Instruction Manual for TREND models including: XDF153, XDF154, XDF155, XDF253, XDF254, XDF255, XDF153 Ceiling Light, XDF153, Ceiling Light, Light
XDH102 MINILED Fixed LED Downlight 10w in Black/Silver/White - The Lighting Outlet
XDF552 Maxiled 55w Fixed LED Downlight in Black, White or Silver (2700 - The Lighting Outlet
File Info : application/pdf, 2 Pages, 1.48MB
DocumentDocumentApprovals The RCM Marking on this product applies to AS/NZS CISPR15:20011 "Limits and methods of radio disturbance characteristics of electrical lighting and similar equiptments." This product is designed in accordance with AS/NZS60598 "Luminaires, general requirements and tests". MIDILED XDF Model No XDF153 XDF154 XDF155 XDF253 XDF254 XDF255 XDF353 XDF354 XDF355 XDF553 XDF554 XDF555 Input Voltage 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 220-240 Power (W) Colour Temperature CRI 15 3000K 90+ 15 4000K 90+ 15 5000K 90+ 25 3000K 90+ 25 4000K 90+ 25 5000K 90+ 35 3000K 90+ 35 4000K 90+ 35 5000K 90+ 55 3000K 90+ 55 4000K 90+ 55 5000K 90+ Ingress Protection IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 INSTALLATION INSTRUCTIONS Applicable for: XDF15 XDF25 XDF35 XDF55 LIGHT BY SOLID STATE Level 3 290-292 Coward Street Mascot NSW 2020 Ph: (02) 9669 8888 / Fax: (02) 9669 8899 / Email: sales@trendlighting.com.au LIGHT BY SOLID STATE Before Installation Be sure to read this installation pamphlet in its entirety before commencing installation. Always ensure mains power is switched OFF before commencing any electrical work. Step 1 Cut Out XDF15: 120mm XDF25: 120mm XDF35: 150mm XDF55: 150mm Please note: Ensure cut-out corresponds with selected fitting. Step 2 Connect driver to 240v mains Step 3 Bend springs upward and install luminaire into ceiling. Once installed the springs should clamp down on the ceiling to support the fixture. To maintain IP65 rating ensure the luminaire is installed on a flat, level ceilings and the silicone gasket has an adequate seal to the mounting surface. Ensure both the driver and luminaire are not covered with any material. Installation Notes DO NOT COVER MANUFACTURER'S RECOMMENDATION: -NO BARRIER REQUIRED -OBSERVE CEILING CLEARANCES Do not cover luminaire or driver with thermally insulating material. You can however, safely abut timber rafters to simplify layout but a 50mm minimum clearance must be kept around the light fitting from ceiling insulation. Ceiling Clearance A B A: 50mm (luminaire - ceiling B: 50mm (luminaire - insulation) Do not cover luminaire or driver with thermally insulating material. BImepamortDanisttrSibaufetitoynInformation This product must be installed by a licenced electrician in accordance with AS/NZS 3000. Disconnect electricity before any installation. No part of the luminaire should be modified, if the luminaire is damaged it should be returned to Trend Lighting. The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. To maintain Ingress Protection on IP65 Rated luminaires, ensure the fitting is installed in accordance with the installation instructions and the mounting surface is able to provide an adequate seal as per Step 3.