User Guide for FANMASTER models including: IDF-100E In line Duct Fans, IDF-100E, In line Duct Fans, Duct Fans, Fans

Product Catalog Template

MrTemplater

Download

Fanmaster Catalogue: Quality Cooling Solutions


File Info : application/pdf, 22 Pages, 13.14MB

PDF preview unavailable. Download the PDF instead.

Mini-Catalogue-–-HVAC-Electrical-Building-Construction
FANMASTER
cooling heating ventilation extraction
More than fans
PRODUCT GUIDE
Cooling, Extraction & Ventilation Solutions HVAC, Electrical, Building & Construction Edition

2024/2025

PRODUCT GUIDE
Cooling, Extraction & Ventilation Solutions HVAC, Electrical, Building & Construction Edition
This comprehensive guide is designed to assist professionals in the HVAC, electrical, building and construction industries with their cooling, extraction and ventilation requirements. Explore our extensive range of high-quality products, including evaporative coolers, extraction fans, and more. We offer Australian-made options and trusted brands like Ouber and Icen. Let Fanmaster be your partner in creating optimal temperature control and air quality solutions.
BECOME AN INSTALLER
We are always on the lookout for professional installers with trades in air conditioning, electrical or roofing who are reliable, focused on customer satisfaction and have a high level of workmanship. If you are a tradesperson, sub-contractor or established business looking for an opportunity to expand your business and increase your sales, please contact us.
Scan for Full Product Catalogue
1

TABLE OF
CONTENTS

> Welcome
Installed/Fixed Solutions
> Ventilation/Extraction Wall Exhaust Fans Axial Flow Fans In-line Duct Fans Roof Fans Fume Arms
> Cooling Evaporative Cooler HVLS Fans Wall Fans
Portable Solutions
> Cooling Portable Evaporative Portable Air Conditioners

1
3-10 3-5 6 7 8-9 10
11-16 12 13-14 15-16
17-20 17-18 19-20
2

VENTILATION/EXTRACTION

What is Cross Flow Ventilation?
Cross flow ventilation is a natural ventilation strategy that uses the wind to move air through a building. It involves opening windows or doors on opposite sides of the building so that the air can blow through the space. This creates a current of air that helps to remove stale air and replace it with fresh air. A mechanical solution for this would be to add fans for a consistent air flow e.g. Roof Fans or Wall Exhaust Fans.

Confined Space Ventilation
Confined space ventilation is the process of removing stale air, hazardous gases, vapours, fumes and dusts from a confined space to create a safe atmosphere for workers to enter and work.

When extracting air from a confined space, clean air needs to come from somewhere. If no clean air is available to enter the confined space through a large drain or vent (natural ventilation), it is necessary to consider blowing fresh air in. Using fans (mechanical ventilation) by supplying fresh air into an area we still need to find clean air from somewhere; it may be as simple as placing the fan at some distance away or outside a building and ducting the air in.

Products such as the Compact Air Blaster, Purging Fan and Portable Exhaust Blowers are ideal for confined space ventilation.

WALL EXHAUST EXTRACTION FANS IWEL200, IWEL250, IWEL300, IWEL350, IWEL400

FANMASTER
cooling heating ventilation extraction

Features:
· Extracts large volumes of air
· Easy to install · Cost effective and efficient · Self closing louvres stop reverse airflow · Ready to be hard-wired in · Plug not included
· 240V

Applications: · Warehouse, Workshops & Factories · Garages
· Agriculture
· Horticulture

SPECIFICATIONS Air Flow
Noise Level Motor Voltage Current
Plug Connection
Fan Speed Speed
Diameter

UNIT L/S dBa W
A
RPM mm

IWEL200
250 <45 45 240 0.12 Hard wired 1 1400 200

IWEL250
280 <50 45 240 0.12 Hard wired 1 1400 250

IWEL300 300 <58 45 240 0.19
Hard wired
1 1400 300

IWEL350 630 <65 75 240 0.31
Hard wired
1 1400 350

IWEL400 800 <67 145 240 0.60
Hard wired
1 1400 400

3

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

WALL EXHAUST EXTRACTION FANS IWLF6-11-6, IWLF6-11-6-3

Features:
· Galvanised Steel Body · Rain Cover · Internal Gravity Louvres · Safety Wire Guards
· Supply or Exhaust · Used to exhaust heat, smoke, fumes,
dust or provide ventilation

Applications: · Warehouse, Workshops & Factories · Agriculture
· Horticulture

IWLF6-11-6 uses a phase converter enabling the use of single phase power supply.

