Trane YSC120H3RHA0000 Packaged Gas/Electric HVAC

This document provides a detailed parts list and component breakdown for the Trane YSC120H3RHA0000 packaged gas/electric HVAC unit.

Top Level Overview

Illustration of the packaged gas/electric unit with key components labeled.

Components:

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Main Component List

Part No. Reference No. Quantity Description
7501246011INTERIOR SHEET METAL
7501172111UNIT BASE COMPONENTS
7501224321BLOWER-INDOOR, PLENUM FAN & TCO2
7501261331FAN - OUTDOOR
7501274341CONTROL PANEL
7501185141HARNESS - COMMON CONTROLS
7501185541TERMINAL BLOCK - CONTROLS (CTB)
7501266661OUTDOOR COIL, COMPRESSORS
7501243571BURNERS, GAS VALVE, INDUCER, FD,FR, IP, TCO
7501246571HEAT EXCHANGER
7501266781INDOOR COIL, DRAIN PAN, TXVS, FILTERS
NGRAPHIC101OPTIONAL FIELD INSTALLED ACCESSORIES
75012766111MODEL NUMBER DESCRIPTION, DIGITS 1-16
75012767111MODEL NUMBER DESCRIPTION, DIGITS 17-31

Interior Sheet Metal

Illustration of interior sheet metal components.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
PNL2679411PANEL; INDOOR FAN BLOCKOFF, 24.56 X 19.50
BUS0033821BUSHING; SNAP, 2.00 INCH OD X 1.63 ID, MAX PANEL THICKNESS 0.125, BLACK NYLON
PNL2673031PANEL; TOP WRAPPER, HEAT EXCHANGER, 19.59 X 12.11

Unit Base Components

Illustration of unit base components. Note: Unit Base Pan not available - not recommended as a replaceable part.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
PLT0361911PLATE; MOUNTING, COMPRESSOR, 34.56 X 14.30
RAL0087831RAIL; END, 53 IN LENGTH
CLP0100844NO DESCRIPTION AVAILABLE
SUP0448651SUPPORT; INDOOR COIL, 51.6 INCH LENGTH
BRK0327561BRACKET; COMPRESSOR SUPPORT (3 SIDES)
ANG0132471ANGLE; TOGGLE LOCK, 51.00 X 1.80
RAL0121181RAIL; BASE, C/D CABINET
BRK0327494BRACKET; BASE SUPPORT MOUNT, 10.3 LENGTH (FORKLIFT BRACKET)

Blower - Indoor, Plenum Fan & TCO2

Illustration of the indoor blower, plenum fan, and TCO2 components.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
SCR01421*6SCREW; M10 X 25
SCR01557*16SCREW; SHEET METAL 0.25-14 X 0.62, HEX HEAD, SLATE GRAY COLOR
WAS00622*6WASHER;10MM ID X 18.1 OD
FAN0549211FAN; ASSEMBLY; INDOOR PLENUM FAN; 200-240V
MOD0278821MODULE; ELECTRONICS, ATTACHES TO EBM MOTOR ASSEMBLY, 230V, INCLUDES WIR05194
CON0010531CONNECTOR; HOUSING; 12 CKT SOCKET HSG MALE
CON0048631CONNECTOR; PLUG HOUSING, 3 PIN MALE
WIR0519431WIRE; HARNESS, INDOOR FAN MOTOR (1Z,2S,3S,GND,37B,39B,40B,41B,45B,108C,158E)
WIR0870341WIRE; HARNESS, LED, WITH BRACKET
CNT0351151CONTROL; LIMIT, 120F, AUTOMATIC RESET, SPST, NC, 15A/120VAC, 10A/240VAC, QC TERMINAL

