Secop Single Pack KLF6.6CNH 115-127V 60Hz CSIR

Brand: Secop

Single Pack Information

Single Pack Code Number: 195B4695

Position Title Code Amount
1 Compressor KLF6.6CNH 106H3700 1
2 KL accessories 103N1060 1
3 Starting capacitor (240µF 125V, 6.3mm) 117U5002 1
4 Starting relay (QLZ-11.6A, overload protector T1141/L6) 117U7076 1
5 Bolt joint for one compressor | M6 | ø16mm 118-1917 1

Compressor Technical Data: KLF6.6CNH

Model Designation: KLF6.6CNH

Sales Code: 106H3700

Voltage/Frequency: 115-127V / 60Hz 1~

Compressor Design

Parameter Value
Oil typePolyolester
Oil viscosity10,4 cSt
Oil quantity170 cm³ / 5.7 fl.oz
Refrigerant charge - tech. limit200g / 7.1oz
Free gas volume comp.1580 cm³ / 53.4 fl.oz
Weight9.5 kg / 20.9 lbs
Motor protectionExternal
Winding resistance main2 Ω (at 25°C)
Winding resistance aux5.3 Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.130°C / 266°F
Refrigerant(s)R290
Displacement6.6 cm³ / 0.4 cu.in
Compressors on pallet100

Image: Secop KL-Series compressor.

General Configurations

Parameter Conf. 1 (CSIR) Conf. 2 (RSCR)
MotorconfigurationCSIRRSCR
Power supply (nominal)115-127V/60Hz115-127V/60Hz
Number of phases11
Voltage range95-140V95-140V
ApprovalsUL, CCCUL, CCC
Starting torqueHSTLST
Note-/--/-

Applications

Parameter Conf. 1 Conf. 2
RefrigerantR290R290
ApplicationLBP+MBPLBP+MBP
System coolingfan 3m/sfan 3m/s
Hot gas defrostOKOK
Long interval pull downOKOK

Electrical Data

Parameter Conf. 1 Conf. 2
Starting device typerelayPTC
Run capacitor-/-15µF
Start capacitor240µF-/-
LRA (locked rotor amps / 4s/ U(N))31.1A31.1A
RLA (rated load amps / 1s/ U(N))4.3A4.3A
Cut in current (U(N))27.8A31.5A

Compressor Dimensions and Fixation

Dimensions

Housing

DimensionValue (mm)Value (in)
A Height1827.17
B Height1756.89
C Length shell1987.8
D Length w. cover2389.37
E Width1606.3

Diagram: Shows external dimensions of the compressor housing with labels A, B, C, D, E, and Z. Also shows vertical and horizontal angles.

Connectors

Parameter Diameter Material Angle Position l/h/w Straight tube l.
Suction (X) Discharge (Y) Process (Z) Horizontal Vertical mmin mmin
[mm] øi 8.11-8.29øi 6.41-6.59øi 6.41-6.59 copper +2° 35° 119/73/59 4.7/2.9/2.3 14 0.5
[in] øi 0.32-0.33øi 0.25-0.26øi 0.25-0.26
Horizontal angle +2°35°
Vertical angle +2°30°
Position l/h/w [mm] 119/73/59 117/107/66-88/101/71
Position l/h/w [in] 4.7/2.9/2.3 4.6/4.2/2.6-3.5/4/2.8
Straight tube l. [mm] 14 1414
Straight tube l. [in] 0.5 0.50.5

Diagram: Shows connector dimensions and angles for suction, discharge, and process ports.

Compressor Fixation

Component Baseplate Large holes Small holes
[mm][inch][mm][inch][mm][inch]
Bl2048.03
Bw1325.2
ØE9.70.38
ØL1656.5101.64
LwØ 19Ø 0.75
Sl1706.7
Sw702.76
LlØ 16Ø 0.63

Diagram: Illustrates compressor baseplate dimensions, large holes (ØL, Lw), and small holes (Sl, Sw, ØS) for mounting. Also shows a detailed view of a bolt joint with washer, nut, sleeve, compressor base, cabinet base, and rubber grommet. A separate diagram shows a snap-on mechanism with washer, clip, steel pin, compressor base, cabinet base, and rubber grommet.

Mounting Accessories

Accessory One Comp. Multi Pack
Bolt joint | M6 | ø16mm118-1917118-1918
Bolt joint | ø1/4" | ø16mm118-1946
Bolt joint | ø1/4" | ø19mm118-1949
Snap-on | ø7.3 | ø16mm118-1947118-1919

Application Notes: Provision for PE Grounding is located at the PE Stamp on the compressor.

