Neewer S101 Studio Strobe Flash User Manual

Safety Instructions

To ensure the safety of users and others, please read the following safety advice before using this product. Pay attention to the precautions indicated in the manual. Check the product before use and do not use damaged parts.

Package Contents

The package includes:

Features

1. Trigger

2. Studio Strobe Flash

Mounting

1. Installing the Studio Strobe Flash

  1. Mount the adapter onto the lamp tripod and tighten the retaining knob.
  2. Turn the adjustment knob to adjust the direction of the studio strobe flash.

2. Installing the Modeling Lamp

  1. Pull back the retaining buckle at the top. Turn the protective cap counterclockwise to align the buckle with the hole. Remove the protective cap.
  2. Install the modeling lamp by turning it clockwise.
  3. Remove the modeling lamp by turning it counterclockwise.

3. Replacing the Flash Tube

  1. Ensure the power is off and wear insulated gloves before replacing the modeling lamp and flash tube.
  2. Hold the 2 teeth of the flash tube and gently pull the tube outwards.
  3. Remove the steel wire from the tube.
  4. Remove the cover from the teeth of the old tube and reuse it for the new one.
  5. Align the 2 pins of the flash tube and insert them into the 2 connector holes.
  6. Wrap the steel wire around the stainless steel piece until the flash tube is secured.

4. Installing the Umbrella

  1. Align the position of the standard cap closure with the hole, push the standard cap inwards, and turn clockwise until the standard cap clicks into place.
  2. Open the umbrella.
  3. Pass the umbrella handle through the standard reflector and the umbrella holder, and tighten the fastening knob clockwise.
  4. The umbrella is now ready for use.

Note: The soft light umbrella is not included in the accessories and must be purchased separately.

5. Connecting the Trigger

  1. Attach the trigger to the hot shoe mount of the camera.
  2. If there is no hot shoe, it can also be connected with a sync cord.

Operating Instructions

1. Instructions for Using the Studio Lamp

Connect the cable to power the studio lamp and turn on the power switch.

Note: The wireless ID is equivalent to the numerical password. The remote control ID of the lamp must be set to the same value when the wireless remote control activates the flash.

2. Instructions for Using the Trigger

  1. Set the trigger combination to match the studio lamp channel.
  2. Insert batteries into the trigger and turn on the power switch. Press the test button. If the indicator light turns red, the trigger is successfully connected to the studio light.

3. Setting Studio Lamp and Trigger Channel ID

If the studio lamp's ID code is off, the studio lamp and trigger must be set to the same channel to trigger the flash, as shown in the table below.

Channel No. Studio Lamp Channel Transmitter Dial Code Channel
1 CH 1 CH 1
2 CH 2 CH 2
3 CH 3 CH 3
4 CH 4 CH 4
5 CH 5 CH 5
6 CH 6 CH 6
7 CH 7 CH 7
8 CH 8 CH 8
9 CH 9 CH 9
10 CH 10 CH 10
11 CH 11 CH 11
12 CH 12 CH 12
13 CH 13 CH 13
14 CH 14 CH 14
15 CH 15 CH 15
16 CH 16 CH 16

Notes:

  1. The camera is for illustration purposes only and must be purchased separately.
  2. Do not use the flash on passing vehicles.
  3. Do not disassemble or modify the product.
  4. Do not touch the product with wet hands.
  5. If flammable substances are present, turn off the modeling lamp every 10 minutes and let it cool before using it again.
  6. Do not subject the flash or modeling lamp to any form of physical shock, as this may cause internal damage.
  7. Do not activate the modeling lamp when the protective cover is in place.
  8. Turn off the power when the product is not in use or when moving the flash.
  9. Turn off the power immediately if you notice any abnormal operation during use.
  10. It is normal for the lamp housing to heat up slightly during use. Avoid continuous activation of the flash.
  11. Please note that flash tubes and modeling lamps are consumables and are not covered by the warranty.

