Phoenix Contact SAC-5P-2,0-28X/M12FS OD Sensor/Actuator Cable
Item Number: 1407258
Product Overview
The SAC-5P-2,0-28X/M12FS OD is a 5-position sensor/actuator cable designed for outdoor applications. It features a PE-X halogen-free, black-gray RAL 7021 cable with a length of 2 meters. The cable terminates in a free cable end on one side and a straight M12 socket with A-coding on the other. It is equipped with a high-grade steel knurl for secure connections.
Key Features:
- Easy and safe: 100% electrically tested plug-in components.
- Robust: Resistant to oil, UV, and ozone.
- Wide temperature range: Withstands temperatures from -40°C to +105°C.
Commercial Data
Attribute | Value |
---|---|
Item number | 1407258 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Sales key | BF03 |
Product key | AF1CDA |
GTIN | 4046356773751 |
Weight per piece (including packing) | 150.2 g |
Weight per piece (excluding packing) | 149.3 g |
Customs tariff number | 85444290 |
Country of origin | PL |
Technical Data
Product Properties
Attribute | Value |
---|---|
Product type | Sensor/actuator cable |
Application | External areas |
Number of positions | 5 |
No. of cable outlets | 1 |
Shielded | no |
Coding | A |
Insulation Characteristics
Degree of pollution: 3
Material Specifications
Attribute | Value |
---|---|
Flammability rating according to UL 94 | V0 |
Seal material | FPM |
Material of grip body | PP |
Contact material | CuSn |
Contact surface material | Ni/Au |
Contact carrier material | PP |
Material for screw connection | Stainless steel |
Electrical Properties
Attribute | Value |
---|---|
Insulation resistance | ≥ 100 MΩ |
Nominal voltage UN | 48 V AC / 60 V DC |
Nominal current IN | 4 A |
Mechanical Properties
Insertion/withdrawal cycles: ≥ 100
Signaling
Attribute | Value |
---|---|
Status display | no |
Status display present | no |
Connection Data
Conductor Connection
- Tightening torque: 0.4 Nm (M12 connector)
Connector
- Connection 1 Type: free cable end
- Connection 2 Type: Socket straight M12
- Number of positions: 5
- Coding type: A
Cable/Line Details
General
- Cable length: 2 m
- Cable weight: 70 kg/km
- Number of positions: 5
- Shielded: no
- Cable type: PE-X black [28X]
Conductor Structure
- Conductor structure signal line: 28 x 0.15 mm
- AWG signal line: 20
- Conductor cross section: 5 x 0.5 mm²
- Wire diameter incl. insulation: 1.6 mm ± 0.05 mm
Dimensions
- External cable diameter: 6.80 mm ± 0.2 mm
- Smallest bending radius, fixed installation: 34 mm
- Smallest bending radius, movable installation: 68 mm
Materials
- Outer sheath, material: PE-X
- External sheath, color: black-gray RAL 7021
- Conductor material: Bare Cu litz wires
- Material, filler: PP yarn
- Material wire insulation: PE-X
Electrical Characteristics
- Max. conductor resistance: ≤ 39 Ω/m (at 20°C)
- Insulation resistance: ≥ 100 MΩ·km (at 20°C)
- Nominal voltage, cable: ≤ 300 V AC
- Test voltage: ≥ 3000 V AC (Spark test)
Mechanical Durability
- Minimum bending radius, fixed installation: 5 x D
- Minimum bending radius, flexible installation: 10 x D
- Dynamic load capacity (bending): Max. bending cycles: 2,000,000, Bending radius: 10 x D, Traversing path: 10 m, Traversing rate: 3 m/s, Acceleration: 10 m/s²
Environmental Resistance & Properties
- Halogen-free: in accordance with DIN VDE 0472 part 815
- Flame resistance: According to DIN EN 60332-1-2, DIN EN 50267-2-1, DIN EN 50266-2-5, IEC 60332-3-25 (bunched fire test)
- Resistance to oil: According to DIN EN 60811-2-1, 168 h at 100°C; According to DIN EN 50306
- Other resistance: Resistance to fuels (according to IEC 60811, 168 h at 70°C); UV resistant (according to DIN VDE 0276-605)
- Special properties: Irradiated
Ambient Temperature (Operation)
- Cable, fixed installation: -40°C to +105°C
- Cable, flexible installation: -15°C to +105°C
- Cable, drag chain applications: 20°C ± 5°C
Environmental and Real-Life Conditions
Ambient Conditions
Attribute | Value |
---|---|
Degree of protection | IP65, IP67, IP68, IP69K |
Ambient temperature (operation) (Plug / socket) | -40°C to +105°C |
Ambient temperature (operation) (On sudden changes in temperature) | -40°C to 85°C (according to IEC 61076-2-101) |
Standards and Regulations
M12 Connector
Attribute | Value |
---|---|
Standard designation | IEC 61076-2-101 |
Drawings
Dimensional Drawing
A diagram showing the dimensions of the M12 x 1 socket, straight connection.
Schematic Diagram
A diagram illustrating the pin assignment for the M12 socket, 5-position, A-coded, socket side view.
Pin Assignment M12 socket, 5-pos., A-coded:
- Pin 1: Brown
- Pin 2: White
- Pin 3: Blue
- Pin 4: Black
- Pin 5: Gray
Circuit Diagram
A circuit diagram showing the contact assignment of the M12 socket, with lines connecting to conductor color codes: BN, WH, BK, BU, GY.
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1407258
- DNV Approval ID: TAE00002K4
- EAC-RoHS Approval ID: RU D-DE.HB35.B.00387
Classifications
ECLASS
- ECLASS-13.0: 27060311
- ECLASS-15.0: 27060311
ETIM
- ETIM 9.0: EC001855
UNSPSC
- UNSPSC 21.0: 26121600
Environmental Product Compliance
- EU RoHS: Fulfills EU RoHS substance requirements.
- China RoHS: Environment friendly use period (EFUP) - Yes, No exemptions.
- EU REACH SVHC: REACH candidate substance (CAS No.): 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol (CAS: 119-47-1).
- SCIP: 33496967-7349-49e5-8bf4-bd5ed2e1237e
- EF3.0 Climate Change: CO2e kg - 1.893 kg CO2e.
Contact Information
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300