Siemens SITRANS Probe LU240 Ultrasonic Level Transmitter
Continuous Level Measurement
Overview
The SITRANS Probe LU240 is an ultrasonic level transmitter designed for continuous level, volume, and volume flow measurements. It is suitable for liquids, slurries, and bulk materials with a measuring range up to 12 meters (40 ft).
Benefits
- Continuous level measurement up to 12 m (40 ft) range.
- Easy installation and simple startup.
- Programming via a 4-button HMI or SIMATIC PDM.
- Communication via HART.
- ETFE or PVDF transducers available for chemical compatibility.
- Process Intelligence signal processing.
- Auto False Echo Suppression for fixed obstruction avoidance.
- Low power and current startup.
- Optional Bluetooth configuration and monitoring via SITRANS mobile IQ.
Application
The SITRANS Probe LU240 is ideal for level monitoring in water and wastewater industries, chemical storage vessels, and small bulk hoppers. It offers a range of 3 m, 6 m, or 12 m (10, 20, or 40 ft). The Probe LU240 provides high reliability with Process Intelligence, Auto False Echo Suppression, and accuracy of 0.15% of range or 6 mm (0.25 inch) for 6 m and 12 m models.
It supports HART communication on specific models and mA output on all models. The SITRANS mobile IQ app (available for Android, Apple, and Windows devices) offers an intuitive interface for configuration and monitoring. The transducer is available in ETFE or PVDF for chemical resistance, and an internal temperature sensor compensates for temperature changes.
Key applications include chemical storage vessels, filter beds, and liquid storage vessels.
Configuration Diagram
A diagram illustrates the SITRANS Probe LU240 mounted in a tank, showing probes extending into the liquid, with labels for 'Pipe', 'Rungs', and 'Seams'.
Selection and Ordering Data
The SITRANS Probe LU240 is a continuous, non-contact ultrasonic level transmitter with a range up to 12 m (40 ft). It monitors level, volume, and volume flow in liquids, slurries, and solids, featuring easy-to-use quick start wizards.
For online configuration, click on the Article No. in the PIA Life Cycle Portal.
Category | Specification | Article No. |
---|---|---|
Communications | HART (4 ... 20 mA) level, volume, volume flow4) | 7ML5110-0... |
4 ... 20 mA level5) | 7ML5110-0... | |
Ingress Protection | IP66, IP68, Type 4X, 6 | |
Measurement Range/Wetted Parts | 200 ... 3000 mm (7.87 ... 118.11 inch), PVDF Copolymer | 7ML5110-0... |
200 ... 3000 mm (7.87 ... 118.11 inch), ETFE | 7ML5110-0... | |
200 ... 6000 mm (7.87 ... 236.22 inch), PVDF Copolymer | 7ML5110-0... | |
200 ... 6000 mm (7.87 ... 236.22 inch), ETFE | 7ML5110-0... | |
200 ... 12000 mm (7.87 ... 472.44 inch), PVDF Copolymer | 7ML5110-0... | |
200 ... 12000 mm (7.87 ... 472.44 inch), ETFE | 7ML5110-0... | |
Process Connection | 2" NPT [(Taper), ASME B1.20.1] | 7ML5110-0... |
R 2" [(BSPT), EN 10226] | 7ML5110-0... | |
G 2" [(BSPP), EN ISO 228-1] | 7ML5110-0... | |
Non-wetted Parts | Plastic (PBT/PC material) | |
Type of Protection | Ordinary Locations/General Purpose (Non-Ex), CCSAUS, CE, UKCA, KC, RCM, EAC | 7ML5110-0... |
Ordinary Locations/General Purpose (Non-Ex), CCSAUS, FM, CE, UKCA, KC, RCM, EAC1) | 7ML5110-0... | |
Ex i (ia) (Ex-Zone 0/Div. 1)/IS, FM NI (Class I, Div. 2)2) | 7ML5110-0... | |
Electrical Connections/Cable Entries | 2 x M20 x 1.5 (one general purpose Polyamide cable gland and one Polyamide blocking plug provided) | 7ML5110-0... |
1 x 1/2" NPT (no gland cable provided) | 7ML5110-0... | |
Local HMI | Without display (blind lid of PBT/PC material) | 7ML5110-0... |
With display (blind lid of PBT/PC material) | 7ML5110-0... | |
With display (clear lid of PC material) | 7ML5110-0... |
For custom electrical connections/cable entries, contact a local sales person. More information is available at: www.automation.siemens.com/aspa_app.
