Introduction
Maximize up-time. Choose the right sensor the first time. Honeywell's pressure sensors are designed to meet a wide range of test and measurement application requirements, both broad and deep, in aerospace, transportation, oil and gas, and factory automation. Rugged, yet sensitive, these sensors provide accurate and dependable readings in challenging environments. Contact Honeywell for custom solutions.
Don't let the pressure get to you. Just get to us for all your pressure sensing needs.
General Process - Pressure
Honeywell offers silicon-based (FP5000 Series) and foil-based (LM, TJE, STJE, Z) pressure sensors for automotive, aerospace, chemical, semiconductor manufacturing, and industrial automation. The FP5000 Series provides high-frequency response, high sensitivity, and overload capability.
FP5000 Series
Series | FP5000 |
---|
Type | Silicon Based |
---|
Range | 10 in-H₂O [0.36 psi] up to 5000 psi |
---|
Accuracy | 0.2 %FSS BFSL (Standard); 0.1%FSS BFSL (High) |
---|
Output | Selectable: 0-5 Vdc, 0-10 Vdc, or 4-20 mA (2-wire) |
---|
Max Line Pressure | Various, based on connector* |
---|
Temperature, Operating | Various, based on connector* |
---|
Temperature, Compensated | Selectable* |
---|
Electrical Termination | Hastelloy C276 and 316L stainless steel |
---|
Wetted Parts | Stainless steel |
---|
Case Material | * See datasheet for options |
---|
LM Series
Series | LM |
---|
Type | Foil Based |
---|
Range | 1 psig to 10,000 psig |
---|
Accuracy | ±0.50% FS BFSL |
---|
Output | mV/V |
---|
Max Line Pressure | - |
---|
Temperature, Operating | -54 °C to 121 °C [-65 °F to 250 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | Cable, 0.91 m [3 ft] |
---|
Wetted Parts | Hastelloy C276/316 stainless steel for ranges ≤ 100 psi; 17-4 PH stainless steel for ranges > 100 psi to 1,500 psi; 15-5 PH stainless steel for ranges ≥ 2,000 psi |
---|
Case Material | Stainless steel |
---|
TJE Series
Series | TJE |
---|
Type | Foil Based |
---|
Range | 1 psig to 60,000 psig; 1 psia to 60,000 psia |
---|
Accuracy | ±0.10% FS BFSL |
---|
Output | mV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc |
---|
Max Line Pressure | -100 °F to 325 °F (up to 1,000 psi); -100 °F to 250 °F (1,500 psi and above) |
---|
Temperature, Operating | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Temperature, Compensated | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Electrical Termination | 17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (>2,000 psi) |
---|
Wetted Parts | 304 Stainless steel |
---|
Case Material | Stainless steel |
---|
STJE Series
Series | STJE |
---|
Type | Foil Based |
---|
Range | 10 psig to 7,500 psig; 10 psia to 7,500 psia |
---|
Accuracy | ±0.05% FS BFSL |
---|
Output | mV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc |
---|
Max Line Pressure | -65 °F to 250 °F |
---|
Temperature, Operating | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Temperature, Compensated | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Electrical Termination | 17-4 PH stainless steel (< 2,000 psi); 15-5 PH stainless steel (> 2,000 psi) |
---|
Wetted Parts | Stainless steel |
---|
Case Material | 304 Stainless steel |
---|
Z Series
Series | Z |
---|
Type | Foil Based |
---|
Range | 0.5 psig to 60,000 psig; 1 psia to 60,000 psia |
---|
Accuracy | ±0.25% FS |
---|
Output | mV/V; 4-20 mA; 0-5 Vdc; 0-10 Vdc |
---|
Max Line Pressure | -100 °F to 325 °F (up to 1,000 psi); -100 °F to 250 °F (1,500 psi and above) |
---|
Temperature, Operating | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Temperature, Compensated | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Electrical Termination | 17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (> 2,000 psi) |
---|
Wetted Parts | 304 Stainless steel |
---|
Case Material | Stainless steel |
---|
Features
- All-welded stainless steel construction
- Gage, absolute, barometric, or vacuum pressure measurements
- Differential pressures in wet/wet and wet/dry models
- Ranges from 0.5 psig/a up to 60,000 psig/a (based on model)
- Accuracies of 0.1% or 0.25% (based on model)
- Media: gases and liquids compatible with wetted parts
- Intrinsically safe options available
- Highly configurable to meet different application needs
Typical Applications
- Engine and transmission test stands
- Fluid pump pressure
- Fuel line pressure, fuel/air ratio
- Tire manufacturing mold pressure control
- Air bag system fill pressure
- Brake testing: brake assembly, brake pressure/hydraulics, pedal forces, ABS pressure
- Hydraulic and pneumatic system monitoring
- Flow measurement
- Depth sensing, liquid level
- Pressure equalization
- Leak detection
General Process - Differential Pressure
Honeywell offers differential pressure sensors, including silicon-based (FP2000 Differential) and foil-based (KZ Low, Z Mid, Z High, HL-Z) models for various applications.
