Introducing the DELUXE POWER INVERTER Series
Mitsubishi Electric's PUHZ-ZRP series represents the pinnacle of semi-industrial air conditioning systems, offering unparalleled energy efficiency within the Mr.SLIM range. These outdoor units are designed with advanced inverter technology and utilize environmentally friendly R410A refrigerant.
The PUHZ-ZRP series is engineered for superior performance, providing effective cooling and heating solutions. Key features include:
- Exceptional energy efficiency, leading the market for semi-industrial systems.
- Compatibility with R22 systems, allowing for a seamless upgrade path with special oils and filters, eliminating the need for pipe flushing.
- Flexibility in piping, accommodating various pipe diameters.
- A night mode function to reduce noise levels by 3-4 dB.
- The capability to form multi-systems, connecting up to four indoor units.
- An integrated refrigerant leak detection system for enhanced safety and performance.
Technical Specifications Overview
The following tables detail the specifications for single-phase and three-phase models:
Parameter | PUHZ-ZRP35VKA2 | PUHZ-ZRP50VKA2 | PUHZ-ZRP60VHA2 | PUHZ-ZRP71VHA2 | PUHZ-ZRP100VKA3 | PUHZ-ZRP125VKA3 | PUHZ-ZRP140VKA3 |
---|---|---|---|---|---|---|---|
Cooling Capacity (kW) | 3.6 | 5.0 | 6.1 | 7.1 | 9.5 | 12.5 | 13.4 |
Heating Capacity (kW) | 4.1 | 6.0 | 7.0 | 8.0 | 11.2 | 14.0 | 16.0 |
Power Input (kW) Cooling | 0.83 | 0.92 | 1.42 | 1.81 | 1.75 | 2.07 | 2.11 |
Power Input (kW) Heating | 1.42 | 1.81 | 1.75 | 2.07 | 2.23 | 3.87 | 4.39 |
EER (Cooling) | 4.32 | 3.53 | 3.49 | 3.80 | 4.26 | 3.23 | 3.05 |
COP (Heating) | 4.44 | 3.32 | 3.39 | 3.79 | 4.17 | 3.71 | 3.26 |
Max. Operating Current (A) | 13.2 | 13.2 | 19.2 | 19.3 | 27.0 | 27.2 | 28.7 |
Airflow Rate (m³/h) | 2700 | 2700 | 3300 | 3300 | 6600 | 7200 | 7200 |
Sound Pressure Level (dB(A)) Cooling | 44 | 44 | 47 | 47 | 49 | 50 | 50 |
Sound Pressure Level (dB(A)) Heating | 46 | 46 | 48 | 48 | 51 | 52 | 52 |
Weight (kg) | 43 | 46 | 70 | 70 | 116 | 116 | 118 |
Parameter | PUHZ-ZRP100YKA3 | PUHZ-ZRP125YKA3 | PUHZ-ZRP140YKA3 | PUHZ-ZRP200YKA3 | PUHZ-ZRP250YKA3 |
---|---|---|---|---|---|
Cooling Capacity (kW) | 9.5 | 12.5 | 13.4 | 19.0 | 22.0 |
Heating Capacity (kW) | 11.2 | 14.0 | 16.0 | 22.4 | 27.0 |
Power Input (kW) Cooling | 2.23 | 3.87 | 4.39 | 5.62 | 7.31 |
Power Input (kW) Heating | 2.69 | 3.77 | 4.90 | 6.10 | 7.92 |
EER (Cooling) | 4.26 | 3.23 | 3.05 | 2.94 | 2.65 |
COP (Heating) | 4.17 | 3.71 | 3.26 | 3.23 | 3.02 |
Max. Operating Current (A) | 8.5 | 10.2 | 13.7 | 19.0 | 21.0 |
Airflow Rate (m³/h) | 6600 | 7200 | 7200 | 8400 | 8400 |
Sound Pressure Level (dB(A)) Cooling | 49 | 50 | 50 | 59 | 59 |
Sound Pressure Level (dB(A)) Heating | 51 | 52 | 52 | 62 | 62 |
Weight (kg) | 124 | 126 | 132 | 135 | 135 |
Advanced Energy-Saving Technologies
Mitsubishi Electric has implemented several technological advancements to enhance the energy efficiency and performance of the PUHZ-ZRP series:
- Fan and Outdoor Unit Grille: Optimized fan blade design and modified outlet grille improve airflow and heat exchange, preventing noise increases.
- Heat Exchanger: A compact design with an enlarged surface area, utilizing 7.94 mm copper pipes for improved heat transfer efficiency.
- Super-cooling Function (for PUHZ-ZRP140): An integrated super-cooling circuit enhances energy efficiency during cooling operations by utilizing a sub-cooler to increase suction pressure, reducing compressor load.
Installation and Options
Detailed dimensions and installation space requirements are provided for various models to ensure proper setup. A range of optional accessories are available to customize system functionality, including:
- Signal line converters for system integration.
- Drainage fittings and trays for condensate management.
- Filter-dryers for refrigerant line protection.
- Windbreak panels for operation in low temperatures.
- Branch separators for multi-system configurations.
- Refrigerant charge adjustment guides for varying pipe lengths.
For comprehensive installation details and accessory information, please refer to the specific model documentation.