COSLUS E40 Oral Irrigator User Manual
Model: E40
Brand: COSLUS
Product Overview
The COSLUS E40 is an advanced oral irrigator designed to enhance dental hygiene. It features multiple cleaning modes and a rechargeable battery for convenient use.
Key Components:
- Nozzle (A): Directs the water stream for cleaning.
- Nozzle Release Button (B): Allows for easy detachment of the nozzle.
- Water Tank (C): Holds water for operation, with a capacity of 300ml.
- Water Tank Release Button (D): Enables simple removal of the water tank for refilling and cleaning.
- Handle (E): The ergonomic body of the device.
- Mode Button (F): Used to cycle through and select different cleaning modes.
- Power Button (G): Controls the device's on and off functions.
- LED Indicator (H): Displays battery status and selected mode.
- Charging Port (I): Connection point for the charging cable.
- Charging Cable (J): Connects the device to a power source for charging.
- Power Adapter (K): Provides the necessary power for charging the device.
What's in the Box
- Oral Irrigator Main Unit
- Charging Cable
- Power Adapter
- Standard Tip x 2
- Orthodontic Tip
- Periodontal Tip
- Tongue Cleaner
- User Manual
Specifications
Item | Specification |
---|---|
Model | E40 |
Power | DC 5V, 1A |
Battery Capacity | 1400mAh |
Water Tank Capacity | 300ml |
Charging Time | Approx. 4 hours |
Working Time | Approx. 7-10 days (use 2 times/day, 1 min/time) |
Waterproof Level | IPX7 |
Pressure | 70-120 PSI |
Frequency | 1400-1800 times/min |
Material | ABS, PP |
Net Weight | Approx. 300g |
Gross Weight | Approx. 500g |
Important Safety Instructions
Please read all instructions before using this appliance. Failure to follow these warnings may result in electric shock, fire, or personal injury.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- Use only as directed in this manual.
- Do not immerse the main unit in water or other liquids.
- Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
- Do not use on infants or unconscious persons.
- Do not operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water.
- Keep the cord away from heated surfaces.
- Do not block any of the openings.
- Do not use extension cords or outlets with inadequate current carrying capacity.
- This appliance is intended for household use only.
- Save these instructions.
- Do not use if you have open wounds on your gums or in your mouth.
- Consult your dentist before use if you have a medical condition or are undergoing dental treatment.
- This product is not a substitute for regular brushing and flossing.
- Do not use if you have dental work such as crowns, bridges, or implants and experience bleeding, pain, or irritation. Consult your dentist.
- Do not use salt water or hot water (temperature higher than 40°C/104°F).
- Do not operate without water in the tank.
- Do not operate the appliance if the nozzle is not properly attached.
- Do not operate the appliance if the water tank is not properly attached.
How to Use
Follow these steps for optimal use of your COSLUS E40 Oral Irrigator:
- Prepare the Device: Ensure the device is charged. Fill the water tank with clean water (lukewarm water is recommended for sensitive teeth). Attach the desired nozzle securely.
- Select Mode: Press the Power button [power symbol] to turn the device on. Press the Mode button [mode symbol] to cycle through the available modes (e.g., Soft, Normal, Strong). The LED indicator [charging icon] will show the selected mode.
- Operation: Place the nozzle in your mouth, aiming at the gumline at a 90-degree angle. Lean over the sink and start the device. Gently guide the nozzle along the teeth and gumline.
- Complete Use: After use, turn off the device by pressing the Power button [power symbol]. Empty any remaining water from the tank.
- Charging: Connect the charging cable to the charging port on the device and to the power adapter. Plug the adapter into a power outlet. The LED indicator [charging icon] will show the charging status. A full charge takes approximately 4 hours.
Cleaning Instruction Tip
The COSLUS E40 comes with various tips for different cleaning needs:
- Standard Tip: For general daily cleaning of teeth and gums.
- Orthodontic Tip: Designed for cleaning around braces, dental work, and implants.
- Periodontal Tip: For deep cleaning of periodontal pockets.
- Tongue Cleaner: For removing bacteria from the tongue surface.
To use, select the appropriate tip and attach it to the device. Direct the water stream along the gumline and between teeth.
Maintenance
Regular cleaning and maintenance ensure the longevity and performance of your oral irrigator.
- Daily Cleaning: After each use, empty the water tank and rinse it. Rinse the nozzle and the main unit.
- Weekly Cleaning: Detach the water tank and clean it with mild soap and water. Rinse thoroughly. Wipe the main unit with a damp cloth.
- Nozzle Care: Rinse nozzles after each use. Store them in a dry place. Replace nozzles every 3-6 months or if they show signs of wear.
- Descaling: If mineral deposits build up, fill the tank with a 1:1 solution of white vinegar and water. Run the device for a few cycles. Rinse thoroughly with clean water.
Problem Solution
Troubleshooting common issues with the COSLUS E40 Oral Irrigator:
Problem | Cause | Solution |
---|---|---|
Device does not work | Battery is depleted. | Charge the device. |
Device is not turned on. | Press the Power button. | |
Water does not spray | Water tank is empty or not properly attached. | Fill the water tank or reattach it securely. |
Nozzle is clogged or not properly attached. | Clean or reattach the nozzle. | |
Water pressure is weak | Low battery. | Charge the device. |
Nozzle is partially clogged. | Clean the nozzle. | |
Water tank is not filled sufficiently. | Fill the water tank. | |
Device leaks | Water tank is not properly attached. | Reattach the water tank securely. |
The device is damaged. | Contact customer support. |
Disposal
When disposing of this product, please follow local environmental regulations. Do not discard with household waste.
- Empty the water tank and clean the device.
- Disconnect from power.
- Dispose of the main unit and accessories at an authorized recycling facility.