Configuration 1: CSIR

Model Designation: KLF6.6CNH

Voltage/Frequency: 115-127V/60Hz

Sales Code: 106H3700

Configuration Details

ParameterValue
MotorconfigurationCSIR
Power supply (nominal)115-127V/60Hz 1~
RefrigerantR290
ApplicationLBP+MBP
Voltage range95-140V
Starting torqueHST
ApprovalsUL, CCC

Electrical Accessories / Wiring Diagram

Diagram: Shows electrical accessories and wiring for the CSIR configuration, including components labeled a5, c, b, and d.

Ambient/Machine Room Temperatures

ParameterRange
Ambient temperature range10 - 43°C / 50 - 110°F
Machine room temperature range10 - 48°C / 50 - 119°F
Compressor coolingfan 3m/s

Operation Pressure Range

Graph: Shows condensing pressure (sat. temp.) vs. evaporation pressure (sat. temp.) for Configuration 1. It indicates zones for continuous operation and transitory operation.

Graph: Shows condensing pressure [bara] vs. evaporation pressure [bara] for Configuration 1, indicating zones for continuous operation and transitory operation.

Components

Component IDDescriptionCode
a5Current relay (T1141/L6-S6)117U7076
cStart capacitor (240µF)117U5002
b, dCover + clamp + screws (5VA-compl.)103N0600

Alternative Components

DescriptionCode
100x cover + clamp + screws (5VA)103N2060
Cover + clamp + screws (5VA) in bag103N1060

Optimization + Standard Conditions & Performance Tables (Conf. 1)

Conditions: R290, 115V/60Hz, CSIR, fan 3m/s, UL, CCC

Optimization + Standard Conditions

Conditions Cooling Capacity Power Consumption P1 [W] Current [A] Ref. mass flow [kg/h]
pe [°C]pc [°C]RGT Tliq [°C][W][Btu/h][kcal/h]COP [W/W]EER [Btu/Wh][kcal/Wh]
ASHRAE LBP -235432396.91355341.61.615.511.39 246.03.184.02
cecomaf LBP -255532297.21015255.81.264.301.08 236.13.133.70
EN12900 LBP -354020224.4766193.11.204.111.04 186.52.892.56
ASHRAE MBP -75435717.62451617.62.087.091.79 345.83.848.19
cecomaf MBP -105532567.91940488.81.735.901.49 328.53.727.18
EN12900 MBP -104520639.32183550.22.067.021.77 311.03.607.85

Performance Tables

Conditions Cooling Capacity COP / EER P1 [W] Current [A] Ref. mass flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
Evap. Temp. (°C/°F)
cond. pressure pc= 45/113220.5753189.81.174.001.01188.32.892.47
return gas temp. RGT= 32/90381.31302328.21.565.331.34244.53.184.31
546.01865469.91.906.491.64287.33.446.21
834.72851718.32.488.482.14336.23.779.62
liquid temp Tliq= 45/113956.43266823.12.749.352.36349.33.8711.09
1213.841451044.63.3211.342.86365.73.9914.26
Evap. Temp. (°C/°F)
cond. pressure pc= 55/131186.9638160.91.043.540.89180.62.842.31
return gas temp RGT= 32/90321.11097276.31.304.451.12246.43.194.00
463.11582398.61.555.301.34298.43.525.82
717.92452617.91.986.771.71362.33.979.16
liquid temp Tliq= 55/131826.92824711.62.177.401.87381.34.1110.62
1059.13617911.52.588.832.22409.74.3313.80

Configuration 2: RSCR

Model Designation: KLF6.6CNH

Voltage/Frequency: 115-127V/60Hz

Sales Code: 106H3700

Configuration Details

ParameterValue
MotorconfigurationRSCR
Power supply (nominal)115-127V/60Hz 1~
RefrigerantR290
ApplicationLBP+MBP
Voltage range95-140V
Starting torqueLST
ApprovalsUL, CCC

Electrical Accessories / Wiring Diagram

Diagram: Shows electrical accessories and wiring for the RSCR configuration, including components labeled a4, e, b, d, and e1.

Ambient/Machine Room Temperatures

ParameterRange
Ambient temperature range10 - 43°C / 50 - 110°F
Machine room temperature range10 - 48°C / 50 - 119°F
Compressor coolingfan 3m/s

Operation Pressure Range

Graph: Shows condensing pressure (sat. temp.) vs. evaporation pressure (sat. temp.) for Configuration 2. It indicates zones for continuous operation and transitory operation.

Graph: Shows condensing pressure [bara] vs. evaporation pressure [bara] for Configuration 2, indicating zones for continuous operation and transitory operation.

