R. STAHL 8581/31-407 125 A Wall Socket
Installation Materials
Product Overview
The R. STAHL 8581/31 series wall sockets, specifically the 8581/31-407 model, are designed for Zone 1/21 hazardous areas, offering a full 125 A AC-3 switching capacity. These sockets feature a high IP66 protection rating against dust and water ingress, ensuring maximum protection in all application positions. Self-cleaning lamella contacts guarantee optimal electrical contact, and the plugs can be easily connected and disconnected in the zero position. The switch-disconnector includes a mechanical locking mechanism with a lockable lever in the 0 and 1 positions for enhanced safety.
Key features include a reliable switch-disconnector with a lockable lever and clear position indication, an integrated auxiliary contact for control and signaling (expandable with plug-in auxiliary contacts), a wide operating temperature range, high mechanical resistance to impact and shock, and perfect protection against liquid and dust penetration. 3D data is available for download.
Technical Specifications
Explosion Protection
Field of Application | European Union (ATEX), IECEx, China (CQST) |
---|---|
Field of Application Note | Other country codes available upon request |
Application Domain (Zones) | 1, 2, 21, 22 |
IECEx Gas Certificate | IECEx PTB 06.0034 |
IECEx Gas Explosion Protection | Ex db eb IIC T6... T5 Gb |
IECEx Dust Certificate | IECEx PTB 06.0034 |
IECEx Dust Explosion Protection | Ex tb IIIC T65 °C / T85 °C Db |
ATEX Gas Certificate | PTB 01 ATEX 1161 |
ATEX Gas Explosion Protection | II 2 G Ex db eb IIC T6 ... T5 Gb |
ATEX Dust Certificate | PTB 01 ATEX 1161 |
ATEX Dust Explosion Protection | II 2 D Ex tb IIIC T65 °C / T85 °C Db |
Certificates | ATEX (PTB), Brazil (ULB), China (CQST), Korea (KGS), IECEx (PTB), Taiwan (ITRI), ATEX (EGK), China (CCC) |
Conformity Certificate | ATEX (EGK), China (CCC) |
Electrical Characteristics
Rated Operational Voltage AC | 480 ... 500 V AC |
---|---|
Rated Operational Current | max. 125 A |
Electrical Service Life | > 2x10⁴ switching cycles |
Mechanical Service Life | > 2x10⁵ switching cycles |
Voltage Type | Low voltage |
Rated Breaking Capacity (AC-3) | 690 V, 125 A |
Auxiliary Contacts | 2 (1 NO + 1 NC) |
Frequency Range | 50 / 60 Hz |
Power Fuse with Thermal Protection | 160 A gG |
Power Fuse without Thermal Protection | 125 A gG |
Ambient Conditions
Ambient Temperature | -45 °C ... 60 °C (-49 °F ... +140 °F) |
---|
Service Temperature Ranges / Connection Cross-Section Assignment
Temperature Class | Rated Service Current | Connection Cross-Section Assignment (Plug) | Connection Cross-Section Assignment (Socket) |
---|---|---|---|
T6 | ≤ +45 °C, 125 A | ≥ 70 mm² | ≥ 50 mm² |
T5 | ≤ +55 °C, 110 A | ||
≤ +60 °C, 100 A | 50 ... 70 mm² | 35 mm² | |
≤ +45 °C, 125 A | |||
≤ +55 °C, 110 A | |||
≤ +40 °C, 100 A | 50 ... 70 mm² | 35 mm² | |
≤ +45 °C, 115 A | |||
≤ +40 °C, 100 A | 50 ... 70 mm² | 35 mm² |
Note: For temperatures ≤ +40 °C, use cables resistant to heat ≥ 85 °C, e.g., type NSSHÖU.