FP2000 Differential Series
Series | FP2000 Differential |
---|
Type | Silicon Based |
---|
Range | 0.5 psid to 1,000 psid (FDW, FDD) |
---|
Accuracy | ±0.10% BFSL; ±0.25% BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | mV/V; 0-5 Vdc; 0-10 Vdc; 4-20 mA |
---|
Max Line Pressure | 500 psi (FDW, FDD) |
---|
Temperature, Operating | -40 °C to 116 °C [-40 °F to 240 °F] |
---|
Temperature, Compensated | For ranges < 30 psi: 10 °C to 44 °C [50 °F to 110 °F]; For ranges ≥ 30 psi: 4 °C to 60 °C [40 °F to 140 °F] |
---|
Electrical Termination | Selectable * |
---|
Wetted Parts | HA C276/316L stainless steel |
---|
Case Material | Stainless steel |
---|
KZ Low Series
Series | KZ Low |
---|
Type | Foil Based |
---|
Range | ±0.5 psid to 30 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | All fluid and gases compatible with 316 stainless steel |
---|
Output | 1.0 mV/V; 1.5 mV/V; 2.0 mV/V (range dependent); 4-20 mA; 0-5 Vdc and 0-10 Vdc |
---|
Max Line Pressure | 1,500 psi |
---|
Temperature, Operating | -1 °C to 88 °C [30 °F to 190 °F] |
---|
Temperature, Compensated | -1 °C to 54 °C [30 °F to 130 °F] |
---|
Electrical Termination | Bendix PTIH-10-6P or equiv. |
---|
Wetted Parts | 316 stainless steel |
---|
Case Material | Stainless steel |
---|
Z Mid Series
Series | Z Mid |
---|
Type | Foil Based |
---|
Range | 50 psid to 750 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc |
---|
Max Line Pressure | 1,500 psi |
---|
Temperature, Operating | -54 °C to 121 °C [-65 °F to 250 °F] |
---|
Temperature, Compensated | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
Z High Series
Series | Z High |
---|
Type | Foil Based |
---|
Range | 2,000 psid to 10,000 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc |
---|
Max Line Pressure | 2,000 psi |
---|
Temperature, Operating | -54 °C to 121 °C [-65 °F to 250 °F] |
---|
Temperature, Compensated | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
HL-Z Series
Series | HL-Z |
---|
Type | Foil Based |
---|
Range | 50 psid to 7,500 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2.0 mV/V nominal; 4-20 mA; 0-5 Vdc and 0-10 Vdc |
---|
Max Line Pressure | 2500 psi |
---|
Temperature, Operating | -54 °C to 121 °C [-65 °F to 250 °F] |
---|
Temperature, Compensated | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
Digital Output
Honeywell's Model DS digital output pressure sensors and Model DPS with CANopen® offer microprocessor-based signal conditioning. DPS with CANopen® allows for longer cable distances and simplified system wiring.