Fan - Outdoor

Illustration of the outdoor fan assembly, including motor, blade, grille, and hardware.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
GRL0135311GRILLE; OUTDOOR FAN, 30.33 MTG DIA
NUT0133224NUT; SERRATED HEX FLANGE, ZINC PLATED (IF RUBBER CAP IS NEEDED ORDER IRT00017)
RNG0100532RING; EXTRUDED FIN, HEAT SINK, 3.00 WIDE, UNRESTRAINED DIM IS 7.20/6.61
MOT1864641MOTOR; AL OD MOTOR, 3 PHASE 0.7 HP, 230V
FAN0609151FAN; BLADE, OD FAN - 26X4XH28/L30 - DUAL SET-SCREW
NUT0000961NUT; .25-20, HEX LOCK
WAS0067071WASHER; .26 ID X .49 OD
WAS0004181WASHER; FLAT, PLAIN, #12 .25 ID X .56 OD, .065 THK, CARBON STL-PLD
BRK0068892BRACKET; CONNECTING, HEAT SINK

Terminal Block - Controls (CTB)

Illustration of the terminal block for controls, which is a component of the Common Controls Harness.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
CAP0125112CAP; PROTECTIVE FORM CAP
TER0133222TERMINAL; BLOCK, END STOP
PLT0405131PLATE; 4 CONDUCTOR POLE END PLATE
TER0133443TERMINAL; BLOCK, 4 CONDUCTOR POLE 20A 600V
TER0135151TERMINAL; BLOCK, POLE MARKING 1-10 VERT
TER0135461TERMINAL; BLOCK, 3 POLE JUMPER

Harness - Common Controls

Illustration of the common controls harness, showing wiring and connections.

Part No. Reference No. Quantity Description
WIR0926311WIRE; HARNESS, COMMON CONTROLS, INCLUDES CTB
TER0168021TERMINAL STRIP; .25IN. FASTON
BLK0094031BLOCK; 6 TERMINALS (LVTB)
BRK0444141BRACKET; OUTDOOR AIR SENSOR
GRM0003941GROMMET; RUBBER .25 ID X .05 GRV MLD
SEN0182941SENSOR; THERMISTOR PROBE, -40 TO 65C, .25 DIA X 1.75 LG W/26" PVC LEADS-INSUL QC

Control Panel

Illustration of the control panel with various electronic modules, contactors, and wiring connections.

Note: The parts that appear on this illustration are for all options. Parts will appear in the Parts List if factory installed. This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
WIR09230*1WIRE; HARNESS; C/D CAB, CNTLS, DUAL COMPRESSOR, EBM MOTOR
WIR09231*1WIRE; HARNESS; C/D CAB, CNTLS, GAS
WIR09236*1WIRE; HARNESS; C/D CAB, PWR & CNTLS, EBM PLENUM MTR, CONSTANT VOLUME
WIR09240*1WIRE; HARNESS; C/D CAB, PWR, DUAL COMP, W/O INDOOR MOTOR XFMR, INCLUDES CCHTB
CTR0120311CONTACTOR; 2P, 30A, 24V COIL, 30 FLA AT 277V
CNT0140521CONTROL; TEMP, OPEN 65F, CLOSE 55F, SPST
CON0007741CONNECTOR, ELECTRIC GROUND, 14-2 AWG SOLDERLESS
CTR0187051CONTACTOR; 3 POLE, 30 FLA, W/O LUGS, 50/60 HZ, 24V COIL
CTR0187061CONTACTOR; 3 POLE, 30 FLA, W/O LUGS, 50/60 HZ, 24V COIL
BUS0033871BUSHING; SNAP, 2.00 INCH OD X 1.63 ID, MAX PANEL THICKNESS 0.125, BLACK NYLON
CAT0004382CATCH; MAGNETIC SNAP-IN
WIR03277101WIRE; HARNESS, OPTION MODULE GENDER CHANGER. BK, BL, RD WIRES. 4 INCH LENGTH. PPM33
BLK00940111BLOCK; 6 TERMINALS (LVTB)
MOD02554131MODULE; RELIATEL OPTIONS, RTOM
MOD02811141MODULE; RELIATEL REFRIGERATION DUAL CIRCUIT COOL/HP
BRK04176161BRACKET; IGNITION MODULE, 6.56 X 5.00 X 0.38
MOD01298161MODULE; RELIA TEL GAS DUAL STAGE W/CHASSIS GROUND
TER01680181TERMINAL STRIP; .25IN. FASTON
WIR03278191WIRE; HARNESS, SUPPLY AIR TEMPERING, BK WIRE, 3 INCHES LENGTH, RTOM 5J3-1 TO 5J3-2
CNT05176201CONTROL; MONITOR, 3-PHASE LINE, UNIVERSAL 180-632 VAC, PHASE AND LOSS REVERSAL
TRR00825211TRANSFORMER; 75 VA, 208-230V PRI, 24V SEC

