Multi-screen interface design display:
ATORCH
Startup Screen
Measurement interface 1
Parameter | Value | Unit/Details |
---|---|---|
Voltage | 9.306 | V |
Current | 1.609 | A |
Time | 0000:01:31 | |
Capacity Percentage | 0014.97 | % |
Power/Energy | 0008.22 | h (Wh) |
Capacity | 00008 | mAh |
Temperature | 34 | °C / 93 °F |
Associated parameters: Power, Electricity Power, Capacity, Temperature.
Measurement interface 2
Parameter | Value | Unit/Details |
---|---|---|
Voltage | 30.06 | V |
Current | 1.709 | A |
Resistance | 999.9 | Ω |
Capacity Percentage | 0051.37 | % |
Power/Energy | 0008.22 | h (Wh) |
Capacity | 00008 | mAh |
Temperature | 34 | °C / 93 °F |
Associated parameters: Current, Resistance, Capacity, Temperature.
USB four-wire detection interface
Parameter | Value | Unit/Details |
---|---|---|
GND | ||
USB D+ Logic Voltage | 1.99 | V |
USB D- Logic Voltage | 2.51 | V |
Supply Voltage | 19.7 | V |
Supply Current | 2.600 | A |
Time | 0000:30:28 | |
Load Impedance | 07.59 | Ω |
Power/Energy | 0007.03 | h (Wh) |
Capacity | 00058 | mAh |
Capacity Percentage | 0051.35 | % |
Associated parameters: Load impedance, Electricity Power, Capacity, Current/Power, Temperature.
Background calibration interface
Setting | Value | Action |
---|---|---|
Reference 5V Standard Voltage Calibration | 5.064 V | (Standard voltage source) |
No-Load Reset | 0.000 % | (Current clear zero when no load) |
Reference 2A Standard Current Calibration | 0.000 A | (Standard constant current load instrument) |
Reset | [Reset] | |
Reset Factory settings | [Reset Factory settings] |
Key button operation instructions:
- Short Press key button to switch screen
- Long press key button the screen to flip
- Quickly double-click key button the power Wh to clear zero
- Fast three-click capacity mAh to clear zero
- Fast four-click time to clear zero
Color screen display on/off function:
By pressing the button to switch the interface to the information screen to turn off the display, you can also charge the device normally! Click the button to wake up the display again.
Software calibration technology:
Press and hold the USB tester button when no power is on, and insert the USB charger to enter the background calibration mode. Press the button shortly to switch to the corresponding calibration function, long press to confirm the corresponding calibration function!
Tips: This calibration must use 5V standard voltage and 2A constant current power supply, no misoperation is allowed.
Technical parameters:
Parameter | Range | Resolution Precision |
---|---|---|
Voltage measuring | 3.60V ~ 32.5 V | 0.01 V |
Current measuring | 0.00A ~ 5.00 A | 0.01 A |
Power cumulative | 0 ~ 999999 Wh | 0.001 Wh |
Capacity | 0 ~ 999999 mAh | 0.001 Ah |
Temperature | 0 °C ~ +80 °C | 1 °C |
D+ Voltage | 0.000V ~ 2.999 V | 0.001 V |
D- Voltage | 0.000V ~ 2.999 V | 0.001 V |
Load impedance | 0 ~ 999 Ω | 1 Ω |
Power metering | 0 ~ 299.999 W | 0.001 W |
Timing maximum time | 999 h 59 m 59 s | 1 s |
Time to refresh | > 500 ms/time > 500 ms/times | |
Measurement rate | 0.5 times/s | |
Working temperature | -10 ~ +60 °C | |
Working humidity | 10 ~ 80 (no doubt) | |
Pressure of work | 80 ~ 106 kPa |