User Guide for ZKTECO models including: C2-260 inBio2-260, Access Controller, C2-260, inBio2-260 Access Controller, C2-260 inBio2-260 Access Controller

C2-260&C2-260FP Quick Start Guide V1.1-20200323 update 02

C2-260&C2-260FP Quick Start Guide V1.1-20200323 update 02

Завантажити

◁ Мережевий контролер доступу ZKTeco C2-260 купити за оптовими цінами в DEPS

Quick Start Guide - deps.ua

Safety Precautions Do not expose to direct sunlight, water, dust and soot. Do not place any magnetic objects near the product. Magnetic objects such as magnets, CRT, T V, monitors or speakers may damage the device. Do not place the device near any heating equipment. Prevent water, drinks or chemicals leaking into the device. This product is not intended for use by children unless they are ...

PDF preview unavailable. Download the PDF instead.

C2-260 Quick Start Guide 3rd 20200423 compressed
Quick Start Guide
C2-260/inBio2-260 Access Controller
Version: 1.1
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.

What's in the Box

NC COM NO SEN GND BUT NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

C2-260 / inBio2-260

4 Screws & Anchors

2 Screwdrivers 1

4 Diodes

Safety Precautions
The following precautions are to ensure user's safety and prevent any damage. Please read the instructions carefully before installation.
Do not expose to direct sunlight, water, dust and soot. Do not place any magnetic objects near the product. Magnetic objects such as magnets, CRT, T V, monitors or speakers may damage the device. Do not place the device near any heating equipment. Prevent water, drinks or chemicals leaking into the device. This product is not intended for use by children unless they are supervised. Do not drop or damage the device. Do not disassemble, repair or modify the device. Do not Remove dust or dirts regularly. While cleaning, wipe the dust off with a smooth cloth or towel instead of water. Contact your supplier in case of any query.
2

Product PIN Diagram
2 Lock & Door Sensor 2 Aux Output 2 Aux Input

NC COM NO SEN GND BUT NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

12V Power in 12V Power out
RS485 Reader RS485 Communication DIP Switch USB Port
Ethernet Port

Figure 1 3

LED Indicators
Figure 2 PWR
Figure 3 RUN
Figure 4 TCP/IP
Figure 5

LINK Solid Green LED indicates TCP/IP communication is normal.
Flashing (ACT )Yellow LED indicates data communication is in progress.
Solid (POWER) Red LED indicates the panel is powered on.
Slowly flashing Green LED indicates normal working status of the system.
TCP/IP continuously flashing Yellow LED indicates data transmission.
TCP/IP slowly flashing Yellow LED indicates real-time monitoring status.
4

Panel Installation
Wall Mounting

NC COM NO SEN GND BUT NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

Step 1
Drill holes on the wall

Figure 6

Step 2
Fix the device with four screws

Rail Mounting

Step 1
Fix the guide rail on the wall

Figure 7 5

Step 2
Fix the device to the rail mounting.

7
Panel Installation

Normally Close Lock

Normally Open Lock

Exit Button

IR Sensor Floodlight Detector

FIRE ALARM

EKLY PUS

H TOTESTWE

HTOTESTWE

EKLY PUS

NC COM NO SEN GND BUT NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

RS485

Ethernet Cable 485 Convertor RS485 Reader 12V DC Power Supply Figure 8
The auxiliary input may be connected to infrared body detectors, fire alarms, or smoke detectors. The auxiliary output may be connected to alarms, cameras or door bells, etc.
6

Installation Diagram
Ethernet Communication wire 220/110 V Input
Outdoor RS485 reader

RS485 Communication wire C2-260/inBio2-260 Access Control Bundle
CEILING Sensor Electric Lock
Exit Button
Indoor RS485 reader

OUTDOOR

Figure 9 7

INDOOR

RS485 Readers Connection

NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

BUT

GND

SEN

NO

COM

NC

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

C2-260 / inBio2-260 DC12V

TCP/IP

Router

485A 485B
GND +12V

#1Reader

#2Reader

#3Reader

FR1200

(inBio2-260)

Note: 1. It's recommended to connect maximum four readers to one C2-260/inBio2-260. 2. A single RS485 reader interface can supply a maximum of 750 mA (12V) current. So the
entire current consumption should be less than this max value when the readers share the power with the panel. 3. Only inBio2-260 supports connection with FR1200 readers.