Outdoor Coil, Compressors

Illustration of the outdoor coil and compressor assembly.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
WIR03437*1WIRE; HARNESS, COMPRESSOR, 14 AWG, CC1, 46 IN LENGTH (3 WIRE-RK,BL,BK)
WIR03439*1WIRE; HARNESS, COMPRESSOR, 14 AWG, CC2, 62 IN LENGTH (3 WIRE-RK,BL,BK)
RTR0099024CLIP; MICROCHANNEL COIL MOUNTING
SUP0605131SUPPORT; REAR, BETWEEN UNIT BASE AND COIL, POLYPROPYLENE, 24.96 X 2.83
CAP0007241CAP; VALVE, SEAL, .25 FFL
SET0081941SEAT; SADDLE MOUNT ASSEMBLY
STM0080341STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)
SWT0340251SWITCH; HIGH PRESSURE, BRAZED, OPENS AT 650 PSIG, CLOSES AT 550 PSIG, 61 INCH WHITE LEADS
CAP0007261CAP; VALVE, SEAL, .25 FFL
SET0081961SEAT; SADDLE MOUNT ASSEMBLY
STM0080361STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)
THT0276071THERMOSTAT; WITH CLIP, .5/.625 TUBE, 72" BLACK WIRES, SPST, 230F OPEN, 180F CLOSE
SWT0362381SWITCH; LOW PRESSURE CUTOUT, 250 OPEN, ACTUATION PRESSURE 55 +/- 5, RESET PRESSURE 35 +/- 5
WIR0440681WIRE; HARNESS, LOW PRESSURE SWITCH, 42 IN LENGTH, BLUE WIRES, CIR 1
CAP0007291CAP; VALVE, SEAL, .25 FFL
SET0081991SEAT; SADDLE MOUNT ASSEMBLY
STM0080391STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)
COM10212101COMPRESSOR; SCROLL, SXA061B3BPZ, 5.0 ΤΟΝ, 200-230/60/3, R410A
ISR00007118ISOLATOR; VIBRATION
NUT00355118NUT; HEX, LOCK, 5/16IN.-18
HTR06511121HEATER; CRANKCASE, 70W, 230V, 6.5 DIA, 65/46 IN LEAD LENGTHS
CAP00072131CAP; VALVE, SEAL, .25 FFL
COR00006131CORE; VALVE PORT, .79 LENGTH, 206-36 UNS 2A THD
VAL01483131VALVE; BODY, .44-20 THD X .25 ODS, STRAIGHT, BRASS, LESS CORE
HTR03908141HEATER; CRANKCASE, 40W, 230V, 6.5 DIA, 70 IN LEAD LENGTHS
CAP00072151CAP; VALVE, SEAL, .25 FFL
COR00006151CORE; VALVE PORT, .79 LENGTH, 206-36 UNS 2A THD
VAL01483151VALVE; BODY, .44-20 THD X .25 ODS, STRAIGHT, BRASS, LESS CORE
COM10069161COMPRESSOR; SCROLL, SXA039B3BPZ, 3.25 ΤΟΝ, 200-230/60/3, R410A
DHY01511172DRIER; FILTER, LIQUID LINE, 5/16 ODM INLET X 5/16 ODF OUTLET, 8 CU INCH
SWT03173181SWITCH; LOW PRESSURE CUTOUT, 250 OPEN, ACTUATION PRESSURE 41 +/- 4, RESET PRESSURE 25 +/- 4
WIR04407181WIRE; HARNESS, LOW PRESSURE SWITCH, 55 IN LENGTH, YELLOW WIRES, CIR 2
CLP01073192CLIP; BULB (RED)
THT02761201THERMOSTAT; WITH CLIP, .5/.625 TUBE, 72" RED WIRES, SPST, 230F OPEN, 180F CLOSE
SWT03403211SWITCH; HIGH PRESSURE, BRAZED, OPENS AT 650 PSIG, CLOSES AT 550 PSIG, 61 INCH ORANGE LEADS
CAP00072221CAP; VALVE, SEAL, .25 FFL
SET00819221SEAT; SADDLE MOUNT ASSEMBLY
STM00803221STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)

Heat Exchanger

Illustration of the heat exchanger assembly, including the main exchanger, plug, orifice, and insulation.