Mechanical Characteristics
Degree of Protection IP (IEC 60529) | IP66 |
---|---|
Degree of Protection IP (IEC 60079) | IP66 |
Housing Material | Polyester, glass fiber reinforced |
Silicone-Free | No |
Multi-wire Connection | 2 x 35 mm² ... 2 x 50 mm² |
Multi-wire Connection AWG | 2 x AWG 2 ... 2 x AWG 1/0 |
Fine-wire Connection | 1 x 50 mm² ... 1 x 150 mm² |
Fine-wire Connection AWG | 1 x AWG 1/0 ... 1 x AWG 300 kcmil |
Multi-wire Connection | 1 x 35 mm² ... 1 x 150 mm² |
Multi-wire Connection AWG | 1 x AWG 2 ... 1 x AWG 300 kcmil |
Width | 270 mm (10.63 in) |
Height | 296 mm (11.65 in) |
Length | 563 mm (22.18 in) |
Impact Resistance (IEC 60079) | 7 J |
Impact Resistance (IEC 62262) | IK10 |
Components
Cable Entries
- Entry 1 Model: 8161/7-M63-4828-LT
- Entry 1 Type: Polyamide cable gland
- Introduction 1: M63 x 1.5
- Clamping Range Introduction 1: 28 - 48 mm (1.1 - 1.89 in)
- Metal Cable Entry Possible 1: No
- Entry 2 Model: 8290/3-M63
- Entry 2 Type: Polyamide blanking plug
- Introduction 2: M63 x 1.5
- Metal Cable Entry Possible 2: No
- Entry 3 Model: 8290/3-M25
- Entry 3 Type: Polyamide blanking plug
- Introduction 3: M25
- Metal Cable Entry Possible 3: No
Accessories
Accessory | Part No. |
---|---|
Blanking Plug 8290/3-M25, Plastic, M25 x 1.5, Cable Outer Diameter 7 – 17 mm, Lot Size 50 pieces | 143524 |
Blanking Plug 8290/3-M63, Plastic, M63 x 1.5, Cable Outer Diameter 28 – 48 mm, Lot Size 1 piece | 143548 |
Auxiliary Contacts
Type | Part No. |
---|---|
2 NO (8080/1-3), 250 V AC/DC, max. 6 A, 1.5 - 2.5 mm² solid/fine-wired. Switching function depends on mounting location. Synchronized left and right. | 168356 |
1 NC + 1 NO (8080/1-1), 250 V AC/DC, max. 6 A, 1.5 - 2.5 mm² solid/fine-wired. Switching function depends on installation bay. Left: delayed (ON), advanced (OFF). Right: synchronized. | 168351 |
2 NO (8080/1-4), 250 V AC/DC, max. 6 A, 1.5 - 2.5 mm² solid/fine-wired. Switching function depends on mounting location. Synchronized left and right. | 168353 |
Other Components
Component | Part No. |
---|---|
Plug 8581/12-407, 4-pole, 480 ... 500 V AC, 50 / 60 Hz, 125 A | 277865 |
Switch Insert 8549/1-31L, Power/Motor Switch | 168776 |
Ex i Blanking Plug for auxiliary contacts used in Ex i circuits | 168855 |
Plastic Cable Gland 8161/7-M25-1707, Ex e, Plastic, M25 x 1.5, Cable Outer Diameter 7 – 17 mm, Lot Size 50 pieces | 239157 |
Plastic Cable Gland 8161/7-M63-4828, Ex e, Plastic, M63 x 1.5, Cable Outer Diameter 28 – 48 mm, Lot Size 1 piece | 239161 |
Spare Parts
Item | Description | Part No. |
---|---|---|
Key for Auxiliary Contact | For removing mounted auxiliary contacts | 201909 |
Repair Kit for 8581 Series Sockets | Repair Kit 8581 Hinged Cover, Black | 275511 |
Technical Drawings
Dimensional drawings are provided for the wall socket, showing overall dimensions in mm and inches. These drawings are subject to modification.
Note: Figures are for illustrative purposes only.