DS Series
Series | DS |
---|
Range | 5 psig to 2,500 psig (AP611; AP613); 5 psia to 2,500 psia (AP612; AP614) |
---|
Accuracy | 0.1% typ. (TEB) |
---|
Output | Digital and Analog; RS-485 or RS-232, plus 0-5 Vdc (non-isolated). Baud rate: 1200-115200. Data framing: 1 start bit, 8 data bits, 1 stop bit. Output response: >300 readings/sec at 115k baud. Analog output: Max. 2500 updates/sec with <1 ms step response. |
---|
Temperature, Operating | -40 °C to 82 °C [-40 °F to 180 °F] |
---|
Temperature, Compensated | 4 °C to 60 °C [40 °F to 140 °F] |
---|
Electrical Termination | Bendix PT02-12-8P or equivalent mates with PT06A-12-8S |
---|
Wetted Parts | Hastelloy C276/316 stainless steel |
---|
Case Material | Stainless steel |
---|
DPS with CANopen® Series
Series | DPS with CANopen® |
---|
Range | 10 psi to 10K psi; 1 bar to 700 bar; 70 kPa to 70,000 kPa |
---|
Accuracy | < 30 psi: ±0.25%FS; >30 psi: ±0.1%FS or ±0.25%FS |
---|
Output | Standard CANopen® protocol |
---|
Temperature, Operating | -25 °C to 85 °C [-13 °F to 185 °F] |
---|
Temperature, Compensated | 4 °C to 60 °C [40 °F to 140 °F] |
---|
Electrical Termination | Bendix 6-pin; 5-pin M12 connector |
---|
Wetted Parts | Hastelloy C276/316L stainless steel |
---|
Case Material | Stainless steel |
---|
Features
- 0.1% total error band (includes temperature)
- 1200 Hz analog response (Model DS)
- CANbus with CANopen® protocol (Model DPS)
- All-welded stainless steel construction
- Selectable RS-232 or RS-485 (Model DS)
- 380 readings/second digital output (Model DS)
- Media: gas and liquid compatible with 316L SS and Hastelloy® C276
Typical Applications
- Automotive performance analysis
- Aerospace monitoring and test/research labs
- Agriculture and construction equipment
- Rail equipment testing
- Train communication networks
- General industrial process control
- Injection/blow molding machines
- Packaging machines
- HVAC testing
- Semiconductor manufacturing
- Blood dialysis equipment
- Medical equipment systems
Compact/Miniature/Subminiature
Honeywell offers lightweight, subminiature pressure transducers (Series S, G) for extremely small spaces with tight clearances. They feature a compact, flush mount, low-profile design and are rugged yet thin enough to measure low pressures.
S Series
Series | S |
---|
Type | Pressure |
---|
Range | 100 psig to 15,000 psig |
---|
Accuracy | 1.0% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2 mV/V |
---|
Max Line Pressure | N/A |
---|
Temperature, Operating | -54 °C to 149 °C [-65 °F to 300 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | Four twisted leads (1.83 m [5 ft]) with external balance board |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
G Series
Series | G |
---|
Type | Pressure |
---|
Range | 150 psig to 20,000 psig |
---|
Accuracy | 1.0% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2 mV/V |
---|
Max Line Pressure | N/A |
---|
Temperature, Operating | -54 °C to 149 °C [-65 °F to 300 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | Four twisted leads (1.83 m [5 ft]) with external balance board |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
Features
- Subminiature size fits in extremely small spaces
- Lightweight, one-piece stainless steel construction with thin diaphragm for rugged performance and low pressure measurements
- Pressure measurement ranges: 100 psig to 20,000 psig with 1.0% accuracy
- High frequency
- Media: gases and liquids compatible with wetted parts
Typical Applications
- Engine and transmission test stands
- Brake assembly test
- Tire manufacturing mold pressure control
- Air bag system fill pressure
- Pressure brake testing, hydraulic sensor: brake pedal forces, ABS pressures
- Well stimulation
- Measurement While Drilling (MWD)
- Fluid dispensing
- Fluid pump pressure
Flush
Honeywell's flush pressure sensors (Series A-105, A-205, 355) are designed with a miniature footprint for very small spaces. They feature a thin diaphragm and heavy sidewalls, constructed from one piece of stainless steel, making them rugged and suitable for measuring low pressures. The all-welded electrical connectors are integral to the transducer body, ideal for applications involving rough handling or corrosive fluid environments. The flush diaphragm design is also suitable for spraying or application of sealants, paints, and coatings.
