P-024-MP-CM-F12BK/8W008/5K016: TeraSPEED® Plenum Fiber Indoor Cable

Fiber indoor cable, TeraSPEED® Plenum for MPO Trunks, 24 fiber with 12 fiber subunits, Multimode composite, Feet jacket marking, Black jacket color.

Product Classification

Regional Availability
Asia | Australia/New Zealand | Latin America | Middle East /Africa | North America
Portfolio
CommScope®
Product Type
Fiber indoor cable
Product Series
P-MP

General Specifications

Cable TypeMPO trunk cable
Construction TypeNon-armored
Subunit TypeGel-free
Jacket ColorBlack
Jacket MarkingFeet
Subunit, quantity2
Fibers per Subunit, quantity12
Composite Fiber Count8 + 16
Total Fiber Count24

Dimensions

Height Over Jacket3.9 mm | 0.154 in
Width Over Jacket6.9 mm | 0.272 in
Buffer Tube/Subunit Diameter3 mm | 0.118 in

Representative Image Description

The representative image shows a cross-section of the fiber optic cable, illustrating the outer jacket, ripcord, and two 12-fiber subunits, each containing multiple colored optical fibers within a gel-filled buffer tube.

Mechanical Specifications

Minimum Bend Radius, loaded58 mm | 2.283 in
Minimum Bend Radius, unloaded39 mm | 1.535 in
Tensile Load, long term, maximum200 N | 44.962 lbf
Tensile Load, short term, maximum667 N | 149.948 lbf
Compression10 N/mm | 57.101 lb/in
Compression Test MethodFOTP-41 | IEC 60794-1 E3
Flex300 cycles
Flex Test MethodFOTP-104 | IEC 60794-1 E6
Impact0.74 N-m | 6.55 in lb
Impact Test MethodFOTP-25 | IEC 60794-1 E4
StrainSee long and short term tensile loads
Strain Test MethodFOTP-33 | IEC 60794-1 E1
Twist10 cycles
Twist Test MethodFOTP-85 | IEC 60794-1 E7
Vertical Rise, maximum500 m | 1,640.42 ft

Optical Specifications

Fiber TypeComposite MM/SM | G.652.D and G.657.A1, TeraSPEED® | OM4, LazrSPEED® 550 | OS2 | OS2

Environmental Specifications

Installation temperature0 °C to +70 °C (+32 °F to +158 °F)
Operating Temperature0 °C to +70 °C (+32 °F to +158 °F)
Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)
Cable Qualification StandardsANSI/ICEA S-83-596 | Telcordia GR-409
Environmental SpacePlenum
Flame Test ListingNEC OFNP (ETL) and c(ETL)
Flame Test MethodNFPA 262

Environmental Test Specifications

Heat Age0 °C to +85 °C (+32 °F to +185 °F)
Heat Age Test MethodIEC 60794-1 F9
Low High Bend0 °C to +70 °C (+32 °F to +158 °F)
Low High Bend Test MethodFOTP-37 | IEC 60794-1 E11
Temperature Cycle0 °C to +70 °C (+32 °F to +158 °F)
Temperature Cycle Test MethodFOTP-3 | IEC 60794-1 F1

Packaging and Weights

Cable weight29 kg/km | 19.487 lb/kft

Regulatory Compliance/Certifications

AgencyClassification
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system

Included Products

CS-5K-MP

LazrSPEED® 550 OM4 Bend-Insensitive Multimode Fiber

CS-8W-MP

TeraSPEED® OS2 Singlemode Fiber

Footnotes

Operating Temperature
Specification applicable to non-terminated bulk fiber cable

CS-5K-MP Specifications

Product Classification

Portfolio
CommScope®
Product Type
Optical fiber

General Specifications

Cladding Diameter125 µm
Cladding Diameter Tolerance±5 µm
Cladding Non-Circularity, maximum1 %
Coating Diameter (Colored)254 µm
Coating Diameter (Uncolored)245 µm
Coating Diameter Tolerance (Colored)±7 µm
Coating Diameter Tolerance (Uncolored)±10 µm
Coating/Cladding Concentricity Error, maximum12 µm
Core Diameter50 µm
Core Diameter Tolerance±2.5 µm
Core/Clad Offset, maximum1.5 µm
Proof Tensile Stress100,000 psi (0.69 GPa)

