ULTRASONIC CLEANER

USER MANUAL

FEATURES

  • Stainless steel housing, tank and lid.
  • Stamp tank without welding gap for better waterproof.
  • Cooling fan
  • Moisture-proofed PCB
  • Industrial grade IC & ultrasonic transducer

Thank you for purchasing the ultrasonic cleaner. Please take the time to read these operating instructions before use and retain them for future reference. Failure to follow these instructions may lead to serious personal injury and damage to property.

ULTRASONIC PRINCIPLE

Ultrasonic cleaning is based on the cavitation effect caused by high frequency ultrasonic wave vibration signal in the fluid. Microscopic bubbles are formed, and they implode violently, causing the cavitation which creates an intense scrubbing action on the surface of the item being cleaned. The bubbles are small enough to penetrate microscopic crevices, cleaning them thoroughly and consistently.

[Diagram: Illustration showing a generator producing ultrasonic waves that create cavitation bubbles in a fluid. These bubbles implode on the surface of an object, creating a scrubbing action.]

Ultrasonic cleaning is extremely effective at removing dirt and grime which would normally require tedious manual cleaning by hand. It has been used to clean a wide variety of instruments and mechanical parts such as carburetors, returning them to almost "like new" condition without damage to delicate parts.

PREPARATION

  1. Carefully unpack the cleaner and remove all traces of packing materials from it. Visually inspect the cleaner for any parts that may have become loose or damaged during transit.
  2. Contents:
    • Main machine
    • Sound proof lid
    • Power lead
    • Outlet filter
    • Mesh basket (Optional)
    • Manual
  3. Place the cleaner on a flat, clean surface where the cooling fans will receive adequate ventilation and ensure all controls are set to off. Also ensure the drain tap is in the closed position.
  4. Ensure the power lead is securely plugged into the cleaner and that no part of the lead is likely to come into contact with moisture.
  5. Carefully fill at least 1/2 of the tank with a solvent solution. For demanding cleaning, a small amount of washing up liquid is recommended to help increase the cleaning performance. The cleaner is now ready for use.

Attention

⚠️ While the machine is working normally, ultrasonic and tank syntony gives a well-proportioned sound, and no shudder on the surface of the water, yet there is spray made by the tiny bubbles. If there are discontinuous surges, please add or release a little washing solution in the tank; stopping the surges is better for the objects cleaning.

⚠️ On the condition of making sure the cleaning object is cleaned, please run the machine discontinuously as far as possible (not more than 30min.). Long-time running will cause temperature increment of the case.

SAFETY PRECAUTIONS

This unit's voltage is:

⚠️ Keep it away from children ! This device is not intended for use by individuals with restricted physical sensory or metal capacities or those with lack of experience or knowledge, including children, unless they are supervised by an individual responsible for their safety or have received training in operating the device.

⚠️ Please read the following very carefully as failure to comply may invalidate your guarantee:

  1. DO NOT run the cleaner continuously for more than one hour at a time, as doing so can damage the internal components.
  2. DO NOT operate the unit without fluid in the tank. Always ensure the fluid is no higher than the max mark. Always ensure there is a minimum depth of 7cm.
  3. DO NOT drop any item into the tank as this may cause damage to the transducer. Always place the items gently into the tank and use the basket whenever possible.
  4. The more items that you place in your cleaning bath, the less efficient it will clean. It is not advised to overlap items. Always allow plenty of clear space between the items.
  5. Do keep the lid on during use. This will prevent splashes and reduce evaporation of the fluid.
  6. Never immerse the machine or power cord in water or other liquid.
  7. DO NOT touch the power plug with wet hands, especially when inserting or removing the plug.
  8. DO NOT touch the unit if the machine has fallen into water during operation. Remove the power plug from the socket first.
  9. DO NOT disassemble the machine, except by professionals.
  10. UNPLUG the power source while filling or emptying the tank.
  11. DO NOT spray water or liquid over the device and the control panel.
  12. DO NOT operate the cleaner without proper grounding.
  13. DO NOT place the device on a soft surface where the vents could be blocked.
  14. Always turn the heater off after using, as leaving it on can cause the fluid to evaporate and damage the internal components.
  15. Upon completion of the cleaning cycle, turn the heater button off and isolate the machine from the electrical supply.
  16. Take care when adding or removing items from the cleaning tank as the fluid is likely to be hot and displaced fluid can damage the internal components. Any displaced fluid must be dried up immediately.
  17. In the event of failure/emergency, disconnect the mains supply by removing the plug from the mains socket.

