Product Overview for temperzone models including: temperzone, air conditioning, water conditioning, air distribution, ventilation, heating, split systems, ducted reverse cycle, packaged units, fan coil units, water heaters, Hitachi Cooling & Heating, R32, R410A, HVAC, climate innovations, LOKRING, FLEXALEN, Wilo pumps, Econorad, De Dietrich, Gassero, SmarTemp
Sep 1, 2024 — SALES (Head Office). Damon Clark ....................................... 021-835 291. - Auckland Regional Sales Manager. Branka Volc .
Premium Zone Control Interface Box (GC-AZKP)
Product Overview 1 September 2024 AIR CONDITIONING WATER CONDITIONING AIR DISTRIBUTION VENTILATION & HEATING DIRECTORY SALES (Head Office) Damon Clark ....................................... 021-835 291 - Auckland Regional Sales Manager Branka Volc ...................................... 027-294 3300 - Key Account Manager Bob Daw ............................................. 021-528 118 - Account Manager Grant Reynolds ................................ 0-27-704 7244 - Account Manager John Lusty .......................................... 09-279 5266 - Internal Sales Team Leader Mike West .......................................... 09-279 5263 - Engineering Estimator TECHNICAL SUPPORT / WARRANTY Hours 7.30 am 5.00 pm ................... 09-279-5251 Sean Christy - Tz Technical Support Engineer Ronald Serrato - Hitachi Technical Support Engineer Hardik Tanti - Technical Support Engineer ADMINISTRATION Bryan Waters ...................................... 09-279 5257 - National Sales Manager Jamie Nankivell .................................. 09-279 5256 - Marketing Manager Kylie Morey ................09-277 3191 / 021-196 4648 - Customer Care Manager Accounts Receivable ......................... 09-279 5254 SPARE PARTS / DESPATCH Hours 7.30 am 5.00 pm ................... 09-279 5253 RECEPTION ........................................ 09-279 5250 Facsimile ............................................ 09-275 5637 HAMILTON BRANCH Hours 8.00 am 4.30 pm ...................04-569 3262 Graham Lawes ................................. 0-27-562 6452 - Account Manager (Hamilton) WELLINGTON BRANCH Hours 8.00 am 4.30 pm ...................04-569 3262 Corbin Berriman ............................... 0-21-984 827 - Wellington Regional Manager Craig Levien ..................................... 0-21-558 758 - Account Manager Mark Jury ......................................... 021-454 0405 - Account Manager CHRISTCHURCH BRANCH Hours 8.00 am 4.30 pm ................. 03-379 3216 Tony Hansen ................................. 0-27-435 7203 - South Island Regional Manager Craig Wiffen..................................... 0-27-433 0550 - Account Manager Ian Kimpton..................................... 0-21-321 197 - Account Manager EMAIL ............................ nzsales@temperzone.com ............ customerservices@temperzone.com ................. nztechsupport@temperzone.com ................... nzspareparts@temperzone.com Contact Us AUCKLAND 38 Tidal Rd, Mangere South, 2022 Private Bag 93303, Otahuhu, 1640 Customer Services Ph. 0800-TZWARRANTY or 0-9-279 5251 HAMILTON 30 Gallagher Drive, Melville 3026 PO Box 15-058, Dinsdale 3243 Ph. 0-7-839 2705 WELLINGTON 6 Union Street, Petone 5012 Sales Office Ph. 0-4-569 3262 CHRISTCHURCH 40 Cass Street, Sydenham 8023 Sales Office Ph. 0-3-379 3216 WEBSITES www.temperzone.com www.temperzone.biz (Trade) www.hitachiaircon.co.nz Content Contact Us Contents Air Conditioning Split Systems - Ducted Reverse Cycle Split Systems - Accessories Controls LOKRING Packaged Units - Ducted Reverse Cycle Packaged Systems Accessories Vertical Packaged Units - Ducted Reverse Cycle Packaged Units - Ducted Water Cooled Chilled Water Fan Coil Units Chilled Water Air Handling Units Heat Pump Water Heaters Air Distribution Radial Swirl Diffusers RPD - Round Plastic Ceiling Diffusers Grilles Adaptors for Grilles Flexiduct, Duct Tape, Duct Joiners Air Regulating Damper, Custom Grilles Ventilation In-Line Centrifugal Fans Other Products Circulating Water Pumps Pre-Insulated Pipe Page 2 3 4 6 9 11 14 17 18 19 22 26 27 28 29 29 29 30 31 32 33 36 Hitachi refer dedicated Temperzone Account Manager for a catalogue or vist www.hitachiaircon.co.nz Contents 3 Air Conditioning t CONTENTS Split Systems - Ducted RRe3v2erse Cycle These new systems are MEPS compliant, ie they meet the Minimum Energy Performance Standards set out in AS/NZS 3823.2:2013 and use refrigerant R32, which has a low GWP. Each system includes a variable capacity inverter compressor enabling close temperature control. Inverters provide additional economy at part load. A wide range of unit sizes have been developed to meet the needs of any application, e.g. homes, apartments, offices, shop, restaurants, public and private areas of hotels, open plan office and work spaces, halls, hospitals and factories. Filter box c/w filter available. These ISD models are: separable (excl. 351), include high efficiency EC motors with optional 0-10V speed control, higher static performance, 12V control and include in-built safety drain tray. BMS/modbus compatibility is standard. ITEM NO. 845-171-001 846-171-001 DESCRIPTION Single Phase: ISD 171LYX OSA 171RLSFH UNIT NOMINAL NOMINAL COOLING HEATING kW kW Indoor 14.8 14.9 Outdoor (8.6~18.5) (7.0~18.3) 845-171-001 846-171-003 845-211-001 846-211-003 845-251-001 846-251-003 845-351-001 846-352-003 Three Phase: ISD 171LYX OSA 171RLTFH ISD 211LYX OSA 211RLTFH ISD 251LYX OSA 251RLTFH ISD 351LYX OSA 352RLTFV Indoor 14.8 14.9 Outdoor (8.6~18.5) (7.0~18.3) Indoor 19.5 20.85 Outdoor (9.4~25.3) (8.4~25.6) Indoor 23.3 23.3 Outdoor (13.3~29.5) (10.4~29.2) Indoor 32.7 31.3 Outdoor (13.5~37.1) (12.0~35.3) Note: ISD safety drain tray is built-in. Once separated, separable ISD units (up to 251) will fit through a clear aperture sized 550 mm sq. or more. Outdoor Unit complete with UC8 Controller, which is compatible with BMS/modbus Indoor Unit complete with IUC Controller. Room Temp. Controller can be direct connected to ISD indoor or OSA outdoor unit Outdoor unit is pre-charged with refrigerant for 15m (OSA 171251) or 10m (OSA 352) of interconnecting pipe. OPTIONS: SAT-3 Room Temperature Controller 6 Zone Control Kit for use with SAT-3 TZT-100 Room Temperature Controller ISD Filter Box c/w filter ISD Supply & Return Air Plenums ISD Spigot Plate adaptors (for unit separation) ISD Spring Mounting Kit OSA Louvre Guard Kit (OSA 171/211/251) OSA 171/211/251 c/w Louvre Guards; made-to-order; POA OSA Anti-vibration mounts OSA Wall mounting kit (OSA 171/211) Refer to Accessories on page 8; Controls page 11. 244-002-308 244-002-309 244-002-310 LOUVRE GUARDS KIT (Supplied separately) : for OSA 171 for OSA 211 for OSA 251 Nomenclature Suffixes: R Reverse cycle system L Refrigerant R32 S Single phase power supply T Three phase power supply H Horizontal discharge fans V Vertical discharge fans Y EC motor fan F Inverter compressor system X Includes IUC. 4 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Split Systems - Ducted Reverse Cycle These new systems are MEPS compliant, ie they meet the Minimum Energy Performance Standards set out in AS/NZS 3823.2:2013 and use refrigerant R410A. A wide range of unit sizes have been developed to meet the needs of any application, e.g. homes, apartments, offices, shop, restaurants, public and private areas of hotels, open plan office and work spaces, halls, hospitals and factories. These dual compressor systems enable staged capacity performance. Digital systems have a finer variable capacity ability for close control applications. diGital ITEM NO. 525-501-601 525-501-001 525-511-001 526-501-201 525-611-001 525-621-001 526-651-201 525-591-201 525-591-211 525-601-201 525-601-211 526-641-201 525-631-201 525-631-211 525-641-201 525-641-211 526-671-201 525-501-601 525-501-001 525-511-001 536-501-201 525-661-223 525-671-201 526-731-223 525-701-201 525-711-201 526-741-223 DESCRIPTION UNIT NOMINAL COOLING kW Dual Compressor Systems Three Phase without Controls: ISD 380KBY Indoor ISD 380KBH-P* EC Plug Indoor ISD 380KBV-P* EC Plug Indoor OSA 380RKTBV (6) Outdoor ISD 465KBH ISD 465KBV* OSA 465RKTBV (6) Indoor Indoor Outdoor ISD 570KBH Indoor ISD 570KBV* Indoor ISD 570KBH-P* EC Plug Indoor ISD 570KBV-P* EC Plug Indoor OSA 570RKTBV (6) Outdoor ISD 670KBH Indoor ISD 670KBV* Indoor ISD 670KBH-P* EC Plug Indoor ISD 670KBV-P* EC Plug Indoor OSA 670RKTBV (6) Outdoor 37.2 37.4 " 44.6 " 56.1 56.6 65.9 " 65 NOMINAL HEATING kW 38.3 38.5 " 440 " 55.9 53.4 62.8 " 62 Digital Compressor Systems ISD 380KBY Indoor ISD 380KBH-P* EC Plug Indoor ISD 380KBV-P* EC Plug Indoor OSA 380RKTBGV(6)* Outdoor ISD 840KBXH-P EC Plug Indoor ISD 840KBXV-P* EC Plug Indoor OSA 840RKTBGV (8) Outdoor ISD 950KBXH-P EC Plug Indoor ISD 950KBXV-P* EC Plug Indoor OSA 950RKTBGV (8) Outdoor 37.4 37.4 " 84.6 " 93.0 " 35.7 38.5 " 78.3 " 90.4 " Nomenclature Suffixes: K Refrigerant R410A B Twin system G Digital compressor sys. H Horizontal supply air P Plug/EC motor V Vertical supply air Y EC motor 1 September 2024 Note: * Not a stock item; made to order. (6) (8) Complete with UC6 or UC8 Controller, respectively. Above models include 24V control. Outdoor unit is precharged with refrgerant for 10m of interconnecting pipe. OPTIONS: Refer to Accessories pages 811. Factory fitted options: SAT-3 Controller, TZT-100 Controller, TZT-701 Controller, Electric Heat. Digital compressor version (ie 1 digital + 1 fixed) www.temperzone.biz 5 Air Conditioning Split Systems - Accessories ITEM NO. DESCRIPTION 492-000-004 492-000-005 492-000-030 SUPPLY AIR PLENUMS (Round Spigots) : for ISD 171LYX (2 x 400 dia.) for ISD 211/251 LYX (3 x 400 dia.) for ISD 351LYX (4 x 400 dia.) No. of inlets/outlets varies 492-100-004 492-100-005 492-100-006 492-100-008 RETURN AIR PLENUMS (Round Spigots) : for ISD 171LYX (2 x 400 dia.) for ISD 211LYX (2 x 400 dia.) for ISD 251LYX (3 x 400 dia.) for ISD 351LYX (4 x 400 dia.) t CONTENTS 325-000-051 325-000-052 FRESH AIR INLET SPIGOTS (for R/A Plenums) : for ISD 171/211 LYX (150 dia.) for ISD 251/351 LYX (200 dia.) 525-271-705 525-311-715 525-311-715 SPIGOT PLATE ADAPTORS : For rejoining gap between separable units (2 required) for ISD 171LYX (Ø400 mm x 2) for ISD 211LYX (Ø450 mm x 2) for ISD 251LYX (Ø450 mm x 2) Refer page 40 for flexible ducting. 493-000-004 493-000-006 493-000-007 493-000-016 525-501-605 FILTER BOX c/w washable* synthetic fibre filter media (Supplied separately) : for ISD 171LYX (EU2/G2 filter) for ISD 211LYX (EU2/G2 filter) for ISD 251LYX (EU4/G4 filter) for ISD 351LYX (EU4/G4 filter) for ISD 380KB(Y)(-P) (EU2/G2 filter) * Except for EU4/G4 rated filters which are disposable 307-161-101 307-341-101 SPRING MOUNTING KIT : for ISD 171251LYX (No.2) for ISD 351LYX, ISD 380KBY (No.3) 6 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Split Systems - Accessories ITEM NO. DESCRIPTION ANTI-VIBRATION MOUNTS (Rubber) : 060-000-170 for OSA 171352 Outdoor Units (set of 4) 526-061-007 WALL MOUNTING KIT : Powder coated galv. steel (SWL 185kg) for OSA 171211 (H) FAULT INDICATOR (Supplied separately) : 201-000-105 Fault Indicating Auxiliary Relay Board DRAIN CONNECTION ADAPTOR (25/13mm) (Supplied separately) : 060-000-039 for OSA 171352 119-000-080 119-000-082 REPLACEMENT FILTERS (EU2/G2 rated, washable synthetic fibre): for ISD 171LYX for ISD 211LYX 019-400-002 019-400-003 019-400-003 REPLACEMENT FILTERS (EU4/G4 rated, disposable): ISD 251LYX - 3 required in total 400 x 500 x 50 - 2 required 400 x 625 x 50 - 1 required. ISD 351LYX 400 x 625 x 50 - 3 required 1 September 2024 www.temperzone.biz 7 Air Conditioning t CONTENTS Split Systems - Accessories ITEM NOI. DESCRIPTION 019-400-008 019-400-010 019-400-004 019-400-008 019-400-004 019-400-008 019-400-009 019-400-008 FILTERS (Disposable, supplied separately) : ISD 465KB Filters (rated EU4) - 6 required in total: 450 x 500 x 50 - 3 required 450 x 600 x 50 - 3 required ISD 570/670KB Filters (rated EU4) - 6 required in total: 500 x 500 x 50 - 2 required 450 x 500 x 50 - 4 required ISD 840KB Filters (rated EU4) - 8 required in total: 500 x 500 x 50 - 4 required 450 x 500 x 50 - 4 required ISD 950KB Filters (rated EU4) - 13 required in total: 250 x 400 x 50 - 5 required 450 x 500 x 50 - 8 required 019-000-038 019-000-040 019-000-033 019-000-038 019-000-033 019-000-038 019-000-039 019-000-038 201-000-129 201-000-386 201-000-105 201-000-037 201-000-190 019-000-041 019-500-100 FILTERS (Washable, aluminium frame, supplied separately)* : ISD 465KB Filters (rated EU4) - 6 required in total: 450 x 500 x 50 - 3 required 450 x 600 x 50 - 3 required ISD 570/670KB Filters (rated EU4) - 6 required in total: 500 x 500 x 50 - 2 required 450 x 500 x 50 - 4 required ISD 840KB Filters (rated EU4) - 8 required in total: 500 x 500 x 50 - 4 required 450 x 500 x 50 - 4 required ISD 950KB Filters (rated EU4) - 13 required in total: 250 x 400 x 50 - 5 required 450 x 500 x 50 - 8 required * NB. These accessories can be field fitted. If accessories are requested to be fitted by temperzone, then a stock unit modification fee is applicable to items purchased from stock. This fee does not apply to units made to order. Filter sizes are nominal; refer to Temperzone for actual measurements. MISCELLANEOUS ACCESSORIES : Signal Isolator for EC Motor (ie Y models) using 0-10V fan speed control option (provided by t/stat or BMS by others) Signal Input 0-10V for OSA digital models (UC7) with Controller by others Fault Indicating Auxilary Relay Board Electrical Filter Indoor Coil Sensor Installation Kit Magnehelic Guage 0500 Pa Manometer 0750 Pa 8 www.temperzone.biz 1 September 2024 t CONTENTS Controls Air Conditioning ITEM NO. DESCRIPTION 201-000-146 201-000-074 201-000-075 201-000-077 201-000-116 201-000-073 201-000-195 201-000-047 221-000-123 221-000-124 221-000-125 221-000-126 temperzone SAT-3 ROOM TEMPERATURE CONTROLLER : for ISD-KYX/OSA 116351 (c/w IUC/UC8) Accessories: Interface cable - 10m (4 core shielded twisted pair) Interface cable - 20m (4 core shielded twisted pair) Interface cable - 30m (4 core shielded twisted pair) Optional: Remote Return Air duct sensor c/w 5 m lead Zone Control Kit (26 zones)(excl. ISD 87), 26 sensors and dampers required Remote Wall Mtd Air Sensor in box, excludes lead, switchable single or twin bead Sensor lead (excludes sensor) - 6 m Zone Damper 24V 200 dia. Zone Damper 24V 250 dia. Zone Damper 24V 300 dia. Zone Damper 24V 350 dia. 525-001-016 Optional: 201-000-116 201-000-026 201-000-034 201-000-063 201-000-024 201-000-036 201-000-032 temperzone SAT-2.1 THERMOSTAT KIT : for retro-fitting to 24V single & two stage sys. (incl. 10m interface cable to wall plaque) suits ISD 380950 K and OPA 116/161/186/242/294/370/465/550/850/960 RKT Remote Return Air Duct Sensor c/w 5 m lead Interface Cable (to wall plaque) - 10 m Interface Cable (to wall plaque) - 20 m SAT Infra Red Remote Controller Slimline SAT-2.1 Wall Control plaque (additional) temperzone Zone Control Kit for SAT-2.1 SAT-2 Zone Control Kit Transformer for SAT-2, 230V/10V 201-000-350 201-000-074 201-000-075 201-000-077 201-000-116 201-000-195 201-000-046 201-000-047 201-000-048 201-000-049 201-000-071 201-000-070 temperzone TZT-100 THERMOSTAT : for use with units fitted with IUC and/or UC6/UC7/UC8 Controllers, including digitals, but not suitable four units supplied with Economiser dampers. TZT-100 Wall Plaque (excl. cable) Accessories: Interface cable - 10m (4 core shielded twisted pair) Interface cable - 20m (4 core shielded twisted pair) Interface cable - 30m (4 core shielded twisted pair) Optional: Remote Return Air Duct Sensor c/w 5 m lead (can only be used as a single sensor, not for averaging) Remote Wall Mtd Air Sensor in box, excludes lead, switchable single or twin bead Sensor lead (excludes sensor) - 1.5 m Sensor lead (excludes sensor) - 6 m Sensor lead (excludes sensor) - 12 m Sensor lead (excludes sensor) - 25 m Easy Zone Touch (EZT) Wall Plaque Zone Relay Board (EZT) c/w housing 1 September 2024 www.temperzone.biz 9 Air Conditioning t CONTENTS Controls ITEM NO. DESCRIPTION 201-000-700 temperzone WIFI SERVICE UTILITY (WSU) for use with units fitted with UC6/UC7/UC8 Controllers View a unit's operating data using a WiFi connection and web browser on your mobile device. Data is viewed in real time and can be used to record commissioning status and diagnose operational faults. A running history can also be retrieved. WiFi Service Utility (WSU) 201-000-867 201-000-378 SERVICE INTERFACE DISPLAY (pGDN1) Operating pressures, superheat, set-point, compressor amps, etc and status can be read from its various display screens, including history. Avoids the need to connect guages UC6 Service Inferface device (excl. cable) Communications cable 3m (for the above) 525-001-015 temperzone TZT-701 THERMOSTAT KIT (While stocks last) : for retro-fitting on ISD/OSA 840,950RKT (non-UC6/UC7/UC8), (24V single & two stage systems) Accessories & Optional items: All items as listed above for the TZT-100 Controller Replacement Parts ITEM NO. DESCRIPTION 201-000-485 201-000-100 201-000-149 201-000-101 201-000-102 201-000-103 201-000-110 201-191-001 201-000-031 201-000-001 525-001-014 525-001-016 201-000-042 UC6 Controller (Twin fixed speed comp.) refer temperzone for other variations UC8 Controller refer tz Tech. Support for appropriate version Outdoor Unit Controller (OUC4) IUC Indoor Unit Controller Sensor (S/valve) - red lead 2m Sensor (HPC) - yellow lead 2m Sensor (De-Ice) - blue lead 2m HP Fan Speed Controller Electronic De-Ice (R22 sys.) SAT-1 Controller board (PCB) SAT-2.1 Controller board (PCB) SAT-2.1 Thermostat Kit 230V SAT-2.1 Thermostat Kit 24V TZT-701 Wall Control plaque 10 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning LOKRING Solder-free Tube Connectors 460-000-001 460-000-010 Tooling LOKbox MZ-V MB 0835 for 6/8/9.5/13/16/19/22/28/35mm dia. pipe LOKtool MB 25 EVP Assembly Jaws (2 req'd) $67.00 ea. for 25mm dia. pipe 460-000-020 460-000-021 460-000-022 460-000-023 460-000-024 LOKprep Solution HT 15 ML (use in ambients from 25°C) HT 50 ML " " " " " LT 15 ML (use in ambients up to 30°C) LT 50 ML " " " " " Abrasive mat 3 pack 460-000-030 460-000-031 460-000-032 460-000-033 460-000-034 460-000-035 460-000-037 460-000-038 Straight Brass Connectors 6.35 (1/4") NK Ms 50 9.53 (3/8") NK Ms 50 12.7 (1/2") NK Ms 50 16 (5/8") NK Ms 50 19 (3/4") NK Ms 50 22 (7/8") NK Ms 50 28 (1 1/8") NK Ms 50 35 (1 3/8") NK Ms 50 460-000-064 460-000-040 460-000-065 460-000-041 460-000-042 460-000-043 460-000-044 460-000-045 460-000-046 460-000-047 460-000-048 460-000-050 460-000-051 460-000-052 460-000-060 460-000-061 460-000-062 460-000-067 Reducer Brass Connectors 8.00 / 6.35 NR Ms 50 9.53 / 6.35 NR Ms 50 9.50 / 8.00 NR Ms 50 12.7 / 6.35 NR Ms 50 12.7 / 9.53 NR Ms 50 16 / 6.35 NR Ms 50 16 / 9.53 NR Ms 50 16 / 12.7 NR Ms 50 19 / 9.53 NR Ms 50 19 / 12.7 NR Ms 50 19 / 16 NR Ms 50 22 / 12.7 NR Ms 50 22 / 16 NR Ms 50 22 / 19 NR Ms 50 28.6 / 16 NR Ms 50 28.6 / 19 NR Ms 50 28.6 / 22 NR Ms 50 35 / 28.6 NR Ms 50 1 September 2024 www.temperzone.biz 11 Air Conditioning t CONTENTS LOKRING Solder-free Tube Connectors (cont'd) 460-000-070 460-000-089 460-000-073 460-000-076 460-000-077 460-000-079 460-000-080 460-000-081 460-000-084 460-000-087 460-000-085 460-000-086 460-000-090 Stabilisation Inserts 6.35 (1/4") - for 0.8 mm walled tube * 8.00 (5/16") - for 0.8 mm wall tube 9.53 (3/8") - for 0.8 mm wall tube * 12.7 (1/2") - for 0.8 mm wall tube 12.7 (1/2") - for 0.9 mm wall tube * 16 (5/8") - for 0.8 mm wall tube * 16 (5/8") - for 1.0 mm wall tube 19 (3/4") - for 1.0 mm wall tube * 19 (3/4") - for 1.1 mm wall tube 22 (7/8") - for 1.1 mm wall tube 22 (7/8") - for 1.4 mm wall tube 28 (1 1/8") - for 1.2 mm wall tube 35 (1 3/8") - for 1.5 mm wall tube * Use with temperzone Copper Pipe (page12). Note: To ensure a leak free joint it is important to use a Lokring stablisation insert designed to match the wall thickness of your copper tube. 460-000-100 460-000-101 460-000-102 460-000-103 460-000-104 460-000-105 460-000-106 Elbow Copper Connectors* 9.35 (3/8") Cu 90° EB 12.7 (1/2") Cu 90° EB 16 (5/8") Cu 90° EB 19 (3/4") Cu 90° EB 22 (7/8") Cu 90° EB 28 (1 1/8") Cu 90° EB 35 (1 3/8") Cu 90° EB * Complete with inserts but need Straight Brass Connectors for each end (see p.12) WARRANTY: 12 months on tools. 12 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Packaged Units - Ducted Reverse Cycle These are single piece, air cooled, roof top units that provide a three phase, ducted, reverse cycle package. The OPA range has been developed to meet the needs of light commercial and retail premises, e.g. offices, motels, restaurants and shops. These new systems are MEPS compliant and use refrigerant R410A. ITEM NO. MODEL Single Compressor Systems 556-051-701 OPA 116RKTYH (7) 556-091-701 OPA 161RKTYH (7) 556-101-701 OPA 186RKTYH (7) 556-111-601 OPA 201RKTYH (7) NOMINAL COOLING kW 11.6 16.1 18.6 20.0 NOMINAL HEATING kW 10.8 14.4 16.2 19.0 OPA 100201 (NB no Economiser option) Eco Systems (Variable capacity + EC motor/s) 566-101-701 OPA 186RKTYGH (7) 7.4~18.6 566-111-601 OPA 201RKTYGH (7) 8.0~20.0 Note: (7) Complete with UC7 Controller. OPTIONS TZT-100 Controller: refer page 9. 2.4~16.2 2.7~18.1 Packaged Units - Ducted RRe3v2erse Cycle Econex are the next generation inverter models, using R32 refrigerant for a lower GWP, and high static EC plug fans and axial fans. Units include electronic expansion valves (EEV). Opposite handing, Economiser (with or without Viking) and Fresh Air options available. Refer to Temperzone for further information. These are single piece, air cooled, roof top units that provide a three phase, ducted, reverse cycle package. The OPA range has been developed to meet the needs of light commercial and retail premises, e.g. offices, motels, restaurants and shops. These new systems are MEPS compliant and use refrigerant R32. 1 September 2024 ITEM NO. MODEL Single Compressor Systems NOMINAL COOLING kW Econex Systems (Inverter variable capacity + EC motor/s) 876-025-701 876-025-723 OPA 250RLTFPQ01 (8) 24.6 OPA 250RLTFPQ23* (8) (10.1~29.1) 876-035-701 876-035-723 OPA 350RLTFPQ01 (8) 34.8 OPA 350RLTFPQ23* (8) (18.0~45.4) 876-045-701 876-045-723 OPA 450RLTFPQ01 (8) 43.3 OPA 450RLTFPQ23* (8) 18.2~52.4 876-056-701 876-056-723 OPA 560RLTFPQ01 (8) 53.5 OPA 560RLTFPQ23* (8) (27.4~64.8) Econex Systems c/w Economiser (control by others) 877-025-701 877-025-723 OPA 250RLTFPQ01-Z* (8) 24.6 OPA 250RLTFPQ23-Z (8) (10.1~29.1) 877-035-701 877-035-723 OPA 350RLTFPQ01-Z* (8) 34.8 OPA 350RLTFPQ23-Z (8) (18.0~45.4) 877-045-701 877-045-723 OPA 450RLTFPQ01-Z* (8) 43.3 OPA 450RLTFPQ23-Z (8) 18.2~52.4 877-056-701 877-056-723 OPA 560RLTFPQ01-Z* (8) 53.5 OPA 560RLTFPQ23-Z (8) (27.4~64.8) Note: * Not a Stock Item (8) Complete with UC8 Controller. OPTIONS Filters Drain tundish set TZT-100 Controller; refer page 9 CTC-1 Climate Touch Controller (coming soon) Economiser with Viking Controller Fresh Air Cowl www.temperzone.biz NOMINAL HEATING kW 26.9 (6.5~29.3) 37.0 (13.9~47.0) 44.4 16.5~54.5 57.0 (24.0~63.1) 26.9 (6.5~29.3) 37.0 (13.9~47.0) 44.4 16.5~54.5 57.0 (24.0~63.1) Nomenclature OPA Suffixes: R Reverse cycle system K Refrigerant R410A L Refrigerant R32 T Three phase power supply H Horizontal supply/return air Y EC indoor air fan motor P EC Plug fan G Digital scroll compressor F Inverter compressor system Q EC outdoor fan Z Economiser (excl. controls) 01 Horizontal supply/return air 10 Opposite Hand version 23 Downward supply/return air 32 Opposite Hand version 13 Air Conditioning Packaged Units - Ducted Reverse Cycle The Eco Series provides added economy, flexibility and performance through using variable capacity compressors, high static EC motor plug fan technology and EEV valves (except 186/201). compliant and use refrigerant R32. ITEM NO. 866-071-701 866-071-723 MODEL OPA 705RKTBG01-P (8) OPA 705RKTBG23-P * NOMINAL NOMINAL COOLING HEATING kW kW 14~69.7 " 13.5~67.5 " Note: * Not a Stock Item. 8) Complete with UC8 Controller. OPA 705 Eco model has a variable + fixed speed compressor combination. OPA 855 Eco model includes two variable speed (digital) compressors. OPTIONS Filters; refer page 16. TZT-100 Controller, SAT-3 Controller kit for UC8 models; refer page 9. Opposite hand versions (OPA 705/855 Eco) Economiser and/or Viking Controller (OPA 705/855), Fresh Air Kit (OPA 705/855). t CONTENTS 14 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Packaged Units - Ducted ReRv3e2rse Cycle Econex goes one step further by including Inverter compressors. These are single piece, air cooled, roof top units that provide a three phase, ducted, reverse cycle package. The OPA range has been developed to meet the needs of light commercial and retail premises, e.g. offices, motels, restaurants, theatres, supermarkets and shopping malls. These new systems are MEPS compliant and use refrigerant R32. ITEM NO. MODEL NOMINAL COOLING kW NOMINAL HEATING kW Econex Systems (Inverter + Fixed for variable capacity + EC motor/s) 866-082-701 OPA 820RLTB1FPQ01 (8) 11~84 10~87 866-082-723 OPA 820RLTB1FPQ23 (8) " " 866-097-701 OPA 970RLTB1FPQ01 (8) 15~99 14~96 866-097-723 OPA 970RLTB1FPQ23 (8) " " 866-141-701 866-141-723 866-171-701 866-171-723 OPA 1410RLTM1FPQ01 (8) OPA 1410RLTM1FPQ23 (8) OPA 1710RLTM1FPQ01 (8) OPA 1710RLTM1FPQ23 (8) 12~189 " 17~177 " 13~181 " 15~182 " 866-211-701 866-211-723 OPA 2110RLTM1FPQ01 (8) OPA 2110RLTM1FPQ23 (8) 31~209 " 15~206 " 867-082-701 867-082-723 Economiser versions (excl. controls): OPA 820RLTB1FPQ01-Z (8) 11~84 OPA 820RLTB1FPQ23-Z (8) " 10~87 " 867-097-701 867-097-723 OPA 970RLTB1FPQ01-Z (8) OPA 970RLTB1FPQ23-Z (8) 15~99 " 14~96 " 867-141-701 867-141-723 OPA 1410RLTM1FPQ01-Z (8) OPA 1410RLTM1FPQ23-Z (8) 12~189 " 13~181 " 867-171-701 867-171-723 OPA 1710RLTM1FPQ01-Z (8) OPA 1710RLTM1FPQ23-Z (8) 17~177 " 15~182 " 867-211-701 867-211-723 OPA 2110RLTM1FPQ01-Z (8) OPA 2110RLTM1FPQ23-Z (8) 31~209 " 15~206 " Econex Pro Systems (Inverter variable capacity + EC motor/s) * 876-097-701 OPA 970RLTB2FPQD01 (8) 16~102 13~110 876-097-723 OPA 970RLTB2FPQD23 (8) " " 876-141-701 876-141-723 876-171-701 876-171-723 OPA 1410RLTM4FPQD01 (8) OPA 1410RLTM4FPQD23 (8) OPA 1710RLTM4FPQD01 (8) OPA 1710RLTM4FPQD23 (8) 12~190 " 15~206 " 12~190 " 15~214 " 876-211-701 876-211-723 OPA 2110RLTM4FPQD01 (8) OPA 2110RLTM4FPQD01 (8) 27~239 " 15~244 " 877-097-701 877-097-723 Economiser versions (incl. controls): OPA 970RLTB2FPQ01-Z (8) 16~102 OPA 970RLTB2FPQ23-Z (8) " 13~110 " 877-141-701 877-141-723 877-171-701 877-171-723 877-211-701 877-211-723 OPA 1410RLTM4FPQ01-Z (8) OPA 