1. BEFORE YOU BEGIN
1.1 PRODUCT DESCRIPTION
Our powerful portable air conditioners are great cooling solutions for single rooms, creating a comfortable atmosphere in your space. It also has ventilation and dehumidifying function for circulating air and removal of moisture. They're self-contained systems that do not require any permanent installation, allowing you to move to the space in which it is most needed. They're commonly used in kitchen, temporary-resided, computer rooms, garages, and many other places where installation of Air-conditioner Outdoor Unit is limited.
2. FOR YOUR SAFETY
Your safety is the most important thing we are concerned about!
WARNING: Please read this manual carefully and fully understand before operating your appliance.
2.1 OPERATIONAL PRECAUTIONS
WARNING - to reduce the risk of fire, electric shock or injury to persons or property:
- Please let the portable air conditioner stand upright for at least 24 hours before plugging in.
- If the supply cord is damaged, it must be replaced by the manufacturer or similarly qualified persons in order to avoid a hazard.
- The appliance shall be disconnected from its power source during service.
- Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
- Always use a power outlet that is grounded.
- Unplug the power cord when cleaning or when not in use.
3. PRODUCT OVERVIEW
3.1 PRODUCT DIAGRAM
A diagram shows the portable air conditioner with numbered parts: 1. Control panel, 2. Air outlet with adjustable louver, 3. Front Panel, 4. Air inlet with air filter, 5. Recessed handle, 6. Air Exhaust, 7. Drain opening with sealing plug, 8. Caster.
Note: The appearance is only for reference. Please see the real product for detailed information.
3.2 FEATURES
- High capacity in a compact size with cooling, dehumidifying, heating and fan function.
- Temperature setting and display
- LED digital display
- Electronic control with built-in timer, sleep mode
- Self-evaporating system for better efficiency
- Auto shut off when tank full
- Automatic restart in the event of power outage
- Auto defrosting function at low ambient temperatures
- Remote control
- 3- speed fan
- Casters for easy mobility
4. INSTALLATION
4.1 UNPACKING
- Unpack the carton and take the appliance and accessories out.
- Check the device after unpacking for any damage or scratches on it.
- Accessories: 1. Exhaust hose, 2. Hose connector, 3. Window kit adapter, 4. Remote control, 5. Window kit, 6. Drainage pipe
4.2 Choose your location
- If tipped more than 45°, allow the unit to set upright for at least 24 hours before starting up.
- Place the unit on a firm, level surface in an area with at least 19.5" (50cm) of free space around it to allow for proper air circulation.
- Do not operate in close proximity to walls, curtains, or other objects that may block air inlet and outlet. Keep the air inlet and outlet free of obstacles.
- Never install the unit where it could be subject to: Heat sources such as radiators, heat registers, stoves or other products that produce heat; Direct sunlight; Mechanical vibration or shock; Excessive dust; Lack of ventilation, such as cabinet or bookcase; Uneven surface.
4.3 ATTACH THE EXHAUST HOSE
The air conditioner requires being vented outside so that the exhaust air can escape the room which coming from the appliance contains waste heat and moisture. Do not replace or extend exhaust hose which will result in decreased efficiency, even worse shut down the unit due to low backpressure.
- Step 1: Connect the hose connector to one end of the exhaust hose.
- Step 2: Connect the windows kit adapter to the other end of the exhaust hose.
- Step 3: Extend the adjustable window kit the length of your window. Connect the exhaust hose to the window kit.
- Step 4: Close your window to secure the kit in place. It needs to hold the windows kit firmly in place, secure the window kit with duct tape if required. It is recommended that the gap between the adapter and the sides of the window should be sealed off for maximum efficiency.
- Step 5: Attach the hose connector to the exhaust air outlet of unit.
- Step 6: Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet.
- Step 7: Adjust the louver at the air outlet, and then switch on the unit.
