Engine will not start. |
No fuel. |
Add fuel. |
Faulty spark plug. |
Clean and adjust spark plug or replace. |
Low oil level. |
Fill crankcase to the proper level. |
Spark plug wire loose. |
Place generator on a flat, level surface. |
Fuel valve is closed. |
Attach wire to spark plug. |
Ignition switch OFF. |
Open fuel valve. |
Old fuel or water in fuel. |
Press ignition switch ON. |
Flooded with fuel. |
Drain fuel and replace with fresh fuel. |
CO Shield® module has been removed or tampered with. |
Let unit stand for 10 mins. |
Choke lever in the wrong position. |
Re-install module or contact technical support. |
Engine starts but runs roughly. |
Dirty air filter. |
Move choke lever until it stops under "RUN" position or push in completely. |
Dirty fuel valve. |
Clean or replace air filter. |
Clogged spark arrestor. |
Clean the fuel valve. |
Generator battery is dead. |
Clean spark arrestor. |
Out of fuel. |
Recharge generator battery. |
Low oil level. |
Fill fuel tank. |
Engine will not start electrically. |
Low oil level. |
Fill crankcase to the proper level. Place generator on a flat, level surface. |
Engine shuts down during operation. |
If equipped, CO Shield® shutoff due to accumulating carbon monoxide if the red LED light blinks on the panel. |
Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak. |
If equipped, CO Shield® shutoff due system fault if the yellow LED light blinks on the panel. |
Start to confirm yellow LED light blinks when/if generator shuts off. If CO Shield continues sense the fault and shuts off, contact technical support. |
Engine starts and shuts off right away. |
If equipped, CO Shield® shutoff due to accumulating carbon monoxide if the red LED light blinks on the panel. |
Move generator to an open, outdoor area. Point exhaust away from people and buildings. Move to fresh air and get medical help if sick, dizzy, or weak. |
If equipped, CO Shield® shutoff due system fault if the yellow LED light blinks on the panel. |
Start to confirm yellow LED light blinks when/if generator shuts off. If CO Shield continues sense the fault and shuts off, contact technical support. |
Both CO Shield® LEDs not blinking 10 times upon start up. |
Starting the generator within 1 minute after being manually shutoff, not a CO shutoff event. |
Wait 1 minute before trying to restart the generator. The LEDs should then blink ten (10) times. |
Generator cannot supply enough power or overheating. |
Generator is overloaded. |
Review load and adjust. See "Connecting Electrical Loads." |
Dirty air filter. |
Clean or replace air filter. |
Choke lever in wrong position. |
Move choke lever until it stops under "RUN" position or push in completely. |
Engine is running but no AC output. |
Poor cord connection. |
Check all connections. |
Circuit breaker is open. |
Reset circuit breaker. Check all circuit breakers. |
Faulty brush assembly. |
Replace brush assembly (Service Center). |
Loose wiring. |
Inspect and tighten wiring connections. |
GFCI tripped. |
Reset GFCI receptacle breakers by first pushing the TEST button then the RESET button until green LED illuminates. Contact the help line. |
Engine hunts or falters. |
Other. |
Contact the help line. |
Engine governor defective. |
Contact the help line. |
Dirty fuel valve. |
Clean the fuel valve. |
Carburetor is dirty and running lean. |
Contact the help line. |
Choke lever in wrong position. |
Move choke lever until it stops under "RUN" position or push in completely. |
Repeated circuit breaker tripping. |
Overload. |
Review load and adjust. See "Connecting Electrical Loads." |
Faulty power cords or device. |
Check for damaged, bare or frayed wires. Replace defective device. |
Circuit breaker still too hot. |
Let unit sit for 5 mins. |