1410RLTM4FPQ23-Z (8) OPA 1710RLTM4FPQ01-Z (8) OPA 1710RLTM4FPQ23-Z (8) OPA 2110RLTM4FPQ01-Z (8) OPA 2110RLTM4FPQ23-Z (8) 12~190 " 115~206 " 27~239 " 12~190 " 15~214 " 15~244 " NEW Nomenclature OPA Suffixes: R Reverse cycle system K Refrigerant R410A L Refrigerant R32 T Three phase power supply B Dual compressor system M Multiple compressor system P EC Plug fan G Digital scroll compressor F Inverter compressor system D Advanced controller Q EC outdoor fans Z Economiser (excl. controls) 01 Horizontal supply/return air 10 Opposite Hand version 23 Downward supply/return air 32 Opposite Hand version 1 September 2024 Econex units use a mix of inverter + fixed compressors, and using R32 refrigerant for a lower GWP. More suited to external BMS control applications. Economiser (-Z) models include dampers c/w motors and cowl; no controls. Econex Pro units include a sophisticated Carel c.pCO programmed logic controller and four inverters. Particularly suited to supermarkets and process applications where humidity control is important. Made to order. Refer to Temperzone for further information. * Start-up Commissioning by Temperzone is a warranty requirement on Econex Pro models, and varies dependant on location of install. (8) Complete with UC8 slave controllers. OPTIONS Filters (p.16), TZT-100 Thermostat for Econex model only (excl. -Z variant) (p.9), Remote Service Inferface Device (pGD1) for Econex Pro (p.18). Options: Opposite hand versions, Reheat coil versions, Economiser version (NB controls by others on Econex model). Economiser & Spill Air (Bottom Return Air configurations only). www.temperzone.biz 15 Air Conditioning t CONTENTS Packaged Systems Accessories ITEM NO. DESCRIPTION 019-400-005 019-400-001 019-400-005 019-400-004 019-400-005 019-400-008 019-400-004 019-400-005 019-400-007 019-400-005 019-400-004 019-400-005 FILTERS (Disposable, supplied separately)* : OPA 250 Filters (rated EU4) : Filter size 600 x 500 x 50 - 2 required OPA 350 Filters (rated EU4) - 3 required in total: Filter size 600 x 300 x 50 - 1 required Filter size 600 x 500 x 50 - 2 required OPA 450 Filters (rated EU4) : Filter size 500 x 500 x 50 - 4 required OPA 560 Filters (rated EU4) : Filter size 600 x 500 x 50 - 4 required OPA 705 Filters (rated EU4) Filter size 450 x 500 x 50 - 9 required OPA 820, 970 Filters (rated EU4) Filter size 500 x 500 x 50 - 9 required OPA 1410 Filters (rated EU4) - 9 required in total: Filter size 600 x 500 x 50 - 3 required Filter size 600 x 600 x 50 - 6 required OPA 1710 Filters (rated EU4) - 12 required in total: Filter size 600 x 500 x 50 - 12 required OPA 2110 Filters (rated EU4) - 16 required in total: Filter size 500 x 500 x 50 - 12 required Filter size 600 x 500 x 50 - 12 required 019-000-034 019-000-037 019-000-034 019-000-033 019-000-034 019-000-038 019-000-033 019-000-034 019-000-031 019-000-034 019-000-033 019-000-034 FILTERS (Washable, aluminium frame, supplied separately)* OPA 250 Filters (rated EU4) : Filter size 600 x 500 x 50 - 2 required OPA 350 Filters (rated EU4) - 3 required in total: Filter size 600 x 300 x 50 - 1 required Filter size 600 x 500 x 50 - 2 required OPA 450 Filters (rated EU4) : Filter size 500 x 500 x 50 - 4 required OPA 560 Filters (rated EU4) : Filter size 600 x 500 x 50 - 4 required OPA 705 Filters (rated EU4) Filter size 450 x 500 x 50 - 9 required OPA 820, 970 Filters (rated EU4) Filter size 500 x 500 x 50 - 9 required OPA 1410 Filters (rated EU4) - 9 required in total: Filter size 600 x 500 x 50 - 3 required Filter size 600 x 600 x 50 - 6 required OPA 1710 Filters (rated EU4) - 12 required in total: Filter size 600 x 500 x 50 - 12 required OPA 2110 Filters (rated EU4) - 16 required in total: Filter size 500 x 500 x 50 - 12 required Filter size 600 x 500 x 50 - 4 required ANTI-VIBRATION MOUNTS (Rubber) : 060-000-170 for OPA 116201 (set of 4) CONDENSATE DRAIN TUNDISH (25 OD/21 ID) : 060-000-653 for OPA 250560, 970 outdoor section (set of 2) * Note: These accessories are for fitting in the field. Filter sizes are nominal; refer to Temperzone for actual measurements. 16 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Packaged Systems Accessories (cont'd) ITEM NO. DESCRIPTION 201-000-867 SERVICE INTERFACE DISPLAY (pGDN1) Wired remote for OPA units with Carel c.pCO Controller. Up to 50m separation using telephone cable (RJ11), or up to 200m using AWG24 shielded cable and card adaptor (not supplied). Setpoint, humidity, schedule, operating pressures, superheat, compressor amps, alarms, etc and status can be read from its various display screens, including history. No need to connect gauges. Service Inferface Display (excl. cable) VIKING CONTROLLER (factory fitted) for OPA units with economisers/variable capacity fans and/or compressors SMT-920 Viking Controller (Factory fitted only) c/w Outdoor Temperature/Humidity sensor fitted and Room Temp. t/stat supplied loose Optional: Air Quality Sensor (CO2 sensor) 201-000-700 WIFI SERVICE UTILITY (WSU) for use with units fitted with UC6/UC7/UC8 Controllers View a unit's operating data using a WiFi connection and web browser on your mobile device. Data is viewed in real time and can be used to record commissioning status and diagnose operational faults. A running history can also be retrieved. WiFi Service Utility (WSU) Vertical Packaged Units - Ducted Reverse Cycle The VPA is designed to operates in cold South Island conditions; down to 15°C. Features a digital compressor for variable capacity and an EC plug fan with 010V control, low start-up current and on-site adjustable fan inlet/outlet positions. ITEM NO. 520-291-011 MODEL VPA 160RKTGV NOMINAL COOLING kW 2~16.1 NOMINAL HEATING kW 2~16.2 Note: Not a stock item. Includes UC8 and TZT-100 Controller. BMS connectivity via Modbus or RS425. OPTIONS Cabinet colour to suit Different filter types Water heating module Not a Stock Item. Made to order. 1 September 2024 www.temperzone.biz 17 Air Conditioning t CONTENTS Packaged Units - Ducted Water Cooled The low profile HWP Series ducted water cooled packaged air conditioners are ideal for multi-unit installations such as high-rise offices, hotels, apartments and multiple-tenancies. Compact and reliable, these units can be installed above ceiling, or in other concealed spaces, saving valuable floor space and providing conditioned air direct to necessary locations. The units are designed to be used with simple, short duct layouts. HWP 36275 models include high efficiency Thermoshell® technology for improved non-fouling water properties and greater range of water supply temperatures and water flows. HWP 36275 (UC8) models are compatible with the optional SAT-3 or TZT-100 Room Thermostats. UC8 controller based models have the ability to connect to water circulating pumps and flow control valves, so when the unit is cooling a signal will control the valve to obtain an optimum condensing pressure and temperature (and only when needed thereby reducing pump running costs). UC8 also supplies operating conditions and fault codes to TZT-100 or BMS systems. These new systems are MEPS compliant, ie they meet the Minimum Energy Performance Standards set out in AS/NZS 3823.2:2013 and use refrigerant R410A. ITEM NO. 509-036-102 509-048-102 509-059-102 509-079-102 509-098-102 509-118-102 509-142-102 509-172-102 509-192-102 509-255-102 509-275-102 508-591-201 508-631-201 509-036-001 509-048-001 509-059-001 509-079-001 509-098-001 509-118-001 509-142-001 509-172-001 509-192-001 509-255-001 509-275-001 507-581-201 507-621-201 MODEL NOMINAL COOLING kW NOMINAL HEATING kW COOLING WITH ELECTRIC HEAT: HWP 36CEKS (8) 3.5 HWP 48CEKS (8) 4.4 HWP 59CEKS (8) 5.9 HWP 79CEKS (8) 8.1 HWP 98CEKS (8) 9.9 HWP 118CEKT (8) 12.2 HWP 142CEKT (8) 14.7 HWP 172CEKT (8) 18.5 HWP 192CEKT (8) 21.2 HWP 255CEKT (8) * 25.5 HWP 275CEKT (8) * 27.5 HWP 370CEKTN * 36.6 HWP 445CEKTN * 44.5 2.0 2.0 3.0 4.0 4.0 6.0 6.0 9.0 9.0 12.0 12.0 18.0 24.0 REVERSE CYCLE: HWP 36RKS (8) HWP 48RKS (8) HWP 59RKS (8) HWP 79RKS (8) HWP 98RKS (8) HWP 118RKT (8) HWP 142RKT (8) HWP 172RKT (8) HWP 192RKT (8) HWP 255RKT (8) * HWP 275RKT (8) * HWP 370RKTN * HWP 445RKTN * 3.5 4.4 5.9 8.1 9.9 12.2 14.7 18.5 21.2 25.5 27.5 36.7 44.5 3.6 4.6 5.4 8.9 11.1 11.9 14.8 16.4 18.6 23.3 24.5 34.9 42.2 MraEtPeSd Note: * Not a Stock Item; made-to-order. (8) Includes UC8 controller. BMS connectivity via Modbus/RS485 port. Optional SAT-3 Room Thermostat (HWP 36275 only) (refer p.21) Optional TZT-100 Room Thermostat (HWP 36-275) (refer p.21) Above models are complete with spring mounts. Filters (rated EU2/G2) are supplied on HWP 36275 models only; a filter-integrated R/A spigot (Filter Box) is available for all other models. Water hoses included: HWP 36142 models 600 mm lg, HWP 172275 800mm lg. HWP 370/445 units do not include water hoses. HWP 3698 models require single phase power supply; HWP 118+ require three phase. HWP 