5. OPERATION
5.1 CONTROL PANEL AND DISPLAY
A diagram shows the control panel with numbered buttons: 1. POWER, 2. MODE, 3. MODE Indicator, 4. SLEEP, 5. DOWN, 6. SWING, 7. SPEED, 8. Indicators, 9. TIMER, 10. UP, 11. Digital Display.
5.2 FUNCTION KEYS AND INDICATORS
- 1. POWER: Press to switch the machine on or off.
- 2. MODE: Press to switch the operation modes between cool, heat, dry and fan.
- 3. MODE Indicator: This displays the Modes Setting between cool, heat, dry and fan.
- 4. SLEEP: Press to turn sleep mode on or off.
- 5. DOWN: Decreasing the desired temperature or timer setting.
- 6. SWING: Adjust the air flow direction vertically.
- 7. SPEED: Press to switch the fan speed in HIGH, MIDDLE and LOW.
- 8. Indicators: LED for high speed & middle speed & low speed and wifi.
- 9. TIMER: Set a time for the unit to automatically start or stop.
- 10. UP: Increasing the desired temperature (60.8°F/16°C~89.6°F/32°C) or timer setting.
- 11. Digital Display: Displays timer setting and temperature.
5.3 REMOTE CONTROL
An image of a remote control is shown with buttons for Timer, Speed, Swing, Sleep, Mode, Power, Heat, Cool, Dry, Fan, Up, Down, and °C/°F.
5.4 SETTINGS
5.4.1.Start-up and Shutdown
- Press POWER to turn the unit on. The unit runs in FAN as default.
- Press MODE button to select the desired operation mode.
- Press POWER again to turn off the power.
5.4.2.Operation mode
The unit has five operation modes: Cool, Heat, Dry, Fan, Sleep
A. Cooling your room
Select the cool mode to lower the temperature in your room. Press MODE button repeatedly until the LED of COOL operation lights up. Press Up/Down button to adjust the temperature which is displayed on the screen. The temperature can be set between 60.8°F/16°C and 89.6°F/32°C. Press SPEED button repeatedly until the desired fan speed indicator lights up. To control the direction of the air flow horizontally, please press the SWING button on. Note: The air conditioner stops if the room temperature is lower than the selected temperature.
B. Heating your room (Optional for Heating Function Unit only)
Press MODE button repeatedly until the LED of HEAT operation lights up. Press ADD/MINUS button to set the temperature higher than the room temperature. The fan speed can also be set. Note: The drainage hose should be attached to the unit for continuous operating.
C. Ventilating your room
Press MODE button repeatedly until the LED of FAN operation lights up. In ventilation mode, the room air is circulated, but not cooled. Press SPEED button repeatedly to select the fan speed as desired.
D. Drying your room
Press MODE button on the control panel or remote control, the LED of DRY operation lights up. The fan speed is unable to select. User should connect the hose to the drain outlet at the bottom of the unit. Note: In this mode, the fan speed switches over to low speed and the temperature cannot be selected.
E. Sleep mode
The sleep mode can be activated when in cool mode.
- In cool mode: After 1 hour the preset temperature is increased by 1°C, after another hour the preset temperature will again be increased by 1°C. Then the temperature is kept constant for 10 hours. And all the indicators dim to dark. The fan speed may switch over to low speed for silent operating and cannot be selected.
- In heat mode (Optional for Heating Function Unit only): After 1 hour the preset temperature is decreased by 1°C, after another hour the preset temperature will again be decreased by 1°C. Then the temperature is kept constant for 10 hours. And all the indicators dim to dark. The fan speed may switch over to low speed for silent operating and cannot be selected.
5.4.3. TIMER SETTING (1hour-24hours)
The timer has two ways of operation:
- To turn off (When power on): Press Timer key to turn on the timer function. Press Up/Down repeatedly to set the delay OFF time.
- To turn on (When power off): Press Timer key to turn on the timer function. Press Up/Down repeatedly to set the delay ON time.
- Cancel timer: Press Up/Down repeatedly until the LED shows '00'. Note: when press POWER will also exit the timer setting.
