Philips MasterClass InstantFit T8 LED Tube Light
Model: 13T8-6U/MAS/24-840/IF21/P/DIM 10/1
The MasterClass InstantFit T8 lamps provide hassle-free installation with simple lamp-for-lamp replacements. They deliver at least 40% energy savings, flicker-free performance, and the expected long life. Proven to work with over 200 ballasts and drivers, these lamps deliver even light output with proven energy savings and a long average lifetime. End users will appreciate the comfortable and high-quality light with no visible flicker and optimized optics. Energy managers will benefit from the quantifiable savings. For enhanced energy savings, the MasterClass InstantFit lamps can be paired with Advance TLED drivers to create a Type C system. With an available 70,000-hour life, a 7-year limited warranty, and a shatter-prevention polycarbonate lens, Philips MasterClass InstantFit TLED lamps offer significant benefits.
Product Specifications
General and Light Technical Data
General Information | Value | Light Technical | Value |
---|---|---|---|
Cap-Base | G13 [Medium Bi-Pin Fluorescent] | Color Code | 840 [CCT of 4000K] |
Nominal lifetime | 70,000 hour(s) | Beam Angle (Nom) | 180 degree(s) |
Switching Cycle | 50,000 | Luminous Flux | 2,100 lm |
Lighting Technology | LED | Color Designation | Cool White (CW) |
Correlated Color Temperature (Nom) | 4000 K | ||
Luminous Efficacy (rated) (Nom) | 161.00 lm/W | ||
Color Consistency | <6 | ||
LLMF At End Of Nominal Lifetime (Nom) | 70 % | ||
Color rendering index (CRI) | 80 |
Operating, Electrical, and Mechanical Data
Category | Parameter | Value | Category | Parameter | Value |
---|---|---|---|---|---|
Operating and Electrical | Line Frequency | 20K to 120K Hz | Approval Marks | RoHS compliance UL certificate DLC compliance | |
Input Frequency | 20K to 120K Hz | Energy Consumption kWh/1000 h | - kWh | ||
Power Consumption | 13 W | Energy Certifications | DLC Standard | ||
Wattage Equivalent | 32 W | EU RoHS compliant | Yes | ||
Starting Time (Nom) | 0.5 s | Ambient temperature range | -20 °C to 45 °C | ||
Warm-up time to 60% light | 0.5 s | Application Conditions | can it be used in closed luminaires | Yes | |
Power Factor (Fraction) | 0.9 | ||||
Voltage (Nom) | 120-277, 347 V | ||||
UL Type | UL Type A | ||||
Temperature | T-Case Maximum (Nom) | 50 °C | |||
Controls and Dimming | Dimmable | Yes | |||
Mechanical and Housing | Bulb Finish | Frosted | |||
Bulb Material | Plastic | ||||
Product Length | 600 mm | ||||
Bulb Shape | T8 | ||||
Approval and Application | Energy Saving Product | Yes |
Order and Packaging Data
Parameter | Value |
---|---|
Order product name | 13T8-6U/MAS/24-840/IF21/P/DIM 10/1 |
Full product name | 13T8-6U/MAS/24-840/IF21/P/DIM 10/1 |
Order code | 929001987604 |
Material Nr. (12NC) | 929001987604 |
Numerator - Quantity Per Pack | 1 |
Net Weight (Piece) | 0.270 kg |
EAN/UPC - Product/Case | 046677541873 |
Numerator - Packs per outer box | 10 |
EAN/UPC - Case | 50046677541878 |
Dimensional Drawing
The dimensional drawing illustrates the physical dimensions of the T8 lamp. The following measurements are provided:
Product | D1 | D2 | A1 | A2 | A3 |
---|---|---|---|---|---|
13T8-6U/MAS/24-840/IF21/P/DIM 10/1 | 25.7 mm | 28 mm | 152 mm | 570 mm | 27.8 mm |
Diagram shows a linear tube with labeled dimensions D1 (diameter), D2 (diameter), A1 (length), A2 (length), A3 (length).
Photometric Data
Light Distribution Diagram: This diagram is a polar plot illustrating the light intensity distribution of the lamp. It shows intensity in candela per 1000 lumens (cd/1000lm) at various angles from 0° to 180° and 90° to 270°. The distribution indicates that the light is primarily directed downwards.
Polar plot showing light intensity distribution in cd/1000lm at different angles.
Spectral Power Distribution Colour: This graph displays the light intensity (%) across different wavelengths (nm), ranging from approximately 300 nm to 800 nm. The distribution shows peaks in the blue and yellow/green regions, characteristic of white LED light sources.
Graph of light intensity (%) versus wavelength (nm), showing spectral composition.
General Uniform Lighting: This section indicates the lamp's suitability for general uniform lighting applications.
Lifetime Performance
Lumen Maintenance Diagram (Tc vs. Lumen %): This graph shows how the lumen output (Lumen %) is maintained over different case temperatures (Tc in °C). It presents two curves: B10L70 and B50L70, indicating the lumen maintenance at the 10% and 50% failure rates respectively, at 70% lumen output.
Graph showing Lumen (%) on the Y-axis and Tc (°C) on the X-axis, with B10L70 and B50L70 curves.
Failure Rate Graphs (Time vs. Failure Rate %): These graphs illustrate the lamp's failure rate over time. The Y-axis represents the failure rate in percentage, and the X-axis represents the time in hours, up to 100,000 hours. The curves show an increasing failure rate as the operating hours accumulate.
Two graphs showing Failure Rate (%) on the Y-axis and Time (hours) on the X-axis, up to 100,000 hours.
Lumen Maintenance Diagram (Burning Hours vs. Lumen %): This graph depicts lumen maintenance over burning hours. The Y-axis shows lumen output in percentage, and the X-axis shows accumulated burning hours up to 100,000 hours. The curve indicates a gradual decrease in lumen output over the lamp's lifespan, reaching approximately 70% at 100,000 hours.
Graph showing Lumen (%) on the Y-axis and Burning hours on the X-axis, up to 100,000 hours.