370/445 models require a 230 volt controller (not available from Temperzone). Opposite Hand versions available. Refer page 30 for Accessories. Nomenclature HWP Suffixes: R Reverse cycle system C Cooling only system E Electric heat K Refrigerant R410A S Single phase power supply T Three phase power supply F Inverter compressor 18 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Packaged Units - Ducted Water Cooled HWPSY Eco models include high efficiency EC motors and therefore have higher EER/COP ratings. Fan speed can be variably controlled directly by a BMS system, via a 010V signal. The low profile HWP Series ducted water cooled packaged air conditioners are ideal for multi-unit installations such as high-rise offices, hotels, apartments and multiple-tenancies. Compact and reliable, these units can be installed above ceiling, or in other concealed spaces, saving valuable floor space and providing conditioned air direct to necessary locations. The units are designed to be used with simple, short duct layouts. HWP 36275 models include high efficiency Thermoshell® technology for improved non-fouling water properties and greater range of water supply temperatures and water flows. HWP 36275 (UC8) models are compatible with the optional SAT-3 or TZT-100 Room Thermostats. UC8 controller based models have the ability to connect to water circulating pumps and flow control valves, so when the unit is cooling a signal will control the valve to obtain an optimum condensing pressure and temperature (and only when needed thereby reducing pump running costs). UC8 also supplies operating conditions and fault codes to TZT-100 or BMS systems. These new systems are MEPS compliant, ie they meet the Minimum Energy Performance Standards set out in AS/NZS 3823.2:2013 and use refrigerant R410A. ITEM NO. 510-036-102 510-048-102 510-059-102 510-079-102 510-098-102 510-118-102 510-142-102 510-172-102 510-192-102 510-255-102 510-275-102 510-036-001 510-048-001 510-059-001 510-079-001 510-098-001 510-118-001 510-142-001 510-172-001 510-192-001 510-255-001 510-275-001 MODEL NOMINAL COOLING kW NOMINAL HEATING kW COOLING WITH ELECTRIC HEAT: HWP 36CEKSY * 3.5 2.0 HWP 48CEKSY * 4.4 2.0 HWP 59CEKSY * 5.9 3.0 HWP 79CEKSY * 8.1 4.0 HWP 98CEKSY * 9.9 4.0 HWP 118CEKTY * 12.2 6.0 HWP 142CEKTY * 14.7 6.0 HWP 172CEKTY * 18.5 9.0 HWP 192CEKTY * 21.2 9.0 HWP 255CEKTY * 25.5 12.0 HWP 275CEKTY * 27.5 12.0 REVERSE CYCLE: HWP 36RKSY 3.5 3.7 HWP 48RKSY 4.4 4.6 HWP 59RKSY 5.9 5.4 HWP 79RKSY 8.1 8.9 HWP 98RKSY 9.9 11.3 HWP 118RKTY 12.2 11.6 HWP 142RKTY 14.7 14.5 HWP 172RKTY 18.5 16.7 HWP 192RKTY 21.2 18.6 HWP 255RKTY * 25.5 23.3 HWP 275RKTY * 27.5 24.5 MraEtPeSd Note: * Not a Stock Item; made-to-order. Includes UC8 controller. BMS connectivity via Modbus/RS485 port. Optional SAT-3 Room Thermostat (refer p.21) Optional TZT-100 Room Thermostat (refer p.21) Above models are complete with spring mounts. Filters (rated EU2/G2) are supplied. Water hoses included: HWP 36142 models 600 mm lg, HWP 172275 800mm lg. HWP 3698 models require single phase power supply; HWP 118+ require three phase. Opposite Hand versions available. Refer page 31 for Accessories. Nomenclature HWP Suffixes: R Reverse cycle system C Cooling only system E Electric heat K Refrigerant R410A S Single phase power supply T Three phase power supply F Inverter compressor Y EC motor 1 September 2024 www.temperzone.biz 19 Air Conditioning t CONTENTS Packaged Units - Ducted Water Cooled - Accessories ITEM NO. MODEL 507-003-009 507-003-010 507-003-011 119-000-049 119-000-050 201-000-146 201-000-074 201-000-075 201-000-077 CONDENSATE LIFT-PUMP KIT: for HWP 3659 for HWP 79275 for HWP 370, 445 FILTERS (washable synthetic fibre EU2/G2): for HWP 370 - 2 required $ 39 ea. for HWP 445 - 2 required $ 41 ea. temperzone SAT-3 ROOM TEMPERATURE CONTROLLER : for HWP 36275 (c/w UC8) Interface cable - 10m (4 core shielded twisted pair) Interface cable - 20m (4 core shielded twisted pair) Interface cable - 30m (4 core shielded twisted pair) Refer page 12 for sensor and other accessories. 201-000-350 201-000-074 201-000-075 201-000-077 temperzone TZT-100 THERMOSTAT : for HWP 36275 (c/w UC8) Interface cable - 10m (4 core shielded twisted pair) Interface cable - 20m (4 core shielded twisted pair) Interface cable - 30m (4 core shielded twisted pair) Refer page 10 for sensor accessories. SPARE PARTS 201-000-023 201-000-412 HWP Protection Board UC8 Controller 24V (Hydronics) 119-000-098 119-000-086 119-000-084 119-000-097 119-000-099 119-000-100 119-000-103 119-000-104 119-000-105 REPLACEMENT FILTER (washable synthetic fibre EU2/G2): for HWP 36, 48 for HWP 59 for HWP 79, 98 for HWP 118 for HWP 142 for HWP 172 for HWP 192 for HWP 255 for HWP 275 - 2 required WARRANTY Standard Warranty as per General Conditions of Sale (page 4) 20 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Packaged Units - Ducted WR3a2ter Cooled CWP Econex model is a closet version of the HWP, but with a variable capacity inverter compressor and built-in water pump. They include high efficiency EC motors. Fan speed can be variably controlled directly by a BMS system, via a 010V signal. ITEM NO. 573-009-002 MODEL NOMINAL COOLING kW NOMINAL HEATING kW REVERSE CYCLE WITH ELECTRIC HEAT: CWP 90RELSFY 4.1~10.0 3.7~8.9 Note: Not a Stock Item; made-to-order. Includes UC8 controller. BMS connectivity via Modbus/RS485 port. Optional TZT-100 Room Thermostat (refer p.29)(Not suitable for SAT-3). Filters (rated EU2/G2) are supplied. Water hoses included: 600 mm lg. Requires single phase power supply. The CWP Series ducted water cooled packaged air conditioners are ideal for multi-unit installations such as high-rise offices, hotels, apartments and multiple-tenancies. The units are designed to be used with simple, short duct layouts. CWP 90 model includes high efficiency Thermoshell® technology with non-fouling water properties and a wide range of water supply temperatures and water flows. Electric elements are included in the air stream as a backup for when supply water temperature is too low. CWP 90 (c/w UC8) can be connected to water circulating pumps and flow control valves, so when the unit is cooling a signal will control the valve to obtain an optimum condensing pressure and temperature (and only when needed thereby reducing pump running costs). UC8 supplies operating conditions and fault codes to TZT-100 or BMS systems. These new systems are MEPS compliant, ie they meet the Minimum Energy Performance Standards set out in AS/NZS 3823.2:2013 and use refrigerant R32 which has a low GWP. MraEtPeSd 1 September 2024 www.temperzone.biz 21 Air Conditioning t CONTENTS Chilled Water Fan Coil Units (IMDL Series) Fan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. temperzone offers an extensive range of ducted fan coil units. A variety of options and accessories are available to meet most air conditioning requirements. Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone IMDL Series fan coil units. New IMDL 'Y' versions include high efficiency EC motors with higher static performance and optional 0-10V speed control. IXDL Series Incorporating multiple EC fans (1 to 5) within each unit, IXDL multi-zone fan coil units allows you to set different temperatures for different rooms within the same building simultaneously. IXDL units are made-to-order. Refer your temperzone representative for more info. or visit www.temperzone.biz ITEM NO. 313-171-001 313-371-001 313-571-001 313-771-001 MODEL IMDL 40-H 3/1 IMDL 60-H 3/1 IMDL 90-H 3/1 IMDL 130-H 3/1 NOMINAL AIR FLOW 205 l/s 335 l/s 480 l/s 650 l/s ELECTRIC HEAT c/w ELECTRIC HEAT (instead of heating coil; w/o SSR) : 313-151-006 IMDL 40-H 4E 205 l/s 1.5 kW 313-351-006 IMDL 60-H 4E 335 l/s 2 kW 313-551-006 IMDL 90-H 4E 480 l/s 3 kW 313-751-006 IMDL 130-H 4E 650 l/s 4 kW c/w EC MOTORS : 313-171-701 313-371-701 313-571-701 313-771-701 IMDL 40Y 3/1 IMDL 60Y 3/1 IMDL 90Y 3/1 IMDL 130Y 3/1 200 l/s 325 l/s 400 l/s 700 l/s c/w EC MOTOR & ELECTRIC HEAT* (instead of heating coil; c/w SSR) : 313-151-806 IMDL 40Y 4E 205 l/s 1.5 kW 313-351-806 IMDL 60Y 4E 335 l/s 2 kW 313-551-806 IMDL 90Y 4E 400 l/s 3 kW 313-751-806 IMDL 130Y 4E 650 l/s 4 kW Note: All of the above units are Stock Items. Units are right handed and fitted with: high (-H) capacity or EC (-Y) motors, return air plenum and filter. * EC motor versions with elec. heat come with SSR using 24V ac control (customer supplied) ACCESSORIES (Supplied separately) 060-000-629 060-000-630 060-000-631 FLEXIBLE HOSES: for Heating coil, all models: 13 FPT (1/2") 600mm lg 3000psi for Cooling coil, IMDL 40/60: 20 FPT (3/4") 600mm lg 1500psi for Cooling coil, IMDL 90/130: 25 FPT (1") 800mm lg 1500psi 313-001-007 313-201-007 313-401-007 313-601-007 MULTI-OUTLET SPIGOT: for IMDL 40 (200 dia. x 2) for IMDL 60 (250 dia. x 2) for IMDL 90 (250 dia. x 3) for IMDL 130 (250 dia. x 4) REPLACEMENT FILTERS (rated EU2) : 119-128-001 for IMDL 40 (545 x 236) 119-129-001 for IMDL 60 (795 x 236) 119-130-001 for IMDL 90 (1045 x 243) 119-131-001 for IMDL 130 (725 x 243) - 2 req'd Note: Fan coil units are also available Made-to-Order with the following options: Standard, Medium or High capacity motors (for non-EC motor versions) 3 row Cooling + 1 row Heating 3 row or 4 row Cooling Only, with or without Electric Heat. Standard Multi-Outlet Spigot Left or Right handed Electric Heat with solid state relay (SSR) for non-EC motor versions 22 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Chilled Water Fan Coil Units (IMD Series) Fan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. temperzone offers an extensive range of ducted fan coil units. A variety of options and accessories are available to meet most air conditioning requirements. Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone IMD Series fan coil units. New IMD 'Y' versions include high efficiency EC motors with higher static performance and optional 0-10V speed control. ITEM NO. 315-311-001 315-381-001 315-451-001 315-521-001 315-591-001 315-661-001 315-731-001 315-311-601-SPE 315-381-601-SPE 315-451-601-SPE 315-521-601-SPE 315-591-601-SPE 315-661-601-SPE 315-731-601-SPE MODEL NOMINAL AIR FLOW IMD 95 4/1 IMD 135 4/1 IMD 170 4/1 IMD 210 4/1 IMD 280 4/1 IMD 420 4/1 * IMD 550 4/1 * 450 l/s 600 l/s 750 l/s 900 l/s 1250 l/s 1800 l/s 2340 l/s EC motor versions: IMD 95Y 4/1 450 l/s IMD 135Y 4/1 600 l/s IMD 170Y 4/1 750 l/s IMD 210Y 4/1 900 l/s IMD 280Y 4/1 1250 l/s IMD 420Y 4/1 1800 l/s IMD 550Y 4/1 2340 l/s Note: * Not a Stock Item. Coils are 4 row cooling + 1 row heating IMD(Y) fan coil units are also available with the following coil configurations: 4 - Four row for cooling or heating 4/E - Four row cooling + electric heat 12 Months Parts & Labour Warranty; Extended Warranty available ACCESSORIES (Supplied separately) 325-121-005 325-231-005 325-271-005 325-311-005 325-351-005 325-431-005 325-591-005 FILTER BOX c/w filter rated EU2/G2 : for IMD 95 for IMD 135 for IMD 170 for IMD 210 for IMD 280 for IMD 420 for IMD 550 307-161-101 307-341-101 060-000-629 060-000-631 060-000-631 060-000-632 060-000-632 SPRING MOUNTING KIT : for IMD 95420 (No.2) for IMD 550 (No.3) FLEXIBLE HOSES: for Heating coil, IMD 95210: 13 FPT (1/2") 600mm lg 3000psi for Cooling coil, IMD 95210 25 FPT (1") 800mm lg 1500psi for Heating coil, IMD 280: 25 FPT (1") 800mm lg 1500psi for Cooling coil, IMD 280550: 32 FPT (1 1/4") 1300mm lg 1000psi for Heating coil, IMD 420, 550: 32 FPT (1 1/4") 1300mm lg 1000psi 1 September 2024 www.temperzone.biz 23 Air Conditioning t CONTENTS Chilled Water Fan Coil Units (GMW Series) GMW fan coil units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. These underceiling models are ideal for fixed ceiling installations, don't take up valuable wall space and are relatively easy to relocate. Suitable for use in department stores, offices, classrooms, institutions, etc. Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone GMW Series fan coil units. ITEM NO. 318-141-001 318-191-001 318-281-001 318-401-001 318-491-001 MODEL GMW 50-H 2/1 GMW 70-H 2/1 GMW 80-H 2/1 GMW 140-H 2/1 GMW 160-H 2/1 NOMINAL AIR FLOW 175 l/s 240 l/s 375 l/s 625 l/s 815 l/s Note: All of the above units are stock items. GMW fan coil units are also available with the following options: Standard or High capacity motors 2 row Cooling + 1 row Heating 3 row Cooling 24 www.temperzone.biz 1 September 2024 t CONTENTS Air Conditioning Chilled Water Air Handling Units (IJD Series) Air Handling units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. temperzone offers an extensive range of belt driven ducted air handling units. A variety of options and accessories are available to meet most air conditioning requirements. Low operating cost, energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of temperzone IJD Series air handling units. temperzone also offers an extensive range of robust custom made air handling units under the Clever brand, up to 23,500 l/s (MC Series). MODEL IJD 370 IJD 450 IJD 620 IJD 950 IJD 1400 IJD 2000 IJD 2400 NOMINAL AIR FLOW 1500 l/s 1800 l/s 2400 l/s 3600 l/s 5500 l/s 7200 l/s 9300 l/s Note: All IJD units are Made-to-Order. Horizontal or vertical supply air versions available. Coil configurations available are: 4 - Four row for cooling or heating 4/1 - Four row cooling / one row heating 4/E - Four row cooling + electric heat 6 - Six row for cooling or heating 6/1 - Six row cooling / one row heating 6/E - Six row cooling + electric heat 1 - One row for heating E - Electric Heat only (no coil) OPTIONS Filters Polyester powder coat finish (Gull Grey). EC Plug fan versions FILTERS (disposable, rated EU4) : 019-400-005 019-400-003 019-400-006 019-400-002 019-400-004 019-400-008 019-400-004 019-400-004 019-400-005 for IJD 370 600 x 500 x 50 - 2 required for IJD 450 625 x 400 x 50 - 3 required for IJD 620 625 x 500 x 50 - 3 required for IJD 950 - 6 required in total 400 x 500 x 50 - 3 required 500 x 500 x 50 - 3 required for IJD 1400 - 8 required in total 450 x 500 x 50 - 4 required 500 x 500 x 50 - 4 required for IJD 2000 500 x 500 x 50 - 12 required for IJD 2400 500 x 600 x 50 - 12 required 1 September 2024 www.temperzone.biz 25 Air Conditioning t CONTENTS Chilled Water Air Handling Units (MT Series) Air Handling units are an integral part of an overall air conditioning system where the energy transfer medium (i.e. chilled or hot water) is circulated by a central plant facility. MT Series units feature EC Plug fans and a light weight aluminium frame, thermal break panels and separable fan coil/plenum sections. A variety of options and accessories are available to meet most air conditioning requirements. Energy efficient fan motors are used in all units. Easy installation and maintenance add to the cost effectiveness of Temperzone MT Series air handling units. Temperzone also offers an extensive range of robust custom made air handling units, up to 23,500 l/s (MC Series). MODEL MT 030 MT 060 MT 120 MT 180 MT 270 MT 360 MT 450 MT 540 NOMINAL AIR FLOW 750 l/s 1 500 l/s 3 000 l/s 5 000 l/s 7 500 l/s 10 000 l/s 12 500 l/s 15 000 l/s Note: All MT units are Made-to-Order on relatively short lead times Horizontal or vertical supply air versions available, as well as LH/RH versions. Coil configurations available are: 2 - Two row heating 4 - Four row for cooling or heating 4/1 - Four row cooling / one row heating 6 - Six row for cooling or heating 6/1 - Six row cooling / one row heating 8 - Eight row cooling OPTIONS Filters: G4 panels, F7 bags or F9 cartridges. Polyester powder coat finish (Titania). Return air/outside air mixing dampers. Magnahelic guage, internal lighting, inspection window. MC Series custom built range. 26 www.temperzone.biz 1 September 2024 t CONTENTS WaAteirr CCoonnddiittiioning Heat Pump Water Heaters MWS Potable units are Single Pass systems providing 62°C hot water. Use R32 low GWP refrigerant. An in-built BDLC pump is included. Liquid injection compressor technology is standard for improved performance at low ambient conditions. Rating conditions: 7/6 °C db/wb outdoor ambient; EWT 30°C; LWT 45°C MWH Space Heating units include variable capacity inverter compressors enabling close temperature control. Use R32 low GWP refrigerant. A pump is optional. EVI version (V) is recommended for improved performance at low ambient conditions. Rating conditions: 7/6 °C db/wb outdoor ambient; EWT 30°C; LWT 45°C MWU Underfloor units include a variable capacity inverter compressor enabling close temperature control. Inverters provide additional economy at part load. Uses R410A refrigerant. Includes integrated BDLC pump (8m head). Rating conditions: 7/6 °C db/wb outdoor ambient; EWT 25°C; LWT 35°C MWP Pool units include a titanium Thermoshell®. Use R410A refrigerant. TZT100 Controller supplied. A pump is not included. Rating conditions: 25/18 °C db/wb outdoor ambient; EWT 25°C; LWT 28°C Application Optimised Heat Pumps Features: - Designed and manufactured for reliability and durability by Temperzone in NZ. - Highly efficient, cost effective integrated water heating systems - Fouling resistant ThermoShell® heat-exchanger - In-line inverter systems for space heating and cooling for maximum energy savings - Elimination of intermediate buffer tanks - Powerful yet quiet, compact design - Integrated 'turnkey' controls for suitable applications (eg LAT Control with MWH) - Integrated BLDC (variable speed) pump on some models - Local support and commissioning - BMS / Modbus connectivity As all systems are application optimised. Contact temperzone for info on how to apply these models. ITEM NO. 503-025-005 503-050-005 503-100-005 DESCRIPTION NOMINAL HEATING kW CAPACITY RANGE kW POTABLE MODELS (SINGLE PASS): Three Phase: MWS 250LT 20.0 MWS 500LTM 