SPECIFICATIONS Air Flow
Noise Level Motor Voltage
Controller
Current Plug Connection
Fan Speed Speed
Insulation Class IP Rating
Material of Blades Material of Body
Material of Louvres
Measurements

UNIT L/S dBa kW
A RPM
mm

IWLF6-11-6
5000 <70 1.1 380 PInhpauste: C1oPnHv2e2rt0eVr Output: 3PH 220V 5 Hard wired 1 6P F IP44 Nylon & Glass Fibre Galvanised Steel
PVC
830(L)x430(D)x770(H)

IWLF6-11-6-3 5000 <70 1.1 380
-
2.6 Hard wired
1 6P F IP44 Nylon & Glass Fibre Galvanised Steel
PVC 830(L)x430(D)x770(H)

WALL EXHAUST EXTRACTION FANS IGLF950, IGLF1250

FANMASTER
cooling heating ventilation extraction

Features: · Built to last

Applications: · Warehouse, Workshops & Factories

· Extracts large volumes of air

· Agriculture

· Easy to install

· Belt driven motor

· Quiet operation · Louvres stop reverse air flow and weather when not on

SPECIFICATIONS
Air Flow Noise Level
Motor Voltage Current Plug Connection Fan Speed Speed Weight Diameter Pack Dimensions

UNIT L/S dBa W
A
RPM kg mm mm

IGLF950
9000 <60 750 415 1.04 Hard wired 1 450 55 950 1060*400*1060

IGLF1250
12,500 <65 1100 415 1.53
Hard wired 1 450 85
1250 1380*400*1380

4

VENTILATION/EXTRACTION

INDUSTRIAL WALL EXHAUST FANS IW3, IW4, IW5, IW6, IW8, IW10

FANMASTER
cooling heating ventilation extraction

Features:
· Designed to exhaust or supply air · Fitted with finger guards

Applications: · Warehouse, Workshops & Factories
· Agriculture

· Powder coated steel casing · IP55 motor standard (IP65 available)
· Fixed louvres available

· Construction sites
· Events & military · Rental & Emergency

· Made in Australia

· Suited for environments to remove heat, steam and dust · Exe & Exd motors are available on sizes starting from 400mm

PART # IW3-370-4 IW3-370-4-3 IW4-370-4 IW4-370-4-3 IW4-550-2 IW4-550-2-3 IW5-550-4 IW5-550-4-3 IW5-550-4-3E IW6-750-4 IW6-750-4-3 IW6-750-4-3E IW6-11-4 IW6-11-4-3 IW6-11-4-3E IW6-15-4 IW6-15-4-3 IW6-15-4-3E IW8-15-4 IW8-15-4-3 IW8-15-4-3E IW10-22-8-3

DIAMETER
300mm 300mm 400mm 400mm 400mm 400mm 500mm 500mm 500mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 800mm 800mm 800mm 1000mm

MOTOR
370W 370W 370W 370W 550W 550W 550W 550W 550W 750W 750W 750W 1100W 1100W 1100W 1500W 1500W 1500W 1500W 1500W 1500W 2200W

VOLTAGE
240V 415V 240V 415V 240V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 415V

MOTOR IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

FAN SPEED
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

POLES
4 4 4 4 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 8

AIR FLOW 425 L/s 425 L/s 1000 L/s 1000 L/s
2550 L/s 2550 L/s 2550 L/s 2950 L/s 2950 L/s 2950 L/s 4200 L/s 4200 L/s 4200 L/s
6570 L/s 6570 L/s 6570 L/s 12400L/s

INDUSTRIAL WALL & MANCOOLER GUARDS

PART # IWG300 IWG400 IWG500 IWG600 IWG800 IWG1000 IWG1200

SIZE
300mm 400mm 500mm 600mm 800mm 1000mm 1200mm

NON-RETURN LOUVRES

PART # IWL400 IWL500 IWL600 IWL800 IWL1000

SIZE
400 x 400mm 500 x 500mm 600x 600mm 800 x 800mm 1000 x 1000mm

B

C

E

G

A

D

F

DRUM

BLADE

A

B

C*

D

E

F

G*

Ø

Ø

300

280

400

400

400

300

100

25

-

400

380

500

500

400

400

100

25

-

500

480

600

600

400

500

100

25

-

600

580

700

700

400

600

100

25

-

800

780

900

900

400

800

100

25

-

1000

980

1100

1100

650

1000

100

25

-

*C - Can vary due to the size of the motor

5

*G - Motor plate varies due to motor size

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

AXIAL FLOW FANS

AF3, AF4, AF5, AF6, AF8, AF10

FANMASTER
cooling heating ventilation extraction

Features:
· Designed to remove heat, steam and dust · Inline axial fan · Built in flanges designed to attach to ducting

Applications: · Warehouse, Workshops & Factories · Agriculture
· Horticulture

· Powder coated rolled steel casing · IP55 motor standard (IP65 available)

· Paint shops

· Made in Australia · Ex e & Ex d motors are available on sizes starting from 400mm

· Hard wired

SPECIFICATIONS
AF3-370-4 AF3-370-4-3 AF3-550-2 AF3-550-2-3 AF4-370-4 AF4-370-4-3 AF4-370-4-3E AF4-750-2 AF4-750-2-3 AF4-750-2-3E AF5-750-4 AF5-750-4-3 AF5-750-4-3E
AF5-11-2 AF5-11-2-3 AF5-11-2-3E AF6-11-4 AF6-11-4-3 AF6-11-4-3E AF6-15-4 AF6-15-4-3 AF6-15-4-3E AF8-15-4 AF8-15-4-3 AF8-15-4-3E AF8-22-4 AF8-22-4-3 AF8-22-4-3E AF10-55-6-3

