Homcom Lift Chair Assembly & Instruction Manual
Model: INcxa016_UK, 713-090V70
Brand: Homcom
Certifications: CE, UKCA
Introduction
We're excited for you to regain your independence with Homcom! To ensure the best experience, please read this guide carefully before using your new lift chair. Be sure to keep this manual close by, preferably in your chair pocket so that you can always refer to it as needed.
This manual covers:
- Safety Rules
- Lift Chair Parts
- Assembly Instructions
- Lift and Recliner Function
- Functional Description Of Massager
- Troubleshooting
Safety Rules
- Never set the lift chair in wet/damp areas or where dust can accumulate as these could cause an electrical fault or a mechanical dysfunction.
- Never use the lift chair inside your home if the room temperature is over 40°C.
- Never place the lift chair near a heat source (oven, chimney, furnace etc.) or in direct sunlight.
Do Not use the lift chair if:
- The lift chair is wet.
- Your hands are wet.
- Only clean the chair with a dry cloth.
Situations where you should not use the lift chair:
Switch the lift chair's system off if it gets wet or seems not to be working properly, if any part of the lift chair is damaged or malfunctioning, or if any part of the lift chair appears to be damaged or wiring is exposed.
Usage:
- Indoors, avoid high temperatures and wet or damp areas.
Precaution:
- Never sit on the remote or place heavy objects on top of it.
- Do not drop the remote on the floor.
- Do not tug on the electric cable.
- Do not use the remote with wet fingers.
- Do not press or touch the buttons with sharp objects.
- Never unplug the remote without first turning the power off.
- The lift chair should rest for 30 minutes after it has been used for 30 minutes.
When the system of the lift chair is not in use:
- Make sure it is switched off.
- Unplug the lift chair's system from the wall outlet when you are not going to use it for long periods of time.
- Keep the lift chair in a clean and dry place.
Disassembling the Massage Armchair
- Do not remove the back of the armchair.
- Do not try to disassemble or repair the armchair yourself.
Correct Way to Handle the Mains Plug:
- Check that you have the right voltage.
- Never use force on the cable or plug.
- Never pull the cable with wet hands.
- When removing the plug, hold the plug itself, do not pull on the cable.
- Do not use the armchair massage system if either the cable or the plug are damaged.
The Parts Forming the Massage Armchair:
A line drawing of the chair identifies the main components:
- Back
- Armrests
- Seat
- Footrest
- Control unit
Assembly Instructions
Packing Details: Total 2 Boxes
Box 1/2
NO. | PARTS | QTY | NO. | PARTS | QTY | NO. | PARTS | QTY |
---|---|---|---|---|---|---|---|---|
A | [Chair Base Unit] | 1 | I | [Power Cord] | 1 | L | [Bolt] | 4 |
B | [Backrest] | 1 | J | [Bracket] | 2 | E | [Motor/Wiring Harness] | 1 |
G | [Power Adapter] | 1 | K | [Washer] | 4 | F | [Control Box Wiring] | 1 |
H | [Power Supply Unit] | 1 |
Box 2/2
NO. | PARTS | QTY |
---|---|---|
C | [Left Armrest] | 1 |
D | [Right Armrest] | 1 |
Step 01: Base Assembly
A diagram shows the attachment of the base unit (A) using hardware: two brackets (J), four washers (K), and four bolts (L).
Step 02: Attaching Chair Sections
A diagram illustrates connecting the left armrest (C) and right armrest (D) to the chair base.
Step 03: Connecting Electrical Components
A diagram shows attaching the backrest (B) and connecting the electrical components, including the motor/wiring harness (E), control box wiring (F), and the remote control (likely part of E or F).
Step 04: Power Supply Connection
A diagram illustrates connecting the power supply unit (G), power adapter (H), and the power cord (I) to the chair's electrical system.
Lift and Recliner Function
A diagram shows the chair in upright and reclined positions with arrows indicating movement.
- Pressing the right button moves the back down and the footrest up.
- Pressing the left button returns the chair to its normal position, and continuing to press it will smoothly lift the chair.
- To stop the chair at any time, simply release the button being pressed.
Warning
- Never press both buttons together as this will damage your chair.
- Never stand up while the chair is still working to avoid accidents.