A-105 Series
Series | A-105 |
---|
Range | 100 psi to 10,000 psi; 100 psi to 15,000 psig |
---|
Accuracy | ±0.50% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2 mV/V nominal; 4-20 mA @ 9-28 Vdc; 1-5 Vdc @ 16-28 Vdc; 1-10 Vdc @ 16-28 Vdc |
---|
Temperature, Operating | -54 °C to 149 °C [-65 °F to 300 °F] |
---|
Temperature, Compensated | -29 °C to 85 °C [-20 °F to 185 °F] |
---|
Electrical Termination | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Wetted Parts | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Case Material | 17-4 PH stainless steel; Stainless steel |
---|
A-205 Series
Series | A-205 |
---|
Range | 100 psi to 10,000 psi; 100 psig to 10,000 psig |
---|
Accuracy | ±0.50% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 2 mV/V; 4-20 mA @ 9-28 Vdc; 1-5 Vdc @ 16-28 Vdc; 1-10 Vdc @ 16-28 Vdc |
---|
Temperature, Operating | -54 °C to 149 °C [-65 °F to 300 °F] |
---|
Temperature, Compensated | -29 °C to 149 °C [-20 °F to 300 °F] |
---|
Electrical Termination | -1 °C to 71 °C [30 °F to 160 °F] |
---|
Wetted Parts | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Case Material | PTIH-10-6P or equivalent; Stainless steel |
---|
355 Series
Series | 355 |
---|
Range | 0 psi to 500 psi to 0 psi to 5,000 psi |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA; 0 Vdc to 5 Vdc |
---|
Temperature, Operating | -29 °C to 85 °C [-20 °F to 185 °F] |
---|
Temperature, Compensated | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | PTIH-10-6P |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
Features
- Miniature size to fit in very small spaces
- One piece stainless steel fully welded construction with thin flush diaphragm for rugged performance and low pressure measurements
- Pressure measurement ranges: 100 psig up to 15,000 psig with up to ±0.50% accuracy; 0 psig up to 5,000 psig with up to ±0.25% accuracy
- No dead volume
- Can be used in corrosive fluid environments
- Media: gases and liquids compatible with wetted parts
- Intrinsically safe options available
Typical Applications
- Engine and transmission test stands
- Fluid pump pressure
- Fuel line pressure and fuel/air ratio
- Brake assembly test
- Tire manufacturing mold pressure control
- Air bag system fill pressure
- Pressure brake testing, hydraulic sensor: brake pedal forces, ABS pressures
- Spraying or application of sealants, paints, coatings, or other congealable media
High Pressure
Honeywell's high-pressure transducers (HP Series) are designed for extreme pressure ranges of 50,000 to 100,000 psi. They feature a safety blow-out plug that allows gradual pressure release if the element ruptures. These stainless steel devices operate over a wide temperature range.
HP Series
Series | HP |
---|
Range | 50,000 psi to 100,000 psi |
---|
Accuracy | ±0.50% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 1 mV/V |
---|
Temperature, Operating | -65 °F to 250 °F |
---|
Temperature, Compensated | 15 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | PTIH-10-6P or equiv. (hermetic stainless) |
---|
Wetted Parts | Custom 465° stainless steel |
---|
Case Material | 304 stainless steel |
---|
Features
- Stainless steel construction
- Extreme pressure ranges from 50,000 psi to 100,000 psi
- 0.5% accuracy
- mV/V, 4-20 mA, 0-5 Vdc, or 0-10 Vdc output
- Media: gases and liquids compatible with wetted parts
- Intrinsically safe option available
- CE approved
Typical Applications
- Well fracturing oil and gas
- Isostatic press monitoring
- Rock mechanics
- Aseptic food processing
Don't see what you need? Contact Honeywell for modifications or a complete custom design.
For more information, visit measurementsensors.honeywell.com or call 800-848-6564 or +1 614-850-5000.
Hazardous Location: Pressure & Diff. Pressure
Honeywell offers rugged, hermetically-sealed stainless steel sensors (811FM, 911FMD Mid, 911FMD High) for operation in hazardous locations. All-welded stainless steel diaphragms allow use with liquid, gas, or corrosive vapors.