DIAMETER
300mm 300mm 300mm 300mm 400mm 400mm 400mm 400mm 400mm 400mm 500mm 500mm 500mm 500mm 500mm 500mm 600mm 600mm 600mm 600mm 600mm 600mm 800mm 800mm 800mm 800mm 800mm 800mm 1000mm

MOTOR
370W 370W 550W 550W 370W 370W 370W 750W 750W 750W 750W 750W 750W 1100W 1100W 1100W 1100W 1100W 1100W 1500W 1500W 1500W 1500W 1500W 1500W 2200W 2200W 2200W 5500W

VOLTAGE
240V 415V 240V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 240V 415V 415V 415V

IP RATING IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

FAN SPEED
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

POLE
4 4 2 2 4 4 4 2 2 2 4 4 2 2 2 2 4 4 4 4 4 4 4 4 4 4 4 4 6

AIRFLOW 680 L/s 680 L/s
1500 L/s 1500 L/s 1500 L/s
2700 L/s 2700 L/s 2700 L/s
3800 L/s 3800 L/s 3800 L/s 4550 L/s 4550 L/s 4550 L/s 6000 L/s 6000 L/s 6000 L/s 8000 L/s 8000 L/s 8000 L/s 12000 L/s

B C

D A
E

F

G

DRUM

BLADE

A

B

C

D

E

F

G

Ø

Ø

Ø

300

290

400

360

300

8

8

-

25

400

380

400

500

400

8

8

-

25

500

480

500

600

500

11

8

-

25

600

580

500

700

600

11

8

-

25

800

780

500

900

800

11

12

-

25

1000

980

700

1100

1000

11

12

274

25

6

VENTILATION/EXTRACTION

IN-LINE DUCT FANS

IDF

FANMASTER
cooling heating ventilation extraction

Features:
· Durable galvanised steel casing · High-efficiency EC motors (energy saving) · Quiet operation
· Compact design
· Easy installation and maintenance

Applications:
· Commercial - restaurants, cafes, hotels, and office buildings
· Industrial - workshops,
warehouses, and industrial
processes · Residential - bathrooms,
laundries, and kitchens

SPECIFICATIONS

Model No

Duct Size

Voltage Frequency

VAC V

Power W

Current (A)

RPM

Airflow m3/h

Static Pressure
Pa

Noise dBa

Maximum Efficiency Point Power
W

Maximum Efficiency %

10

39

0.35

2800

265

355

62

29.1

IDF-100E

100mm

230V 50Hz

8

25

0.24

2400

235

259

59

21.4

6

12

0.14

1800

179

148

52

10.8

27.17 24.85 21.08

10

40

0.35

2800

337

357

62

35.5

IDF-120E

120mm

230V 50Hz

8

24

0.23

2400

281

254

59

22.2

6

12

0.14

1800

214

147

51

11.2

30.31 28.94 30.58

10

42

0.37

2800

469

348

62

42.2

IDF-150E

150mm

230V 50Hz

8

28

0.25

2400

408

251

58

28.4

6

14

0.15

1800

306

142

50

14.1

30.58 30.21 26.05

10

42

0.37

2800

495

344

61

42.3

IDF-160E

160mm

230V 50Hz

8

26

0.25

2400

428

245

58

29.1

6

14

0.14

1800

326

142

50

14.4

31.18 32.93 29.01

10

112

0.89

2850

989

566

68

128.3

IDF-200E

200mm

230V 50Hz

8

66

0.55

2400

847

394

63

79.5

6

30

0.26

1800

612

219

56

34.1

41.67 41.81 38.87

10

118

0.93

2850

1071

581

68

128.4

IDF-250E

250mm

230V 50Hz

8

70

0.58

2400

887

411

64

84.9

6

31

0.28

1800

653

226

57

53.3

44.12 43.63 40.52

10

128

0.98

2750

1377

710

71

126.4

IDF-310E

310mm

230V 50Hz

8

82

0.67

2400

1173

497

68

125.7

6

35

0.31

1800

887

273

60

53.3

46.73 45.56 44.63

7

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

ROOF FANS

IHR4, IHR6, IHR8

FANMASTER
cooling heating ventilation extraction

Features: · Extracts heat, smoke, dust, or fumes from
all types of buildings including factories and warehouses · Used in conjunction with coolers to help lower temperatures during the hotter months · Constructed from high quality steel and aluminium for a weatherproof design

Applications: · Warehouse, Workshops & Factories
· Plants

SPECIFICATIONS
Air Flow Noise Level Motor Voltage Pole Plug Connection Material Cap Body/Base Weight

