SATEL AGD-200 Wireless Glass-Break Detector Manual

SATEL AGD-200 Wireless Glass-Break Detector

Firmware Version: 1.00

Document Revision: agd-200_en 03/21

Manufacturer: SATEL sp. z o.o., Gdańsk, POLAND

Website: www.satel.eu

Important Information

The device must be installed by qualified personnel. Please read this manual carefully before installation. Unauthorized changes, modifications, or repairs will void your warranty rights. The device's rating plate is located on the enclosure base.

SATEL is committed to continuous product improvement, which may lead to changes in technical specifications and software. Current information on updates is available on the SATEL website. Visit https://support.satel.eu for details.

SATEL sp. z o.o. hereby declares that the radio equipment type AGD-200 complies with Directive 2014/53/EU. The full EU declaration of conformity is available at www.satel.eu/ce. In the EU, this equipment is permitted to operate exclusively in the 868 MHz frequency band.

Symbols used in this manual: ℹ️ - Note, ⚠️ - Caution.

Product Overview

The AGD-200 detector is designed to detect the breaking of plate, tempered, and laminated glass. It operates within the ABAX 2 / ABAX two-way wireless system. This manual applies to detectors with firmware version 1.00 or newer, compatible with:

  • ABAX 2: ACU-220 / ACU-280 controller, ARU-200 repeater.
  • ABAX: ACU-120 / ACU-270 controller (firmware v5.04+), ARU-100 repeater (firmware v2.02+), INTEGRA 128-WRL control panel (firmware v1.19+ and processor firmware v3.10+).

Features

  • Advanced two-path sound analysis.
  • Adjustable detection sensitivity.
  • Encrypted two-way radio communication in the 868 MHz / 915 MHz frequency band (AES standard for ABAX 2).
  • Transmission channel diversity (4 channels for automatic selection) for interference-free transmission (ABAX 2 only).
  • Remote firmware update capability (ABAX 2 only).
  • Remote configuration.
  • Built-in temperature sensor with a range of -10°C to +55°C.
  • "ECO" option for extended battery life (ABAX 2 only).
  • Battery status monitoring.
  • LED indicator.
  • Tamper protection against enclosure opening and removal from the mounting surface.

Description

Radio Communication

The detector communicates periodically with the controller/control panel to report its status. Additional communication occurs upon an alarm event, as detailed in "Operating modes".

Alarms

The detector reports an alarm under the following conditions:

  • Glass break detection: registering a low-frequency impact sound followed by a high-frequency glass break sound within 4 seconds.
  • Tamper alarm: opening of the tamper switch.

Operating Modes

  • Active: All alarms are reported immediately.
  • Passive: Only tamper alarms are reported immediately. This mode conserves battery life.

The detector's operating mode can be set remotely. In INTEGRA / VERSA systems, the mode may also depend on the partition state (disarmed = passive, armed = active). Refer to the ABAX 2 / ABAX controller manual or INTEGRA 128-WRL control panel manual for details.

Energy Saving Mode (ECO)

The "ECO" option, available in the ABAX 2 system, can extend battery life up to fourfold by changing periodical communication to every 3 minutes.

Test Mode

Test mode enables the LED indicator and allows alarm triggering solely by the high-frequency glass break sound, simplifying detector testing. Refer to the relevant system manuals for instructions on starting and ending test mode.

LED Indicator

The LED provides status feedback:

  • Warm-up: Flashes for approximately 3 seconds after battery insertion.
  • Periodical Communication: Short flash (80 milliseconds).
  • Low-frequency Sound: Flash (500 milliseconds).
  • Alarm: Solid ON for 2 seconds.

Battery Status Control

When battery voltage drops below 2.75 V, a low battery notification is sent with each transmission.

Electronics Board

⚠️ Do not remove the electronics board from the enclosure to prevent damage to its components.

Figure 1: Inside view of the detector after opening the enclosure, showing the tamper switch (1) and the CR123A lithium battery (2).

Selecting a Mounting Location

The detector is intended for indoor installation.

  • Position the detector's microphone towards the protected glass. The optimal mounting location is on the wall opposite the glass.
  • Ensure the distance between the detector and the glass does not exceed the detection range of 6 meters.
  • The detection range is influenced by room acoustics. Materials like shades, curtains, furniture upholstery, and acoustic tiles can absorb sound and reduce the effective range.
  • Avoid mounting the detector on the same wall as the glass pane or near sound-emitting devices such as loudspeakers, bells, or air conditioners.

Figure 2: Correct placement of the detector on the wall opposite the glass, within a 6m range (indicated by a green checkmark).

Figure 3: Incorrect placement of the detector on the same wall as the glass (indicated by a red cross).

Installation

⚠️ Battery Warning: Using a battery other than the one recommended by the manufacturer or improper handling can lead to battery explosion. Exercise extreme caution during battery installation and replacement. The manufacturer is not liable for consequences arising from incorrect battery installation. Used batteries must not be discarded; dispose of them according to environmental protection regulations.