Note: All parts are included with [1], except the TCO1 Plug [2]. This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
TRB00119*5TURBULATOR; INLET, 12 INCH, INCLUDES WIR04279 WIRE SUPPORT
EXC0221111EXCHANGER; HEAT
PLU0129421PLUG; GAS HEAT TC01
ORF0142441ORIFICE; AIR, 2.9 INCH, ALUMINUM
WEL0084851WELL; BULB, TAP, STATIC, 1.0 LENGTH X 0.50 OD X 0.281 OD X 0.125 ID
CLP0094061CLIP; STATIC, RETAINER, .80 X .56 X .022
INS0277771INSULATION; COLLECTOR COVER, 18.75 X 13.48 X 0.34, ALUMINUM/SILICONE
GKT0392681GASKET; HEAT EXCHANGER VESTIBULE, FIBERGLASS REINFORCED, 19.69 X .125
ROD0113791ROD; SUPPORT, 20 INCHES

Burner, Gas Valve, Inducer, FD, FR, IP, TCO

Illustration of the burner assembly, including gas valve, inducer, and related components.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
CNT03787*1CONTROL; LIMIT, 260F, AUTOMATIC RESET, SPST, NC, 15A/120VAC, 10A/240VAC, QC TERMINAL
WIR08872*1WIRE; HARNESS, GAS VALVE ADAPTER, BR,BL,BR WIRES, 5 INCH LENGTH, 3 PIN CONNECTOR
MFD0099511MANIFOLD; GAS, 3/4/X 5 BURNER
VAL0875021VALVE; GAS, NATURAL, 2 STAGE, 24 VAC, 50/60 HZ, .4 AMP REDUNDANT, INLET OUTLET 3/4 X 3/4-14 NPT, MAX OP PRESSURE .5 PSIG
ELL0003031ELBOW; .75, 90 DEG ST, 150# MI
CNT0366641CONTROL; DIFFERENTIAL PRESSURE SWITCH, ROTATED 180 DEG, SPST, SNAP ACTING CONTACTS, NO, 5 AMP RESISTIVE AT 24 VAC
TUB1050651TUBE; CONNECTING PRESSURE, SILICON RUBBER, .19 ID X .06W, 12.50 IN
CLP0094062CLIP; STATIC, RETAINER, .80 X .56 X .022
WEL0084871WELL; BULB, TAP, STATIC, 1.0 LENGTH X 0.50 OD X 0.281 OD X 0.125 ID
FAN0421681FAN; 2 SPEED COMBUSTION AIR BLOWER, 1/15 HP MOTOR, 208-230/50-60/1, 2800/3350 RPM, .50/.42 AMPS, WHEEL SIZE 4.72 DIA OD
DUC0104091DUCT; FLUE EXHAUST, ALUMINUM COATED WELDED STEEL TUBING
GKT03850101GASKET; COMBUSTION BLOWER
CNT04671111CONTROL; LIMIT, 190F, AUTOMATIC RESET, SPST, NC, 15A/120VAC, 10A/240VAC, QC TERMINAL
IGN00114121IGNITOR; ELECTRODE, 57 IN LEAD
BRK04324131BRACKET; IGNITOR AND FLAME SENSOR, 15.3 X 1.1
SEN00297141SENSOR; FLAME
SWT02649151SWITCH; FLAME ROLLOUT, 240F, OPENS ON TEMP RISE, MANUAL RESET, SPST, 25A/240V QC TERMINAL
BRK04320161BRACKET; GAS 5-BURNER SUPPORT, 8.50 X 2.53 X 15.16
BNR01071175BURNER; 0.60 ID INSHOT BURNER, 0.036 THK 304 STAINLESS STEEL
ORF01342185ORIFICE; GAS, SPUD, 3.3 MM DIA

Indoor Coil, Drain Pan, TXVs, Filters

Illustration of the indoor coil, drain pan, and associated components like TXVs and filters.

