Concord 95G2V Two Stage Variable Speed Gas Furnace

Product Specifications

Form No. 95G2V-100 (08/2015)

Key Features

Heat Exchanger Design

Burners

Cabinet Construction

Air Delivery System

Controls

Configurations

Venting

Installation Features

Warranty

10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details.

Model Number Guide

The model number indicates key features of the furnace:

Example: 95 G 2 UH 110 C V 16-01

Physical and Electrical Data

Model 1st Stage Input (Btuh) 1st Stage Output (Btuh) 2nd Stage Input (Btuh) 2nd Stage Output (Btuh) Nom. AFUE (%) Cooling Capacity (tons) Gas Inlet (in.) Hz/Phase Volts/ Time Delay or Fuse Min. Breaker (Amps) Nom. F.L.A. Approx. Trans. (V.A.) Approx. Weight (lbs.)
95G2UH045BV12 29,000 28,000 44,000 42,000 95.0 3 1/2 120-60-1 15 7.7 40 130
95G2UH070BV12 43,000 41,000 66,000 62,000 95.0 3 1/2 120-60-1 15 7.7 40 138
95G2UH090CV12 57,000 55,000 88,000 84,000 95.0 3 1/2 120-60-1 15 7.7 40 154
95G2UH090CV20 57,000 55,000 88,000 85,000 95.0 5 1/2 120-60-1 20 12.8 40 166
95G2UH110CV20 72,000 70,000 110,000 105,000 95.0 4 1/2 120-60-1 15 12.8 40 173
95G2UH135DV20 88,000 84,000 135,000 126,000 95.0 5 1/2 120-60-1 20 12.8 40 188
95G2DF045BV12 29,000 28,000 44,000 43,000 95.0 3 1/2 120-60-1 15 7.7 40 131
95G2DF070BV16 43,000 42,000 66,000 64,000 95.0 4 1/2 120-60-1 15 10.1 40 136
95G2DF090CV20 57,000 56,000 88,000 85,000 95.0 5 1/2 120-60-1 20 12.8 40 164
95G2DF110CV20 72,000 70,000 110,000 106,000 95.0 5 1/2 120-60-1 20 12.8 40 176

Note: For vent length and clearances to combustibles, please reference installation instructions.

Filter Requirement Data

Airflow Descriptor Disposable Filters Minimum Area (sq. in.) Cleanable Filters Minimum Area (sq.in.)
12 576 288
16 768 384
20 960 480

1. The Airflow Descriptor is the two digits following the "B", "C", or "D" in the model number; e.g. "20" is the Airflow Descriptor.

2. Areas shown for permanent filters are based on filters rated at 600 feet per minute face velocity.

Blower Performance Data (Upflow / Horizontal)