Mechanical Specifications

Macrobending, 15 mm Ø mandrel, 2 turns0.20 dB @ 850 nm | 0.50 dB @ 1,300 nm
Macrobending, 30 mm Ø mandrel, 2 turns0.10 dB @ 850 nm | 0.30 dB @ 1,300 nm
Macrobending, 75 mm Ø mandrel, 100 turns0.50 dB @ 1,300 nm | 0.50 dB @ 850 nm
Coating Strip Force, maximum8.9 N | 2.001 lbf
Coating Strip Force, minimum1.3 N | 0.292 lbf
Dynamic Fatigue Parameter, minimum18

Optical Specifications

Numerical Aperture0.2
Numerical Aperture Tolerance±0.015
Point Defects, maximum0.15 dB
Zero Dispersion Slope, maximum0.105 ps/[km-nm-nm]
Zero Dispersion Wavelength, maximum1316 nm
Zero Dispersion Wavelength, minimum1297 nm

Optical Specifications, Wavelength Specific

1 Gbps Ethernet Distance1,110 m @ 850 nm | 600 m @ 1,300 nm
10 Gbps Ethernet Distance550 m @ 850 nm
Attenuation, maximum1.00 dB/km @ 1,300 nm | 3.00 dB/km @ 850 nm
Backscatter Coefficient-68.0 dB @ 850 nm | -75.7 dB @ 1,300 nm
Bandwidth, Laser, minimum4,700 MHz-km @ 850 nm | 500 MHz-km @ 1,300 nm
Bandwidth, OFL, minimum3,500 MHz-km @ 850 nm | 500 MHz-km @ 1,300 nm
Differential Mode Delay0.70 ps/m @ 850 nm
Differential Mode Delay NoteSuperior to ANSI/TIA TIA-492AAAF and IEC 60793-2-10 at 850 nm
Index of Refraction1.479 @ 1,300 nm | 1.483 @ 850 nm

Standards Compliance

ANSI/TIA-492AAAF (OM4) | IEC 60793-2-10, A1 (OM4)

Environmental Specifications

Heat Aging, maximum0.20 dB/km @ 85 °C
Temperature Dependence, maximum0.1 dB/km
Temperature Humidity Cycling, maximum0.2 dB/km
Water Immersion, maximum0.20 dB/km @ 23 °C

Regulatory Compliance/Certifications

AgencyClassification
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system

Footnotes

Temperature Dependence, maximum
Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F)
Temperature Humidity Cycling, maximum
Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity

CS-8W-MP Specifications

Product Classification

Portfolio
CommScope®
Product Type
Optical fiber

General Specifications

Cladding Diameter125 µm
Cladding Diameter Tolerance±0.7 µm
Cladding Non-Circularity, maximum0.7 %
Coating Diameter (Colored)249 µm
Coating Diameter (Uncolored)242 µm
Coating Diameter Tolerance (Colored)±13 µm
Coating Diameter Tolerance (Uncolored)±5 µm
Coating/Cladding Concentricity Error, maximum12 µm
Core Diameter8.3 µm
Core/Clad Offset, maximum0.5 µm
Proof Tensile Stress100,000 psi (0.69 GPa)

Dimensions

Fiber Curl, minimum4 m | 13.123 ft

Mechanical Specifications

Macrobending, 20 mm Ø mandrel, 1 turn0.75 dB @ 1,550 nm | 1.50 dB @ 1,625 nm
Macrobending, 30 mm Ø mandrel, 10 turns0.25 dB @ 1,550 nm | 1.00 dB @ 1,625 nm
Macrobending, 60 mm Ø mandrel, 100 turns0.05 dB @ 1,550 nm | 0.05 dB @ 1,625 nm
Coating Strip Force, maximum8.9 N | 2.001 lbf
Coating Strip Force, minimum1.3 N | 0.292 lbf
Dynamic Fatigue Parameter, minimum20

Optical Specifications

Cabled Cutoff Wavelength, maximum1260 nm
Point Defects, maximum0.1 dB
Zero Dispersion Slope, maximum0.092 ps/[km-nm-nm]
Zero Dispersion Wavelength, maximum1324 nm
Zero Dispersion Wavelength, minimum1300 nm

Optical Specifications, Wavelength Specific

Attenuation, maximum0.40 dB/km @ 1,310 nm | 0.40 dB/km @ 1,385 nm | 0.40 dB/km @ 1,490 nm | 0.40 dB/km @ 1,550 nm | 0.50 dB/km @ 1,270 nm | 0.50 dB/km @ 1,575 nm
Backscatter Coefficient-79.6 dB @ 1,310 nm | -82.1 dB @ 1,550 nm
Dispersion, maximum18 ps(nm-km) at 1550 nm | 3.5 ps(nm-km) from 1285 nm to 1330 nm at 1310 nm
Index of Refraction1.467 @ 1,310 nm | 1.467 @ 1,385 nm | 1.468 @ 1,550 nm
Mode Field Diameter10.4 µm @ 1,550 nm | 9.2 µm @ 1,310 nm | 9.6 µm @ 1,385 nm
Mode Field Diameter Tolerance±0.4 µm @ 1310 nm | ±0.5 µm @ 1550 nm | ±0.6 µm @ 1385 nm
Polarization Mode Dispersion Link Design Value, maximum0.06 ps/sqrt(km)

