User Guidance for Module BTM1 - Honeywell

User Guidance for Module BTM1

FCC ID: HD5-BTM1; IC: 1693B-BTM1

1. Introduction

Product Marketing Name

BT Module

Module Model Name

BTM1

This module BTM1 is a Bluetooth (BT) module compliant with the BT specification BR/BLE.

2. Electrical

Chipset

SKY66407-11, BR8051A01, H2U34C1H1B0100

Supply

The module sources all required power from a 3.3V +/- 0.1V input supply.

3. Environmental

Operating Temperature

The module operates across the temperature range of -30°C to 50°C.

4. Conditions on using module BTM1

  • Customer must ensure that its product (the "Customer Product") is electrically identical to module BTM1. Customer acknowledges that any modifications to module BTM1 may invalidate regulatory approvals in relation to the Customer Product, or may necessitate notifications to the relevant regulatory authorities.
  • OEM must inform the relevant authorities of any changes which may require Class I or Class II permissive changes for the FCC. Any substituted antenna and RF cable assemblies must be approved to maintain compliance with FCC rules.

5. Regulation Information

5.1 USA - Federal Communications Commission (FCC)

FCC Compliance Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Information to User

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the distance between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Radiation Exposure Statement

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

System integrators must include the FCC ID on the end product.

5.2 Canada - Industry Canada (IC)

Industry Canada Compliance Statement

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

RF Exposure Statement

This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

System integrators must include a label with "Contains IC: 1693B-BTM1" on the end product.

5.3 Europe - EU Restrictions

This equipment needs to be marked with the CE symbol and can be used throughout the European community.

Exposure to Radio Frequency Radiation

To comply with RF exposure compliance requirements, for mobile configurations, a separation distance of at least 20cm must be maintained between the antenna of this device and all persons.

Note for System Integrators

  • The module is tested to comply with Directive 2014/53/EU. System integrators are responsible for compliance of the final device with the RED Directive.
  • Packaging: CE Marking must also be on the outer packaging of the product. The outer packaging must also provide an indication as to where the device is intended to be used and OR conversely, where there may be restrictions for use.

Support Wireless Frequency

Frequency Band

BT 5.0 (2402-2480MHz)

Power

Max e.i.r.p: 8.56dBm

Models: BTM1, HD5-BTM1, HD5BTM1, BTM1 BT Module, BT Module, Module

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=5733649 WPS 文字

Related Documents

Preview Honeywell A700x Series NFC Device EMC Test Report
EMC test report for Honeywell's A700x Series (A710x, A720x, A730x) handheld communication devices, covering radiated emissions, occupied bandwidth, frequency stability, and RF exposure, tested by Laird Connectivity.
Preview Honeywell BW™ Icon+ Multi-Gas Monitor: Features, Specifications, and Benefits
Explore the Honeywell BW™ Icon+ multi-gas monitor, a reliable, user-friendly device offering intelligent sensor technology, smartphone connectivity via the Safety Suite app, and detailed technical specifications for enhanced workplace safety.
Preview Honeywell Lyric C2 Wi-Fi Security Camera Quick Installation Guide
A quick installation guide for the Honeywell Lyric C2 Wi-Fi Security Camera, covering app download, setup, Wi-Fi connection, placement, and operation. Includes troubleshooting and regulatory information.
Preview Honeywell CW45 Mobile Computer Quick Start Guide
Get started quickly with the Honeywell CW45 mobile computer. This guide covers unboxing, device features, battery installation, charging, power management, and basic operations, including setup and troubleshooting.
Preview Honeywell BW™ Icon+ Rivelatore Multigas: Caratteristiche e Specifiche Tecniche
Scopri il rivelatore multigas portatile Honeywell BW™ Icon+. Questa scheda tecnica dettagliata copre le sue caratteristiche innovative, i benefici per la sicurezza e le specifiche tecniche complete per il rilevamento di gas.
Preview Honeywell Embedded Products for Hospital Applications
Honeywell offers embedded sensors, switches, and barcode decoding software designed to enhance patient care and operational efficiency in hospital environments. This guide details product applications across various hospital departments, including Point of Care, Pharmacy, Operating Room, Laboratory, and Neonatal care.
Preview Honeywell SS41F6 Hall-Effect Sensor IC Installation Instructions
Detailed installation instructions for the Honeywell SS41F6 High Voltage and ESD Protection Bipolar Hall-Effect Digital Position Sensor IC, including performance specifications, magnetic characteristics, and safety warnings.
Preview Honeywell 2012 Worldwide Exchange/Rental Program Catalog for Corporate Operators and General Aviation
This catalog details Honeywell's 2012 Worldwide Exchange/Rental Program for Corporate Operators and General Aviation. It outlines procedures for ordering, returning units, pricing, and support for various avionics and mechanical products, including a new process for battery and fan replacements.