System Overview: HE150 / PP1300 / RF-TOUCH / RF-TOPLINE
⚠️ CAUTION! Electrical components should be connected or disconnected only when the power supply cord is unplugged.
⚠️ CAUTION! There is a delay after the supply voltage is applied before the device actually turns on. Wait at least two seconds before beginning the commissioning.
Components that can be connected:
A diagram illustrates the system setup. It shows the HE150 unit (labeled 1) connected via a distribution cable (labeled 4) to a PP1300 unit (labeled 2). Both units are connected to multiple JLDQ massage motors (labeled 3, 5, 6, 7) via distribution cables (labeled 4, 8). This visual demonstrates the interconnection of these components.
- 1. HE150
- 2. PP1300
- 3. JLDQ Massage motor
- 4. Distribution cable
- 5. JLDQ Massage motor
- 6. JLDQ Massage motor
- 7. JLDQ Massage motor
- 8. Distribution cable
HE150 Component Details
The HE150 unit is depicted with numbered ports (1-8) and their corresponding labels.
Connection ports and functions
- 1. Cable connection (HE-300 SMPS POWER SUPPLY)
- 2. Connection for distribution cable (PP1300 and JLDQ)
- 3. Connection for M3
- 4. Connection for M4
- 5. Connection for massage motor
- 6. Multi-function port for accessories
- 7. Floor lighting (LED white) / Reset / Pairing button (Bluetooth® Pairing LED blue)
- 8. Floor lighting (LED white)
Technical specifications
Input voltage | 24-29 V DC |
Current consumption | max. 6.00 A |
Mode of operation | Intermittent duty (2 min. / 18 min.) |
Protection class | III |
Protection degree | IP20 |
Length x width x height | 196 x 116 x 40 mm |
PP1300 Component Details
The PP1300 unit is shown with numbered ports (9-10) and their labels.
Connection ports and functions
- 9. Connection socket
- 10. Charging socket
Technical specifications
Output voltage | max. 29.4 V DC |
Output current | max. 5.00 A |
Protection degree | IP20 |
Length x width x height | 147 x 77 x 42 mm |
RF-TOPLINE Remote
The RF-TOPLINE remote control is depicted with numbered buttons (1-11) and combination button labels (1+2, 3+4).
Button Functions
Button | Function |
---|---|
1 | Drive M1 up |
2 | Drive M1 down |
3 | Drive M2 up |
4 | Drive M2 down |
5 | Reset M1 + M2 up |
6 | Reset M1 + M2 down |
7 | Memory position 1 |
8 | Memory position 2 |
9 | Memory save button |
10 | Floor lighting on/off |
11 | Flashlight on/off |
1 + 2 | Pairing (first System) / Floor lighting on/off |
3 + 4 | Pairing (second System) or Pairing External Power Socket / Switchable power socket on/off |
Description of button operations
Note: By pressing the buttons, the lights lit blue.
Drive (head rest) up: The drive(s) move as long as this button is pressed.
Drive (head rest) down: The drive(s) move as long as this button is pressed.
Drive (foot rest) up: The drive(s) move as long as this button is pressed.
Drive (foot rest) down: The drive(s) move as long as this button is pressed.
Drive (head & foot rest) up: The drive(s) move as long as this button is pressed.
Drive (head & foot rest) down: The drive(s) move as long as this button is pressed.
Memory position 1: The drives move to the saved position. The drives move as long as this button is pressed.
Memory position 2: The drives move to the saved position. The drives move as long as this button is pressed.
Memory save button: The drives move to their desired positions. Press the memory save button once then press the desired position button within three seconds. The memory position is saved and the floor lighting blinks twice and a "Peep" signal sounds.
Floor lighting on/off: Switch the internal and external floor lighting on/off. The floor lighting turns off automatically after 30 minutes.
Flashlight on/off: The flashlight is on as long as this button is pressed.
Teach-in Procedures
Acknowledgement: The floor lighting will blink twice and a "peep" tone will sound to signal the successful completion of the step.
1. Teach-in for the RF remote or app
To start using the RF remote with a Bluetooth® device, the wireless link with the HE150 must first be established. To use a Bluetooth® device (a smart phone or tablet) with your system, you will first need to download and install the "OKIN" app for your device.
a. Automatic teach-in
Procedure: Insert the power plug into a power outlet. The HE150 will be in pairing mode for 120 seconds, divided as follows: During the first 60 seconds, an RF remote can be discovered (the teach-in). During the next 60 seconds, a Bluetooth® device can be discovered.
The floor lighting and the blue LED are used for indicator light only, not for illumination. They are illuminated during this teach-in phase for the RF remote.
- RF-TOUCH: Press pairing button A in the battery compartment.
- RF-TOPLINE: Simultaneously press buttons 1 and 2.
A successful pairing will be acknowledged. The floor lighting will switch off after the RF remote teach-in process is finished. The blue LED for pairing with a Bluetooth® device starts flashing.
The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged.
If, during the RF remote's teach-in process, you press any button on an already paired RF remote, it switches to the Bluetooth® teach-in mode. If the RF remote or a Bluetooth® device is discovered during the pairing phase, this pairing mode is automatically ended. The floor lighting and the blue LED switch off.
To repeat the automatic teach-in process: First, remove the plug from the power supply. Then wait 60 seconds and insert the plug back into the power supply. You can now start the new teach-in process.