40.0 MWS 1000LTM 74.0 503-090-501 503-090-511 503-090-505 503-090-515 503-200-505 503-200-515 SPACE HEATING MODELS: Three Phase: MWH 900LTM-PC 77.5 MWH 900LTM-C (w/o pump) MWH 900LTM-PCV 89.3 MWH 900LTM-CV (w/o pump) MWH 2000LTM-CE (wop) 140.0 MWH 2000LTM-CEV (wop) 154.3 22.3 ~ 91.9 21 ~ 105 14 ~ 205 14 ~ 224 502-018-101 502-025-101 502-045-101 349-000-975 UNDERFLOOR MODELS: Single Phase: MWU 180KS 15.8 Three Phase: MWU 250KT 19.5 MWU 450KT 37.0 Accessories: Expansion Tank, Statico SD 8.3, 8L 3.8 ~ 19.5 4.7 ~ 19.5 8.9 ~ 48.5 Suffix Nomenclature K Refrigerant R410A L Refrigerant R32 S Single phase power supply T Three phase power supply M Multiple compressors P Internal Pump C Advanced Controller (PLC) E EC Condenser fans V Electronic Vapour Injection (EVI) 1 September 2024 502-023-201 502-025-201 502-040-201 060-000-437 POOL HEATING MODELS: Single Phase: MWP 230KS 26.0 Three Phase: MWP 250KT 27.5 MWP 400KT 42.5 ACCESSORY (All models): Drain Adaptor Kit (25OD/21ID) Note Commissioning by Temperzone. Complete our Sales Enquiry form prior to ordering. WARRANTY 2 years Parts & Labour. Also available: pumps, expansion & storage tanks, auto-fill kit, water flow valves. www.temperzone.biz 27 Air Distribution t CONTENTS Radial Swirl Diffusers ITEM NO. 122-600-001 122-935-150 122-935-200 122-935-250 122-935-300 122-600-002 122-950-250 122-950-300 122-950-350 122-950-400 122-600-011 122-600-012 DESCRIPTION SMARTEMP® Range (Fixed Helical): HSC-FD-DN355-S595 355 dia. White 595 mm Square, lay-in half tile, excl. plenum Side entry plenum, Ø150 spigot * Side entry plenum, Ø200 spigot Side entry plenum, Ø250 spigot Side entry plenum, Ø300 spigot HSC-FD-DN500-S595 500 dia. White 595 mm Square, lay-in half tile, excl. plenum Side entry plenum, Ø250 spigot Side entry plenum, Ø300 spigot Side entry plenum, Ø350 spigot Side entry plenum, Ø400 spigot * HSC-FD-DN355-C500 355 dia. White Round, 500 mm OD, excl. plenum HSC-FD-DN500-C710 500 dia. White Round, 710 mm OD, excl. plenum Note: * Made-to-order Collars, 2-way and 3-way inserts; made-to-order. Ask your temperzone representative about other SmarTemp® products available. ISF-AD Floor Swirl Outlet CNW-AD Circular Nozzle Outlet PMW-AD Perforated Mainstream Diffuser LMC-AD Linear Mainstream Ceiling Diffuser 28 www.temperzone.biz 1 September 2024 t CONTENTS Air Distribution RPD - Round Plastic Ceiling Diffusers ITEM NO. 133-000-150 133-000-200 133-000-250 DESCRIPTION Round Plastic Diffuser Round Plastic Diffuser Round Plastic Diffuser SIZE (mm) 150 dia. 200 dia. 250 dia. Grilles ITEM NO. DESCRIPTION SIZE (mm) 121-106-150 121-106-200 121-106-250 121-106-300 121-106-400 121-106-550 121-201-300 121-201-400 121-201-512 121-900-450 119-088-001 119-090-001 119-087-001 119-089-001 EGC-5 150 x 150 EGC-5 200 x 200 EGC-5 250 x 250 EGC-5 300 x 300 EGC-5 400 x 400 EGC-5 lay-in 550 x 550 EGC-5 / HF * 300 x 300 EGC-5 / HF * 400 x 400 EGC-5 / HF * lay-in 512 x 512 EGC-5 / HF 900 x 450 Filter only 300 x 300 Filter only 400 x 400 Filter only 512 x 512 Filter only 850 x 400 * HF - Hinged Frame, including filter. COLOUR White White White White White White White White White White Adaptors for Grilles ITEM NO. MODEL SIZE (mm) 122-030-060 122-030-061 122-030-073 122-033-005 121-400-040 121-400-011 121-400-001 121-400-012 121-400-002 121-900-451 A15 A20 A30 * A33 * A40 A51a A51 A55a A55 A90 150 sq. to 150 dia. 200 sq. to 150/200 dia. 300 sq. to 200/250 dia. 300 sq. to 300 dia. 400 sq. to 300/350 dia. 512 sq. to 250/300 dia. 512 sq. to 350/400 dia. 550 sq. to 250/300 dia. 550 sq. to 350/400 dia. 900 x 450. to 2 x 350 dia. All adaptors are made of black plastic, except A90 which is metal. 1 September 2024 www.temperzone.biz 29 Air Distribution Flexiduct t CONTENTS ITEM NO. DESCRIPTION SIZE LENGTH 128-000-021 128-000-022 128-000-023 128-000-024 Flexiduct - Nude Flexiduct - Nude Flexiduct - Nude Flexiduct - Nude 150 mm dia. 3 m 200 mm dia. 3 m 250 mm dia. 3 m 300 mm dia. 3 m 128-000-121 128-000-122 128-000-123 128-000-124 128-000-125 128-000-126 Flexiduct - Insulated 150 mm dia. 3 m Flexiduct - Insulated 200 mm dia. 3 m Flexiduct - Insulated 250 mm dia. 3 m Flexiduct - Insulated 300 mm dia. 3 m Flexiduct - Insulated 350 mm dia. 3 m Flexiduct - Insulated 400 mm dia. 3 m 128-000-222 128-000-223 128-000-224 128-000-225 128-000-226 Flexiduct - Insulated 200 mm dia. 6 m Flexiduct - Insulated 250 mm dia. 6 m Flexiduct - Insulated 300 mm dia. 6 m Flexiduct - Insulated 350 mm dia. 6 m Flexiduct - Insulated 400 mm dia. 6 m Note: Above sizes are all stock items. Flexiduct has been tested at a NATA/Telarc certified laboratory to AS 4254 and complies with NZ Building Code - Fire Safety Amendment Regulations (April 2013). Duct Tape Duct Joiners ITEM NO. 127-000-040 127-000-042 DESCRIPTION Duct Sealing Tape - 48 mm x 30 m - Plastic Duct Sealing Tape - 48 mm x 30 m - Silver Polyprop. ITEM NO. 127-000-001 127-000-002 127-000-003 127-000-004 127-000-005 DESCRIPTION Duct Joiner Duct Joiner Duct Joiner Duct Joiner Duct Joiner Galvanised steel construction. SIZE (mm) 150 dia. 200 dia. 250 dia. 300 dia. 350 dia. 30 www.temperzone.biz 1 September 2024 t CONTENTS Air Distribution Air Regulating Damper (TRD Series) Dimensions Width: 3002000 mm Height: 200 1200 mm Note: All dampers are opposed blade rotation only. One axle and actuator mounting plate per damper is included. Mill finish only. Not a Stock Item. Manufactured to order. OPTIONS Electric actuators Multiple section dampers to cover larger sizes than tabled above Polyester powder coat or anodised finish Locking Quadrant (factory fitted) 1 September 2024 www.temperzone.biz 31 Ventilation In-Line Centrifugal Fans ITEM NO. 084-002-001 084-005-001 084-007-001 084-009-001 084-010-001 MODEL AXC 100B AXC 150A AXC 200A AXC 250 AXC 315A DIA. (mm) 100 150 200 250 315 SPEED R.P.M. 2400 2500 2550 2650 2650 ITEM NO. 084-005-002 084-007-002 084-009-002 084-010-002 DESCRIPTION Duct Clamp " " " " " " DIA. (mm) 150 200 250 315 t CONTENTS 084-010-003 AXC 315300 adaptor 315 084-001-005 084-001-006 AXC Electronic Controller R15 AXC Electronic Controller - flush box 32 www.temperzone.biz 1 September 2024 t CONTENTS AOirthCeornPdritoiodnuicntgs Circulating Water Pumps HVAC Application: Hot-water heating systems of all kinds, air-conditioning applications, industrial circulation systems. Glandless Pumps. Powerful, energy-efficient, easy-maintenance, reliable ZRS & Star suited to residential and light commercial applications; sanitary circulators; bronze ITEM NO. DESCRIPTION 070-000-484 ZRS (Sanitary) ZRS 15/6 Ku P (Replaces previous model Intec Z) ZRS Stratos PICO-Z Varios The most compatible replacement solution for all applications thanks to it's revolutionary design and the Sync function, which allows the installer to duplicate the previous pump settings into the new pump Varios 070-001-033 070-001-034 Stratos PICO-Z (Sanitary) Stratos PICO-Z 25/1-6 Stratos PICO-Z 20/1-6 (Replaces previous model Star Z) Varios PICO 070-001-005 070-001-004 070-001-037 Varios PICO 15/1-7 Varios PICO 25/1-7 Varios PICO 25/1-7-130 Other sizes available 349-000-832 349-000-825 349-000-831 349-000-829 349-000-833 349-000-827 349-000-830 Unions: 20mm Steel Unions 25mm Cast Iron Unions 32mm Cast Iron Unions 15mm Bronze Unions 20mm Bronze Unions 25mm Bronze Unions 32mm Bronze Unions WARRANTY 2 Years Parts only. Visit www.wilo.com for Wilo pump replacement guide here or contact Temperzone for assistance. 1 September 2024 www.temperzone.biz 33 AOitrhCeroPndroitdiouncitnsg Circulating Water Pumps HVAC Application: Hot-water heating systems of all kinds, air-conditioning applications, industrial circulation systems. Glandless Pumps. Powerful, energy-efficient, easy-maintenance, reliable Yonos particularly suited to radiators or underfloor heating ITEM NO. 070-001-006 070-001-009 070-001-007 070-001-010 070-001-011 070-001-032 070-001-604 070-001-605 070-001-606 070-001-607 070-001-608 070-001-609 070-001-610 070-001-611 070-001-612 070-001-613 DESCRIPTION Yonos MAXO Yonos MAXO 25/0.5-7 Yonos MAXO 25/0.5-10 Yonos MAXO 25/0.5-12 Yonos MAXO 30/0.5-7 Yonos MAXO 30/0.5-10 Yonos MAXO 30/0.5-12 Yonos MAXO 40/0.5-8 PN6/10 Yonos MAXO 40/0.5-12 PN6/10 Yonos MAXO 40/0.5-16 PN6/10 Yonos MAXO 50/0.5-8 PN6/10 Yonos MAXO 50/0.5-12 PN6/10 Yonos MAXO 65/0.5-9 PN6/10 Yonos MAXO 65/0.5-12 PN6/10 Yonos MAXO 80/0.5-6 PN10 Yonos MAXO 80/0.5-12 PN10 Yonos MAXO 100/0.5-12 PN10 070-001-043 070-001-042 070-001-003 070-001-002 Yonos MAXO-Z (Sanitary) Yonos MAXO-Z 25/0.5-7 PN10 Yonos MAXO-Z 25/0.5-10 PN10 Yonos MAXO-Z 30/0.5-7 PN10 Yonos MAXO-Z 30/0.5-12 PN10 INFO LINK * 2120639 2120640 2120641 2120642 2120643 2120644 2120646 2120647 2120648 2120649 2120651 2120653 2120654 2120657 2120659 2120661 2175538 2175539 2175540 2175541 TOP-Z hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Bronze housing. 