  1. Open the detector enclosure. The enclosure opening tool is included in the delivery set (illustrated in Figure 4).
  2. Install the battery and add the detector to the wireless system. Refer to the ABAX 2 / ABAX controller manual or the INTEGRA 128-WRL control panel installer manual for instructions. The serial number for system registration is found on the electronics board.
  3. Note: In INTEGRA / VERSA alarm systems, the detector is identified as AGD-100. Simultaneous operation with both ABAX 2 and INTEGRA 128-WRL control panels is not supported.
  4. Close the detector enclosure.
  5. Place the detector at its intended installation location.
  6. Check the signal strength received by the ABAX 2 / ABAX controller or INTEGRA 128-WRL control panel. If the signal level is below 40%, choose an alternative location. Minor adjustments of 10-20 cm can sometimes significantly improve signal quality. Experiment with rotating the enclosure to assess the impact of antenna position on signal strength.
  7. The ARF-200 tester can be used to verify radio signal strength at the installation site without needing to mount the detector.
  8. Start the test mode (refer to the ABAX 2 / ABAX controller manual or INTEGRA 128-WRL control panel manual).
  9. Position the INDIGO TESTER near the protected glass and use it to simulate a glass-break sound. If the detector's LED illuminates, proceed with the installation. Otherwise, adjust the detection sensitivity (refer to system manuals) or select a new location and re-test, ensuring the signal level is rechecked.
  10. End the test mode.
  11. Open the detector enclosure again (as shown in Figure 4).
  12. Secure the enclosure base to the mounting surface using wall plugs (anchors) and screws (illustrated in Figure 6). The provided wall plugs are suitable for concrete and brick. For surfaces like drywall or styrofoam, use appropriate wall plugs.
  13. Close the detector enclosure.
  14. Configure the detector settings via the ABAX 2 / ABAX controller manual or the INTEGRA 128-WRL control panel manual.

Figure 4: Illustration of the enclosure opening procedure.

Figure 5: Detector dimensions: 102 mm (length) x 20 mm (width) x 23 mm (depth).

Figure 6: Securing the detector's mounting base to a wall using screws and wall plugs.

Specifications

Parameter Value
Operating frequency band 868.0 MHz – 868.6 MHz / 915 MHz – 928 MHz
Radio communication range (open area)
    ABAX 2 (ACU-220) up to 2000 m
    ABAX 2 (ACU-280) up to 1200 m
    ABAX up to 500 m
Battery CR123A 3 V
Battery life expectancy up to 2 years
Temperature measurement range -10°C to +55°C
Temperature measurement accuracy ±1°C
Standby current consumption 90 µA
Maximum current consumption 25 mA
Detection range up to 6 m
Complied with standards EN 50130-4, EN 50130-5, EN 50131-5-3
Environmental class (EN50130-5) II
Operating temperature range -10°C to +55°C
Maximum humidity 93±3%
Dimensions 20 x 102 x 23 mm
Weight 39 g
Models: AGD-200 Wireless Glass-Break Detector, AGD-200, Wireless Glass-Break Detector

File Info : application/pdf, 7 Pages, 253.16KB

PDF preview unavailable. Download the PDF instead.

agd-200 en f86f9a84

References

Microsoft Word 2016

Related Documents

Preview SATEL AOCD-260 Wireless Outdoor Dual Technology Curtain Detector Manual
User manual for the SATEL AOCD-260 wireless outdoor dual technology curtain detector. Covers features, description, alarms, operating modes, installation, and specifications. Compatible with ABAX 2 and ABAX systems.
Preview SATEL ACX-220 Hardwired Zone / Output Expander - Technical Manual
Comprehensive technical manual for the SATEL ACX-220 hardwired zone and output expander, detailing its features, specifications, electronics board, and installation procedures for ABAX 2 and ABAX wireless security systems.
Preview SATEL ASD-250 SK Bezdrôtový detektor dymu - Manuál
Komplexný manuál pre bezdrôtový detektor dymu SATEL ASD-250 SK. Obsahuje informácie o vlastnostiach, inštalácii, údržbe, technických špecifikáciách a prevádzkových režimoch.
Preview SATEL ASW-210: Flush-mounted Wireless 230 VAC Controller
Comprehensive guide to the SATEL ASW-210, a two-channel flush-mounted wireless 230 VAC controller. Covers features, technical specifications, wiring, installation, and operating modes for smart home and automation systems.
Preview SATEL ASD-250 PL Bezprzewodowa czujka dymu - Instrukcja Obsługi
Instrukcja obsługi bezprzewodowej czujki dymu SATEL ASD-250 PL. Zawiera informacje o właściwościach, opisie, montażu, konserwacji, czyszczeniu, wymianie baterii i danych technicznych.
Preview SATEL ACMD-200 DE Carbon Monoxide Detector Manual
Comprehensive manual for the SATEL ACMD-200 DE carbon monoxide detector, covering features, operation, installation, mounting, battery replacement, and technical specifications for both autonomous and ABAX 2 system use.
Preview Satel AFD-200 DE Funk-Wassermelder: Anleitung und technische Daten
Umfassende Anleitung für den Satel AFD-200 DE Funk-Wassermelder. Erfahren Sie mehr über Installation, Funktionen, technische Spezifikationen und wichtige Hinweise für Ihr Wassermeldesystem.
Preview SATEL VERSA Alarm Control Panel Quick User Manual
Quick user manual for the SATEL VERSA alarm control panel, covering keypad operation, arming/disarming, zone management, keyfob control, telephone operation, and the VERSA CONTROL mobile application.