When operating a system in parallel, you must execute the teach-in processes for the HE150s sequentially. First, connect the HE150 to the power supply. Then execute the teach-in process for the first RF remote or Bluetooth® device. Then execute the teach-in for the second device.
Note! Only commission one system at a time. Never configure multiple systems simultaneously.
b. Manual teach-in
The system must be connected to the power supply.
Quickly press the Reset/Pairing button twice on the HE150 (button 7) or the HE-300 SMPS (button 9). The floor lighting and the green pairing LED will illuminate. The HE150 is now in pairing mode for 120 seconds, divided as follows: During the first 60 seconds, an RF remote can be discovered (the teach-in). During the next 60 seconds, a Bluetooth® device can be discovered.
The floor lighting and the blue LED are illuminated during this teach-in phase for the RF remote.
- RF-TOUCH: Press pairing button A in the battery compartment.
- RF-TOPLINE: Simultaneously press buttons 1 and 2.
A successful pairing will be acknowledged. The floor lighting will switch off after the RF remote teach-in process is finished. The blue LED for pairing with a Bluetooth® device starts flashing.
The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged.
If, during the RF remote's teach-in process, you press any button on an already paired RF remote, it switches to the Bluetooth® teach-in mode. If the RF remote or a Bluetooth® device is discovered during the pairing phase, this pairing mode is automatically ended. The floor lighting and the blue LED switch off.
When operating a system in parallel, you must execute the teach-in processes for the HE150s sequentially. First, connect the HE150 to the power supply. Then execute the teach-in process for the first RF remote or Bluetooth® device. Then execute the teach-in for the second device.
Note! Only commission one system at a time. Never configure multiple systems simultaneously.
System Operation
2. Execute a reference movement with the HE150 or HE-300 SMPS
The referencing must be executed in the following scenarios:
- The initial commissioning
- A change in hardware
- After the battery-powered electrical reset function has been executed.
The system has a positional feedback feature. A referencing movement must first be executed before this feature can function properly. Press the Reset/Pairing button on the HE150 (button 7) or the HE-300 SMPS (button 9) until the end position has been reached.
A successful pairing will be acknowledged.
3. Saving the memory positions
You can save different memory locations to the "Memory position" buttons (M1, M2 or M3) as follows:
- Move to the desired positions by pressing the movement buttons on the RF remote or app.
- Press the "Memory save" button and hold for one second.
- Press one of the "Memory position" buttons (M1, M2 or M3) within three seconds. A successful pairing will be acknowledged.
- The desired position is now saved to the memory position button (M1, M2 or M3).
- You can overwrite the saved memory position at any time by repeating this process.
4. Resetting the saved positions to the factory default settings
The memory positions saved to buttons M1, M2 or M3 can be reset to the factory default as follows:
- Press the Memory save button on the RF Touch and hold down for three seconds.
- The "Memory position" buttons (M1 M2 and M3) first light up blue and then white.
- After about three seconds, the background lighting flashes white once.
- Within one second, press and hold the "Floor lighting on/off" button. The successful completion will be acknowledged.
- Release the "Floor lighting on/off" button.
5. Moving two systems in parallel using a sync cable
⚠️ CAUTION! Only connect the electrical components when the power supply is switched off.
Two operating systems can be connected to each other using a sync cable at the multi-function port. In this way, they can be run simultaneously.
- Press the Reset/Pairing button on the HE150 to move both systems to their end positions.
- Disconnect the power plug on both systems from the power socket.
- Connect both systems by connecting the proper synchronous cable to the multi-function port.
- Insert the mains plug from both systems into the power socket.
Parallel operations are possible as soon as both systems are connected to the power supply.
- Parallel mode on: Press the "Parallel mode on/off" button and hold for about three seconds. The blue button illumination will now be lit. The successful completion will be acknowledged.
- Parallel mode off: Press the "Parallel mode on/off" button and hold for about three seconds. The blue button illumination will now go off. The successful completion will be acknowledged.
Both programmed RF remotes can be used to move the systems.
6. Moving two systems in parallel using remote radio signals
⚠️ CAUTION! Only connect the electrical components when the power supply is switched off.
Two systems can be moved and operated simultaneously (parallel mode) using one RF remote.
- Press the Reset/Pairing button on the HE150 to move both systems to their end positions.
- Execute the teach-in process first for system 1 and then for system 2. Note that the teach-in processes are always sequential. The teach-in should never be carried out on two systems at the same time.
The systems are permanently paired together in this mode. The "Parallel mode on/off" button has no function.
The teach-in can be executed for a second RF remote in this mode.
Cleaning and Care
The system was designed so that it would be easy to clean.
- Be sure to unplug the power cord on the power supply before you begin cleaning it!
- Clean the system using a dry antistatic cloth.
- Be sure that you do not damage the connecting cables during the cleaning.
Disposal
The system consists of electronic components, cables and metal and plastic parts. You should observe all corresponding national and regional environmental regulations when disposing of the system.
The disposal of the product is regulated in Germany by Elektro-G, internationally by the EU Directive 2012/19/EC (WEEE), or by any applicable national laws and regulations.
The system should not be disposed of with normal household waste! [symbol of trash bin with cross through it]
FCC Warning / IC Warning
FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: Any changes or modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment.
IC: This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
French Translation: Leprésent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio Exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Company Information
DewertOkin GmbH
Weststraße 1
32278 Kirchlengern
Germany
Phone: +49 (0)5223/979-0
Fax: +49 (0)5223/75182
Website: http://www.dewertokin.de
Email: Info@dewertokin.de