Gamry Instruments' dual-18650 (992-00158) and dual-CR2032 (992-00159) battery holders allow measurements on single batteries or two cells in series.

Product Overview

The document provides instructions for using Gamry Instruments' dual-18650 and dual-CR2032 battery holders. These holders facilitate measurements on individual batteries or two cells connected in series.

Dual-CR2032 Battery Holder: Designed for CR2032 coin cells.

Dual-18650 Battery Holder: Designed for 18650 batteries.

⚠️ Warning: Improper operation creates a safety hazard which can lead to fire, explosion, and emission of hazardous chemicals, potentially causing severe damage, personal injury, or death. Gamry Instruments, Inc. is not responsible for battery failures caused by misuse of the equipment or defects in battery construction.

Specifications

Specification Value
Maximum current rating 10 A @ 20°C
Operating temperature range (holder only) -50 to +125°C
Dimensions: Dual-18650: W: 120 mm, L: 134 mm, H: 32 mm
Dual CR2032: W: 120 mm, L: 89 mm, H: 30 mm

Usage Instructions

For single-cell measurements:

? Tip: Place the positive pole of the coin cell upward when inserting into the CR2032 holder. For 18650 batteries, follow the printed + and – notations on the holder. Correct positioning and cable connections ensure positive voltage measurements.

Gamry strongly recommends measuring the potential of cells once they are mounted in the battery holders for a stable voltage measurement and good contact.

For series measurements:

A shorting bar is provided to connect both batteries for series measurements. The figure illustrates connecting cell leads from a potentiostat to the battery holder:

  1. Place the shorting bar into the connectors labeled 'series'.
  2. Connect the working lead (green) of the potentiostat to WE₁ and the counter lead (red) to CE₂.
  3. Connect the working sense lead (blue) to WS₁ and the reference lead (white) to RE₂.

The shorting bar introduces additional impedance. EIS spectra can be corrected by measuring impedance between CE₁ and WE₂ connected by a shorting bar, and then subtracting this from any EIS spectrum in the Echem Analyst™ software.

Connecting to other potentiostats

When connecting Gamry battery holders to potentiostats from other manufacturers, follow the manufacturer's guidelines for connecting current-carrying cables (counter and working) and sense leads (reference and working sense). Be aware that their cable color-coding may differ from Gamry's scheme.

An accessory kit (990-00406) is available to connect smaller 2 mm banana connectors.

Models: Dual-18650 992-00158, Dual-CR2032 992-00159, CR2032 Battery Holder, CR2032, Battery Holder, Holder

PDF preview unavailable. Download the PDF instead.

Instruction-sheet-for-Battery-Holders Microsoft Word for Office 365

Related Documents

Preview Gamry Instruments Battery Holder Instruction Sheet
Instruction sheet for Gamry Instruments 18650 and CR2032 battery holders, detailing single-cell and series measurement connections for potentiostats.
Preview Gamry LPI1010 Load/Power Supply Interface for Battery and Fuel Cell Impedance Testing
Explore the Gamry LPI1010, a versatile Load/Power Supply Interface designed for advanced electrochemical impedance spectroscopy (EIS) testing of batteries and fuel cells. Learn about its capabilities, system configurations, and specifications for measuring complex impedance across a wide frequency range.
Preview Gamry Potentiostats Quick-Start Guide: Potentiostat Installation
A quick-start guide for installing Gamry potentiostats, covering unpacking, hardware setup, and initial software configuration. Learn how to connect cell cables, USB cables, and power supplies for your Gamry potentiostat system.
Preview Measuring Small Electrochemical Signals: Limitations and Techniques
Explore the challenges of measuring femtoampere (fA) and picoampere (pA) electrochemical signals. This Gamry Instruments application note details factors like Johnson noise, input capacitance, and shunt effects, crucial for Electrochemical Impedance Spectroscopy (EIS).
Preview Interface 5000 Potentiostat/Galvanostat/ZRA Operator's Manual
This operator's manual provides comprehensive instructions and safety information for the Gamry Instruments Interface 5000 Potentiostat/Galvanostat/ZRA. It covers installation, operation, calibration, cell connections, panel indicators, and technical specifications.
Preview Reference 620 Potentiostat/Galvanostat/ZRA Operator's Manual
This operator's manual provides comprehensive instructions and safety information for the Gamry Instruments Reference 620 Potentiostat/Galvanostat/ZRA. It covers installation, operation, troubleshooting, and technical specifications for this electrochemical instrument.
Preview Gamry Instruments Cable Calibration Quick-Start Guide for Potentiostats
This quick-start guide from Gamry Instruments explains the process for cable calibration of their potentiostat, galvanostat, and ZRA instruments. It covers setup, software procedures, and troubleshooting for models like Reference and Interface series, ensuring optimal performance of electrochemical instrument cables.
Preview Reference 620 Potentiostat/Galvanostat/ZRA Operator's Manual
This operator's manual provides comprehensive instructions and safety information for the Gamry Instruments Reference 620 Potentiostat/Galvanostat/ZRA. It covers installation, operation, specifications, and troubleshooting for this advanced electrochemical instrument.