EMTEK TEST REPORT
Product Details
Product Name: 14 4-in-1 par lights with remote control
Model Number: Please refer to model list on page 5
FCC ID: 2A6EW-ZQ01424
Preparation and Issuance
Prepared for: Shenzhen Zhuoqiong Technology Co., Ltd.
Address: B503, Block B, Donghaiwang Industrial Zone, No.369 Bulong Road, Ma'antang Community, Bantian Street, Longgang District, Shenzhen Guangdong, China
Prepared by: EMTEK (DONGGUAN) CO., LTD.
Address: -1&2/F., Building 2, Zone A, Zhongda Marine Biotechnology Research and Development Base, No.9, Xincheng Avenue, Songshanhu High-technology Industrial Development Zone, Dongguan, Guangdong, China
Contact: TEL: +86-0769-22807078, FAX: +86-0769-22807079
Report Number: EDG2410110123E00102R
Date(s) of Tests: Oct 11, 2024 to Nov 08, 2024
Date of Issue: Nov 08, 2024
Table of Contents
1. TEST RESULT CERTIFICATION
2. EUT SPECIFICATION
3. TEST REQUIREMENT
4. MEASUREMENT RESULT
1. TEST RESULT CERTIFICATION
Applicant: Shenzhen Zhuoqiong Technology Co., Ltd.
Address: B503, Block B, Donghaiwang Industrial Zone, No.369 Bulong Road, Ma'antang Community, Bantian Street, Longgang District, Shenzhen Guangdong, China
Manufacturer: Shenzhen Zhuoqiong Technology Co., Ltd.
Address: B503, Block B, Donghaiwang Industrial Zone, No.369 Bulong Road, Ma'antang Community, Bantian Street, Longgang District, Shenzhen Guangdong, China
Factory: Shenzhen Zhuoqiong Technology Co., Ltd.
Address: B503, Block B, Donghaiwang Industrial Zone, No.369 Bulong Road, Ma'antang Community, Bantian Street, Longgang District, Shenzhen Guangdong, China
EUT: 14 4-in-1 par lights with remote control
Model Name: Please refer to model list on page 5
Trademark: N/A
Measurement Procedure Used:
APPLICABLE STANDARDS | TEST RESULT |
---|---|
§ 15.247(i), § 2.1093 | PASS |
The above equipment was tested by EMTEK(DONGGUAN) CO., LTD. The test data, data evaluation, test procedures, and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described in this report is in compliance with the requirements of FCC Rules FCC § 15.247(i), § 2.1093.
The test results of this report relate only to the tested sample identified in this report.
Date of Test: Oct 11, 2024 to Nov 08, 2024
Prepared by: Jessica Zhang /Editor
Reviewer: Warren Deng /Supervisor
Approved & Authorized Signer: Sam Lv / Manager
Modified History
Version | Report No. | Revision Date | Summary |
---|---|---|---|
EDG2410110123E00102R | / | Original Report |
2. EUT Specification
Characteristics | Description |
---|---|
Product: | 14 4-in-1 par lights with remote control |
Model Number: | Please refer to model list on page 5. All products are identical except the model number and surface sticker pattern. Here we selected ZQ01424 for all the test. |
Sample: | 1# |
Modulation: | FSK |
Operating Frequency Range(s): | 433.92MHz |
Number of Channels: | 1 channel; |
Transmit Power Max: | 42.48 dBuV@3m |
Antenna Gain: | -1.22 dBi |
Power supply: | DC 3V form battery |
Evaluation applied: | MPE Evaluation, SAR Evaluation |
Model list
ZQ01424, ZQ07030, ZQ10016, ZQ10140, ZQ10137, ZQ10139, ZQ10141, ZQ10134, ZQ03021, ZQ05199, ZQ05198, ZQ05200, ZQ05168, ZQ06017, ZQ01422, ZQ01423, ZQ01425, ZQ01427, ZQ01445, ZQ01639, ZQ01640, ZQ02354, ZQ02061, ZQ02100, ZQ02101, ZQ02024, ZQ02025, ZQ02038, ZQ10133, ZQ10144, ZQ10145, ZQ10146, ZQ10147, ZQ10148, ZQ10149, ZQ10150, ZQ10151, ZQ07032, ZQ07033, ZQ07034, ZQ07035, ZQ07036, ZQ06190, ZQ06191, ZQ06192, ZQ06193, ZQ06194, ZQ06195, ZQ05295, ZQ05296, ZQ05297, ZQ05298, ZQ05299, ZQ03307, ZQ03308, ZQ03309, ZQ03310, ZQ03311, ZQ01138, ZQ01139, ZQ01140, ZQ01141, ZQ01143, ZQ01144, ZQ01145, ZQ01146, ZQ05204, ZQ05189, ZQ05190, ZQ05191, ZQ05192, ZQ05193, ZQ05194, ZQ05195, ZQ02104, ZQ02105, ZQ02106, ZQ02107, ZQ02108, ZQ02570, ZQ02571, ZQ02572, ZQ02573, ZQ02574
3. Test Requirement
SAR Evaluation
According to 447498 D01 V06, systems operating under the provisions of this section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines.
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] * [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where:
- f(GHz) is the RF channel transmit frequency in GHz
- Power and distance are rounded to the nearest mW and mm before calculation.
- The result is rounded to one decimal place for comparison.
- 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below.
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.
Routine SAR evaluation refers to that specifically required by § 2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to quality for TCB approval.
One antenna is available for the EUT. The minimum separation distance is 5mm.
4. Measurement Result
433MHz
Antenna gain: -1.22 dBi
Channel Freq. (MHz) | Max. Strength (dBuV/m) | Field output power (dBm) | peak output power (dBm) | Tune up Power (dBm) | Max. tune up power (dBm) | Calculation Result | Calculation threshold(1-g SAR) |
---|---|---|---|---|---|---|---|
433.92 | 42.48 | -51.56 | -51±1 | -50 | 0.000001 | 3 |
*** End of Report ***