811FM Series
Series | 811FM |
---|
Type | Pressure |
---|
Range | 2 psig to 10,000 psig; 2 psia to 10,000 psia |
---|
Accuracy | ±0.25% FS |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA |
---|
Max Line Pressure | N/A |
---|
Temperature, Operating | -18 °C to 82 °C [0 °F to 180 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | 1/2-14 NPT male with 7/8 in wrench flat. 20 GA 0.61 m [2 ft] cable with case ground |
---|
Wetted Parts | 17-4 PH stainless steel (<2,000 psi); 15-5 PH stainless steel (>2,000 psi) |
---|
Case Material | Stainless steel |
---|
911FMD Mid Series
Series | 911FMD Mid |
---|
Type | Differential Pressure |
---|
Range | 50 psid to 750 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA |
---|
Max Line Pressure | 1,500 psi |
---|
Temperature, Operating | 18 °C to 82 °C [0 °F to 180 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | 22 GA cable with case ground [2 ft], 1/2 NPT to 14 NPT |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
911FMD High Series
Series | 911FMD High |
---|
Type | Differential Pressure |
---|
Range | 1,000 psid to 10,000 psid |
---|
Accuracy | ±0.25% FS BFSL |
---|
Media | Liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA |
---|
Max Line Pressure | Full scale capacity +2,000 psi max. |
---|
Temperature, Operating | 18 °C to 82 °C [0 °F to 180 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | 22 GA cable with case ground 609.6 mm [2 ft], 1/2 NPT to 14 NPT |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | Stainless steel |
---|
Features
- Rugged stainless steel construction
- All welded stainless steel diaphragms
- True gage or absolute design
- Differential pressure (wet/wet) with low, mid, and high ranges
- Media: gases and liquids compatible with wetted parts
- Intrinsically safe option available
Typical Applications
- Bulk liquid inventory control
- Steam management
- Power plant/power generation
- Oil and gas exploration, refining, process monitoring
- Chemical process control
- Flow measurement
- Depth sensing
- Pressure equalization
- Liquid level and leak detection
Oil and Gas
Honeywell's Wing Union (Hammer Union) pressure sensors (Series 434, 435, 437) are designed for demanding oil and gas applications. These all-welded, hermetically sealed, stainless steel sensors with Inconel® 718 construction and WECO® fittings withstand rigors of mud pumping, cementing, well stimulation, and coiled-tubing applications.
Series 434
Series | 434 |
---|
Range | 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar² |
---|
Accuracy¹ | ±0.2 %FSS BFSL |
---|
Output | 4 mA to 20 mA, 2-wire |
---|
Temperature, Operating | -40 °C to 125 °C [-40 °F to 257 °F] |
---|
Temperature, Compensated | -40 °C to 85 °C [-40 °F to 185 °F] |
---|
Aperture | standard |
---|
Protective Cage Option | yes |
---|
Calibration | standard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available |
---|
Electrical Termination | MS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin |
---|
Pressure Port | Weco 2002, 2202 |
---|
Wetted Parts | Inconel 718 (NACE compliant) |
---|
Series 435
Series | 435 |
---|
Range | 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar² |
---|
Accuracy¹ | ±0.1 %FSS BFSL (high accuracy); ±0.2 %FSS BFSL (standard) |
---|
Output | 4 mA to 20 mA, 2-wire |
---|
Temperature, Operating | -40 °C to 125 °C [-40 °F to 257 °F] |
---|
Temperature, Compensated | -40 °C to 85 °C [-40 °F to 185 °F] |
---|
Aperture | standard |
---|
Protective Cage Option | yes |
---|
Calibration | standard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available |
---|
Electrical Termination | MS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin |
---|
Pressure Port | Weco 1502 |
---|
Wetted Parts | Inconel 718 (NACE compliant) |
---|
Series 437
Series | 437 |
---|
Range | 0 psi to 5000 psi; 0 psi to 6000 psi; 0 psi to 10000 psi; 0 psi to 15000 psi; 0 psi to 20000 psi²; 0 bar to 350 bar; 0 bar to 400 bar; 0 bar to 700 bar; 0 bar to 1000 bar; 0 bar to 1350 bar² |
---|
Accuracy¹ | ±0.2%FSS BFSL |
---|
Output | 4 mA to 20 mA, 2-wire |
---|
Temperature, Operating | -40 °C to 125 °C [-40 °F to 257 °F] |
