Rheem 26L 876A26, 874A26
Outdoor Continuous Flow Gas Water Heater
Features & Benefits
- 26 L/min continuous hot water delivery @ 25°C rise
- Remote Temperature Controller options available
- 50°C models (876A26) are available and may not require a tempering valve³
- Digital display for easy fault diagnosis
- Available in Natural gas and Propane models
- Compatible accessories include: Pipe cover (299430), Recess Box (299427), Security Cage (299867), Wall Mount Security Kit (299868)
- Comes with a 12-year heat exchanger warranty¹
- Features a 6 Star Energy Rating ?
Dimensions and Connections
The Rheem 26L series is designed for outdoor installation. The unit has a robust construction with specific connection points and dimensions for installation.
Overall Unit Dimensions:
- Height: 585 mm (554 mm to the top of the casing)
- Width: 355 mm
- Depth: 260 mm
Key Connection Points and Dimensions:
The primary connections are located at the bottom of the unit:
- Hot Water Outlet
- Cold Water Inlet
- Gas Connection
- Power Lead Connection
- Gas Connection port thread size: R 3/4. The port is located approximately 53 mm from the bottom and 25 mm from the side.
- Cold Water Inlet port thread size: R 3/4. The port is located approximately 45 mm from the bottom and 105 mm from the side.
- Power Lead Connection is positioned approximately 87 mm from the bottom.
- Control panel area width: 260 mm, with an internal control panel width of 90 mm.
- Control panel depth: 52 mm, with a control panel height of 81 mm.
- Height to internal components: 519 mm.
- Base width: 330 mm, with a 10 mm gap at the bottom.
Specifications Table
Specification | Model 876A26 | Model 874A26 |
---|---|---|
Min. Operating Flow rate (L/min) | 1.5 | 1.5 |
Nom. Gas Consumption (MJ/hr) | 199 | 199 |
Max Water Supply Pressure (kPa) | 1000 | 1000 |
Min Water Supply Pressure (kPa) | 120 | 120 |
Water Connections | R 3/4 | R 3/4 |
Gas Connection | R 3/4 | R 3/4 |
Approx. Weight (Empty) kg | 16 | 16 |