrical cable includes an atmospheric vent tube for an atmospheric zero reference.

LL-V Series

SeriesLL-V
Range20 in-H₂O to 50 psig
Accuracy±0.10% BFSL
MediaLiquids compatible with stainless steel
Output0 Vdc to 5 Vdc or 4 mA to 20 mA
Temperature, Operating-18 °C to 82 °C [0 °F to 180 °F]
Temperature, Compensated16 °C to 71 °C [60 °F to 160 °F]
Electrical TerminationCable only
Wetted Parts17-4 PH stainless steel
Case MaterialAll-welded stainless steel

Features

Typical Applications

Digital Gauges - Pressure

Honeywell's stainless steel digital gauges (JH, JK Series) are portable force measurement devices for calibrating pressure and differential pressure equipment. They feature no moving parts, require little recalibration, and have excellent overpressure tolerance.

JH Series

SeriesJH
Range15,000 psi to 60,000 psig
Accuracy±0.2% FS BFSL
MediaGases, liquids compatible with wetted parts
Output4 mA to 20 mA; 0 Vdc to 5 Vdc analog outputs (optional)
Temperature, Operating-1 °C to 71 °C [30 °F to 160 °F]
Electrical TerminationCable w/ output option
Wetted Parts15-5 PH stainless steel
Case MaterialStainless steel

JK Series

SeriesJK
Range1 psig to 10,000 psig
Accuracy±0.2% FS BFSL
MediaGases, liquids compatible with wetted parts
OutputReadout
Temperature, Operating-1 °C to 71 °C [30 °F to 160 °F] (higher available)
Electrical TerminationNot required
Wetted PartsHastelloy C276/316 stainless steel for ranges up to 1,500 psi or 15-5 PH stainless steel for ranges 1,500 psi and above
Case MaterialStainless steel

Features

Typical Applications

Digital Gauges - Pressure and Differential Pressure

The JS Series digital gauge measures pressure and differential pressure.

JS Series

SeriesJS
Range1 psig to 10,000 psig
Accuracy±0.2% FS BFSL
MediaGases, liquids compatible with wetted parts
Output4 mA to 20 mA; 0 Vdc to 5 Vdc analog outputs
Temperature, Operating-1 °C to 71 °C [30 °F to 160 °F]
Electrical Termination3 ft. cable
Wetted PartsHA C276/316 stainless steel for ranges up to 1,500 psi or 15-5 PH stainless steel for ranges 1,500 psi and above
Case MaterialStainless steel

Calibration

Honeywell's Accu-Gage series (AG400, AG401) combines a pressure transducer and digital readout in one portable unit for industrial and laboratory applications. They offer cost-effective portability, enhanced accuracy, and industrial-grade durability.

Accu-Gage AG400

SeriesAccu-Gage AG400
Range15 psig/A/V to 15,000 psig/A/V
Accuracy0.05%
OutputReadout
Temperature, Operating16 °C to 41 °C [60 °F to 105 °F]
Temperature, CompensatedN/A
Electrical TerminationN/A

Accu-Gage AG401

SeriesAccu-Gage AG401
Range15 psig/A/V to 60,000 psig/A/V
Accuracy0.10%
OutputReadout
Temperature, Operating16 °C to 41 °C [60 °F to 105 °F]
Temperature, CompensatedN/A
Electrical TerminationN/A

Features

Typical Applications

Don't see what you need? Contact Honeywell for modifications or a complete custom design.

For more information, visit measurementsensors.honeywell.com or call 800-848-6564 or +1 614-850-5000.

Instruments and Amplifiers

Honeywell offers single-channel, multi-channel, and microprocessor-based units, as well as in-line amplifiers (SC500, GM, Model UV/UW, Model DV/DA) for use with transducers and transmitters. These products feature regulated power supplies and are designed for high dynamic frequency response.

SC500 Series

SeriesSC500
Display TypeVacuum/Fluorescent
Display Digits5
Input TypesStrain gage, amplified, LVDT
Input RangeStrain gage: 0.5 mV/V to 21 mV/V; Amplified: ±5 Vdc or ±10 Vdc or 4-20 mA; LVDT: 0.1-15 VRMS
Excitation VoltageStrain gage: 5 Vdc; Amplified: 12 Vdc or ±15 Vdc or 28 Vdc; LVDT: 3 Vac
Power Requirements - Voltages100 Vac to 240 Vac or 10 Vdc to 26 Vdc

GM Series

SeriesGM
Display TypeLED
Display Digits4.5
Input TypesStrain gage, amplified
Input Range1: 5 mV/V or 5 mV/V to 50 mV/V; 0: 5 Vdc or 4-20 mA
Excitation VoltageStrain gage: ±2.5 Vdc; Amplified: +5 Vdc
Power Requirements - Voltages115 Vac or 220 Vac or 12 Vdc