---|
Temperature, Compensated | -40 °C to 85 °C [-40 °F to 185 °F] |
---|
Aperture | free flow pressure port with wide aperture |
---|
Protective Cage Option | yes |
---|
Calibration | standard five-point calibration: 0%, 50%, 100% of full scale; special 10-point and 20-point calibration options available |
---|
Electrical Termination | MS Series compatible 4-pin; Bendix PT, 6-pin; Jupiter M and TP Series (4-pin); Jupiter M and TP Series (7-pin); Rota B-Series 4-pin |
---|
Pressure Port | Weco 1502 |
---|
Wetted Parts | Inconel 718 (NACE compliant) |
---|
Features
- Rugged stainless steel and 718 Inconel construction
- Hermetically sealed for use in liquid or wet environments
- 0.2% accuracy or 0.1% high accuracy (435 only)
- Pressure ranges up to 20,000 psig
- Corrosive and abrasive service compatible with wetted parts
- Intrinsically safe option available
Typical Applications
- Oil and gas drilling
- Mud pumps/mud logging
- Measurement while drilling (MWD)
- Fracturing and cementing
- Acidizing
- Well head measurement
- Standpipe
- Stimulation
Sanitary
Honeywell's CIP (Clean-In-Place) stainless steel sanitary process transmitters (CIP Series) are designed to meet strict environmental and cleanliness requirements for food, beverage, cosmetic, and pharmaceutical manufacturing processes. They are available with various flanges, electrical connections, and operating temperatures.
CIP Series
Series | CIP |
---|
Range | 10 psig to 600 psig (CP100; CP200; CP300); 10 psia to 600 psia (CP101; CP201; CP301) |
---|
Accuracy | 0.1% BFSL (CP100; CP101); 0.25% BFSL (CP200; CP201); 0.5% BFSL (CP300; CP301) |
---|
Output | 4 mA to 20 mA, 2-wire |
---|
Temperature, Operating | -1°C to +82°C (30°F to 180°F) - see datasheet |
---|
Temperature, Compensated | 40°F to 140°F |
---|
Electrical Termination | 1/2-14 NPT conduit exit with 1.5 m [5 ft] cable |
---|
Wetted Parts | HA C276/316 stainless steel |
---|
Case Material | 316-L stainless steel |
---|
Features
- Designed for use in food, beverage, pharmaceutical, and other clean manufacturing processes
- Stainless steel construction
- Pressure ranges: 10 psig/a to 600 psig/a
- Accuracy to 0.1%
- Track temperature changes, 93 °C per minute [200 °F per minute]
- 500 s pressure response time
- Secondary containment exceeds 1,500 psi
- 4 mA to 20 mA output
- Media: steam, ethylene oxide, liquid, gas
- Intrinsically safe option available
- CE approved
Typical Applications
- Food Processing
- Pharmaceuticals
- Dairy and cheese
- Chemical manufacturing
- Beverage processing
- Biological systems
- Paint and ink
- Cosmetics, perfumes
- Clean-in-place systems
- Clean Gas systems
- Sanitizers and cleaning systems
- Microprocessor
- Pulp and paper
Liquid Level
Honeywell's liquid level sensors (LL-V Series) are designed for complete fluid submersion via vertical entry into a tank or stilling well. The all-welded stainless steel housing and pressure sensing diaphragm is resistant to most corrosive fluids. The four-conductor electrical cable includes an atmospheric vent tube for an atmospheric zero reference.
LL-V Series
Series | LL-V |
---|
Range | 20 in-H₂O to 50 psig |
---|
Accuracy | ±0.10% BFSL |
---|
Media | Liquids compatible with stainless steel |
---|
Output | 0 Vdc to 5 Vdc or 4 mA to 20 mA |
---|
Temperature, Operating | -18 °C to 82 °C [0 °F to 180 °F] |
---|
Temperature, Compensated | 16 °C to 71 °C [60 °F to 160 °F] |
---|
Electrical Termination | Cable only |
---|
Wetted Parts | 17-4 PH stainless steel |
---|
Case Material | All-welded stainless steel |
---|
Features
- Submersible
- True gage design
- All welded stainless steel construction
- Conduit connection
- 0.1% accuracy
- Media: liquids compatible with stainless steel
Typical Applications
- Well detection
- Sewer and drainage monitoring
- Vertical-entry fluid tanks
Digital Gauges - Pressure
Honeywell's stainless steel digital gauges (JH, JK Series) are portable force measurement devices for calibrating pressure and differential pressure equipment. They feature no moving parts, require little recalibration, and have excellent overpressure tolerance.