UNIT L/S dBa W V
kg

IHR4-550-4-3
1111  72 ± 5dB(A)
550 400~415
4 Hard wired Aluminium
Steel 26

IHR6-11-6-3
3600  71 ± 5dB(A)
1100 400~415
4 Hard wired Aluminium
Steel 105

IHR6-22-4-3
5200  75 ± 5dB(A)
2200 400~415
4 Hard wired Aluminium
Steel 110

IHR8-22-6-3
7778  78 ± 5dB(A)
2200 400~415
4 Hard wired Aluminium
Steel 125

PART #

ØA

H

IHR4-550-4-3

Ø650

550

IHR6-11-6-3

Ø1000

670

IHR8-22-6-3

Ø1390

750

h

LxL

GxG

N-ØK



355

520X520

470X470

4-Ø10

3

455

900X900

770X770

4-Ø14

3

480

1100X1100 1000X1000 4-Ø14

5

8

VENTILATION/EXTRACTION

CENTRIFUGAL ROOF FAN - DOWNBLAST RFCD

FANMASTER
cooling heating ventilation extraction

Features: · Robust fan cover resistant to high winds · Galvanised steel plate for durable support · Stepped flashing prevents water seepage · Galvanised bird-proof net protects the fan
· High-performance belt-driven centrifugal
roof exhaust fan · Ideal for general clean air applications · Durable spun aluminium housing for
corrosion and weather resistance

Applications:
· Mining plants
· Civil buildings
· Shopping Centres · Venues where efficient air
extraction and exhaust are
required

SPECIFICATIONS
Air Flow Size Motor
Voltage RPM

UNIT
m3/h mm kW

RFCD-200-120
700/870 200
0.12kW 415V/50Hz 1380/1650

RFCD-260-180
1204/1440 260
0.18kW 415V/50Hz 1380/1650

RFCD-320-250
2007/2400 320
0.25kW 415V/50Hz 1380/1650

RFCD-360-550
3386/4200 360
0.55kW 415V/50Hz 1380/1650

RFCD-500-22
9423/10722 500
2.2kW 415V/50Hz 1450/1740

CENTRIFUGAL ROOF FAN - UPBLAST
FANMASTER
cooling heating ventilation extraction

RFCU
Features: · Efficient airflow · Durable construction · Optimised motor · Weatherproof design · Safety features · Protected outlet

Applications:
· Mining plants
· Civil buildings
· Shopping Centres · Venues where efficient air
extraction and exhaust are
required

SPECIFICATIONS

Model No
RFCU-280-370 RFCU-315-550 RFCU-400-11 RFCU-450-22 RFCU-500-3 RFCU-560-3 RFCU-630-22 RFCU-800-55

Size mm Motor kW

280

0.37

315

0.55

400

1.1

450

2.2

500

3

560

3

630

2.2

800

5.5

Voltage/Hz
415V/50Hz 415V/50Hz 415V/50Hz 415V/50Hz 415V/50Hz 415V/50Hz 415V/50Hz 415V/50Hz

RPM

Airflow m3/h L/s

Static Pressure
Pa

Airflow @ Zero Static Pressure

m3/h

L/s

dBa Weight kg

1900 1984 551

277

2450 680 66

47

1650 2454 681

264

2850 791 55

55

1400 4263 1184 306

5300 1472

67

1450 6286 1746 416

7600 2111

88

1520 7735 2148 682 11,960 3322 78

95

1250 8937 2482 579 12,642 3511

930 9467 2629 405 14,165 3934

860 17,926 4979 559 26,500 7361

9

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

INDUSTRIAL FUME ARM

IFA2-160-2

Features:

FANMASTER

· ·

Flexible arm (Available in 2m & 3m lengths) Easy & silent operation

cooling heating ventilation extraction
·

Robust design

· Fume arm and suction tube made from flame-retardant material

Applications: · Welding fume extraction · Soldering fume extraction · Dust extraction

SCAN HERE FOR PORTABLE
OPTIONS

SPECIFICATIONS Power (kW) Voltage (V) Connection
Fan Type Airflow (L/s) Full wind pressure (Pa) Switch box
Suction arm Installation bracket
Noise Level Weight (kg) including suction arm

IFA2-160-2 1.5
415 ~/50Hz *Hardwired
Centrifugal fan 416±28 1800
Circuit breaker, plug and wire 160mm, 2m length, PP hood
280x330x503mm 74±5 43±2

IFA2-160-3 1.5
415 ~/50Hz *Hardwired
Centrifugal fan 416±28 1800
Circuit breaker, plug and wire 160mm, 3m length, PP hood
280x330x503mm 74±5 43±2

What is the Difference Between Extraction and Ventilation?
Extraction and ventilation are both terms used to describe the movement of air in a building. However, they have different meanings.
Extraction is the process of removing stale or polluted air from a building. This is typically done using fans or vents that are installed in specific areas, such as warehouses and bathrooms.
Ventilation is the process of introducing fresh air into a building. This can be done through natural means, such as open windows and doors, or through mechanical means, such as fans or vents.
In general, extraction is used to remove harmful pollutants from the air, while ventilation is used to introduce fresh air and improve the overall quality of the air.
10

COOLING

What is Evaporative Cooling?
Evaporative cooling is a form of air conditioning and is an alternate to traditional refrigerant-based air conditioning systems. Evaporative cooling utilises the natural process of evaporation to cool the air.

How it works?
Evaporative coolers use a low wattage water pump to circulate water from the water tank which then distributes the water across multiple cooling pads, which in turn become very wet. The fan draws the warm
ambient temperature through the damped cooling pads, as it passes
through the air is cooled by evaporation.