5.4.4. Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation. The unit will automatically start defrosting and the POWER LED blinking. The defrost control sequence is as follows:
- A. When the unit operates in the cooling operation, drying operation, the ambient temperature sensor senses the evaporator coil temperature is below -1°C, after the compressor will stop operating for 10 minutes or the coil temperature up to 7°C, the unit restarts to cool operating mode.
- B. When the unit operates in the drying operation, once the coil temperature sensor senses the temperature of the evaporator is below 40°C and the differential temperature between coil temperature and room temperature is below 19°C after the compressor operation for 20 minutes, the unit starts defrosting for 5 minutes and the power indicator blinking.
5.4.5. Overload Protection
In the event of a power loss, to protect the compressor there is a 3-minute delay until the compressor restarting.
DRAINAGE
Manual drainage:
- 1) When the machine stops after the water is full, please unplug the power plug. Notes: Please move the machine carefully, so as not to spill the water in the water pan at the bottom of the body.
- 2) Place the water container below the side water outlet behind the body.
- 3) Unplug the water plug, the water will automatically flow into the water container. Notes: 1. Keep the water plug properly. 2. During drainage, the body can be tilted slightly backwards. 3. If the water container cannot hold all the water, before the water container is full, stuff the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet.
- 4) When the water is discharged, stuff the water plug. Notes: Restart the machine after the water plug and drainage cover are installed, otherwise condensate water of the machine will flow to the floor or the carpet.
Continuous drainage
The self-evaporating system uses the collected water to cool the condenser coils for better efficient performance. There is no need to empty the drainage tank in cooling operation except in drying operation and high humidity conditions. The condensate water evaporates at the condenser and is evacuated through the exhaust hose. For continuous operation or unattended operating in drying operation, please connect the attached drain hose to the unit. Condensate water can be automatically flow into a bucket or drain by gravity. densate water of the machine will flow to the floor or the carpet.
- Switch off the unit before operating.
- Remove the plug of the water outlet opening, and keep it in safe area.
- Securely and properly connect the drain hose and make sure it is not kinked and clear of obstruction.
- Place the outlet of hose over a drain or bucket and ensure that water could freely flow out of the unit.
- Do not submerge the end of hose into water; otherwise it can cause "Air Lock" in the hose.
To avoid water spillage:
- As the negative pressure of condensate drain pan is large, tilt the drain hose downward toward the floor. It is appropriate that the degree of inclination should exceed 20 degrees.
- Straighten the hose to avoid a trap existing in the hose.
6. CLEANING AND CARE
6.1. CLEANING THE AIR FILTER (every two weeks)
Dust collects on the filter and restricts the airflow. The restricted airflow reduces the efficiency of the system and if it becomes blocked it can cause damage to the unit. The air filter requires regular cleaning. The air filter is removable for easy cleaning. Do not operate the unit without an air filter, or the evaporator may be contaminated.
- 1. Press POWER button to switch off the unit and unplug the power cord.
- 2. Remove the filter mesh from the unit.
- 3. Use a vacuum cleaner to suck dust from the filter.
- 4. Turn the filter over and rinse the air filter under running water. Let the water run through the filter in the opposite direction of air flow. Set aside and allow the filter to air dry completely before reinstalling.
Pic1. Switch off the unit and remove the two air filters. Pic2. Rinse the air filter under running water.
Warning!!! Do not touch the evaporator surface with bare-hand, or could cause injury of your fingers.
6.2. CLEANING UP OF REFRIGERANT
General Measures:
- Gas/vapor is heavier than air. May accumulate in confined spaces, particularly at or below ground level.
- Eliminate every possible source of ignition.
- Use appropriate personal protection equipment (PPE).
- Evacuate unnecessary personnel, isolate, and ventilate area.
- Do not get in eyes, on skin, or on clothing. Do not breathe vapors or gas.
- Prevent entry to sewers and public waters.
- Stop the source of the release, if safe to do so. Consider the use of water spray to disperse vapors.
- Isolate the area until gas has dispersed. Ventilate and gas test area before entering. Contact competent authorities after a spill.