Model Motor Size (hp) Blower Size Heating CFM @ .10" - .80" w.c. Cooling Stage Cooling CFM @ .10" - .80" w.c. Speed Setting Adjust.
Heating Temp. Rise (°F) Setting "D" Setting "C" Setting "B" Setting "A" Setting "D" Setting "C" Setting "B" Setting "A"
95G2UH045BV12 1/2 10x9 35-65 745 875 990 1005 2nd Stage 905 1075 1210 1370 +
685 765 895 910 815 980 1120 1255 Norm
20-50 610 695 785 810 1st Stage 720 885 1020 1135
620 705 800 820 540 660 785 890 Norm
545 625 715 725 485 600 695 790 -
95G2UH070BV12 1/2 10x9 50-80 965 1130 1255 1400 2nd Stage 860 1060 1215 1365 +
880 990 1140 1295 810 960 1130 1265 Norm
810 890 1030 1170 705 840 1005 1140 -
95G2UH090CV12 1/2 10x9 25-55 940 1070 1195 1345 1st Stage 600 740 840 970 +
830 965 1100 1235 555 665 770 855 Norm
755 840 975 1130 500 600 680 790 -
95G2UH090CV20 1/2 10x9 60-90 1060 1135 1240 1430 2nd Stage 875 1040 1210 1360 +
960 1040 1120 1310 800 945 1100 1245 Norm
830 935 980 1175 720 840 970 1115 -
95G2UH110DV20 1 11x11 30-60 960 1040 1120 1310 1st Stage 625 710 830 950 +
875 945 995 1195 565 670 760 860 Norm
790 840 920 1080 520 610 685 785 -
95G2UH135DV20 1 11x11 40-70 1450 1565 1725 1865 2nd Stage 1385 1595 1820 2020 +
1310 1450 1585 1690 1225 1465 1645 1885 Norm
1155 1305 1450 1545 1065 1320 1504 1675 -
25-55 965 1120 1285 1395 1st Stage 835 980 1120 1335 +
865 950 1120 1235 740 870 1010 1150 Norm
95G2UH110DV20 1 11x11 35-65 1155 1325 1420 1565 1st Stage 935 1065 1245 1405 +
1055 1200 1310 1480 865 970 1145 1280 Norm
935 1075 1170 1315 790 890 1025 1165 -
95G2UH135DV20 1 11x11 45-75 1560 1760 1905 2080 2nd Stage 1310 1560 1745 1955 +
1415 1610 1740 1930 1220 1405 1570 1795 Norm
1285 1485 1560 1745 1075 1270 1430 1635 -
35-65 1155 1325 1420 1565 1st Stage 935 1065 1245 1405 +
1055 1200 1310 1480 865 970 1145 1280 Norm
935 1075 1170 1315 790 890 1025 1165 -

Blower Performance Data (Downflow)

Model Motor Size (hp) Blower Size Heating CFM @ .10" - .80" w.c. Cooling Stage Cooling CFM @ .10" - .80" w.c. Speed Setting Adjust.
Heating Temp. Rise (°F) Setting "D" Setting "C" Setting "B" Setting "A" Setting "D" Setting "C" Setting "B" Setting "A"
95G2DF045BV12 1/2 10x9 35-65 735 830 1015 1210 2nd Stage 895 1050 1210 1360 +
680 750 930 1070 805 965 1105 1250 Norm
625 695 835 1000 735 865 1000 1130 -
20-50 705 780 975 1110 1st Stage 640 755 850 975 +
655 730 890 1055 580 695 780 880 Norm
595 670 790 960 545 645 720 795 -
95G2DF070BV16 3/4 11x10 35-65 1110 1305 1430 1700 2nd Stage 1110 1340 1575 1800 +
995 1175 1315 1520 995 1230 1420 1650 Norm
880 1055 1170 1365 880 1085 1290 1460 -
25-55 860 1020 1140 1340 1st Stage 740 915 1055 1255 +
795 910 1030 1230 660 820 940 1120 Norm
680 825 910 1085 575 735 850 995 -
95G2DF090CV20 1 11x11 40-70 1395 1555 1695 1825 2nd Stage 1335 1600 1750 1980 +
1275 1395 1585 1670 1225 1450 1630 1830 Norm
1145 1265 1405 1525 1120 1270 1450 1660 -
30-60 1130 1230 1365 1475 1st Stage 955 1115 1265 1450 +
1040 1130 1250 1340 855 1005 1150 1285 Norm
910 1025 1130 1210 750 890 1060 1170 -
95G2DF110CV20 1 11x11 45-75 1595 1795 1955 2140 2nd Stage 1335 1585 1790 2010 +
1450 1615 1795 1975 1220 1440 1630 1865 Norm
1290 1460 1610 1795 1100 1275 1475 1680 -
35-65 1165 1305 1465 1625 1st Stage 920 1095 1265 1440 +
1055 1185 1315 1475 830 965 1130 1290 Norm
930 1070 1180 1320 735 860 1035 1155 -

Dimensions (In.)