Advantages
· Less expensive to install · Less expensive to operate (vs. refrigerated air conditioning
systems) · Ease of maintenance
· Constant fresh air is supplied

Temperature Drop Chart

Outdoor Humidity

Outdoor Temperature

Outlet

10%

20%

30%

40%

50%

60%

70%

80%

90%

Temperature

25°C

12.0

13.0

14.5

15.7

17.5

19.1

21.5

22.3

23.7

27°C

13.5

14.5

16.5

17.4

20.0

21.2

23.0

24.6

27.0

30°C

15.5

16.5

19.0

20.4

22.5

23.9

26.0

27.6

30.0

32°C

17.0

18.0

21.0

22.6

25.0

26.6

29.0

30.4

32.0

35°C

19.0

20.0

23.0

24.8

27.5

29.1

31.5

33.1

37°C

20.5

22.7

25.0

26.8

29.5

31.1

33.5

40°C

22.0

23.8

26.5

28.3

31.0

33.0

42°C

23.0

25.0

28.0

29.8

32.5

45°C

24.0

25.9

28.9

30.8

11

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

FIXED EVAPORATIVE COOLERS

IDDAC-670

Features: · High air flow with low noise · Down draft air outlet · 4 x air inlets with filters
· LCD control panel with remote control · Low power consumption - 1.1kW, 240v
· Plumbed in for continuous water supply · Roof or wall mounted options
· Fresh cool air constantly supplied
· Fan only option

Applications: · Warehouse, Workshops & Factories
· Agriculture
· New & existing Commercial & Industrial builds
· Events & Military

WATCH ME FEATURES & APPLICATIONS

WATCH ME HOW IT WORKS

SPECIFICATIONS
Air Flow Fan Type Noise Level
Motor Voltage/Frequency
Current Plug Connection
Cooling Area Air Supply Distance
Tank Capacity Water Consumption
Fan Speed Cooling Pad Size Cooling Pad Thickness Material of Blades Material of Body
Weight Product Dimensions (L*D*H)
Pack Dimensions

UNIT L/S
dBa kW
A
m2 m L L/H
mm mm
kg mm mm

IDDAC-670
5,000 Axial <68 1.1 220~240/50 7.5 Hard Wired up to 150
22 25 20 Variable 700*770 100 ABS PP body 56/69 1080*1080*980 1080*1080*1000

12

COOLING
HVLS FANS
*

HVLS25, HVLS40, HVLS49, HVLS73

The Fanmaster HVLS Fan range is highly efficient and energy-saving. Utilising a permanent magnet brushless motor made of high-quality
NdFEB permanent magnets with a temperature resistance of 130°C
and no demagnetisation, these fans provide a maintenance-free and long-lasting motor. The blades are crafted from polymer composite material and designed with a high lift resistance ratio aviation airfoil. The wingtip technology effectively reduces air vortex movement, minimising energy loss caused by vortex. This range features 15
innovative safety designs to ensure the safe operation of the fans.

Features: · Highly efficient and energy-saving · Permanent magnet brushless motor for
maintenance-free and long-lasting operation · Polymer composite blades with high lift
resistance ratio aviation airfoil
· Wingtip technology reduces air vortex
movement for minimal energy loss
· 15 innovative safety designs for safe operation

Applications: · Warehouse, Workshops & Factories · Agriculture
· Construction sites
· Sports Facilities

SPECIFICATIONS

Diameter

Model No

m

HVLS25

3

HVLS40

4

HVLS49

4.9

HVLS73

7.3

RPM Power W

120

150

95

420

85

720

56

1250

Voltage
220~240 220~240 220~240 220~240

Air Volume

l/s 60,000 125,000 175,000 296,666

m³/min 3,600 7,500 10,500 17,800

Coverage Optimum use area m²

m²

Air Velocity  1m/s

225

56

550

220

700

360

1375

840

Main Fan Weight kg
31.5 47.8 54.5 83.6

13

INSTALLED/FIXED

FANMASTER
cooling heating ventilation extraction

POWER TECHNOLOGY
· Efficient and Compact: Our permanent magnet external rotor motor offers high efficiency, energy savings, and a

compact, lightweight design · Dust Protection: Our patented labyrinth-type dust-proof

structure prevents dust from entering the motor core,
ensuring optimal performance · Enhanced Cooling: Our patented motor core heat

FANMASTER
cooling heating ventilation extraction

dissipation system maintains low temperatures for extended service life

BLADE TECHNOLOGY
· Advanced Aerodynamics: Our blades feature a high lift-

resistance ratio aviation airfoil design for optimal performance
· Durability: Constructed from high-strength, lightweight
materials, our blades are impact-resistant, anti-aging, and built
to last · Noise Reduction: Our patented wingtip guide plate minimises air turbulence, reducing noise levels and improving efficiency

SAFETY TECHNOLOGY
· Comprehensive Protection: Our fan incorporates 12 major

safety features for your peace of mind · Structural Integrity: Reinforced steel beam locking and hanger

safety cables ensure secure installation · Motor Protection: Motor shaft brackets and anti-drop

structures safeguard against damage · Internal Safety: Step locks and permanent magnet self-locking

mechanisms prevent accidental movement · Blade Security: Reinforced blade mounting brackets and safety link mechanisms enhance durability · Electrical Safety: Our control system includes overload

protection for added reliability

· High-Strength Components: Grade 12.9 fasteners and anti-

loosening measures provide lasting performance · Impact-Resistant Blades: Non-metal polymer composite
blades are resistant to damage