Standards Compliance

ITU-T G.652.D | ITU-T G.657.A1 | TIA-492CAAB (OS2)

Environmental Specifications

Heat Aging, maximum0.05 dB/km @ 85 °C
Temperature Dependence, maximum0.05 dB/km
Temperature Humidity Cycling, maximum0.05 dB/km
Water Immersion, maximum0.05 dB/km @ 23 °C

Regulatory Compliance/Certifications

AgencyClassification
ISO 9001:2015Designed, manufactured and/or distributed under this quality management system

Footnotes

Temperature Dependence, maximum
Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F)
Temperature Humidity Cycling, maximum
Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity

For additional trademark information, visit: https://www.commscope.com/trademarks

PDF preview unavailable. Download the PDF instead.

p-024-mp-cm-f12bk-8w008-5k016-product-specifications-comprehensive COMMSCOPE

Related Documents

Preview CommScope TeraSPEED® Plenum MPO Trunk Cable P-024-MP-CM-F12RD/8W008/5K016 - Technical Specifications
Detailed technical specifications for the CommScope P-024-MP-CM-F12RD/8W008/5K016 TeraSPEED® Plenum MPO Trunk Cable, including product classification, general, mechanical, optical, and environmental specifications for CS-5K-MP and CS-8W-MP variants.
Preview CommScope P-072-MP-CM-F12BR/8W036/5L036 Fiber Indoor Cable Specifications
Detailed technical specifications for the CommScope P-072-MP-CM-F12BR/8W036/5L036 TeraSPEED Plenum MPO Trunk cable, including its components CS-5L-MP and CS-8W-MP, covering product classification, general, mechanical, optical, and environmental specifications, as well as regulatory compliance.
Preview CommScope Fiber Optic Cable Specifications: TeraSPEED® Plenum MPO Trunk, LazrSPEED® 300 OM3, and TeraSPEED® OS2
Detailed technical specifications for CommScope's P-072-MP-CM-F12AQ/8W036/5L036 TeraSPEED® Plenum MPO Trunk cable, including CS-5L-MP LazrSPEED® 300 OM3 and CS-8W-MP TeraSPEED® OS2 fiber types. Covers product classification, general, mechanical, optical, and environmental specifications, along with regulatory compliance.
Preview CommScope P-072-MP-CM-F12GR/8W036/5L036 Fiber Optic Cable Specifications
Technical specifications for CommScope's P-072-MP-CM-F12GR/8W036/5L036 indoor fiber optic cable, featuring LazrSPEED 300 OM3 and TeraSPEED OS2 Singlemode fiber types, detailing mechanical, optical, environmental, and compliance data.
Preview CommScope TeraSPEED P-024-MP-8W-F12BK Fiber Optic Cable Specifications
Detailed technical specifications for the CommScope TeraSPEED P-024-MP-8W-F12BK fiber indoor cable, covering product classification, general, mechanical, optical, environmental, and regulatory compliance details.
Preview CommScope P-002-MP-8W-F20 TeraSPEED Fiber Indoor Cable Specifications
Detailed technical specifications for the CommScope P-002-MP-8W-F20 TeraSPEED Plenum Light Duty Interconnect Cordage, featuring 2 fibers, Singlemode G.652.D and G.657.A1. Includes mechanical, optical, environmental, and regulatory data. For trademark information, visit https://www.commscope.com/trademarks.
Preview CommScope P-072-MP-8W-F12GR TeraSPEED® Plenum MPO Trunk Cable: Technical Specifications and Fiber Details
Detailed technical specifications for the CommScope P-072-MP-8W-F12GR TeraSPEED® Plenum MPO Trunk Cable, including its included CS-8W-MP Singlemode Fiber specifications, mechanical, optical, and environmental properties.
Preview CommScope LazrSPEED N-032-MP-5K-F08AQ/20T/B2 Fiber Optic Cable Specifications
Detailed technical specifications for the CommScope LazrSPEED N-032-MP-5K-F08AQ/20T/B2 fiber indoor MPO trunk cable, including product classification, general, mechanical, optical, environmental, and regulatory compliance details. Also includes specifications for the included CS-5K-MP fiber.