Note: This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No. Reference No. Quantity Description
DST00945*1DISTRIBUTOR; ASSEMBLY, INDOOR, 12 OUTLETS, #4 NOZZLE
DST00946*1DISTRIBUTOR; ASSEMBLY, 8 OUTLETS, #2.5 NOZZLE
COL1812211COIL; INDOOR, 4 ROW, 40H X 44.5L
BRK0309721BRACKET; FILTER STOP, 40.00 X 3.00
BOF0231141BLOCKOFF; INDOOR COIL BOTTOM, 51.44 X 2.65 X 2.15
BRK0323451BRACKET; INDOOR COIL, BOTTOM, 0.65 X 4.39 X 1.50
VAL1037371VALVE; EXPANSION, 6 ΤΟΝ, 3/8 ODF IN X 1/2 ODF OUT, NON-ADJUSTABLE, R410A, 127.0 PSIG
VAL1037181VALVE; EXPANSION, 4 ΤΟΝ, 3/8 ODF IN X 1/2 ODF OUT, NON-ADJUSTABLE, R410A, 124.8 PSIG
BRK0393891BRACKET; FILTER CHANNEL, 50.50 LENGTH
BOF01684101BLOCKOFF; INDOOR COIL, FRONT, 40.6 X 5.5

Optional Field Installed Accessories

Part No. Reference No. Quantity Description
ASYSTAT712B*1SENSOR; CO2 SENSING KIT; WALL MOUNTED (ASYSTAT712B)
ASYSTAT714B*1SENSOR; CO2 SENSING KIT; DUCT MOUNTED (ASYSTAT714B)
BAYABRD001C*1KIT; ACCESSORY, OPTIONS BOARD (BAYABRD001CA)
BAYBARM011A*1DAMPER; BAROMETRIC RELIEF (BAYBARM011AB)
BAYBCIR001A*1KIT; FIELD INSTALLED BCI (BAYBCIR001A)
BAYCO2K101A*1KIT; WALL MOUNT CO2 SENSOR KIT
BAYCO2K103A*1KIT; DUCT MOUNT CO2 SENSOR KIT
BAYCURB043A*1CURB; ROOFCURB (BAYCURB043AB)
BAYDFPS004A*1KIT; FAN FAILURE SWITCH (BAYDFPS004AB). (OPTIONS BOARD KIT09433-BAYABRD001CA MUST BE INSTALLED IN THE UNIT FOR THIS ACCESSORY TO OPERATE).
BAYDMPR054A*1DAMPER; RELIATEL, 0-50 PERCENT MOTORIZED OUTSIDE AIR DAMPER (BAYDMPR054A)
BAYDMPR056B*1DAMPER; 0-50% MANUAL OUTSIDE AIR DAMPER (BAYDMPR056BA)
BAYECON087A*1ECONOMIZER; RELIATEL, 0-100 PERCENT DRY BULB (BAYECON087A)
BAYECON704A*1ACCESSORY; LOW LEAK ECONOMIZER, FOR C/D/E CABINETS WITH RELIATEL CONTROLS (SEE ACC-SVN177* FOR MODELS)
BAYENTH005A*1KIT; REFERENCE ENTHALPY (BAYENTH005A)
BAYENTH006B*1KIT; COMPARATIVE ENTHALPY (BAYENTH006B)
BAYHAKT010E*1KIT; ACCESSORY, HIGH ALTITUDE
BAYHSDR012A*1KIT; HIGH STATIC DRIVE (BAYHSDR012AA)
BAYICSI003A*1BOARD; ACCESSORY, RELIATEL COMMUNICATIONS INTERFACE BOARD (BAYICSI003AD)