CONTROL TECHNOLOGY

· Advanced Control: Developed in partnership with a leading frequency converter manufacturer, our control system offers

superior performance

· Comprehensive Protection: Safeguard your investment

with overcurrent, overvoltage, undervoltage, and overload

protection · Smooth Operation: Enjoy a seamless start, acceleration,

deceleration, and stop, minimising vibration and noise

WINGTIP TECHNOLOGY
· Enhanced Efficiency: Patented wingtip guide plate minimises air turbulence at the blade's edge · Reduced Energy Loss: This reduces energy waste, leading to improved efficiency and lower operating costs · Quieter Operation: The optimised airflow also results in a quieter, more comfortable environment
14

COOLING
What is Air Circulation?
Air circulation is the movement of air in a room or building. It is important for maintaining good indoor air quality and comfort. Air circulation helps to:
· Remove stale air and pollutants from the air · Distribute heat or cool air evenly throughout the room · Prevent the buildup of moisture and mould · Create a more comfortable environment

COMMERCIAL FANS

ICF450W

FANMASTER
cooling heating ventilation extraction

Features:
· Commercial 450mm air circulating fan · Quiet, stylish and effective · 3 Speeds
· 90° & Fixed oscillation
· Vertically adjustable
· Pull cord switch for ease & safety

SPECIFICATIONS
Diameter Motor Voltage
Maximum Air Flow Current
Plug Connection Fan Speed Weight Type STAGE 1 Noise STAGE 2 Noise STAGE 3 Noise

UNIT mm W L/S
kg
dB dB dB

ICF450W 450 130 240 1910 0.54
3 Pin 10A 3 9
Wall
48
50
56

Applications: · Warehouse, Factories & Workshops · Offices · Shops
· Lunchrooms
· Gymnasiums
· Garages · Outdoor entertaining areas

15

INSTALLED/FIXED

INDUSTRIAL WALL FANS

IFW500, IFW600, IFW650, IFW750, IFW850

Designed to Perform & Last!
The Fanmaster Premium Fans are manufactured to the highest quality. These Industrial Fans have been sold for over 24 years in the Australian market. This is the most comprehensive range on the market from floor, wall & pedestal fans, with sizes from 500mm to 850mm.

Features: · Premium quality fans · Full range of sizes to suit any application · 3 speeds · 90° adjustable oscillation · Low wattage means cheaper running costs · Pull cord switch for ease & safety · Quick release clips on guards for easy cleaning
Applications: · Warehouse, Factories & Workshops · Offices · Shops · Lunchrooms · Gymnasiums · Garages · Outdoor entertaining areas

SPECIFICATIONS
Diameter Motor
Plug Connection
Maximum Air Flow Weight STAGE 1 Power Speed Noise Air Flow STAGE 2 Power Speed Noise Air Flow STAGE 3 Power Speed Noise Air Flow

UNIT mm W
L/S kg
w rpm dB L/S
w rpm dB L/S
w rpm dB L/S

IFW500 500 130 3 Pin 10A 2166 14
97 1100 48 1583
106 1250 50 1933
130 1400 55 2166

IFW600 600 170 3 Pin 10A 3250 15
120 1100 52 2083
130 1250 56 2500
170 1400 62 3250

IFW650 650 210 3 Pin 10A 3833 16
148 925 45 2383
175 1250 55 2833
210 1400 68 3833

IFW750 750 240 3 Pin 10A 5033 17
175 1100 58 3566
195 1250 70 4500
240 1400 75 5033

IFW850 850 350 3 Pin 10A 6500 19
255 1100 68 4250
283 1250 82 5333
350 1400 88 6500

16

COOLING

PORTABLE EVAPORATIVE COOLERS PAC125-ADC

Features: · Efficient and durable spot cooler · Digital LCD control panel with remote control for
easy use
· Air supply distance up to 8m
· Automatic swing louvre function
· DC motor
· Low power consumption · 3 cooling pads with pre filters for dust · Wheels with brake function

Applications: · Warehouse, Workshops & Factories
· Agriculture
· Construction sites
· Events & military · Rental & Emergency

SPECIFICATIONS
Air Flow Fan Type Noise Level
Motor Voltage/Frequency
Current Plug Connection
Cooling Area Air Supply Distance
Tank Capacity Water Consumption
Fan Speed Cooling Pad Size Cooling Pad Thickness Material of Blades Material of Body
Weight Product Dimensions (L*D*H)
Pack Dimensions

UNIT L/S
dBa kW
A
m² m L L/H
mm mm
kg mm mm

PAC125-ADC
1,111 Axial <61 0.125 220~240/50 0.78 3 Pin 10A up to 30
8 40 3-8 9 580*225 40
PP body + tank 16.5 / 19
580*375*1050 590*390*1000

PORTABLE EVAPORATIVE COOLERS PAC280-A
Features: · Efficient and durable spot cooler · Digital LCD control panel with remote control
for easy use · Air supply distance up to 11m · Automatic swing louvre function · Large water tank for longer operation · Low power consumption · 3 large cooling pads with pre filters for dust · Heavy duty wheels with brake function · Connect to standard garden hose connection
for continuous water supply