Model UV / UW

SeriesModel UV / UW
Input TypeStrain gage
Output Type+5 Vdc three-wire; +10 Vdc three-wire; 4-20 mA three-wire; 4-20 mA two-wire
Excitation Voltage3 Vdc or 5 Vdc @ 70 mA or 10 Vdc @ 50 mA
Power Requirements - Voltages11 Vdc to 28 Vdc
MountingNEMA 4 plastic housing or painted aluminum

Model DV / DA

SeriesModel DV / DA
Input TypeStrain gage
Output Type+5 Vdc three-wire; +10 Vdc three-wire; 4-20 mA three-wire
Excitation Voltage3 Vdc or 5 Vdc @ 30 mA or 9 Vdc @ 30 mA
Power Requirements - Voltages11 Vdc to 28 Vdc
MountingDIN rail

Features

Accessories and Instruments

Honeywell's pressure sensor accessories, connectors, displays, instruments, and amplifiers complement their test and measurement products. Many can be customized. Examples include pressure port adapters, explosion-proof enclosures, and cables. In-line amplifiers are available in various configurations.

For replacement items or further assistance, visit sensing.honeywell.com. For questions or help finding specific accessories or instruments, contact the Inside Sales team at 800-848-6564 or +1 614-850-5000, or your local distributor.

Honeywell helps relieve the pressure of making the best decision when selecting the right sensor and company for your test and measurement applications.

Warranty/Remedy

Honeywell warrants its products to be free of defective materials and faulty workmanship during the applicable warranty period. The warranty applies unless otherwise agreed in writing. If warranted goods are returned during the coverage period, Honeywell will repair or replace them at its option. This is the buyer's sole remedy and is in lieu of all other warranties. Honeywell shall not be liable for consequential, special, or indirect damages.

Honeywell may provide application assistance, but it is the buyer's sole responsibility to determine product suitability for their application. Specifications are subject to change without notice.

For more information

Honeywell Sensing and Internet of Things serves customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit sensing.honeywell.com or call:

Honeywell
Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707

PDF preview unavailable. Download the PDF instead.

sps-siot-t-m-pressure-transducer-range-guide-008888-6-en-ciid-150775 Adobe PDF Library 15.0

Related Documents

Preview Honeywell In-Wall Smart Toggle Dimmer Z-Wave Conformance Statement
This document outlines the Z-Wave protocol implementation conformance statement for the Honeywell In-Wall Smart Toggle Dimmer, model 39357/ZW3011. It details product features, Z-Wave information, technical specifications, and supported command classes.
Preview Honeywell TH8320ZW Z-Wave Thermostat Installation Guide
Comprehensive installation guide for the Honeywell TH8320ZW Z-Wave Touch-screen Thermostat, covering system types, wiring, installer setup, Z-Wave enrollment, special functions, specifications, and regulatory information.
Preview Honeywell In-Wall Smart Toggle Dimmer - Z-Wave Conformance Statement
Technical conformance statement for the Honeywell In-Wall Smart Toggle Dimmer (39357/ZW3011), detailing Z-Wave protocol features, security, and command classes.
Preview Honeywell Plug-in Outdoor Switch Z-Wave Conformance Statement
This document details the Z-Wave protocol implementation conformance statement for the Honeywell Plug-in Outdoor Switch, including product features, Z-Wave information, and supported command classes.
Preview Honeywell In-Wall Toggle Switch ZW4003: Smart Home Integration Guide
Learn how to install, configure, and integrate the Honeywell In-Wall Toggle Switch (ZW4003) into your Z-Wave smart home network. Includes quickstart, troubleshooting, and technical details.
Preview Honeywell SEMI F20 13mm Pressure Sensor for High Purity Applications
Application brief detailing the Honeywell SEMI F20 13mm pressure sensor, designed for high purity (HP) and ultra-high purity (UHP) applications in semiconductor manufacturing, biopharmaceutical production, and other controlled environments. Highlights features like corrosion resistance, stability under vacuum, and material composition.
Preview Honeywell MLH Series Heavy Duty Pressure Transducers Installation Guide
Installation instructions and technical specifications for Honeywell MLH Series Heavy Duty Pressure Transducers (6-550 bar / 50-8000 psi). Covers media compatibility, installation, electrical specs, and safety cautions.
Preview Honeywell SEMI F20 13mm Pressure Sensor Application Brief for High Purity Environments
This application brief details the Honeywell SEMI F20 13mm pressure sensor, designed for high purity (HP) and ultra-high purity (UHP) applications in semiconductor manufacturing and other demanding industries. It covers universal standards, key specifications like offset drift and material composition, and the sensor's benefits in ensuring process integrity and reducing contamination.