BAYLOAM020B*1CONTROL; EVAPORATOR DEFROST KIT (FROSTAT) (BAYLOAM020BB). (OPTIONS BOARD KIT09433-BAYABRD001CA MUST BE INSTALLED IN THE UNIT FOR THIS ACCESSORY TO OPE
BAYLPKT029C*1KIT; LP CONVERSION (BAYLPKT029C)
BAYLTCI002B*1KIT; RELIATEL COMMUNICATIONS INTERFACE THAT INCORPORATES LONTALK PROTOCAL (BAYLTCI002BB)
BAYPWRX026A*1KIT; POWER EXHAUST, 208/230V (BAYPWRX026A)
BAYQACB011A*1CURB; ADAPTA CURB (BAYQACB011AA), TRANSITIONS BAYCURB022B, 83.50 X 49.375
BAYQACB012A*1CURB; ADAPTA CURB (BAYQACB012AA), TRANSITIONS BAYCURB025B, 90.50 X 60.625
BAYQACB013A*1CURB; ADAPTA CURB (BAYQACB013AA), TRANSITIONS BAYCURB026B, 103.375 X 68.125
BAYQACB114A*1QUICK ADAPTER ROOF CURB
BAYRTEM001A*1RELIATEL ECONOMIZER LOGIC MODULE
BAYSENS050A*1WIRELESS ZONE SENSOR
BAYSENS250A*1CO2 SENSOR
BAYSENS251A*1SENSOR; CO2 WALL MOUNT (BAYSENS251A)
BAYSENS924A*1SENSOR, TOUCH SCREEN, PROGRAMMABLE SPACE, RELIATEL
BAYSTAT023A*1RESISTOR; REMOTE POTENTIOMETER
BAYTUBE400A*1DISCHARGE AIR SENSING KIT; GAS HEAT
BAYVNOR001B*1KIT; VENTILATION OVERIDE (BAYVNOR001BB) (OPTIONS BOARD KIT09433-BAYABRD001CA MUST BE INSTALLED IN THE UNIT FOR THIS ACCESSORY TO OPERATE).
PLT04561*1PLATE; WALL COVER PLATE ASSEMBLY (BAYMTPL110A)
SEN00278*1SENSOR; THERMISTOR PROBE, -40 DEG C TO 65 DEG, STRIPPED LEADS (BAYSENS016AA)
SEN01447*1SENSOR; ZONE, ROOM SENSOR W/TEMP. ADJUSTMENT WITH OVERRIDE AND CANCEL BUTTONS, 10K, DIAL, OCCUPIED (BAYSENS074AA)
SEN01448*1SENSOR; ZONE, REMOTE ROOM SENSOR, 10K (BAYSENS077AA)
SEN01450*1SENSOR; ZONE, ROOM SENSOR W/ OVERRIDE AND CANCEL BUTTONS, 10K, OCCUPIED (BAYSENS073AA)
SEN01513*1SENSOR; ZONE; DUAL SETPOINT MANUAL OR AUTO CHANGOVER, TWO SET FAN SYSTEM (BAYSENS108AA)
SEN01515*1SENSOR;ZONE SINGLE SETPOINT MANUAL CHANGEOVER, SET FAN SYSTEM, COOL/OFF/HEAT (BAYSENS106A)
SEN01522*1SENSOR; ZONE, DUAL SETPOINT MANUAL OR AUTO CHANGEOVER W/SYSTEM FUNCTION LIGHTS TWO SET FAN SYSTEM, LED (BAYSENS110A)
SEN01577*1SENSOR; PROGRAMMABLE ZONE, AUTOMATIC OR MANUAL CHANGEOVER W/ SYSTEM LIGHTS TRANE (BAYSENS119AA)
SEN01665*1SENSOR; DUAL SETPOINT, W/FAN CONTROL - AUTO/HIGH (BAYSENS135A)
TOL00099*1TOOL; RESISTANCE DECADE BOX