SPECIFICATIONS
Air Flow Fan Type Noise Level
Motor Voltage/Frequency
Current Plug Connection
Cooling Area Air Supply Distance
Tank Capacity Water Consumption
Fan Speed Cooling Pad Size - side/back Cooling Pad Thickness - side/back
Material of Blades Material of Body
Weight Product Dimensions (L*D*H)
Pack Dimensions

UNIT L/S
dBa kW
A
m² m L L/H
mm mm
kg mm mm

17

Applications: · Warehouse, Workshops & Factories · Agriculture · Construction sites · Events & military · Rental & Emergency
WATCH ME
PAC280-A 2,111 Axial <63 0.28
220~240/50 1.3
3 Pin 10A up to 50
11 120 10 3 698*230 / 700*770 55 / 75 Nylon PP body + tank 38 / 43 910*490*1380 920*490*1280

PORTABLE

FANMASTER
cooling heating ventilation extraction

PORTABLE EVAPORATIVE COOLERS PACISD - SINGLE DIRECTIONAL

194cm AVAILABLE IN DIY KITS - PACISD-PA

Features: · Efficient and durable spot cooler · Digital LCD control panel with remote control
for easy use
· Air supply distance up to 28m
· Automatic swing louvre function · Large water tank for longer operation · Low power consumption · 4 large cooling pads with pre filters for dust · Heavy duty wheels with brake function · Connect to standard garden hose connection
for continuous water supply

SPECIFICATIONS
Air Flow Fan Type Noise Level
Motor Voltage/Frequency
Current Plug Connection
Cooling Area Air Supply Distance
Tank Capacity Water Consumption
Fan Speed Cooling Pad Size Cooling Pad Thickness Material of Blades Material of Body
Weight Product Dimensions (L*D*H)
Pack Dimensions

UNIT L/S
dBa kW
A
m² m L L/H
mm mm
kg mm mm

PORTABLE EVAPORATIVE COOLERS PACIMD - MULTI DIRECTIONAL

Applications: · Warehouse, Workshops & Factories · Agriculture · Construction sites · Events & military · Rental & Emergency
WATCH ME
PACISD 5,000 Axial <68 1.1 220~240/50 7.5 3 Pin 10A up to 150
28 300 15 Variable 700*770 100 ABS PP body + Galvanised Steel Tank 98/120 1080*1080*1940 1080*1080*2150

164cm AVAILABLE IN DIY KITS - PACIMD-PA

Features: · Efficient and durable spot cooler · Digital LCD control panel with remote control for
easy use
· 8 x air outlets
· Adjustable swing louvres · Large water tank for longer operation · Low power consumption · 4 large cooling pads with pre filters for dust · Heavy duty wheels with brake function · Connect to standard garden hose connection for
continuous water supply

Applications: · Warehouse, Workshops & Factories · Agriculture · Construction sites · Events & military · Rental & Emergency
WATCH ME

SPECIFICATIONS
Air Flow Fan Type Noise Level
Motor Voltage/Frequency
Current Plug Connection
Cooling Area Air Supply Distance
Tank Capacity Water Consumption
Fan Speed Cooling Pad Size Cooling Pad Thickness Material of Blades Material of Body
Weight Product Dimensions (L*D*H)
Pack Dimensions

UNIT L/S
dBa kW
A
m² m L L/H
mm mm
kg mm mm

PACIMD
5,000 Axial <68 1.1 220~240/50 7.5 3 Pin 10A up to 150 4 per air outlet (8) 300 15 Variable 700*770 100 ABS PP body + Galvanised Steel Tank 89/110 1080*1080*1640 1080*1080*1800

18

COOLING
What is a Portable Air Conditioner?
A portable air conditioner is a completely self-contained refrigerated air conditioning system housed within a heavy duty insulated cabinet on wheels. Ideal for applications where an installed system is not viable and for emergency and breakdown applications.
How does it work?
A portable air conditioner works by using refrigerant to absorb heat from the air in a room and then expelling the heat outside. The refrigerant is a special fluid that can change from a liquid to a gas and back again. When the refrigerant is a liquid, it absorbs heat. When the refrigerant is a gas, it releases heat.

PORTABLE AIR CONDITIONERS

IAC-27, IAC-45, IAC-65

FANMASTER

Features: · Spot cooling in a variety of commercial &

cooling heating ventilation extraction

industrial applications

· Heavy duty self-contained housing · Easy to use on/off switch

· Adjustable cooling arms · Easy to remove condenser tank

· Exhaust duct standard to direct hot air away · Cleanses and dehumidifies the air

· Compact and easy to move · Heavy duty wheels with brake function

Applications: · Warehouses, Workshops & Factories
· Commercial Kitchens
· Hospitals & Laboratories · Emergency Cooling & Server Rooms · Multi workstations
· Marquee events · Temporary office cooling
· Equipment spot cooling

