User Guide for ZKTeco models including: G4, Multi-Biometric Identification Terminal

G4?Quick?Start?GuideV1.0 2018...

QUICK START GUIDE

QUICK START GUIDE Applicable Model: G4 Version:V1.0 Date: Oct 2018 Safety Precautions Before installation, please read the following precautions carefully


File Info : application/pdf, 1 Pages, 880.08KB

PDF preview unavailable. Download the PDF instead.

G4 Quick Start Guide
QUICK START GUIDE
Applicable Model: G4
Version: V1.0 Date: Oct 2018

Safety Precautions
Before installation, please read the following precautions carefully to prevent risks and dangers to this product, users and any other person.
Do not expose to direct sunlight, water, dust and soot. Do not place any magnetic objects near the product. Magnetic objects such as magnets, CRT, TV, monitors or speakers may damage the device. Do not place the device next to any heating equipment.
Prevent water, drinks or chemicals leaking into the device. This product is not intended for use by children unless they are supervised. Do not drop or damage the device.
Do not disassemble, repair or modify the device.
Do not use the device for any purpose other than those specified. Remove dusts or dirts regularly. While cleaning, wipe dust off with a smooth cloth or towel instead of water. Contact your supplier in case of any problem!

1.55m

User Registration
1) Recommended distance
For users with height from 1.5m to 1.8m, the recommended device height is 1.55m. It can be adjusted and installed according to the users' average height.

User Registration
3) Registration During registration, please adjust your position and keep your face inside the green frame.

1.55m 1.55m

The recommended position

The registration and verification position of the device should not be changed to avoid affecting the verification accuracy. If it is necessary to move the device, then move it horizontally and keep the vertical height same.

2) The recommended and not-recommended facial expressions:

8 7 6 5 4 3 2 1

ZK Building, Wuhe Road, Gangtou, Bantian, Buji Town, Longgang District, Shenzhen China 518129 Tel: +86 755-89602345 Fax: +86 755-89602394 www.zkteco.com
Ethernet & Power Connection
LAN Connection
PC
Power Connection
12V DC Adaptor
Recommended power supply Rating of 12V and 3A To share the device's power with other devices, use a power supply with higher current ratings. 7
Menu Functions
Enroll New User

1

Device Overview

Front

Side

Visible light camera

LED

IR camera LED

IR LED

7 Inch HD capacitive touch screen

IC Card Reader Fingerprint sensor

Speaker

Bottom

USB port Reset Button

4

Lock Relay Connection

The system supports Normally Opened Lock and Normally Closed Lock. The diagrams shown hereafter represents Normally Closed Lock.

Device not sharing power with the lock is shown below:

Lock Power NC Lock

FR107

DC12V

SEN GND BUT NO COM NC
+12V GND

Device sharing power with the lock is shown below:

NC Lock

FR107

SEN GND BUT NO COM NC

DC12V

+12V GND

8

Menu Functions
Access Settings

2
Device Overview
Product PIN Diagram

+12V GND IWD0 IWD1 WD0 WD1

Wiegand In Wiegand Power Out Output

NO COM NC
+12V GND

Power In

Lock

SEN GND BUT NO COM NC

Lock

Button Sensor

Tamper Switch

Ethernet port Power port
Product Dimensions

10.4in (264.0mm)

4.4in (112.0mm)

2.0in (51.0mm)
5

7.2in (182.8mm)
3.1in (79.5mm)

Connecting Other Devices
Button & Sensor Connection

Alarm Connection

Door Sensor
No Touch
EXIT
Exit Button

SEN GND BUT NO COM NC

Wiegand Connection

Alarm power Alarm

NO COM NC

Wiegand Reader

+12V GND IWD0 IWD1 WD0 WD1

Wiegand Device Wiegand In Port

9

Menu Functions
Record Search

3

Product Installation

Mounting the device on wall

1
1.2m

7

8

Mounting Hole

Mounting Hole

Mounting Hole

G4 Mounting template (Only for your reference)

Mounting Hole

Wiring Hole

Mounting Hole

9

10

Mounting Hole 11

Mounting Hole

Mounting Hole

Instruction for using this template:
12 Before installing the device, please paste this template onto the desired installation place, and then drill holes and lay cables according to the marks on the template.
13 Baseline

14 Recommended height from the ground is 1.2m
and can be adjusted according to the personnel
average height. 15

2

3

4




 Paste the mounting template sticker onto the wall, and drill holes according to it.
 Fix the back plate to the wall with wall mounting screws.  Attach the device to the back plate.  Fasten the device to the back plate with a security screw.

6
Standalone Installation

Option A

Option B

PC

WAN

TCP/IP WiFi

PC
SWITCH

Door Sensor Lock

Alarm Exit Button

10
Menu Functions & Troubleshooting
Date and Time Settings

Go to Main Menu > Access Settings > Access control parameters to enter Access control parameters setting interface.
Network Settings

Go to Main Menu > Employee Management > > New Employee > Enroll verification mode. Settings include entering Employee Name, ID, choosing User Role (Normal User is not authorized to operate the menu options of the device. Super Admin can operate all the menu options of the device), registering Fingerprint, Face Registration, Enroll Badge Number (ID and Mifare card are optional), and setting Password.
11

Go to Main Menu > System Settings > Network Settings, set the IP Address. The device will communicate with PC via the Ethernet parameters. Using Cloud Service Settings sets Server Address and Server port according to the server.
12

View records in the device: Go to Main Menu > Record Search > Att Log enter Name or Employee ID (if user ID field is left blank, records of all users will be displayed) > select Time Range > press OK, the corresponding attendance logs will be displayed.
View records on computer: Go to Main Menu> USB disk Management > USB disk Download. Insert the USB disk correctly and download the data to the USB drive, then copy this data from the USB drive to your PC. The downloaded data filename will be "Device Serial Number.dat", you can open and view it.

Go to Main Menu > System Settings > Date and Time, to enter Date and Time setting interface.
Troubleshooting
1. Fingerprint cannot be detected or it takes too long.
2. Failed to gain access after successful verification. 3. Door does not open after successful verification.

13

14



References

Acrobat Distiller 10.1.0 (Windows)