Product Specifications

Model Power Display Index (with reflector) Recycle Time (US) Recycle Time (EU) Power Supply Trigger Method Color Temperature Flash Mode Flash Duration Staged Power Adjustment Modeling Lamp Modeling Lamp Range Flash Power Control 2.4G Type-C Port Fuse Dimensions Net Weight
S101-250W PRO 250Ws GN54(m ISO 100) ≈0.1~1.5S ≈0.1~1.2S AC100~120V, 50/60Hz (US, JP)
AC200~240V, 50/60Hz (EU, UK, AU)
2.4G, S1/S2, 3.5 mm sync cord, test cable 5600±200K M/OF 1/100~1/1000S 60 levels 1/1~1/64 (10.0~4.0) 150W 10%~100% (adjustable in 10% increments) OF, 4.0~10 (1/64~1/1) Wireless Slave/OF
Grouping: A/B/C/D/E
Channel: CH1-CH32
ID: 1-99/OF
Range: approx. 100m
5V 8A/250VA 126×269×256mm 2.6kg
S101-300W PRO 300Ws GN58(m ISO 100) ≈0.1~1.8S ≈0.1~1.3S
S101-400W PRO 400Ws GN65(m ISO 100) ≈0.1~2.4S ≈0.1~1.7S

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

This equipment complies with FCC's RF radiation exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must be installed and operated to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter. Installers must ensure that 20cm separation distance will be maintained between the device (excluding its handset) and users.

Company Information

Shenzhen Neewer Technology Co., Ltd.
Room 1903, Block A, Lu Shan Building No. 3023
Chunfeng Rd Luo Hu District, Shenzhen
Guangdong 518001, China

UK REP
Lingfeng Electronic (UK) Ltd
International House, 10 Churchill Way, Cardiff,
CF10 2HE, United Kingdom

EC REP
NW Formations GmbH (for authorities only)
Hoferstrasse 9B, 71636 Ludwigsburg, Germany

Models: S101, Pro Studio Strobe Light, Studio Strobe Light, Strobe Light, S101, Light

PDF preview unavailable. Download the PDF instead.

S101-300W PRO S101-400W PRO ?v=1645425271 Adobe Illustrator CS6 (Windows) 3-Heights™ PDF Optimization API 6.9.0.3 (http://www -tools.com)

Related Documents

Preview Neewer S101 Studio Strobe Light User Manual and Specifications
Comprehensive user manual for Neewer S101-300W and S101-400W Studio Strobe Lights. Includes setup, operation, features, specifications, safety, and troubleshooting.
Preview NEEWER QPro-S Wireless Flash Trigger User Manual
User manual detailing the setup, operation, features, and troubleshooting of the NEEWER QPro-S wireless flash trigger for Sony cameras and NEEWER speedlite flashes, including TTL and HSS capabilities.
Preview Neewer QPro-C TTL Wireless Flash Trigger Instruction Manual
Comprehensive instruction manual for the Neewer QPro-C TTL Wireless Flash Trigger, covering product overview, package contents, setup, operation, custom functions, troubleshooting, and specifications for Canon cameras.
Preview NEEWER VISION4 Studio Flash Instruction Manual
Comprehensive user manual for the NEEWER VISION4 battery-powered studio flash, covering controls, operation, settings, maintenance, and specifications. Learn how to use and care for your VISION4 flash.
Preview Neewer QPro-F Flash Trigger User Manual and Guide
Comprehensive guide to the Neewer QPro-F Flash Trigger, covering product overview, package contents, diagrams, setup, usage, trigger settings, compatible models, and troubleshooting.
Preview Neewer Z2-C Strobo Flash Instruction Manual
Comprehensive guide to operating the Neewer Z2-C Strobo Flash, covering features, specifications, safety precautions, and usage for photography.
Preview NEEWER QZ Trigger: Comprehensive Guide to Wireless Flash Control
A detailed guide to the NEEWER QZ Trigger, covering its features, operation, compatibility, and troubleshooting for photographers using NEEWER and compatible flash systems.
Preview Neewer Z2-C Flash User Manual and Guide
Comprehensive user manual for the Neewer Z2-C camera flash, detailing features, specifications, operation modes (TTL, Manual, Stroboscopic), wireless functionality, safety precautions, and troubleshooting tips.