Model Number Description

Digits 1-16

Example Model Number: YSC092H3RZA00C6C2A1A000DEA11AD1

Digit 1 Unit Type
D = Dual Fuel Heat Pump
T = DX Cooling
W = Packaged Heat Pump
Y = DX Cooling, Gas Heat
Digit 11 Minor Design Sequence
A = First Sequence
Digit 2 Efficiency
S = Standard Efficiency
H = High Efficiency
Digits 12, 13 - Service Sequence
** = Factory Assigned
Digit 3 Airflow
C = Convertible
Digit 14 Fresh Air Selection
0 = No Fresh Air
A = Manual Outside Air Damper 0-50%
B = Motorized Outside Air Damper 0-50%
C = Economizer, Dry Bulb 0-100% without Barometric Relief
D = Economizer, Dry Bulb 0-100% with Barometric Relief
E = Economizer, Reference Enthalpy 0-100% without Barometric Relief
F = Economizer, Reference Enthalpy 0-100% with Barometric Relief
G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief
H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief
K = Low Leak Economizer with Barometric Relief
M = Low Leak Economizer with Reference Enthalpy with Barometric Relief
P = Low Leak Economizer with Comparative Enthalpy with Barometric Relief
Digits 4,5,6 Nominal Gross Cooling Capacity (MBH)
072 = 6 Ton
074 = 7 Ton
090 = 7.5 Ton
092 = 7.5 Ton
102 = 8.5 Ton
120 = 10 Ton
Digits 15 Supply Fan/Drive Type/Motor
0 = Standard Drive
1 = Oversized Motor
6 = Single Zone VAV
7 = Multi-Speed Indoor Fan
E = Multi-Zone Variable Air Volume
Digit 7 Major Design Sequence
H = Major Design Sequence
Digit 16 Hinged Service Access/Filters
0 = Standard Panels/Standard Filters
A = Hinged Access Panels/Standard Filters
B = Standard Panels/2" MERV 8 Filters
C = Hinged Access Panels/2" MERV 8 Filters
D = Standard Panels/2" MERV 13 Filters
E = Hinged Access Panels/2" MERV 13 Filters
Digit 8 Voltage Selection
3 = 208-230/60/3
4 = 460/60/3
W = 575/60/3
Digit 9 Unit Controls
E = Electromechanical
R = ReliaTel™ Microprocessor
Digit 10 Heating Capacity
Note: Applicable to Digit 1, T or W models only
0 = No Electric Heat
C = 9 KW
G = 18 kW
K = 27 kW
N = 36 KW
P = 54 KW
Note: Applicable to Digit 1, D or Y models only
L = Low Heat
M = Medium Heat
H = High Heat
X = Low Heat, Stainless Steel Heat Exchanger
Y = Medium Heat, Stainless Steel Heat Exchanger
Z = High Heat, Stainless Steel Heat Exchanger

Digits 17-31

Digit 17 Condenser Coil Protection
0 = Standard Coil
1 = Standard Coil with Hail Guard
2 = Black Epoxy Condenser Coil Guard
3 = Black Epoxy Condenser Coil with Hail Guard
4 = CompleteCoat Condenser Coil
5 = CompleteCoat Condenser Coil with Hail Guard
Digit 25 System Monitoring Controls
0 = Standard Monitoring System
1 = Clogged Filter Switch
2 = Fan Failure Switch
3 = Discharge Air Sensing Tube
4 = Clogged Filter Switch and Fan Failure Switch
5 = Clogged Filter Switch and Discharge Air Sensing Tube
6 = Fan Failure Switch and Discharge Air Sensing Tube
7 = Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube
A = Condensate Drain Pan Overflow Switch
B = Clogged Filter Switch and Condensate Drain Pan Overflow Switch
C = Fan Failure Switch and Condensate Drain Pan Overflow Switch
D = Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch
E = Clogged Filter Switch, Fan Failure Switch and Condensate Drain Pan Overflow Switch
F = Clogged Filter Switch, Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch
G = Fan Failure Switch, Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch
F = Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Tube and Condensate Drain Pan Overflow Switch
Digit 18 Through the Base Option
0 = No Through-the-Base Provisions
A = Through-the-Base Electric
B = Through-the-Base Gas Piping
C = Through-the-Base Electric and Gas Piping
Digit 26 System Monitoring Controls
0 = No Monitoring Controls
A = Demand Control Ventilation (CO 2)
B = Low Leak Economizer with FDD (Fault Detection & Diagnostics)
C = FDD (Fault Detection & Diagnostics) with DCV (Demand Control Ventilation)
Digit 19 Disconnect/Circuit Breaker
0 = No Disconnect/No Circuit Breaker
1 = Unit Mounted Non-Fused Disconnect
2 = Unit Mounted Circuit Breaker
Digits 27 Unit Hardware Enhancements
0 = No Enhancements
1 = Stainless Steel Drain Pan
Digit 20 Convenience Outlet
0 = Convenience Outlet
A = Unpowered Convenience Outlet
B = Powered Convenience Outlet
Digit 31 Advanced Unit Controls
0 = Standard Unit Controls
1 = Human Interface
Digit 21 Communications Options
0 = No Communications Interface
1 = Trane® Communications Interface
2 = LonTalk® Communications Interface
6 = BACnet® Communications Interface
7 = Air-Fi ™™ Wireless Communications Interface
Digit 22 Refrigeration System Option
0 = Standard Refrigeration System
Digit 23 Refrigeration Controls
0 = Without Refrigeration Controls
1 = Frostat ™™
Digit 24 Smoke Detector
0 = No Smoke Detector
A = Return Air Smoke Detector
B = Supply Air Smoke Detector
C = Supply and Return Air Smoke Detectors
D = Plenum Smoke Detector
Models: YSC120H3RHA0000 DX Packaged Cooling Gas Heat Air Conditioner, YSC120H3RHA0000, DX Packaged Cooling Gas Heat Air Conditioner, Cooling Gas Heat Air Conditioner, Heat Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 29 Pages, 1.96MB