Functional Description of Massager
Remote Control Layout
A diagram illustrates the remote control with the following functions:
- Massage zone selection (Back / Lumbar / Thigh / Leg)
- Massage modes selection
- Massage intensity adjustment (+/- buttons)
- Massage ON/OFF button
Product Features
- 8 Vibration Motors
- Eight Massaging modes
- Five Adjustable intensity levels
- Four massage zones, each zone can be operated individually
- The default timing is 15-30 minutes
How to Use
- Insert the adapter jack into the socket found on the back of the massage chair.
- Plug the adapter into a wall outlet.
- Turn the unit ON by pressing the ON/OFF button once. The LED will illuminate when power is on.
- Turn on the massage in each zone by pressing the Massage zone buttons. LEDs will illuminate when each zone is activated. To turn off a zone, press the button again.
- To choose a desired massage mode, press the MODE button. To change modes, press the MODE button until the LED for the desired mode illuminates.
- To change the massage intensity, press the +/- button.
- NOTE: Discontinue use immediately if you feel any discomfort or pain.
- NOTE: For your benefit, the massage chair is equipped with an auto shut-off feature that will turn the chair unit off after 15/30 minutes of continuous use.
- DO NOT use for more than 30 minutes of continuous use.
Important Safety Instructions
When using an electrical appliance, basic precautions should always be followed, including the following:
- This product is for use on a 12V circuit. Make sure that the product is compatible.
- Only use this product with the original power supply type nr: IVP1200-0500.
- Always unplug the massager from the power source after use, and before cleaning.
- Do not reach for the massager if it has fallen into water. Unplug immediately.
- An appliance should never be left unattended when plugged in. Unplug from outlet when not in use, before putting on or taking off parts or attachments.
- Do not use outdoors.
- Do not carry this appliance by the supplied cord as a handle.
- Keep the cord away from heated surfaces.
- Close supervision is necessary when this appliance is used by or near children, invalids, or disabled persons.
- This unit is not a toy. Children should not use it or play with it.
- Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
- Do not use near eyes or other highly sensitive areas.
- To disconnect, push the "POWER" key to "OFF" place, make sure all functions stopped, then remove the plug from the outlet.
- Keep cord away from heated surfaces.
- Use this appliance only for its intended use as described in this manual. Do not use attachments not provided with the unit.
Health Cautions for Massage Chairs
- If you have any concerns regarding your health, consult your doctor before using this product.
- Individuals with pacemakers should not use this product.
- If you experience pain in a muscle or joint for a prolonged period of time, discontinue use and consult your doctor. Persistent pain could be a symptom of a more serious condition.
Maintenance Instructions
To Store:
Place the unit in its box or a safe, dry, cool place. Avoid contact with sharp edges or pointed objects which might cut or puncture the fabric. Do not wrap the power cord around the unit. Do not hang the unit by the power cord.
To Clean:
- Ensure the unit is unplugged from the power source and allowed to cool before cleaning.
- Do not place in any liquid to clean. Clean fabric cover by wiping with a damp sponge, using a mild detergent or suds. Pat dry with a clean, dry cloth.
- Do not use abrasive cleaners, brushes, gasoline, kerosene, glass/furniture polish, paint thinner, or water hotter than 120°F (49°C) to clean the unit.
- To clean the unit, make sure the massager is unplugged. Allow the unit to cool and then wipe down with a damp clean cloth. Do not use any strong chemical cleaners.
Troubleshooting
Problem: The lift chair does not function when the button on the control unit is activated.
Possible Cause:
Check that the plug is pushed into the wall outlet properly. Check whether the power supply button is on.
Technical Specifications
115V | 230V | Unit | |
---|---|---|---|
Input voltage | 100-240 | 100-240 | V |
Input AC frequency | 50-60 | 50-60 | Hz |
Output voltage | 29 | 29 | V |
Output current | 1.8 | 1.8 | A |
Output power | 52.2 | 52.2 | W |
Average active efficiency | 88.21 | 88.43 | % |
Efficiency at low load (10 %) | 88.21 | 88.43 | % |
No-load power consumption | 0.041 | 0.112 | W |
Importer Information
Importer: MH STAR UK LTD
Address: Unit 27, Perivale Park, Horsenden lane South, Perivale, UB6 7RH
Website: https://www.aosom.co.uk
Made in China