Model A B C D
95G2UH045BV12 17-1/2 16-3/8 16 7-5/8
95G2UH070BV12 17-1/2 16-3/8 16 7-5/8
95G2UH090CV12 21 19-7/8 19-1/2 9-3/8
95G2UH090CV20 21 19-7/8 19-1/2 9-3/8
95G2UH110CV20 21 19-7/8 19-1/2 9-3/8
95G2UH135DV20 24-1/2 23-3/8 23 11-1/8
95G2DF045BV12 17-1/2 16-3/8 16 15-1/2
95G2DF070BV16 17-1/2 16-3/8 16 15-1/2
95G2DF090CV20 21 19-7/8 19-1/2 19
95G2DF110CV20 21 19-7/8 19-1/2 19

Upflow / Horizontal

Front View:

Height: 33"

A: [Dimension A]

B: [Dimension B]

C: [Dimension C]

D: [Dimension D]

Top View:

24-7/8" x 24-3/8"

Right Side View:

26-7/16" (Left Side)

Bottom View:

28-1/2" x 27-3/4"

Downflow

Front View:

Height: 33"

A: [Dimension A]

B: [Dimension B]

C: [Dimension C]

D: [Dimension D]

Top View:

25-3/8" x 22-5/8"

Right Side View:

20-3/4"

Bottom View:

20-1/8" x 19-1/2"

Accessory List

CATALOG NUMBER DESCRIPTION
EXTERNAL FILTER RACK KITS
1.841018 1 pack (16 x 25)
1.841039 10 pack (16 x 25)
NATURAL TO LP KITS
78W94 2-Stage - 90
RETURN AIR BASE
68W62 17.5" B Width
68W63 21.0" C Width
68W64 24.5" D Width
DOWNFLOW COMBUSTIBLE FLOORING BASE
11M60 17.5" B Width
11M61 21.0" C Width
NIGHT SERVICE KITS
84W50 Two Stage
HORIZONTAL SUSPENSION KIT
51W10 80% & 90% Kit
FLUSH MOUNT TERMINATION (90% FURNACES ONLY) US ONLY
51W11 2" & 3" Vent Version
CONCENTRIC VENT KIT (90% FURNACES ONLY) US ONLY
71M80 1-1/2" Vent Version
69M29 2" Vent Version
60L46 3" Vent Version
CONCENTRIC VENT KIT (90% FURNACES ONLY) CANADA
44W92 1-1/2" and 2" Vent Version
44W93 3" Vent Version

For vent length and clearances to combustibles, please reference installation instructions.

PDF preview unavailable. Download the PDF instead.

Concord 95G2V Tech Specs Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Macintosh)

Related Documents

Preview 97G2UHV Gas Furnace Service Manual
Comprehensive service manual for the 97G2UHV Gas Furnace, detailing technical specifications, installation, operation, maintenance, and troubleshooting.
Preview Concord NVR Quick Start Guide
A quick start guide for setting up and connecting your Concord Network Video Recorder (NVR) system, including connecting cameras, monitors, and power.
Preview Concord QC3910 Wi-Fi Battery Powered Camera Quick Start Guide
A quick start guide for the Concord QC3910 Wi-Fi Battery Powered Camera, covering setup, installation, and LED status indicators.
Preview Concord DVR Quick Start Guide
A quick start guide for setting up and connecting your Concord DVR system, including what's in the box, connecting components, and initial setup.
Preview Concord QC3912 Wi-Fi Battery Powered Twin Pack Camera Quick Start Guide
A quick start guide for the Concord QC3912 Wi-Fi Battery Powered Twin Pack Camera, detailing setup, installation, and LED status indicators.
Preview Concord QC3918 Wi-Fi Battery Powered Floodlight Camera Quick Start Guide
A quick start guide for the Concord QC3918 Wi-Fi Battery Powered Floodlight Camera, covering setup, installation, and LED status indicators.
Preview Concord DVR Manual: Installation, Setup, and Operation Guide
Comprehensive manual for Concord DVR systems, covering installation, connection, common operations, setup, live view, recording, playback, search, and network configuration. Includes detailed instructions and safety precautions for optimal system performance.
Preview CONCORD AC5009 8K60 HDMI 4 Way Splitter - Instruction Manual & Features
Comprehensive instruction manual for the CONCORD AC5009 8K60 HDMI 4 Way Splitter. Learn about safety, features, product diagram, connection, troubleshooting, specifications, and warranty. Supports 8K@60Hz, 4K@120Hz, HDR, and HDCP 2.3.