7. TROUBLESHOOTING
Symptom | Inspection | Solution |
---|---|---|
The unit is not operating. | Check the power connection in securely. | Insert the power cord securely into the wall outlet. |
Check if the water level indicator lights up? | Empty the drain pan by removing the rubber plug. | |
Check the room temperature. | The range of operating temperature is 41-95°F/5-35°C. | |
Check the air filter for dirt. | Clean the air filter as necessary. | |
The unit works with reduced capacity. | Check if the air duct is blocked. | To clear the obstacle. |
Check if the room door or window is open. | Keep the door and windows closed. | |
Check if the desired operating mode is selected and the temperature is properly set. | Set the mode and temperature at proper setpoint according to the manual. | |
The exhaust hose is detached. | Make sure the exhaust hose is securely attached. | |
Water Leakage | Overflow while moving the unit. | Empty the water tank before transport. |
Check if the drain hose is kinked or bent. | Straighten the hose to avoid a trap existing. | |
Check if the unit is securely positioned. | Place the unit on horizontal and firm ground. | |
Excessive Noise | Check if any loose, vibrating parts. | Secure and tight the parts. |
Noise sounds like water flowing. | Noise comes from flowing refrigerant. This is normal. | |
Error Code | E0 Communication faults between main PCB and display PCB. | Check the wire harness of the display PCB for damage. |
E1 Ambient temperature sensor failure | Check connection or replace it. To clean or replace the temperature sensor. | |
E2 Coil temperature sensor failures. | Check connection or replace it. To clean or replace the temperature sensor. | |
Ft Condensate water high level alarm. | Empty the drain pan by removing the rubber plug. |
8. DECOMMISSIONING
8.1. STORAGE
Long-Term Storage - If you will not be using the unit for an extended period of time (more than a few weeks), it is best to clean the unit and dry it out completely. Please store the unit per the following steps:
- Unplug the unit and remove exhaust hose and window kit store with the unit.
- Drain the remaining water from the unit.
- Clean the filter and let the filter dry completely in a shaded area.
- Collect the power cord at the water tank.
- Re-install the filter at its position.
- The unit must be kept in an upright position when in storage.
- Preserving the machine in ventilating, dry, non- corrosive gas and safe place indoor.
ATTENTION: The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is turn on the machine, adjust it to low-wind ventilation mode, and maintain this state until the drainage pipe becomes dry, so as to keep the inside of the body in a dry state and prevent it from mildewing.
8.2. DISPOSAL
WARNING!!! Releasing refrigerant into atmosphere is strictly forbidden!
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
9. WIFI CONNECTION
9.1. Information on the App "Smart Life"
The "Smart Life" app is available for android and iOS. Scan the corresponding QR code to directly enter the download.
[QR code for downloading the Smart Life App]
Information on How to Use the App
This appliance allows you to operate the appliance via your home net-work. A prerequisite is a permanent WIFI connection to your router and the free app "Smart Life”.
Commissioning via the App
- Install the “Smart Life" app. Create a user account.
- Activate the WIFI function in the settings of your appliance.
- Place the appliance at a distance of about 5 meters to your router.
- As long as the power is turned on, the WIFI indicator flashes. After 3 minutes, the status will be canceled if there is no network configuration, and the indicator light is off. If you need to re-connect the WIFI, long press the “timer” button for 5 Seconds to start the network configuration, and the WIFI indicator will flash again.
WIFI Connection
- Method 1 Connected via Bluetooth Open the Bluetooth of your mobile phone or other device. When the WIFI indicator flashes, open the "Smart Life" APP, and the device will automatically connect with Bluetooth.
- Method 2 When WIFI indicator flashes, select “Add Device”-“Large Home Appliances”-“Portable Air Conditioner (Wi-Fi)", and follow the instructions on the display. Check the status of the WIFI indicator and choose the correct status. If the WIFI indicator flashes rapidly, it can be connected directly. If the WIFI indicator flashes slowly, press "Go to Connect” to connect the WIFI named "SmartLife-XXXX".