CALIBRATION

This scale has been factory calibrated, and does not require calibration prior to use. There are no requirements for calibration in the field; users should adhere to their institution's calibration policies.

Calibration of your scale can be performed using calibrated kilogram (kg) or pound (lb) weight standards. Minimum calibration is 200 lb / 100 kg. Maximum calibration weight is 1000 lb / 454 kg. The required calibration standard will be the Unit of Measure (UOM) for which the scale is configured. KG models can only be calibrated in kilograms. If Everlock® is engaged, the scale can only be calibrated in the locked unit of measure.

Note: Only weights certified and traceable to national standards should be used for calibration.

Warning: Always ensure that the scale is returned to the correct UOM after scale calibration.

  1. Press Help to access the Help menu options.
  2. While in the Help menu, press [arrow] to select "Calibrate". Press [arrow] to advance to the next step.
  3. The display will prompt for entry of the password. The screen displays 'Calibration Please Enter Password' with options to 'Check Manual for Details' and '[clear-cancel]'.
  4. The display will show a warning. If prepared and qualified to perform the calibration procedure, press [next] to advance to the next step. The screen displays a WARNING: 'Should only be done by qualified personnel! Accuracy will be affected if done improperly!' with '[clear-cancel]' and '[next]' options.
  5. Follow the screen prompt and ensure the scale is on a level surface with no weight on the platform. Press [next] to advance to the next step. The screen prompts: 'Calibration Place scale on level surface and remove all weight' with '[clear-cancel]' and '[next]' options.
  6. The display will show “Zeroing Scale” as it calculates the zero value. Do not touch the scale during the zeroing process. The screen shows 'Calibration Zeroing Scale' with '[clear-cancel]' and '[next]' options.
  7. When the zeroing process is complete, the display will prompt for entry of the calibration weight. Minimum calibration is 200 lb / 100 kg. Maximum calibration weight is 1000 lb / 454 kg. Calibration weight can be adjusted in 10 lb or 10 kg increments. Press [enter] when the calibration weight is set. The screen shows 'Calibration Use arrow keys to set certified weight + 200 Lbs' with '[clear-cancel calibrate]-[enter]' options.
  8. The display will prompt for the calibration weights to be placed on the platform. Press [enter] after calibration weights are placed on the platform. The screen displays: 'Calibration Place Weight on Scale WARNING! Weights must be certified. Use of any other type of weights will cause INACCURACIES!' with '[clear-cancel calibrate] [enter]' options.
  9. The display will show “Calibrating” during the calibration process. The screen shows 'Calibration Calibrating'.
  10. If calibration is successful, the display will show "Calibration Complete” with a 4 digit calibration count. The screen shows 'Calibration Calibration Complete 3885 Counts'.
  11. If calibration is unsuccessful, the display will show an error message that the entered calibration weight and the certified weights do not match. The display will then revert back to the set calibration weight screen for entry of calibration weight. The screen displays an 'Attention Entered Weight and Certified Weight Mis-match! No Calibration Performed' message.

P/N UM2101KL_2101KG_REV20200826_web

Models: 2101 Series Digital Platform Scale, 2101 Series, Digital Platform Scale, Platform Scale

PDF preview unavailable. Download the PDF instead.

2101-series calibration-manual Microsoft Word 2013

Related Documents

Preview Health o meter Digital Lithium Scale User Manual
Comprehensive user manual for the Health o meter Digital Lithium Scale, covering setup, operation, battery replacement, care, and important safety precautions.
Preview Health o meter Digital Lithium Scale User Instructions
User instructions and guide for the Health o meter Digital Lithium Scale, covering scale use, battery replacement, and care.
Preview Health o meter HDM166-60 Weight Tracking Scale User Manual
User manual for the Health o meter HDM166-60 weight tracking scale with progress bar feature. Includes setup, operation, troubleshooting, BMI information, and warranty details.
Preview Health o meter Digital Scale: User Guide and Instructions
Comprehensive guide for the Health o meter Digital Scale (Model HDL050DQ-05), covering setup, operation, battery replacement, care, and warranty information. Learn to use your scale for accurate personal weight measurements.
Preview Health o meter HDM165-53 Weight Tracking Scale User Manual
User manual for the Health o meter HDM165-53 weight tracking scale, covering setup, operation, battery replacement, troubleshooting, FCC statement, and a 5-year limited warranty.
Preview Health o meter Dial Scale User Instructions and Care Guide
Comprehensive user instructions, care guidelines, and safety precautions for the Health o meter Dial Scale. Learn how to use, zero, and maintain your scale for accurate readings.
Preview Health o meter Weight Tracking Scale User Manual (HDM560, HDM770, HDM820)
User manual for Health o meter weight tracking scales, models HDM560, HDM770, and HDM820. Provides instructions on setup, weighing, tracking weight changes, battery replacement, troubleshooting, and warranty information.
Preview Health o meter Digital Scale User Manual and Instructions
Comprehensive user manual for the Health o meter Digital Scale, detailing operation, calibration, battery replacement, care, and safety precautions. Includes model information.