Further Designs
To specify further designs, add "-Z" to the Article No. and provide the Order code(s).
Description | Order Code |
---|---|
Stainless steel tag [13 x 45 mm (0.5 x 1.75 inch)]: Measuring-point number/identification (max. 32 characters) | Y15 |
Declaration of compliance 2.1 (EN 10204) - delivery meets order requirements | C19 |
Certificate EN 10204-2.2 | C14 |
Wireless communication: Bluetooth6) | F50 |
Approvals3): ATEX II 1G Ex ia IIC T4 Ga, Ta = -40 °C to +80 °C; UKEX II 1G Ex ia IIC T4 Ga, Ta = -40 °C to +80 °C; IECEx Ex ia IIC T4 Ga, Ta = -40 °C to +80 °C; EAC Ex 0Ex ia IIC T4 Ga, IP67/IP68; SABS Ex ia IIC T4 Ga, Ta = -40 °C to +80 °C | E31 |
Approvals3): FM non-incendive - Class I, Div. 2, Groups A, B, C, D T5 (Ta = 80 °C), T6 (Ta = 40 °C)1) | E32 |
Approvals3): NEPSI, KCs, IECEx - Ex ia IIC T4 Ga | E33 |
Approvals3): CCSAUS, KCs, FM - Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T4, INMETRO, IECEx - Ex ia IIC T4 Ga1) | E34 |
For customs, contact a local sales person. For more information please visit www.automation.siemens.com/aspa_app.
Technical Specifications
SITRANS Probe LU240
Parameter | Specification |
---|---|
Mode of operation | Ultrasonic level measurement |
Measuring principle | Level measurement in storage vessels and simple process vessels |
Typical application | |
Inputs | |
Measuring range | 0.2 ... 3 m (8 inch ... 10 ft) |
0.2 ... 6 m (8 inch ... 20 ft) | |
0.2 ... 12 m (8 inch ... 40 ft) | |
Frequency | 54 kHz |
Outputs | |
mA/HART | 4 ... 20 mA |
Range | ± 0.0096 mA |
Accuracy | ± 0.15% of range or 6 mm (0.25 inch) [valid from 0.25 m (0.82 ft)] for 6 m and 12 m models; 10 mm (0.39 inch) for 3 m model. |
HART version | 7 |
Startup current | 3.6 mA |
Fail-safe | Programmable as high, low, or hold (loss of echo) per NAMUR NE43 |
Performance | |
Resolution | ≤ 3 mm (0.12 inch) |
Accuracy (3 m version) | 10 mm (0.39 inch) |
Accuracy (6 m, 12 m version) | ± the greater of 0.15% of range or 6 mm (0.25 inch) [valid from 0.25 m (0.82 ft)] |
Non-repeatability | ± 2 mm (0.08 inch) on ranges 4 m (13 ft) or less |
Blanking distance | 0.2 m (0.66 ft) |
Update time | ≤ 4 s |
Temperature compensation | Built-in to compensate over temperature range |
Beam angle | 10° |
Rated operating conditions | |
Ambient conditions | |
Location | Indoor/outdoor |
Ambient temperature | Storage: -40 ... +85 °C (-40 ... +185 °F) Operating: -40 ... +80 °C (-40 ... +176 °F) |
Relative humidity/ingress protection | Suitable for outdoor, Type 4X, Type 6, IP66, IP68 |
Installation category | II |
Pollution degree | 4 |
Medium conditions | |
Temperature at flange or threads | -40 ... +85 °C (-40 ... +185 °F) |
Pressure (vessel) | 0.5 bar g (7.25 psig) |
Display | -20 ... +80 °C (-4 ... +176 °F) |
Design | |
