Installation Guide for Altronix models including: ALT-NETWAY1DWPH, NETWAY1DWPH, NETWAY1DWPH PoE Injector, ALT-NETWAY1DWPH NETWAY1DWPH PoE Injector, PoE Injector, Injector
Altronix NETWAY1DWPH | Midspan Injector, Outdoor, Single Por
Altronix - NETWAY1DWPH - Outdoor Midspan Single Port Hi-POE Injector - Hardware Accessories: Enhance Your Projects with High-Quality Components
File Info : application/pdf, 8 Pages, 1.08MB
DocumentDocumentPower over the Ethernet NetWay1DWP Outdoor Single Port Hi-PoE Injector for Standard and Enhanced Power Network Infrastructure Installation Guide I.T.E. 43KC Rev. 112713 More than just power.TM Installing Company: _______________ Service Rep. Name: __________________________________ Address: _____________________________________________ Phone #: __________________ Table of Contents: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 3 Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 4 Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 5 Wall Mount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 7 Pole Mounting Using Optional Pole Mount Kit PMK1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 7 Enclosure Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 8 - 2 - NetWay1DWP Installation Guide Overview: Altronix NetWay1DWP Outdoor Single Port Midspan Injector provides Hi-PoE (60W) power and passes data for PoE compliant cameras/edge devices. Cameras/edge devices may be located up to 100m from the unit. Features: Agency Listings: · UL 60950-1 Information Technology Equipment. UL 60950-22 Information Technology Equipment to be installed Outdoors. · CE European Conformity. Input: · 115VAC, 60Hz, 1.2A or 230VAC, 50/60Hz, 0.75A. Power Output: · Maximum power: Hi-PoE (60W) power product using all 4 pairs for 60W. · IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant. · Integral surge protection. Ethernet: · Connectivity: RJ45, auto-crossover. · Wire type: 4-pair Cat-5 or better structured cable. · Distance: up to 100m. · Speed: 10/100/1000Mbps, half/full duplex, auto negotiation. LEDs: · LED1: PoE active. LED2: AC Power present. Environmental: · Operating Temperature: 30W: 30ºC to 70ºC ( 22ºF to 158ºF). 60W: 30ºC to 55ºC ( 22ºF to 131ºF). · Storage Temperature: 30ºC to 85ºC ( 22ºF to 185ºF). · Humidity: 20 to 85%, non-condensing. Applications: · Provides PoE/PoE+ and Hi-PoE for cameras/devices. Mechanical: · NEMA 4X, IP66 Rated enclosure for outdoor use. · Dimensions (H x W x D approx.): 9.5" x 7.32" x 4.92" (241.3mm x 185.9mm x 125mm). Models: · NetWay1DWP: Outdoor Single Port Hi-PoE Injector. · NetWay1DWPH: Outdoor Single Port Hi-PoE Injector, enclosure with three (3) 5/8" wiring inlets, includes NEMA rated glands. Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. 1. Remove circuit board from enclosure prior to drilling NetWay1DWP (do not discard hardware). Note: Take care to assure that hardware will not interfere with components of the circuit board. 2. NetWay1DWP: Mark and drill desired inlets on the enclosure to facilitate wiring (Fig. 2, pg. 4). Maximum UL Listed NEMA type 4X rated fittings to be used is 1/2", follow manufacturer's specifications for the appropriate size opening. Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets. NetWay1DWPH is pre-drilled with three (3) pre-drilled inlet holes for wiring. 3. Clean out the inside of enclosure before remounting circuit board. 4. Switch circuit breaker to the OFF position. 5. Connect AC power from a UL approved circuit breaker to the terminals marked Fig. 1 [L] and [N], connect ground to the terminal marked [G] (refer to Fig. 1 on right). 