JH Series
Series | JH |
---|
Range | 15,000 psi to 60,000 psig |
---|
Accuracy | ±0.2% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA; 0 Vdc to 5 Vdc analog outputs (optional) |
---|
Temperature, Operating | -1 °C to 71 °C [30 °F to 160 °F] |
---|
Electrical Termination | Cable w/ output option |
---|
Wetted Parts | 15-5 PH stainless steel |
---|
Case Material | Stainless steel |
---|
JK Series
Series | JK |
---|
Range | 1 psig to 10,000 psig |
---|
Accuracy | ±0.2% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | Readout |
---|
Temperature, Operating | -1 °C to 71 °C [30 °F to 160 °F] (higher available) |
---|
Electrical Termination | Not required |
---|
Wetted Parts | Hastelloy C276/316 stainless steel for ranges up to 1,500 psi or 15-5 PH stainless steel for ranges 1,500 psi and above |
---|
Case Material | Stainless steel |
---|
Features
- Rugged, stainless steel construction
- Gage, absolute, vacuum or compound measurements
- Field selectable units of measure
- Easy to read digital display with large buttons
- Quick and easy setup and operation
- Storage of calibration data and setup on internal memory chip
- Hi/lo capture and store
- Media: gases and liquids compatible with wetted parts
- Select models available which meet industry standards as required: NEMA 4, NIST traceability, etc.
Typical Applications
- Calibration
- Industrial quality or statistical control
- Laboratory applications
Digital Gauges - Pressure and Differential Pressure
The JS Series digital gauge measures pressure and differential pressure.
JS Series
Series | JS |
---|
Range | 1 psig to 10,000 psig |
---|
Accuracy | ±0.2% FS BFSL |
---|
Media | Gases, liquids compatible with wetted parts |
---|
Output | 4 mA to 20 mA; 0 Vdc to 5 Vdc analog outputs |
---|
Temperature, Operating | -1 °C to 71 °C [30 °F to 160 °F] |
---|
Electrical Termination | 3 ft. cable |
---|
Wetted Parts | HA C276/316 stainless steel for ranges up to 1,500 psi or 15-5 PH stainless steel for ranges 1,500 psi and above |
---|
Case Material | Stainless steel |
---|
Calibration
Honeywell's Accu-Gage series (AG400, AG401) combines a pressure transducer and digital readout in one portable unit for industrial and laboratory applications. They offer cost-effective portability, enhanced accuracy, and industrial-grade durability.
Accu-Gage AG400
Series | Accu-Gage AG400 |
---|
Range | 15 psig/A/V to 15,000 psig/A/V |
---|
Accuracy | 0.05% |
---|
Output | Readout |
---|
Temperature, Operating | 16 °C to 41 °C [60 °F to 105 °F] |
---|
Temperature, Compensated | N/A |
---|
Electrical Termination | N/A |
---|
Accu-Gage AG401
Series | Accu-Gage AG401 |
---|
Range | 15 psig/A/V to 60,000 psig/A/V |
---|
Accuracy | 0.10% |
---|
Output | Readout |
---|
Temperature, Operating | 16 °C to 41 °C [60 °F to 105 °F] |
---|
Temperature, Compensated | N/A |
---|
Electrical Termination | N/A |
---|
Features
- Combination pressure transducer and digital readout in one portable, rugged display
- Choose either single or double-line displays
- Enhanced accuracy of 0.05% (AG-400) or 0.10% (AG-401) full scale
- Often used as replacements for precision dial gauges, mercury columns, or quartz tube barometers
- Media: gases and liquids compatible with wetted parts
- NIST traceable instrument and transducer
- CE approved
Typical Applications
- Calibration
- Industrial quality or statistical control
- Laboratory applications
Don't see what you need? Contact Honeywell for modifications or a complete custom design.