8

Additional Modules of RS485
Connection with DM10

NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

BUT

GND

SEN

NO

COM

NC

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

C2-260 / inBio2-260 DC12V

TCP/IP

Router

485A 485B
GND

DM10

DC12V

DM10

Note: 1. A C2-260/inBio2-260 can connect to maximum eight DM10 modules.. 2. Each DM10 module requires a separate power supply.

DC12V

9

Connection with AUX485

NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

BUT

GND

SEN

NO

COM

NC

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

C2-260 / inBio2-260 DC12V

TCP/IP

Router

DC12V

DC12V

485A 485B
GND

AUX Input Device

AUX485

AUX485

Note: 1. A C2-260/inBio2-260 can connect to maximum two AUX485 modules. 2. Each AUX485 module can connect to maximum four auxiliary devices. 3. Each AUX485 module requires a separate power supply.

AUX Input Device

9

Connection with WR485

NC COM NO SEN GND BUT NC COM NO NC COM NO AUX GND AUX

BUT

GND

SEN

NO

COM

NC

LOCK1

LOCK2

AUX OUT

AUX IN

PWR RUN TCP/IP

RS485 DIP

RS485

READER

VOUT POWER

GND 485B 485A 12VRD GND 485B 485A +12V GND +12V GND

C2-260 / inBio2-260 DC12V

TCP/IP

Router

485A 485B GND
+12V

WR485

WR485

Note: 1. A C2-260/inBio2-260 can connect to maximum four WR485 modules.

10

Connection to ZKBioAccess Software

Here the connection between C2-260/inBio2-260 and AUX485 is used as an example to illustrate the software settings. After proper wiring, perform the following steps: 1. Set the RS485 address of AUX485 from 1-15. 2. Inclusion of C2-260/inBio2-260 to software:
Open the ZKBioAccess Software. Click [Access] > [Device] > [Device] > [New], enter the relevant information, and then click [OK].

Step 2

Step 1 S tep 3

Step 4
After adding successfully, the TCP/IP indicator of inBio2-260 flashes every two seconds, indicating the communication is normal. 3. Inclusion of AUX485 module to the software:
Click [Device] > [I/O Board] > [New], enter the name and RS485 address of AUX485, and then click [OK].
11

4. Click [Device] > [Auxiliary Input] to view all the auxiliary inputs.
Note: For other specific operations, please refer to ZKBioAccess User Manual. 12

Specifications

Model Number of Doors Supported by Default
Number of Auxiliary Inputs Number of Auxiliary Outputs
RS485 Extension Port RS485 Reader Port
Number of Readers Supported Types of Readers Supported
DM10 (Single-Door Extension Board) (Optional) AUX485 (RS485-4 Aux. IN Converter) (Optional)
WR485 (RS485-Weigand Converter) (Optional) Card Capacity Log Capacity Communication CPU RAM Power
Dimensions (L*W*H) Operating Temperature
Operating Humidity

C2-260 2 2 2 1 1 4
RS485 card reader, Wiegand reader (WR485) Max. 8 2 4 30,000 200,000
TCP/IP, RS458 32-bit 1.0GHz
64MB 9.6V - 14.4V DC 116.47*96.49*31.40 mm -10°C to 50°C / 14°F to 122°F
20% to 80%

ZKTeco Industrial Park, No. 26, 188 Industrial Road, Tangxia Town, Dongguan, China. Phone : +86769-82109991 Fax : +86755-89602394 www.zkteco.com
Copyright © 2020 ZKTECO CO., LTD. All Rights Reserved.


Adobe Illustrator CC (Windows) www.ilovepdf.com