115VAC/230VAC 6. Mounting NEMA 4X rated enclosure: Input Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking LGN nuts, etc.) which are compatible with mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 4, pg. 7). Pole Mount: refer to page 7. Note: All inlets for conduit fittings should be on the bottom of the enclosure. Line Neutral Ground 7. Mount circuit board in enclosure with hardware. 8. To facilitate wire entry utilize weather-tight NEMA rated connectors (supplied), bushings and cable. 9. Connect structured cable from UL Listed ethernet switch or video server to RJ45 jack marked [IN] on NetWay1DWP/NetWay1DWPH (Fig. 3, pg. 5). 10. Connect structured cable from camera/device to RJ45 jack marked [OUT] on NetWay1DWP/ NetWay1DWPH/ (Fig. 3, pg. 5). 11. Switch circuit breaker to the ON position. NetWay1DWP Installation Guide - 3 - Parameter Number of Ports Input Power Requirements Environmental Conditions Regulatory Compliance Weights (approx.) Technical Specifications: Description One (1) Hi-PoE (60W) or IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant. 115VAC, 60Hz, 1.2A or 230VAC, 50/60Hz, 0.75A. Operating Ambient Temperature: 30W: 70ºC (158ºF). 60W: 55ºC (131ºF). Storage Temperature: 30ºC to 85ºC ( 22ºF to 185ºF). Relative humidity: 20 to 85%, non-condensing. Operating Altitude: 304.8 to 2,000m. UL 60950-1 UL 60950-22 CE Information Technology Equipment. Information Technology Equipment to be installed Outdoors. European Conformity. Product: 3.7 lb. (1.68 kg) | Shipping: 5 lb. (2.27 kg) Fig. 2 - Bottom of enclosure 1.125" 28.6mm 1.25" 31.8mm Suggested area 1.125" 0.875" for Inlets 28.6mm 22.2mm 2.4375" 61.9mm 4.25" 108mm - 4 - NetWay1DWP Installation Guide - 5 - NetWay1DWP Installation Guide Typical Applications: Fig. 3 OUT IN CAT-5 or Higher 100m Camera/ Device CAT-5 or Higher 100m LGN 115VAC/230VAC Input Line Neutral Ground Ethernet Switch NVR/Network Server Video Monitor Notes: - 6 - NetWay1DWP Installation Guide Wall Mount Installation 1. Place unit at desired location and secure with mounting screws (not included) (Fig. 4, pg. 7). Fig. 4 Pole Mounting Using Optional Pole Mount Kit PMK1 (not included): This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is intended for use with Altronix outdoor rated power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included). 1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 5, pg. 7). 2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16" hex socket driver (Fig. 6, pg. 7 and Fig. 8, pg. 7). Fig. 5 Fig. 6 Fig. 7 3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (Fig. 7, pg. 7). 4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 5, pg. 8). 5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16" hex socket (Fig. 7, pg. 7). 6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16" hex socket driver (Fig. 5, pg. 7). 7. Clip excess straps. Fig. 8 Fig. 9 2" to 8"(50.8mm to 203.2mm) diameter round pole Fig. 9a 5" (127mm) square pole NetWay1DWP Installation Guide - 7 - Mechanical Drawing and Dimensions (H x W x D approx.): 9.5" x 7.32" x 4.92" (241.3mm x 185.9mm x 125mm) 7.32" (185.9mm) 1.38" 3.54" (89.9mm) (35.1mm) 9.32" (236.7mm) 8.75" (222.2mm) 6.75" (171.5mm) 6.0" (152.4mm) 4.25" (108mm) 10-32 X 0.25" (6.4mm) 4 Places 6.27" (159.3mm) 8.75" (222.2mm) 316 Stainless Steel Padlock Latch Attached 0.375" (9.5mm) Padlock Eye 304 Stainless Steel Piano Hinge 0.312" (7.9mm) TYP 4 Places 4.0" (101.6mm) 4.92" (125mm) 9.5" (241.3mm) 8.0" (203.2mm) 4.35" (110.5mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IINetWay1DWP H19U MEMBER - 8 - NetWay1DWP Installation Guide