APPLICATIONS

This list is almost endless. Provided the product is non porous and can normally be immersed in water, almost anything can be thoroughly cleaned. Here are some examples:

  • Jewellery especially gold, silver & platinum
  • Watchstraps
  • Coins and other collectibles
  • PCB Boards etc
  • Engine/Model parts
  • Toothbrushes & Dentures
  • Electrical components
  • Make-up cases
  • Diesel injection pumps
  • Printer heads and toner cartridges
  • Motorcycle radiators
  • Vehicle differentials
  • Milking parlour equipment
  • Golf clubs & grips & golf balls
  • Horse bits & stirrups & horse brasses
  • Tattoo needles
  • Surgical equipment
  • Motorcycle engine crank cases
  • Engine cylinder heads
  • Turbochargers
  • Bicycle derailleurs
  • Knives, bayonets and other militaria
  • Gun and gun components

Ultrasonic cleaning is not recommended for the following gemstones: Opal, Pearl, Emerald, Tanzanite, Malachite, Turquoise, Lapis and Coral.

DIGITAL ULTRASONIC CLEANER STRUCTURE AND ACCESSORIES

OPERATION

  1. Fill stainless steel tank with liquid; Plug the cleaner into grounded outlet; After powering on, the temperature displays the actual environment temperature, LED displays 3 minutes, which is the default time.
  2. Time setting: Press the “TIME-/TIME+” shortly at a time means time increase/reduce 1min at a time. Press and hold means time will increase/reduce by 1min continuously.
  3. The cleaning stops when the timer counts down to 00:00. If the unit needs to be stopped before the timer runs up, press the ON/OFF button.
  4. Set temperature: Press “temperature-/temperature+" shortly at a time means temperature increase/reduce 1°C at a time. Press and hold means temperature will increase/reduce by 1°C. Usually, the best results are within 40°C to 60°C.
  5. After time and heat setting, press the ON/OFF key to start both functions. Press the "Heating" button "OFF" to stop the heating function. The same applies to the Ultrasonic function.
  6. Empty the tank and clean both the outside and inside of the cleaner with a clean and dry cloth for next use.

NOTE: Do not pour water out until it's cooling. Hot water will hurt you and damage the machine itself.

DIFFERENT WAYS OF CLEANING

General Cleaning—use only tap water. Use warm temperature about 50°C.

Enhanced Cleaning—add a few drops of standard washing up liquid, liquid soap, or detergent into water; other non-acidic cleaning agents can also be used.

Extensive Cleaning—removing tarnish, carbon & rust from non-plated metals. It is recommended to use specialist cleaning solution in association with the ultrasonic cleaner.

WARNING: Strong acid or alkaline cleaning solution will cause corrosion, rust, and even puncture of the tank or machine body. To overcome this problem, dilute to a mild PH solution or request for a tank made of specific grade of stainless steel like SUS304.

The cleaning solution will deteriorate in effectiveness over time and use. It is important to regularly change the fluid and carefully wash the inside of the cleaning tank in order to preserve the effectiveness and longevity of the cleaner. Do not use corrosive or abrasive cleaning products on the tank, which must be wiped down and dried before it can be re-connected to the electrical supply.

NOTE: If the machine starts to spark, smoke, smell of burnt electrics, or displays any other fault, the operator must immediately stop the machine, isolate the electrical supply, and contact the supplier. Continued use is dangerous.