070-001-082 070-001-080 070-001-084 070-001-086 070-001-087 070-001-088 TOP-Z (Sanitary) TOP-Z 25/6 (3~) PN10 TOP-Z 25/10 (3~) PN10 TOP-Z 30/7 (3~) PN10 TOP-Z 30/10 (3~) PN6/10 TOP-Z 40/7 (3~) PN6/10 TOP-Z 50/7 (3~) PN6/10 2045522 2175509 2048341 2175512 2175516 2175522 * Click Article number for detailed product info from Wilo.com WARRANTY 2 Years Parts only. t CONTENTS Visit www.wilo.com for Wilo pump replacement guide here or contact Temperzone for assistance. 34 www.temperzone.biz 1 September 2024 t CONTENTS AOirthCeornPdritoiodnuicntgs Circulating Water Pumps TOP-S hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems. Cast Iron housing. ITEM NO. DESCRIPTION INFO LINK ** TOP-S * 070-001-113 TOP-S 25/7 (3~) PN10 2048321 070-001-114 TOP-S 25/10 (3~) PN10 2165521 070-001-115 TOP-S 25/13 (1~) PN10 2084440 070-001-116 TOP-S 25/13 (3~) PN10 2084441 070-001-118 TOP-S 30/4 (3~) PN10 2084012 070-001-120 TOP-S 30/7 (3~) PN10 070-001-121 TOP-S 30/10 (3~) PN10 070-001-122 TOP-S 40/4 (1~) PN6/10 070-001-123 TOP-S 40/4 (3~) PN6/10 070-001-125 TOP-S 40/7 (1~) PN6/10 070-001-126 TOP-S 40/7 (3~) PN6/10 070-001-127 TOP-S 40/10 (1~) PN6/10 070-001-136 TOP-S 50/10 (3~) PN6/10 070-001-137 TOP-S 50/15 (3~) PN6/10 070-001-138 TOP-S 65/7 (1~) PN6/10 070-001-139 TOP-S 65/7 (3~) PN6/10 070-001-140 TOP-S 65/10 (3~) PN6/10 070-001-141 TOP-S 65/13 (3~) PN6/10 070-001-142 TOP-S 65/15 (3~) PN6/10 070-001-144 TOP-S 80/7 (3~) PN6 070-001-145 TOP-S 80/10 (3~) PN6 070-001-146 TOP-S 80/15 (3~) PN6 070-001-147 TOP-S 100/10 (3~) PN6 * Check with availability with Temperzone Sales prior to ordering. ** Click Article number for detailed product info from Wilo.co WARRANTY 2 Years Parts only. Visit www.wilo.com for Wilo pump replacement guide here or contact Temperzone for assistance. 1 September 2024 www.temperzone.biz 35 AOitrhCeroPndroitdiouncitnsg t CONTENTS Pre-Insulated Pipe Application: Thermal energy distribution, domestic hot and cold water piping; potable or geothermal. Flexible and easy to install. Safest choice with homogeneous welding, one material, for increased reliability. Electro-fusion weldable fittings or compression joiner system. Range of connector fittings ITEM NO. DESCRIPTION MIN. BEND RADIUS 029-000-446 029-000-447 029-000-448 029-000-449 029-000-453 029-000-450 029-000-463 Flexalen 600 pipe single (casing/insert): Single 125/63 OD Single 160/75 OD Single 160/90 OD Single 200/110 OD End Cap - rubber 125/3275 OD End Cap - rubber 160/5090 OD End Cap - rubber 200/110 OD 0.8m 0.8m 1.0m 1.25m 029-000-464 029-000-465 029-000-466 029-000-467 029-000-451 029-000-452 029-000-454 029-000-455 Flexalen 600 pipe twin (casing/insert): Twin 125/2x25 OD Twin 125/2x32 OD Twin 160/2x40 OD Twin 160/2x50 OD Twin 200/2x63 OD End Cap - rubber 125 / 2x25 OD or 2x32 OD End Cap - rubber 160 / 2x40 or 2x50 OD End Cap - rubber 200 / 2x63 OD 0.6m 0.6m 0.8m 0.8m 1.25m 060-000-508 060-000-509 060-000-510 060-000-511 060-000-512 060-000-513 060-000-514 060-000-515 Electro-fusion Joiner Parts: Coupler OD025 Coupler OD032 Coupler OD040 Coupler OD050 Coupler OD063 Coupler OD075 Coupler OD090 Coupler OD110 029-000-406 029-000-407 029-000-408 029-000-409 029-000-410 029-000-411 029-000-412 Elbow OD025 90° Elbow OD032 90° Elbow OD040 90° Elbow OD050 90° Elbow OD063 90° Elbow OD075 90° Elbow OD090 90° 36 www.temperzone.biz 1 September 2024 t CONTENTS AOirtCheornPdritoiodnuicntgs Pre-Insulated Pipe (cont'd) ITEM NO. DESCRIPTION 1 September 2024 029-000-413 029-000-414 029-000-415 029-000-416 029-000-417 029-000-418 029-000-419 029-000-420 Electro-fusion Joiner Parts (cont'd): Elbow OD110 45° Elbow OD110 90° Elbow OD 32 45° Elbow OD 40 45° Elbow OD 50 45° Elbow OD 63 45° Elbow OD 75 45° Elbow OD 90 45° 029-000-421 029-000-422 029-000-424 029-000-425 029-000-426 029-000-427 029-000-428 T 90° Equal OD 32 T 90° Equal OD 40 T 90° Equal OD 50 T 90° Equal OD 63 T 90° Equal OD 75 T 90° Equal OD 90 T 90° Equal OD 110 029-000-430 029-000-431 029-000-432 029-000-433 029-000-434 029-000-435 029-000-436 029-000-437 029-000-438 029-000-441 029-000-442 029-000-443 Reducer OD 32 > OD 25 Reducer OD 40 > OD 32 Reducer OD 50 > OD 40 Reducer OD 63 > OD 40 Reducer OD 63 > OD 32 Reducer OD 63 > OD 50 Reducer OD 75 > OD 63 Reducer OD 90 > OD 63 Reducer OD 90 > OD 75 Reducer OD 110 > OD 63 Reducer OD 110 > OD 75 Reducer OD 110 > OD 90 060-000-519 060-000-504 060-000-521 060-000-522 060-000-505 060-000-524 060-000-525 060-000-506 060-000-527 63 mm: Flange Adaptor* GF-BUNDBU63 Flange Backing Ring GP-LOSF63-10 Flange Seal GF-BUNDBU63 75 mm: Flange Adaptor* GF-BUNDBU75 Flange Backing Ring GP-LOSF75-10 Flange Seal GF-BUNDBU75 90 mm: Flange Adaptor* GF-BUNDBU90 Flange Backing Ring GP-LOSF90-10 Flange Seal GF-BUNDBU90 * To be used in conjunction with an Electrofusion Joiner Part www.temperzone.biz 37 OAitrhCeroPnrdoitdiouncitnsg t CONTENTS Pre-Insulated Pipe (cont'd) ITEM NO. DESCRIPTION 060-000-528 060-000-507 060-000-530 Electro-fusion Joiner Parts (cont'd): 110 mm: Flange Adaptor* GF-BUNDBU110 Flange Backing Ring GP-LOSF110-10 Flange Seal GF-BUNDBU110 * To be used in conjunction with an Electrofusion Joiner Part 029-000-400 029-000-401 029-000-402 029-000-403 029-000-404 Compression Fittings: BCA OD 25 Male 2.3mm (C) BCA OD 32 Male 3.0mm BCA OD 40 Male 3.7mm BCA OD 50 Male 4.6mm BCA OD 63 Male 5.8mm 38 www.temperzone.biz 1 September 2024 t CONTENTS AOirthCeornPdriotidouncintsg Radiators (Econorad®) High performance 'custom made' radiators are constructed from flat rectangular tubing which has low water resistance providing quick and uniform heat up. Output 150W up to 10,850W. Thermostatic Radiator Valves by Heimeier®. More info. click here. Boilers by De Dietrich® & Gassero® Gas Condensing and electric models floor standing and wall hung types Natural gas, oil or electric. More info. click here. Air Conditioning Units (Split Systems) An extensive range of residential and commercial product types available including: wall mounts, floor mounts, ducted, casssettes, underceiling, multi-zone and VRF. A separate product catalogue is available on request, or visit www.hitachiaircon.co.nz 1 September 2024 www.temperzone.biz 39 REGISTERED AS/NZS ISO 9001: 2015 SUPPLIER Materials and specifications are subject to change without notice due to the manufacturer's ongoing research and development programme. © temperzone ltd 2024 New ZealandAdobe PDF Library 17.0 Adobe InDesign 19.5 (Macintosh)
![]() |
Temperzone Product Overview - Air Conditioning, Ventilation, and Heating Solutions A comprehensive overview of Temperzone's product range, including air conditioning, water conditioning, air distribution, and ventilation & heating systems. Features detailed product specifications, item numbers, and application information. |
![]() |
Temperzone Product Overview - HVAC Solutions for Air, Water, Ventilation & Heating Explore Temperzone's comprehensive range of HVAC products, including advanced air conditioning systems, efficient water heaters, air distribution components, ventilation solutions, and more. Featuring Hitachi Cooling & Heating products. |
![]() |
Temperzone Ducted Packaged Units OPA 1410/1710/2110 Econex Series R32 Technical Data Comprehensive technical data, specifications, performance charts, and features for Temperzone's OPA 1410, 1710, and 2110 Econex Series R32 ducted packaged rooftop air conditioning units, designed for commercial environments. |
![]() |
Temperzone Water Cooled Packaged Units: Energy Efficient HVAC Solutions Discover Temperzone's advanced Water Cooled Packaged Units, featuring energy-efficient ThermoShell® technology for superior performance and cost savings. Explore HWP and CWP series for flexible, reliable climate control solutions. |
![]() |
Temperzone OPA 2110 Econex R32 Ducted Packaged Units Part Load Data Detailed performance and part load data for the Temperzone OPA 2110 Econex R32 ducted packaged air conditioning unit, including cooling and heating capacities. |
![]() |
Temperzone Water Cooled Packaged Units: Energy Efficient HVAC Solutions Discover Temperzone's advanced Water Cooled Packaged Units (HWP and CWP series). Featuring innovative ThermoShell® technology, these units offer superior energy efficiency, design flexibility, and cost savings for commercial and high-rise building applications. |
![]() |
Temperzone OPA 211 Econex (Pro) R32 Ducted Packaged Units Part Load Data Detailed performance data for Temperzone's OPA 211 Econex (Pro) R32 ducted packaged units, including cooling and heating capacities under various operating conditions, and indoor air flow correction factors. |
![]() |
Temperzone HWP-K Series: Ducted Water Cooled R410A Packaged Air Conditioners Product Review An overview of the Temperzone HWP-K Series ducted, water-cooled, R410A packaged air conditioners, detailing features, specifications, and application considerations for commercial and industrial HVAC systems. |