SPECIFICATIONS

UNIT

IAC-27

IAC-45

IAC-65

Max Air Flow

L/S

111

222

333

Cooling Capacity Kw / BTU

2.7 / 9,200

4.5 / 15,300

6.5 / 22,000

Noise Level

dBa

Rated Power

kW

Voltage/Frequency

55 0.95 220~240V/50Hz

60 2 220~240V/50Hz

65 3.3 220~240V/50Hz

Current

A

4.2

9.0

13.5

Plug Connection Refrigerant
Refrigerant Charge No. Of Cool Air Duct

3 Pin 10A R410A
460 grams (+/-10g) 1

3 Pin 15A R410A
800 grams (+/-10g) 3

3 Pin 15A R410A
1050 grams (+/-10g) 3

Cooling Duct Diameter mm

120

120

120

Exhaust Duct Diameter

mm

160

200

250

Fan Speed

2

Condensation Tank

L

55

Weight

kg N/G

5

2

2

60

65

8

13

Product Dimensions

mm

42 / 47

70 / 75

94 / 150

Pack Dimensions

mm

(W)405x(D)430x(H)855

(W)520x(D)480x(H)1035 (W)630x(D)560x(H)1245

Pack Dimensions 1

mm

(W)484 x (D)515 x (H)965

(W)570x(D)610x(H)1110

(W)720x(D)650x(H)1350

19

Pack Dimensions 2

mm

(W)260x(D)350x(H)370

(W)380x(D)280x(H)515

PORTABLE

FANMASTER
cooling heating ventilation extraction

PORTABLE AIR CONDITIONERS

IPAC-47, IPAC-61, IPAC-94
Features: · Premium cooling solution · Spot & Room mode cooling (dedicated
thermostat controls) · Room mode cools up to 100m² · Heavy duty self-contained housing · Easy to use LCD control panel · Adjustable cooling arms · Easy to remove condenser tank · Cleanses and dehumidifies the air · Self-diagnostic system · Heavy duty wheels with brake function

Applications: · Warehouses, Workshops & Factories
· Commercial Kitchens
· Hospitals & Laboratories · Emergency Cooling & Server Rooms · Multi workstations
· Marquee events · Temporary office cooling
· Equipment spot cooling · Military use - tents, aircraft hangars

WATCH ME IPAC-47

WATCH ME IPAC-61

WATCH ME IPAC-94

SPECIFICATIONS

UNIT

IPAC-47

IPAC-61

IPAC-94

Air Flow Cooling Capacity Power Consumption Voltage/Frequency
Current Plug Connection
Refrigerant Refrigerant Charge EERR(aEtnioe)rBgTyUE/ffWichient CoolingMAordeea)(Room No. Of Cool Air Duct
Fan Speed Weight
Dimensions Cable Length Country of Manufacture

L/S Kw / BTU
kW A
m2
kg mm m m

189/222 4.7 / 16,000
1.7 220~240V/50Hz
7.5 3 Pin 10A
R410A 950 grams (+/-10g)
9.8
40
2 2 86 (W)523x(D)671x(H)1042 3 South Korea

219/264 6.1 / 21,000
2.1 220~240V/50Hz
9.5 3 Pin 15A
R410A 1050 grams (+/-10g)
-
50
2 2 88 (W)523x(D)671x(H)1042 3 South Korea

366/416 9.4 / 32,000
3.3 220~240V/50Hz
16.5 *Fixed Wiring
R410A 1500 grams (+/-10g)
10.6
100
3 2 110 (W)660x(D)885x(H)1380 3 South Korea

* Fixed wiring - a qualified electrician is required to do any fixed wiring work for this appliance

PORTABLE AIR CONDITIONER (REVERSE CYCLE)

IPHC-35
Features: · Perfect all year round solution · Cooling, Heating & Auto Modes · 4kW Cooling capacity · 4.3kW Heating capacity · Self-diagnostic function · 6 Speeds · 143 L/s Airflow · 32m² cooling area · Heavy duty self-contained housing · Easy to use LCD control panel · Easy to remove condenser tank · Heavy duty wheels with brake function
Applications: · Warehouses Workshops Factories · Agricultural · Hospitality · Offices · Showrooms · Events (tents/marquees)

SPECIFICATIONS
Capacity Cooling Heating
Air Flow
Power Consumption Cooling Heating
Voltage/Frequency
Current Cooling Heating
Plug Connection Refrigerant
Refrigerant Charge EER (Energy Efficient
Ratio) Air Grill
Fan Speed Condensation Tank
Cooling Area
Product Dimensions Pack Dimensions Weight

UNIT Kw / BTU
L/S kW
A
BTU/Wh
L m2 mm mm kg

IPHC-35
4 / 13,600 4.3 / 14,800
143
1.58 1.41
7 6.36 3 Pin 10A R410A 1,100g
11
1 6 12 32 523x670x1044 545x695x1110 86

20

FANMASTER
cooling heating ventilation extraction
More than fans
While people often know us best for our cooling solutions (the "Fanmaster" name does give it away), we also offer a whole range of ventilation and extraction equipment that's perfect for commercial and industrial settings.
Get In Touch
Address
Unit 1/6-8 Yalgar Rd, Kirrawee NSW 2232
Email
sales@fanmaster.com.au
Phone
1300 900 345
Website
www.fanmaster.com.au



References