Material (enclosure) | PBT (Polybutylene Terephthalate) |
Degree of protection | Type 4X, Type 6, IP66, IP68 |
Weight | 0.93 kg (2.1 lb) |
Cable inlet | 2 x M20 x 1.5 cable gland or 1 x 1/2" NPT thread |
Material (transducer) | ETFE (Ethylene Tetrafluoroethylene) or PVDF (Polyvinylidene Fluoride) Buna-N seal |
Process connection | |
Threaded connection | 2" NPT [(Taper), ASME B1.20.1] R 2" [(BSPT), EN 10226] G 2" [(BSPP), EN ISO 228-1] |
Flange connection | 3 inch (80 mm) universal flange |
Technical Specifications (continued)
Parameter | Specification |
---|---|
Other connection | FMS 200 mounting bracket (see FMS mounting bracket product page for more information) or customer supplied mount. |
Display and Controls | Local: LCD display Remote: Available via HART or Bluetooth |
Interface | 4-button HMI |
Configuration | Non-volatile EEPROM, no battery required |
Memory | |
Power supply | 10.5 ... 30 V DC |
4 ... 20 mA/HART | |
Certificates and Approvals | |
General | FM, CCSAUS, CE, UKCA, RCM, EAC, KC, VLAREM II |
Hazardous | |
Intrinsically Safe | |
Europe | ATEX II 1G Ex ia IIC T4 Ga |
UK | UKEX II 1G Ex ia IIC T4 Ga |
International | IECEx SIR 18.0013X Ex ia IIC T4 Ga |
USA/Canada | FM/CCSAus Class I, Div. 1, Groups A, B, C, D, Class II, Div. 1, Groups E, F, G, Class III T4 |
Brazil | INMETRO Ex ia IIC T4 Ga |
China | NEPSI Ex ia IIC T4 Ga |
South Africa | SABS Ex ia IIC Tx Ga |
Russia | EAC Ex 1G Ex ia IIC T4 Ga |
Korea | KCs Ex ia IIC T4 |
Non-incendive | |
USA | FM, Class I, Div. 2, Groups A, B, C, D Tx |
Metrological | MCERTS, CPA, Kazakhstan pattern approval |
Radio (Bluetooth) | USA, Canada, EU, China |
Options
The SITRANS Probe LU240 offers various options for mounting and connectivity.
Optional Flange Adapter
A diagram shows the SITRANS Probe LU240 with an optional flange adapter, providing dimensions in mm (inch). The overall diameter is 190 mm (7.48 inches) and the adapter height is 24 mm (0.94 inches).
Optional FMS 200 Universal Box Bracket
An illustration shows the SITRANS Probe LU240 mounted with the optional FMS 200 universal box bracket.
Dimensional Drawings
Detailed dimensional drawings are provided for the SITRANS Probe LU240, including:
- Overall dimensions: 113.4 mm (4.46 inches) height, 51 mm (2.0 inches) width, Ø108 mm (4.25 inches) diameter.
- Threaded coupling: 1/2" NPT (optional), 21 mm (0.83 inches) length.
- Transducer housing: PVDF or ETFE, with dimensions 107.4 mm (4.22 inches) and Ø51 mm (2.0 inches).
- Thread types: 2" NPT, 2" BSP, or PF2/G.
- Bluetooth adapter (optional) and associated dimensions.
Circuit Diagrams
Illustrations show the SITRANS Probe LU240 connections, detailing the interface for the display cable, with labels for the female and male ends of the display cable.