For more information, visit measurementsensors.honeywell.com or call 800-848-6564 or +1 614-850-5000.
Instruments and Amplifiers
Honeywell offers single-channel, multi-channel, and microprocessor-based units, as well as in-line amplifiers (SC500, GM, Model UV/UW, Model DV/DA) for use with transducers and transmitters. These products feature regulated power supplies and are designed for high dynamic frequency response.
SC500 Series
Series | SC500 |
---|
Display Type | Vacuum/Fluorescent |
---|
Display Digits | 5 |
---|
Input Types | Strain gage, amplified, LVDT |
---|
Input Range | Strain gage: 0.5 mV/V to 21 mV/V; Amplified: ±5 Vdc or ±10 Vdc or 4-20 mA; LVDT: 0.1-15 VRMS |
---|
Excitation Voltage | Strain gage: 5 Vdc; Amplified: 12 Vdc or ±15 Vdc or 28 Vdc; LVDT: 3 Vac |
---|
Power Requirements - Voltages | 100 Vac to 240 Vac or 10 Vdc to 26 Vdc |
---|
GM Series
Series | GM |
---|
Display Type | LED |
---|
Display Digits | 4.5 |
---|
Input Types | Strain gage, amplified |
---|
Input Range | 1: 5 mV/V or 5 mV/V to 50 mV/V; 0: 5 Vdc or 4-20 mA |
---|
Excitation Voltage | Strain gage: ±2.5 Vdc; Amplified: +5 Vdc |
---|
Power Requirements - Voltages | 115 Vac or 220 Vac or 12 Vdc |
---|
Model UV / UW
Series | Model UV / UW |
---|
Input Type | Strain gage |
---|
Output Type | +5 Vdc three-wire; +10 Vdc three-wire; 4-20 mA three-wire; 4-20 mA two-wire |
---|
Excitation Voltage | 3 Vdc or 5 Vdc @ 70 mA or 10 Vdc @ 50 mA |
---|
Power Requirements - Voltages | 11 Vdc to 28 Vdc |
---|
Mounting | NEMA 4 plastic housing or painted aluminum |
---|
Model DV / DA
Series | Model DV / DA |
---|
Input Type | Strain gage |
---|
Output Type | +5 Vdc three-wire; +10 Vdc three-wire; 4-20 mA three-wire |
---|
Excitation Voltage | 3 Vdc or 5 Vdc @ 30 mA or 9 Vdc @ 30 mA |
---|
Power Requirements - Voltages | 11 Vdc to 28 Vdc |
---|
Mounting | DIN rail |
---|
Features
- Single and multi-channel units – portables and handhelds
- Digital pressure gage
- In-line amplifiers
- Power supplies
- Transducer simulation
- Analog and micro-processor base
Accessories and Instruments
Honeywell's pressure sensor accessories, connectors, displays, instruments, and amplifiers complement their test and measurement products. Many can be customized. Examples include pressure port adapters, explosion-proof enclosures, and cables. In-line amplifiers are available in various configurations.
For replacement items or further assistance, visit sensing.honeywell.com. For questions or help finding specific accessories or instruments, contact the Inside Sales team at 800-848-6564 or +1 614-850-5000, or your local distributor.
Honeywell helps relieve the pressure of making the best decision when selecting the right sensor and company for your test and measurement applications.
Warranty/Remedy
Honeywell warrants its products to be free of defective materials and faulty workmanship during the applicable warranty period. The warranty applies unless otherwise agreed in writing. If warranted goods are returned during the coverage period, Honeywell will repair or replace them at its option. This is the buyer's sole remedy and is in lieu of all other warranties. Honeywell shall not be liable for consequential, special, or indirect damages.
Honeywell may provide application assistance, but it is the buyer's sole responsibility to determine product suitability for their application. Specifications are subject to change without notice.
For more information
Honeywell Sensing and Internet of Things serves customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing, or the nearest Authorized Distributor, visit sensing.honeywell.com or call:
- International: +815 618 3231
- USA/Canada: +302 327 8920
Honeywell
Sensing and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707