YSC120H3RHA0000 ?srsltid=AfmBOooFP4n8u6xAigDa7uGHPfeBhTS9KVaHgUXvwjU4Dk9kjdHiXf6V iTextSharp 4.1.2 (based on iText 2.1.2u)

Related Documents

Preview Trane 4YCC4036A1090AB Packaged Gas Electric HVAC Unit Parts List and Component Guide
This document provides a comprehensive parts list and technical overview for the Trane 4YCC4036A1090AB packaged gas electric HVAC unit. It details components for the outdoor coil, refrigeration system, fan, blower, controls, heat exchanger, and cabinet, along with optional equipment. Each section includes a textual description of the illustrated components and a detailed table of part numbers, reference numbers, quantities, and descriptions.
Preview Trane Precedent™ High Efficiency Packaged Rooftop Heat Pumps: Product Catalog
Discover the Trane Precedent™ series of high-efficiency packaged rooftop heat pumps, designed for exceptional reliability and advanced comfort control. This catalog details features, specifications, and applications for units ranging from 12.5 to 25 tons, highlighting Trane's commitment to quality and performance in commercial HVAC solutions.
Preview Trane 4TCA4060C Single Packaged Cooling/Electric Heat Specifications and Outline Drawings
Detailed specifications, product information, and outline drawings for the Trane 4TCA4060C Single Packaged Cooling/Electric Heat unit, including technical data, dimensions, and performance characteristics.
Preview Trane Single Packaged Heat Pump, Priority, Two Stage, Convertible, 2-5 Ton, R-454B Product Data and Specifications
Comprehensive product data, specifications, optional equipment, and safety information for Trane's 2-5 Ton Single Packaged Heat Pump systems (R-454B). Details include model numbers (5WCZ5024-5WCZ5060), performance metrics, mechanical features, installation clearances, and available accessories for commercial and residential applications.
Preview Trane TSC060G4R0A001S Packaged Cooling and Heat Pump Parts List and Model Description
Explore the Trane TSC060G4R0A001S packaged cooling and heat pump system with this detailed parts list and model number breakdown. Find component diagrams, part numbers, and configuration specifics for Trane HVAC units.
Preview Trane Packaged Unit Systems: XR13.4c, XL15c - Brochure
Explore Trane's comprehensive range of Packaged Unit Systems, including the XR13.4c and XL15c models. Discover all-in-one heating and cooling solutions designed for flexibility, efficiency, and reliability, with advanced features and robust warranties.
Preview Trane Single Packaged Heat Pump Installation, Operation, and Maintenance Manual (2-5 Ton, R-454B)
Comprehensive guide for installing, operating, and maintaining Trane's 2-5 Ton Single Packaged Heat Pump units (R-454B). Covers safety, specifications, installation, startup, maintenance, troubleshooting, and performance data.
Preview Trane 4WCZ6024A1000A 2-Ton Convertible Heat Pump Packaged Unit Specifications
Detailed product specifications, dimensional data, and performance charts for the Trane 4WCZ6024A1000A 2-Ton Convertible Heat Pump Packaged Unit, including cooling and heating performance, electrical requirements, and optional accessories.