ADVANTAGE

Ultrasonic is widely used throughout industries to remove difficult contaminants from parts during or after manufacturing processes which might require a stage of cleaning before the next process. In general, if an item can be cleaned with liquid, it can be cleaned much faster and more thoroughly with an ultrasonic cleaner. Compared to traditional solvent/scrubbing methods of cleaning in a parts washer, our ultrasonic cleaners:

  • Are more effective at removing contamination
  • Are quicker to achieve the results you want
  • Save employee time (and consequently money) by enabling 'switch on and leave' cleaning
  • Are heated to allow cleaning solvents to work more effectively
  • Use mechanical timers for simplicity, precision, and longevity
  • Produce less mess during use
  • Use less chemistry
  • Provide reproducible results

For Better cleaning effect:

  • The item should be immersed well into the water (do not exceed the "MAX" mark).
  • Warm water (never hot or boiling) and a small amount of washing up liquid will help increase the cleaning performance.
  • Make sure there is good space around each part you put in the tank. The more items that you place in the tank, the less efficiently it will clean. It is not advised to overlap items; if items are laid one on top of the other, the system doesn't work the way it's supposed to.
  • Basket use. Do not put items directly into the bottom of the tank; a suitable basket provides a better cleaning effect. A metal basket absorbs less ultrasonic energy, at about 8%.
  • Temperature: The higher the temperature, the better the cleaning effect. However, when the temperature exceeds 70°C~80°C, the cleaning effect will be affected. The best temperature we suggest is 40°C~60°C.

SPECIFICATIONS

ModelTank Size (L*W*H)mmOverall Size (L*W*H)mmVolume LPower WFrequ ency KHzHeating Power WTime setting MinTemperature °C
PS-08A150×140×65190×170×1501.3601001-990-80
PS-10A150×140×100190×170×1952601001-990-80
PS-20A240×140×100270×170×2203.21201001-990-80
PS-30A300×155×150330×180×2806.518028/43001-990-80
PS-40A300×240×150330×270×2801024003001-990-80
PS-60A330×300×150360×330×280153604001-990-80
PS-80A500×300×150550×330×280224805001-990-80
PS-100A500×300×200550×330×330306005001-990-80

H: 1-99 mins can be adjustable

T: 0-80 °C temperature can be adjustable

D: Digital display

[CE Mark] [FCC Mark] [RoHS Compliant]

Models: Ultrasonic Cleaner

File Info : application/pdf, 8 Pages, 181.90KB

PDF preview unavailable. Download the PDF instead.

original GPL Ghostscript 9.26 ����

Related Documents

Preview Ultrasonic Cleaner User Manual: Installation, Operation, and Troubleshooting Guide
This user manual provides comprehensive instructions for the installation, operation, and maintenance of ultrasonic cleaners. It covers safety guidelines, detailed steps for time and temperature settings, troubleshooting common issues, and a broad range of applications across various industries, including electronics, medical, automotive, and jewelry cleaning. The manual also includes technical specifications for different models (TH-008M to TH-100A) and explains the ultrasonic cleaning principle.
Preview Ultrasonic Cleaner JX-956 Instruction Manual
Comprehensive instruction manual for the JX-956 Ultrasonic Cleaner, detailing product description, specifications, cleaning methods, operation instructions, safety precautions, and maintenance.
Preview Ultrasonic Cleaner SJ-A2 Operation Manual and Safety Guide
Comprehensive operation manual and safety precautions for the Ultrasonic Cleaner Model SJ-A2, detailing its functions, specifications, usage, and maintenance.
Preview Adjust Power Ultrasonic Cleaner User Manual - Specifications and Operation
Comprehensive user manual for the Adjust Power Ultrasonic Cleaner (Model hx28k-24). Includes specifications, preparation, operation instructions, safety precautions, and maintenance guidelines for industrial and laboratory use.