Components

Component IDDescriptionCode
a4DLS 6 (PTC, 6.3mm, T1141/L6 - S6)103N0214
eRun capacitor (15µF, 6.3mm)117-7153
b, dCover + clamp + screws (5VA-compl.)103N0600
e1Retaining clamp103N0535

Alternative Components

DescriptionCode
100x cover + clamp + screws (5VA)103N2060
Cover + clamp + screws (5VA) in bag103N1060

Optimization + Standard Conditions & Performance Tables (Conf. 2)

Conditions: R290, 115V/60Hz, RSCR, fan 3m/s, UL, CCC

Optimization + Standard Conditions

Conditions Cooling Capacity Power Consumption P1 [W] Current [A] Ref. mass flow [kg/h]
pe [°C]pc [°C]RGT Tliq [°C][W][Btu/h][kcal/h]COP [W/W]EER [Btu/Wh][kcal/Wh]
ASHRAE LBP -235432398.41360342.81.725.891.48 230.92.144.03
cecomaf LBP -255532298.51019256.91.354.601.16 221.52.063.72
EN12900 LBP -354020227.3776195.61.324.511.14 172.21.682.60
ASHRAE MBP -75435716.22446616.32.217.551.90 324.12.928.17
cecomaf MBP -105532568.41941489.21.856.311.59 307.92.787.19
EN12900 MBP -104520637.42177548.52.237.621.92 285.82.597.83

Performance Tables

Conditions Cooling Capacity COP / EER P1 [W] Current [A] Ref. mass flow [kg/h]
[W][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh]
Evap. Temp. (°C/°F)
cond. pressure pc= 45/113166.6569143.41.093.720.94153.01.541.86
return gas temp. RGT= 32/90223.4763192.31.274.351.10175.51.702.50
382.01305328.81.695.771.45226.32.104.31
545.31862469.32.067.041.77264.62.416.20
liquid temp Tliq= 45/113830.22835714.52.699.202.32308.32.789.57
949.73244817.42.9710.142.55320.02.8811.02
1201.141021033.73.5912.253.09334.83.0114.11
Evap. Temp. (°C/°F)
cond. pressure pc= 55/131139.4476120.00.983.330.84143.01.451.72
return gas temp RGT= 32/90187.0639160.91.103.760.95169.71.652.31
322.51102277.61.404.761.20231.22.144.02
464.61587399.81.665.671.43279.72.545.84
liquid temp Tliq= 55/131715.92445616.12.117.191.81339.93.059.14
822.22808707.62.307.841.98358.13.2110.56
1047.13576901.12.719.262.33386.13.4513.64

Service/Repair Information

Refrigerant: R290

Warning: Handle R290 refrigerant with care. ⚠️

Diagrams: Illustrate general assembly and service/repair procedures for KL Compressors, including specific steps and warnings related to handling refrigerant and components. The diagrams show various assembly configurations and connection points.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4695 GPL Ghostscript 10.05.1

Related Documents

Preview SECOP KLF6.6CNT Compressor Technical Data Sheet
Comprehensive technical data for the SECOP KLF6.6CNT compressor, detailing specifications, configurations (CSIR and RSCR), electrical data, operating pressure ranges, and performance tables for R290 refrigerant across various voltage and frequency settings (200-240V/50Hz and 208-230V/60Hz). Includes dimensions, application notes, and accessory information.
Preview Secop KLF6.6CNT Compressor Technical Data and Specifications
Detailed technical specifications, performance data, and configuration details for the Secop KLF6.6CNT compressor. Includes electrical data, dimensions, operating ranges, and component information for various configurations.
Preview Secop NLE11MN Compressor Technical Data and Specifications
Detailed technical specifications, performance data, configurations, dimensions, and electrical information for the Secop NLE11MN compressor, including CSIR and RSCR models for 115-127V 60Hz operation. Includes single pack contents, operating conditions, and service information.
Preview Secop NL8.4CNX.2 Compressor Technical Data and Specifications
Detailed technical data, specifications, dimensions, electrical information, and performance tables for the Secop NL8.4CNX.2 compressor, designed for 115V/60Hz operation with R290 refrigerant.
Preview Secop NLE11CNLT Compressor Technical Data and Specifications
Detailed technical data, specifications, dimensions, and performance tables for the Secop NLE11CNLT compressor, including CSIR, RSIR, and RSCR configurations. Information on operating conditions, electrical data, and mounting accessories.
Preview Secop NLE8.0CN Compressor Technical Data and Specifications
Detailed technical data, specifications, configurations, and performance tables for the Secop NLE8.0CN compressor, including electrical accessories, dimensions, and application notes. Suitable for R290 refrigerant.
Preview Secop NLE12.6CNS Compressor Technical Data
Detailed technical specifications, configurations, and performance data for the Secop NLE12.6CNS compressor, including electrical accessories, wiring diagrams, and operational parameters.
Preview Secop NLE11MNT Compressor Technical Data and Specifications
Comprehensive technical data, performance specifications, configurations, and service information for the Secop NLE11MNT 208-230V 60Hz CSIR compressor. Includes dimensions, electrical data, operating ranges, and wiring diagrams.