ATESS PCS100/250/500/630

Bidirectional Battery Inverter

Overview

Bidirectional battery inverter from 100kW to 630kW, can be used alone or with solar charger and other accessories for different application scenarios.

Features

Block Diagram

A block diagram illustrates the system's components, including DC input, DC EMI filter, DC breaker, DC BUS, AC filter, transformer, contactor, AC breaker, AC SPD, and the inverter itself, connected in a typical configuration for grid-connected and off-grid operation.

Technical Specifications

AC (Grid-connected)

Parameter PCS100 PCS250 PCS500 PCS630
Apparent power 110kVA 275kVA 550kVA 693kVA
Rated power 100kW 250kW 500kW 630kW
Rated voltage 400V 400V 400V 400V
Rated current 144A 361A 722A 909A
Voltage range 360V-440V 360V-440V 360V-440V 360V-440V
Rated frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Frequency range 45-55/55-65Hz 45-55/55-65Hz 45-55/55-65Hz 45-55/55-65Hz
THDI <3% <3% <3% <3%
PF 0.8lagging~0.8leading 0.8lagging~0.8leading 0.8lagging~0.8leading 0.8lagging~0.8leading
AC connection 3/N/PE 3/N/PE 3/PE 3/PE

AC (Off-grid)

Parameter PCS100 PCS250 PCS500 PCS630
Apparent power 110kVA 275kVA 550kVA 693kVA
Rated power 100kW 250kW 500kW 630kW
Rated voltage 400V 400V 400V 400V
Rated current 144A 361A 722A 909A
THDU <2% linear <2% linear <2% linear <2% linear
Rated frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Overload capability 110%-10mins, 120%-1min 110%-10mins, 120%-1min 110%-10mins, 120%-1min 110%-10mins, 120%-1min

DC (Battery)

Parameter PCS100 PCS250 PCS500 PCS630
Rated power 100kW 250kW 500kW 630kW
Current regulation ±1% ±1% ±1% ±1%
Voltage regulation ±1% ±1% ±1% ±1%
Voltage ripple <3% <3% <3% <3%
Current ripple <2% <2% <2% <2%
Voltage range 500V-820V 500V-820V 600V-900V 600V-900V
Max. charge/discharge current 220A 550A 917A 1155A

General Information

Parameter PCS100 PCS250 PCS500 PCS630
Protection degree IP20 IP20 IP20 IP20
Maximum efficiency 97.10% 97.30% 98.50% 98.50%
Noise emission <65dB(A)@1m <65dB(A)@1m <65dB(A)@1m <65dB(A)@1m
Operating temperature -25°C~+55°C -25°C~+55°C -25°C~+55°C -25°C~+55°C
Cooling Forced-air Forced-air Forced-air Forced-air
Relative humidity 0-95% non-condensing 0-95% non-condensing 0-95% non-condensing 0-95% non-condensing
Maximum altitude 6000m (derate above 3000m) 6000m (derate above 3000m) 6000m (derate above 3000m) 6000m (derate above 3000m)
Dimension(W/H/D) 1100/1890/850mm 1600/2080/850mm 1200/1900/800mm 1200/1900/800mm
Weight 820kg 1465kg 900kg 900kg
Build-in transformer Yes Yes No No
Transfer between on/off grid Manual(default), Automatic(optional) ≤10ms Manual(default), Automatic(optional) ≤10ms Manual(default), Automatic(optional) ≤10ms Manual(default), Automatic(optional) ≤10ms

Communication

Parameter PCS100 PCS250 PCS500 PCS630
Display Touch screen Touch screen Touch screen Touch screen
Communication RS485/CAN RS485/CAN RS485/CAN RS485/CAN

Certificate

CE, MEA, PEA, EN 61000-6-4:2007+A1:2011, EN61000-6-2:2005, EN62109-1:2010, EN62109-2:2011, NRS 097-2-1:2017, EN 50549-1:2019

PDF preview unavailable. Download the PDF instead.

PCS100-250-500-630-Datasheet Corel PDF Engine Version 21.0.0.593 CorelDRAW 2019

Related Documents

Preview ATESS HPS Hybrid Energy System User Manual
This user manual provides detailed product information and installation instructions for the ATESS HPS series hybrid energy storage integrated inverter. It covers product description, transportation, storage, installation, operation, maintenance, and troubleshooting.
Preview ATESS BYPASS 100/250/500/630/1000 User Manual
User manual for ATESS BYPASS series, covering installation, operation, maintenance, and specifications for models 100, 250, 500, 630, and 1000.
Preview ATESS ATS30/50/100/120/150 User Manual
This user manual provides comprehensive instructions for the ATESS ATS30/50/100/120/150 Automatic Transfer Switch, covering installation, operation, maintenance, and safety guidelines.