Phoenix Contact SAC-4P-FR SCO RAIL Sensor/Actuator Cable
Product Number: 1412168
Product Overview
This document provides detailed technical data for the SAC-4P-FR SCO RAIL sensor/actuator cable from Phoenix Contact. This cable is designed for railway applications and features an angled M12 SPEEDCON socket.
Key Features:
- 4-position, shielded design
- M12 SPEEDCON connector
- Free cable end
- Cable length: Free input (0.2 ... 40.0 m)
- Suitable for railway applications
Your Advantages
- Easy and safe: 100% electrically tested plug-in components
- Securely locked by special vibration brake
- Resistant to temperature influences - tested for an extended temperature range and for resistance to temperature shocks
- Reliable signal transmission - 360° shielding in environments with electromagnetic interference
Commercial Data
Item | Details |
---|---|
Item number | 1412168 |
Packing unit | 1 pc |
Minimum order quantity | 1 pc |
Note | Made to order (non-returnable) |
Product key | AF1CJA |
GTIN | 4046356993661 |
Country of origin | PL |
Technical Data
Product Properties
- Product type: Sensor/actuator cable
- Application: Railway applications
- Number of positions: 4
- No. of cable outlets: 1
- Shielded: Yes
- Coding: A
Insulation characteristics
- Overvoltage category: II
- Degree of pollution: 3
Material specifications
- Flammability rating according to UL 94: V0
- Seal material: NBR
- Material of grip body: PA 6.6
- Contact material: CuSn
- Contact surface material: Ni/Au
- Contact carrier material: PA 6.6
- Material for screw connection: Zinc die-cast, nickel-plated
- Standards/regulations: PA 6.6
Electrical properties
- Insulation resistance: ≥ 100 MΩ
- Nominal voltage UN: 250 V AC / 250 V DC
- Nominal current IN: 4 A
Mechanical properties
- Insertion/withdrawal cycles: ≥ 100
Signaling
- Status display: No
- Status display present: No
Connection data
- Conductor connection: Free cable end
- Connector Type: Socket angled M12 SPEEDCON
- Number of positions: 4
- Locking type: SPEEDCON
- Coding type: A
Cable/line
- Cable length: Free input (0.2 ... 40.0 m)
- Cable weight: 56 kg/km
- Number of positions: 4
- Shielded: Yes
- Cable type: Shielded black RADOX® [28R]
- Conductor structure signal line: 19x 0.18 mm
- AWG signal line: 20
- Conductor cross section: 4x 0.5 mm²
- Wire diameter incl. insulation: 1.43 mm
- External cable diameter: 5.40 mm ±0.3 mm
- Outer sheath, material: PE-X
- External sheath, color: Black RAL 9005
- Conductor material: Tin-plated Cu litz wires
- Material wire insulation: PE-X
- Single wire, color: White 1, White 2, White 3, White 4
- Overall twist: 4 wires, twisted
- Shielding: Tinned copper braided shield
- Optical shield covering: 85%
- Max. conductor resistance: ≤ 40.1 Ω/km
- Nominal voltage, cable: 600 V AC (Core-ground, U₀), 1000 V AC (Core-ground, U), ≤ 720 V AC (core-ground), ≤ 1200 V AC (Core-ground, U<0xE2><0x82><0x98>), ≤ 900 V DC (Core-ground, V₀), ≤ 1500 V DC (Line-line)
- Test voltage: 3500 V AC (50 Hz, 5 min.), 8400 V DC (50 Hz, 5 min.)
- Minimum bending radius, fixed installation: 3 x D
- Minimum bending radius, flexible installation: 4 x D
- Smallest bending radius, fixed installation: 17 mm
- Smallest bending radius, movable installation: 22 mm
- Halogen-free: In accordance with EN 50267-2-1
- Flame resistance: IEC 60332-1-2, EN 50266, EN 50305, 9.1.2, NF C32-070, 2.1, NF C32-070, 2.2, UL 1685, 12 (FT4)
- Fume corrosiveness: In accordance with ISO 6722-1 5.22 (UN ECE-R 118.01), EN 50267-2-2
- Fume toxicity: BS 6853 B.1, EN 50305, 9.2
- Concentration of fumes: BS 6853 D.8.7, EN 61034-2, UL 1685, 12 (FT4)
- Resistance to oil: According to IRM 902, 72 h at 100 °C
- Fire protection in rail vehicles: BS 6853 (Category Ia, Ib, II), GM/RT 2130 (Category Ia, Ib, II), EN 45545 (Risk level HL1 - HL3), DIN 5510 (Fire protection level 1, 2, 3, 4), NF F16-101 (Category A1, A2, B), NF F16-101 (Class C/F0), NFPA 130, UNI CEI 11170 (Risk level LR1 - LR4)
- Other resistance: Resistance to fuels (according to IRM 903, 168 h at 70 °C)
- Ambient temperature (operation): -50 °C ... 120 °C (cable, fixed installation), -25 °C ... 90 °C (Cable, flexible installation)
Environmental and Real-life Conditions
- Ambient conditions
- Degree of protection: IP65
- Ambient temperature (operation) (male connector/female connector): -40 °C ... 85 °C (Plug / socket)
Standards and Regulations
- M12 connector
- Standard designation: M12 connector
- Standards/specifications: IEC 61076-2-101
- Standard designation: Shock, vibration
- Standards/specifications: EN 50155
Drawings
Dimensional drawing
A diagram shows a socket M12 SPEEDCON, angled, shielded. Key dimensions are indicated: Ø14.8 mm for the M12 connector, and a total length of 32.4 mm.
Schematic diagram
A circular diagram shows a 4-pin M12 socket, A-coded, viewed from the female side. The pins are numbered 1, 2, 3, and 4. Pin 1 is at the top right, Pin 2 at the bottom left, Pin 3 at the top left, and Pin 4 at the bottom right.
Circuit diagram
A wiring diagram shows the contact assignment of the M12 socket. Pin 1 is connected to WH 1, Pin 2 to WH 2, Pin 3 to WH 3, and Pin 4 to WH 4.
Approvals
To download certificates, visit the product detail page: https://www.phoenixcontact.com/us/products/1412168
- EAC: EAC-RoHS, Approval ID: RU D-DE.HB35.B.00387
Classifications
Classification System | Code | Value |
---|---|---|
ECLASS | ECLASS-13.0 | 27060311 |
ECLASS | ECLASS-15.0 | 27060311 |
ETIM | ETIM 9.0 | EC001855 |
UNSPSC | UNSPSC 21.0 | 26121600 |
Environmental product compliance
- EU RoHS: Fulfills EU RoHS substance requirements (Yes, No exemptions)
- China RoHS: Environment friendly use period (EFUP): EFUP-E. No hazardous substances above the limits.